HomeMy WebLinkAboutRESCHECK - 08-00003 - 596 Stonebridge - New SFRrGenerated by REScheck-Web Software �(, Compliance Certificate Report Date: 01/02108 0800003 Energy Code: 20061ECC 596 Stonebridge -Shattuck Location: Rexburg, Idaho Construction Type: Single Family Bullldng Orientation: Bldg. faces 270 deg. from North Conditioned Floor Area: 1603 ft2 Glazing Area Percentage: 11% Heating Degree Days: 8693 Climate Zone: 6 '''.//` Construction Site: Owner/Agent: Designer/Contractor: be'ly ((� (go; I� Compliance: 3.9% Better Than Code Maximum UA: 331 Your UA: 318 Ceiling 1: Flat or Scissor Truss 18DO 0.0 40.0 43 Wall 1: Wood Frame, 16m. o.c. 1854 24.0 0.0 86 Orientation: Unspecified Window 1: Vinyl Frame, 2 Pane wl Low•E 196 0.320 63 SHGC: 0.15 Orientation: Unspecified Door 1: Solid 63 0.350 22 Orientation: Unspecified Basement Wall 1: Solid Concrete or Masonry 1648 11.0 0.0 104 Orientation: Unspecified Well height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Furnace 1: Forced Hot Air (Non-Eleatdc)91 AFUE Air Conditioner 1: Electric Central Air13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2006IECC requirements In REScheck-Web and to comply with the mandatory requirements listed In REScheck Ins action Checklist. �i�ct SIC Z el- v //0— 0 Name - Title Sign lure Date Li I�es� y L301 Ict el— v.� JAN - 3 2008 I CITY 0 RE____ XB,_ Project Title: Report date: 01102108 Data filename: Page 1 of 3 rGenerated by REScheck-Web Software �(, Inspection Checklist Date: 01/02/08 Ceilings: ❑ Ceiling 1: Flat or Scissor Truss, R-40.0 continuous insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 161n. o.c., R-24.0 cavity Insulation Comments: Basement Walls: ❑ Basement Wall 1: Solid Concrete or Masonry, 8.0' ht / 7.0' bg 18.(Y insul, R-11.0 cavity insulation Comments: Windows: ❑ Window 1: Vinyl Frame, 2 Pane w/ Low -E, U -factor: 0.320 For windows without labeled U -factors, describe features: #Panes—Frame Type Thermal Break?—Yes—No Comments: _ Note: Up to 15 sq.ft. of glazed fenestration per dwelling is exempt from U -factor and SHGC requirements. Doors: D Door 1: Solid, U -factor: 0.350 Comments: Heating and Cooling Equipment: ❑ Furnace is Forced Hot Air (Non -Electric): 91 AFUE or higher Make and Model Number: ❑ Air Conditioner 1: Electric Central Air: 13 SEER or higher Make and Model Number. Air Leakage: Lj Joints, penetrations, and all other such openings In the building envelope that are sources of air leakage are sealed. C] Recessed lights are either 1) Type IC rated with enclosures sealed/gasketed against leaks to the ceiling, or 2) Type IC rated and ASTM E283 labeled, or 3) Installed Inside an air -tight assembly with a 0.5° clearance from combustible materials and a 3' clearance from insulation. Vapor Retarder: El Vapor retarder is installed on the warm -in -winter side of all non -vented framed ceilings, walls, and floors; or it has been determined that moisture or its freezing will not damage the materials; or other approved means to avoid condensation are provided. Comments: Materials Identification: Materials and equipment are Identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. Insulation R -values, glazing U -factors, and heating equipment effidency are clearly marked on the building plans or specifications. Insulation is installed according to manufacturers instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R -value without compressing the Insulation. Duct Insulation: Project Title: Report date: 01/02/08 Data filename: Page 2 of 3 Q Ducts In unconditioned spacer utside the building are insulated to at least R-8. D Ducts in floor trusses above unc„nditioned spaces or above the outdoors are insulated to e, yeast R-8. Duct Construction: Lj Air handlers, filter boxes, and duct connections to flanges of air distribution system equipment or sheet metal fittings are sealed and mechanically fastened. L] All joints, seams, and connections are made substantially airtight with tapes, gasketing, mastics (adhesives) or other approved closure systems. Tapes and mastics are rated UL 181A or UL 1818. Building framing cavities are not used as supply ducts. Lj Automatic or gravity dampers are Installed on all outdoor air Intakes and exhausts. Additional requirements for tape sealing and metal duct crimping are included by an inspection for compliance with the International Mechanical Code. Temperature Controls: ❑ Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor is provided. Heating and Cooling Equipment Sizing: Lj Additional requirements for equipment sizing are included by an inspection for compliance with the Intemational Mechanical Code. Circulating Hol Water Systems: E] Circulating hot water pipes are insulated to R-2. El Circulating hot water systems Include an automatic or accessible manual switch to tum off the circulating pump when the system Is not in use. Heating and Cooling Piping Insulation: Lj HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are Insulated to R-2. Certificate: A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R -values; window U -factors; type and efficiency of space -conditioning and water heating equipment. NOTES To FIELD: (Building Department Use Only) Project Title: Report date: 01/02108 Data filename: Page 3 of 3 2006 IECC anergy 1 Efficiency Certificate Insulation Rating R -Value Ceiling I Roof 40.00 Wall 24.00 Floor / Foundation 11.00 Ductwork (unconditioned spaces): _ Glass & Door Window 0.32 0.15 Door Heating & Cooling Equipment 0.35 NA Efficiency Forced Hot Air (Non -Electric) Furnace 91 AFUE Electric Central Air Conditioner 13 SEER Water Heater: Name: Date: Comments: