HomeMy WebLinkAboutRESCHECK - 08-00001 - 819 Yost St - New SFRREScheck Software Vers
Compliance CE
Project Title: Josh Leder
Report Date: 12/31/07
Data filename: C:IDOCUME-1Rule1MYDOCU-1tRescheddexample.rck
0800001
819 Yost -Leder
Energy Code: 2003 IECC
Location: Rexburg, Idaho
Construction Type: Single Family
Glazing Area Percentage: 17%
Heating Degree Days: 8693
Construction Site: Owner/Agent: Designer/Contractor:
819 Yost Street
Rexburg, ID 83440
Permit Date: 3/17/00
Gelling 1: Fiat celting or Scissor Truss:
1424
50.0
0.0
37
Ceiling 2: Flat Ceiling or Scissor Truss:
1424
38.0
0.0
43
Wall 1: Wood Frame, 16" o.c.:
1655
" 21.0
6.0
60
Door 1: Solid:
40
0.350
14
Window 1: Vinyl Frame, Double Pane with Low -E:
276
0.450
124
Door 2: Solid:
20
0.540
11
Door 3: Solid:
20
0.540
11
Basement Wall 1: Wood Frame:
1655
21.0
0.0
76
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
Floor 1: All -Wood Joist/rruss:Over Unconditioned Space:
1424
21.0
0.0
63
Floor 3: Slab-On-Gmde:Unhealed:
1424
8.0
1108
Insulation depth: 2.0'
Furnace 1: Forced Hot Air: 85 AFUE
Compliance Statement The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in
REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name - Title
Project Notes:
Signature
Date
Josh Leder
Page 1 of 1
m;n 08 08 02:31p Andrew Johnson
■
�0
January 8, 2008
City of Rexburg,
208-356-0525
Heating calculation for Nomarco Construction, New home at 819 Yost st. hlenderson
Subdivision, Rexburg, Idaho.
As per the RCScheck provided by the contractor the heat loss for the home is figured as
follows_
IJA value: 333
Design indoor temp. _ 70 F
Design outdoor condition = -20 F
Delta'P: 90 F
I teat loss = 29,970 BTU
Infiltration value: .95%— 31,635 BTU
Minimum BTIJ required =61,605 BTU
It is proposed to install a 80.000 BTUfurnace wil.lt a 3 ton blower.
."I
Andrew John.4on
Johnson Pleating LLC
HVAC License # 1327
State of Idaho