HomeMy WebLinkAboutRESCHECK - 08-00013 - 821 Griffin - New SFRr4REScheck Software Version 4.0.1
Compliance Certificate
Project Title: Duane Adamson-ID0067 08 00013
Report Date: 12110/07
Data filename: Untitled.rck
Energy Code: 20031ECC 821 Griffin St-Adamson
Location: Rexburg, Idaho
Construction Type: Single Family
Glazing Area Percentage: 13%
Heating Degree Days: 8693
Construction Site: Owner/Agent: Designer/Contractor:
Lot 14 Blk 8 Henderson Sub No. 3
Rexburg, ID 83440
Ceiling 1: Raised or Energy Truss:
1318 38.0 0.0
33
Wall 1: Wood Frame, 16" o.c.:
1218 19.0 0.0
61
Window 1: Vinyl Fmme:Double Pane with Low -E:
163 0.390
64
Door 1: Solid:
40 0.170
7
Floor 1: All -Wood JoistfTruss:Over Unconditioned Spam:
1265 19.0 0.0
59
Furnace 1: Forced Hot Air: 80 AFUE
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title Signature Date
J 11 ANI C.O\li5
L!
CITY OF REXBURG
Duane Adamson -1D0067 Page 1 of 4
CREScheck Software Version 4.0.1
�j( Inspection Checklist
Date: 12/10/07
Ceilings:
❑ Ceiling 1: Raised or Energy Truss, R-38.0 cavity insulation
Comments:
Insulation must achieve full height over the plate lines of exterior walls.
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation
Comments:
Windows:
❑ Window 1: Vinyl Frame:Dcuble Pane with Low -E, 1.1 -factor: 0.390
For windows without labeled 1.1 -factors, describe features:
#Panes—Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1: Solid, U -factor: 0.170
Comments:
Floors:
❑ Floor 1: All -Wood Joist/Truss:Over Unconditioned Space, R-19,0 cavity insulation
Comments:
Heating and Cooling Equipment:
❑ Furnace 1: Forced Hot Air: 80 AFUE or higher
Make and Model Number:
Air Leakage:
E] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed.
U Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air -fight assembly with a 0.5' clearance from
combustible materials. If non -IC rated, fixtures are Installed with a 3" cleamnce from insulation.
Skylights:
o Minimum Insulation requirement for skylight shafts equal to or greater than 12 inches is R-19,
Vapor Retarder:
u Installed on the warm -In -winter side of all non -vented framed ceilings, walls, and floors.
Materials Identification:
Materials and equipment are installed in accordance with the manufacturers installation instructions.
U Materials and equipment are Identified so that compliance can be determined.
u Manufacturer manuals for all Installed healing and cooling equipment and service water hearing equipment have been provided.
Ei Insulation R -values, glazing 1.1 -factors, and heating equipment efficiency are clearly marked on the building plans or specifications.
Li Insulation Is installed according to manufacturers Instructions, In substantial contact with the surface being Insulated, and in a
manner that achieves the rated R -value without compressing the insulation.
Duct Insulation:
Duane Adamson-ID0067 ` Page 2 of 4
L) Supply ducts in unconditioned attics or outside the building are insulated to R-11.
Lj Return ducts in unconditioned attics or outside the building are insulated to 3-B.
L] Supply ducts in unconditioned spares are insulated to R-11.
❑ Return ducts in unconditioned spaces (except basements) are insulatec to R-2. •s_.a. _ - c: -e;-'-ac on —um cccts is
basements.
❑ Where exterior walls are used as plenums, the wall is insulated to R-11.
Duct Construction:
Lj Duct connections to flanges of air distribution system equipment are sea.e_ anc ..nemar.:caliy `astened.
L] All joints, seams, and connections are securely fastened with welcscaskets. mas:ics - acteslves), mastic-plus-embedded-`abdc
or tapes. Tapes and mastics are rated UL 181 A or U L 181 B.
Exceptions:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in, w.g. (500 Pa).
Lj The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Service Water Heating:
Li Water heaters with vertical pipe risers have a heat trap on both the Inlet and outlet unless the water heater has an integral heat
trap or is part of a circulating system.
C] Circulating hot water pipes are insulated to the levels In Table 1.
Circulating Hot Water Systems:
O Circulating hot water pipes are insulated to the levels In Table 1.
Swimming Pools:
O All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable
sources. Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Duane Adamson-ID0087 Page 3 of 4
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Table 2: Minimum Insulation Thickness for HVAC Pipes
Insulation Thickness In Inches by Pipe Sizes
Insulation Thickness In Inches by Pipe Sizes
Piping System Types
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water
Up to 1"
Up to 1.25"
.�" "..'c:=-
Over 2"
Temperature ('P)
Low Pressure/Temperature
201-250
170-180
0.5
1.0
1.5
2.0
140-169
0.5
0.5
1.0
1.5
100.139
0.5
0.5
15
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
NOTES TO FIELD: (Building Department Use Only)
Duane Adamson -00067 Page 4 of 4
Insulation Thickness In Inches by Pipe Sizes
Piping System Types
Fluid Temp.
Range ff)
2" Runouts 1" and Less
1.25" to 2,0"
2.5" to 4"
Healing Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
106-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
_ Any_ . _.
_ _ to
___ .. ..1.0
1.5
.. 2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
Duane Adamson -00067 Page 4 of 4