HomeMy WebLinkAboutPLANS - 20-00659 - 991 Pine Brook Ln - New SFRElevations Scale: 1/4" & 1/8" =1'-0" on 36" x 24" Paper Scale: 1/8" & 1/16"=1'-0" on 17" x 11" Paper A1 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Bonus Room A5-Cross Section A6-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit SetBid Set TOTAL SQ. FTG.= 4556 MAIN FLOOR=1889/1785 INTERIOR SECOND FLOOR=770/710 INTERIOR BASEMENT=1897/1675 INTERIOR GARAGE=1074 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A6 of Rev Co o p e r Re s i d e n c e PE R M I T S E T 17 x 1 1 07-27-2020 Front Elevation Back Elevation Right ElevationLeft Elevation 6:12 Pitch Main, Front and Sides 9' Main Walls 9' Second Floor Walls 9' Basement Foundation Walls Garage to Match Main TYP Shake Siding 6 12 4:12 Pitch 8:12 Metal Roof 6 12 8 12 Faux Stone Board and Batten 9' 9' 9' 6 12 12 6 12 8 6 12 Board and Batten Board and Batten Board and Batten Faux StoneFaux Stone 08-11-2020 8' 8" 5' 8" 3' See above Foundation Plan Scale: 1/4"=1'-0" 36"x24" Size Paper Scale: 1/8"=1'-0" 17"x11" Size Paper Ventilation R408.1 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout GFoundation Wall System: 2x6 Treated Sill Plate over Foam Sill Sealer with 12" Anchor Bolts @ 72" O.C. 10" Long, 7" Embedded Max. 12" from all Corners or Splices Concrete Wall Greater than 9' need to have an Architects or Engineer Seal 8' & under (1) Horiz. Bar in top 12" and one at mid-height 8'-1" to 9' (1) Horiz. Bar in top 12" & one bar at each third point Min. (2) Anchor Bolts per Sill Plate w/ nut & ROUND plate Washer 2 1/2 Ø x14" Min. For each Bolt over Concrete Foundation wall Consistent w/ 2015 IRC R401-403 With Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/ 2015 IRC Section R106.1 over Undisturbed Soil Window Well System: 2015 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. One egress ladder shall be provided within a window well of an unfinished basement J A2A2 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Bonus Room A5-Cross Section A6-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit SetBid Set Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms S Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM TOTAL SQ. FTG.= 4556 MAIN FLOOR=1889/1785 INTERIOR SECOND FLOOR=770/710 INTERIOR BASEMENT=1897/1675 INTERIOR GARAGE=1074 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A6 of Rev Co o p e r Re s i d e n c e PE R M I T S E T 17 x 1 1 Window Callouts: Width then Height (ex. 3050 is 3'0" wide by 5'0" Tall) Door same SH-is Single Hung DH is Double Hung SV is Side Vent Fix is Fixed or Picture T or Temp is Tempered Safety Glass Tra is Transom 07-27-2020 Lin e n WH 4040 SV 40 4 0 S V 30 6 8 30 6 8 3068 2 4 6 8 2668 2668 2- 2 4 6 8 B a r n Up Bedroom 5 12'-1" x 10'-4" 10 CFM Fresh Air Smoke Detector Bath 50 CFM Family Room 17'-6" x 16'-3" 10 CFM Fresh Air Cut 3' for Passage Opening with Req. Blocking Cut 18' for Garage Door opening with Req. Blocking Bedroom 6 12'-1" x 10'-6" 10 CFM Fresh Air Smoke Detector Game Area 12'-10" x 17'-1" 10 CFM Fresh Air Toy Storage Cold Storage FurnWH Storage 3068 7'-2" 26 6 8 Floor Direction Play Area under stairs 3' 7'- 5 " 3' 8" 8" 8" 3'4'-6"6' 8'14'-6" 11'-6" 71' 15'33'-6" 16 ' - 8 " 15'-9"17'-9" 11 ' - 4 " 6'- 2 " 3'- 1 0 " 30 ' - 2 " 28 ' - 1 0 " 8' 11 ' - 2 " 22 ' 2' 3'-8" 10 ' - 1 0 " 62 ' - 2 " 3'-10"12'-4" 11'-10" 2'-4" 6' 17'-10" 10'-2"10'-4"9' 10 ' - 2 " 9'- 2 " 7'- 1 0 " 3'- 8 " 18 ' 2' 10 ' - 4 " 7'- 8 " 3'- 4 " 2x6 Walls 8' 6' 7'7'-4" 11'-4" 23'-4" 6' 12 ' - 1 0 " 52'-10" 6'- 3 " 22'-9" 17 ' - 6 " 3'-11" 3'- 1 0 " 2' 7'- 5 " 3'- 1 0 " 5' 7'- 4 " 3'- 8 " 11 ' - 1 1 " 6'-7" 7" 6" Cut 10' for Garage Door opening with Req. Blocking 10 ' - 4 " 14 ' - 8 " 5'- 2 " 22'-6" 25 ' 8"8'-6" 14'-4"TRIPLE CAR GARAGE 4" CONCRETE SLAB SLOPE CONC. FLOOR TO DRAIN TO GARAGE DOOR 9' Basement F. Walls CoF CoFCenter of Footing Center of Footing CoF Ce n t e r o f Fo o t i n g Co F Co F 9'-1" 7'- 1 0 " 4040 SV 4'-6" 2 6 6 8 24 6 8 24 6 8 2 4 6 8 Beam Ce n t e r o f Co n t . F o o t i n g 40 4 0 S V 6' Flo o r J o i s t D i r e c t i o n Flo o r J o i s t D i r e c t i o n Flo o r J o i s t D i r e c t i o n Flo o r J o i s t D i r e c t i o n Flo o r J o i s t D i r e c t i o n Fl o o r J o i s t D i r e c t i o n Mech./ Storage 3' Clearance in front of Furnace Seismic Straps around WH Be a m 9' Main Walls 9' Second Floor Walls 9' Basement Foundation Walls Garage to Match Main TYP 7 8 9 10 11 12 13 14 15 166 2668 2668 26 6 0 Media Closet 8'-5" Furnace: Location of furnace and water heater 2015 IRC, Section R106, and M1305 Elevate all sources of ignition in the garage a min. of 18" above the floor 2015 IRC, Sections R106, and M1307.3 Provide a protection post in the garage to prevent vehicle damage to furnace and water heater. 2015 IRC, Section R106, M1307.3.1 50 CFM Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Laundry 50 CFM Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. J J 4" Conc. Pour Over Undisturbed Soil T-Wall 29'-6" 2" P o r c h Ca p 08-11-2020 5' 11 ' - 1 1 " See Detail on A5 2" Rock Ledge Duct Chase 13'-2" 52 ' 2" R o c k L e d g e CoF 2'-5" 13'-2" 2'- 4 " 2'-5" 2" Rock Ledge 6'- 4 " 2'-6" 2" Rock Ledge 6'- 8 " 2" R o c k Le d g e MicroLam Beam 2" R o c k L e d g e 2" Rock Ledge 2" Rock Ledge 7'- 1 0 " Cut 3' for Passage Opening with Req. Blocking 2 Ply 11 3/4" 6' 2" Rock Ledge 7'- 1 0 " 2" R o c k Le d g e 3'- 6 " 3'- 1 0 " S CM 8" Theater 21'-7" x 13'-5" 10 CFM Fresh Air 6'6'9'-7" Main Floor Scale: 1/4"=1'-0" 36"x24" Size Paper Scale: 1/8"=1'-0" 17"x11" Size Paper A3 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Bonus Room A5-Cross Section A6-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit SetBid Set TOTAL SQ. FTG.= 4556 MAIN FLOOR=1889/1785 INTERIOR SECOND FLOOR=770/710 INTERIOR BASEMENT=1897/1675 INTERIOR GARAGE=1074 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A6 of Rev Co o p e r Re s i d e n c e PE R M I T S E T 17 x 1 1 07-27-2020 Dn DW 30 ' 24 ' 54 ' 18 ' WIC2'10' 29'-8" 12' 22'-6" 25 ' 8' 14'-6"8'15' 18'15'-6" 8' 16 ' - 2 " 6'- 4 " 6'- 2 " 11 ' - 4 " 12 ' 71' 60 ' 7'-8" 306 8 4050 SV 50 5 0 F T 4 0 4 0 S V 2-3050 SH 3'-2" 6' 6'- 8 " 4' 6" 17 ' - 6 " 28 6 8 18 ' x 8 ' O H G a r a g e D o o r 10' x 8' OH Garage Door 14'-10" 6'6' 6'6' 8' 62 ' 3'-2"5'5'4'-10"7'-6"8' 4' 4' 4' 4' 6' Step Step 5040 SV 3060 SH 8010 Tra 5010 Tra 6010 Tra 4010 Tra 3050 SH5050 F 6'-4" 2'2' 7'-4"2' 6060 F 33'-6" Pantry 6'- 4 " 8'- 6 " 30 5 0 S H 30 6 8 40 6 8 B a r n 3' 10 ' - 8 " 2'- 6 " 30 6 8 3'- 4 " 3' 3-2650 SH 12 ' 12 ' 3060 SH 28 ' - 8 " 11'5'-10" 3050 SH 4' 6'2'-10" 11'-4" 10 ' - 2 " 6' 2' 9' 2' 2' 18 ' 2' Line of Second Floor 3'-2"4'-4"4'-4"3'-2"2'-9"8'-3"11'-6" 30 5 0 S H 3050 SH 3050 SH 6'12' 18' 2' 2' 3'- 4 " 5'-6"5'-6" 22'-10" 2'-6" 14'-6" 40 8 0 8' 10 ' 13 ' 2'-2"12'-8" 4'2'2'-2"3'-4"6'-6" 2' 12 ' 6'-6"7'-8"7'-8"4'10'-10" 10 ' - 6 " 1'- 1 0 " 8'-6"2'4'5'-6"2'-6" 6' 3'- 1 0 1 / 2 " 2'-6"2'-10"6'-2" 5'-8" 1'- 4 " 6'- 6 " 3'- 4 " 6' 3'- 4 " 2'- 8 " 3'- 1 0 " 10 ' - 6 " Up 2'-8"8'-2" 2468 2468 LN 2 6 6 8 2468 Bench w/ Cabinets Above Dining 14'-0" x 11'-2" 10 CFM Fresh Air 9' Flat Ceiling Great Room 18'-0" x 16'-10" 10 CFM Fresh Air 2 Story Ceiling Entry 2 Story Ceiling 266 8 16 6 8 2x 6 W a l l 2x 6 W a l l Sh e l v e s 8050 F Kitchen 14'-0" x 11'-10" 100 CFM 9' Flat Ceiling Mud Room/ Laundry 50 CFM 80 WHF Bath 50 CFM Office 11'-2" x 9'-8" 10 CFM Fresh Air 9' Flat Ceiling Master Bedroom/1 15'-0" x 15'-8" 10 CFM Fresh Air 9' Walls w/ 12" Box Tray Smoke Detector Master Bath 50 CFM 3 Car Garage 1074 SF 5' Wire for Generator Hook Up 9' Main Walls 9' Second Floor Walls 9' Basement Foundation Walls Garage to Match Main TYP 11" Min. Covered Porch 9' Cap Raised Patio 11" Min. 1 2 3 4 5 6 7 8 9 123456 30 6 8 Sh e l v e s Gas Outlet for BBQ 2468 11'-10"3'-8" Ca b i n e t s i n I s l a n d Shelves 8' HH 8' HH 8' HH 2668 Barn Line of Second 2'- 1 0 " Tech Room 7'-8" x 9'-8" 50 CFM 37'-4" Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout 3' Hallway Clearance 2015 IRC, Section R106 and R311.6 Saftey Glazing 2015 IRC, Sections R106 and R308.4.5 Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms S Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Window Callouts: Width x Height (ex. 3050 is 3'0" wide by 5'0" Tall) Door same SH-is Single Hung DH is Double Hung SV is Side Vent F is Fixed or Picture T or Temp is Tempered Safety Glass Tra is Transom OBS Obscured F l o o r 08-11-2020 Garage Portals: Alternate Braced Wall Panel Garage Portal Design CS-PF See Figure R602.10.6.4 on Sheet A4 CS-PF CS-PF CS-PF CS - P F CS - P F 7 4' 5'-10" 6'- 8 " SCM 4'-4" 2'- 4 " Railing 2' 4'- 6 " 3' 5'- 4 " 9'-4"2'-8" 2'- 8 " IB W P 5 ( 4 ' ) E a . S i d e IBWP 5 (4') IBWP 5 (4') Ea. Side 2'-6"5'-2"Du c t C h a s e 3'- 1 0 " Flo o r J o i s t D i r e c t i o n Bearing Wall Beam Sized by others (3 TYP) 2' X2' Rock base W/ tapered column Second Floor Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bedrooms 10 CFM fresh air Bathrooms 50 CFM Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. 4'Nailing or Screws 7" O.C. Max Horiz. & Vert. Blocks at Drywall Joints for 7" O.C. Screws of Nails Drywall is shown cutaway Overlapped Double Plate 2x6 Exterior wall @16"O.C. with 7/16" Waferboard Drywall & Waterboard not Shown for clarity 2x4 Interior Wall @16" O.C. 4'x8' Shear Panel on Both Sides 4' 8'x8' Shear Panel on Single Side 48 . 5 " t o c n t r IBWP 3 Interior Braced Wall Panel IBWP 2015 IRC Section 602.10.1 BWP 3-Interior Braced Wall Method 3 (IRC R602.10) 2x4 Studs @ 16" O.C. w/7/16" OSB Nailed 5" O.C. and 10" Field IBWP 5-Interior Braced Wall Method 5 1/2" min. Gypsum board 48" length applied to both sides OR 96" to one side covering 3 studs spaced 16" or 2 studs spaced 24" apart, blocked Screwed @7"/7" w/1" Drywall Screws All Vert Joints occur over stud All Hori. Joints blocked w/2x4 blocking Braced Wall Panel BWP 3' Braced Walls at each strap with 7/16" OSB one side, blocked in all joints Nailed @ 6"/12" w/ 8d or Stapled @ 4"/8" w 16 ga. All joints must occur over raming member 6" at edge 12" in field 4' 8d @ 12" O.C. in field 8d Nails @ 6" O.C. @ edge Braced Wall Panel Detail BWP IBWP 5 All exterior wall are braced walls. Second Floor Scale: 1/4"=1'-0" 36"x24" Size Paper Scale: 1/8"=1'-0" 17"x11" Size Paper A4A4 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Bonus Room A5-Cross Section A6-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit SetBid Set Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms S Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM TOTAL SQ. FTG.= 4556 MAIN FLOOR=1889/1785 INTERIOR SECOND FLOOR=770/710 INTERIOR BASEMENT=1897/1675 INTERIOR GARAGE=1074 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A6 of Rev Co o p e r Re s i d e n c e PE R M I T S E T 17 x 1 1 07-27-2020 Window Callouts: Width x Height (ex. 3050 is 3'0" wide by 5'0" Tall) Door same SH-is Single Hung DH is Double Hung SV is Side Vent F is Fixed or Picture T or Temp is Tempered Safety Glass Tra is Transom OBS Obscured Dn 1' Cantilever over Garage Bath 50 CFM Bedroom 2 9'-2" x 10'-0" 10 CFM Fresh Air 9' Flat Ceiling Smoke Detector Bedroom 3 10'-4" x 10'-0" 10 CFM Fresh Air 9' Flat Ceiling Smoke Detector Bedroom 4 11'-4" x 10'-4" 10 CFM Fresh Air 9' Flat Ceiling Smoke Detector 2x 6 W a l l Loft 17'-6" x 12'-0" 10 CFM Fresh Air 9' Flat Ceiling 11 ' - 1 0 " 41' 34 ' 2 6 6 8 26 6 8 26 6 8 26 6 8 4040 SV4040 SV 8' HH2-4050 SH 4'7'-10"5'-8" 11'-2"11'-10"18' 6'6'5'-6"2'-4" 12'11'-4"11'-2" 41' 12 ' 14 ' - 8 " 34 ' - 6 " 3'- 1 0 " 13 ' 24 6 8 6" 3'- 6 " 10 ' - 1 0 " 6'-6" 3'- 4 " 1234567891011 12 13 14 15 16 3'-10" 2 4 6 8LN 2 4 6 8 246 8 Open to Below Open to Below 4050 SH 2'-10"3'-8" 6'-6" 3'-6" 11'-10"3'-8" 7'- 2 " 4'- 6 " 3'- 1 0 " 5' 5'3' 3' 8'- 4 " 3' 2' 9'-6" 9' Main Walls 9' Second Floor Walls 9' Basement Foundation Walls Garage to Match Main TYP 8' HH 8' HH 2020 F 30 4 0 C a s e 1'-6" Cantilever over Garage 2'-6"2'-6" 2020 F 2020 F 3' 8'- 1 0 " 8' HH 8' HH 2nd Floor: 770 SF 10'-4" 2 4 6 8 2 4 6 8 2 4 6 8 246 8 2'- 8 " 7' 10 ' 3050 F 6050 F 3050 F 3'2'- 3 " 2'- 5 1 / 2 " 3' 6'2'- 3 " 3' 3'-2"5'5'4'-10" 3'-1"3'-1" 3'-10" x 3'-10" Cantilever over Great Room 08-11-2020 50 CFM 7'-8" 2'-4" SCM 26 ' - 6 " 8' 5'-6" 2010 F 6" Cross Section Floor System: Interior Walls: Exterior Walls: Soffit System: A C E D B Alternate Reinforcing Bar Size and Spacing Vertical Rebar Only 8" nominal wall thickness 72" Max rebar spacing #4 @ 15" is equal to #5 @ 23" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 36" Load-Bearing Value of Soil (psf) 1500 2000 3000 Conventional Light-frame Construction 1-story 2-story 3-story 4" Brick Veneer over light frame 1-story 2-story 3-story 12 21 32 12 16 24 12 15 23 12 12 17 12 12 16 Table R403.1 Min. Width of Conc. or Masonry Footings (inches) Smoke Alarms 2015 IRC Code Section R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the acuation of one alarm will activate all of the alarms S Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Carbon Monoxide Alarms 2015 IRC Section R315 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly Fasteners for Preservative treated wood 2015 IRC Code Section R402.1.1 Fastner for Preservative treated wood shall be of hot dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. Exceptions: 1. One-half inch (12.7mm) diameter or greater steel bolts. 2. Fasteners other than nail & timber rivets shall be permitted to be of mechanical deposited zinc coated steel with coating weights in accordance with ASTM B695 class 55 min. Frost Protection 403.1.4.1 Except where otherwise protected from frost, foundation walls, piers and other permanent supports of buildings and structures shall be protected from frost by one or more of the following methods: 1. Extended below the frost line specified in Table R301.2 2. Construct in accordance with Section 403.3 3. Construct in accordance with ASCE 32 or 4. Erected on Solid Rock Exceptions: -Protection of freestanding accessory structures with an area of 400 of 600 square feet or less, of light frame construction with an eve height of 10' of less shall not be required. -Decks not supported by a dwelling need not be provided with footings that extend below the frost line. -Footings shall not bear on frozen soil unless the frozen condition is permanent. Ventilation 2015 IRC Section R408 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. CM Basement Furring: F 8" Conc. Walls Not Required Not Required #6 at 36" O.C. Not Required Not Required #6 at 35" O.C. #6 at 32" O.C. Not Required #6 at 35" O.C. #6 at 34" O.C. Max. Wall Height 8' 9' 10' Max. Unbalanced Backfill Height 5' or less 6' 7' 5' or less 6' 7' 8' 7' or less 8' 9' 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8' and Greater (1) Horizontal Rebar in top 12" and one bar at each third point Min. Vertical Reiforcement Size & Spacing Table R404.1.2 (3) Reinforced Concrete Foundation Walls GM, GC, SM, SM-SC and ML 45 Soils Cross Section Roof System: 2015 IRC Code Section R801, R901 Architectural Grade, 25 year Asphalt Shingles R905 over #15 building felt over 7/16" Ext. OSB roof sheeting w/Clips & nailed 6" O.C.-Edges, 10" O.C.-field over 6:12 Pitch Engineered Trusses @ 24" O.C. (Framed According to Engineered Truss Layout) with R-49 Blown in Attic Insulation with 5/8" Sheet Rock on Interior Side Taped Prep'd for Interior Finishes Contractor to indicate 22"x30" Attic Access Location 2015 IRC Ice Protection Ice Barrier consisting of 2 layers of cemented under-layment and extend from the eave's edge 24" min. from inside exterior wall A E D B 12 21 32 12 16 24 12 12 16 12 12 12 S C Us e t h i s t a b l e u n l e s s a s o i l t e s t i s d o n e A5 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Bonus Room A5-Cross Section A6-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit SetBid Set TOTAL SQ. FTG.= 4556 MAIN FLOOR=1889/1785 INTERIOR SECOND FLOOR=770/710 INTERIOR BASEMENT=1897/1675 INTERIOR GARAGE=1074 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M 22" LAP (Typ) 22 " L A P (T Y P ) #4 @ 2'-0" O.C. E. W. 23/32 APA Rated Sheathing W/ Tar Paper Between Sheathing and Concrete Tar Paper 2x Pressure Treated Rim (Match Floor Joist Depth) #4 @ 2'-0" O.C. 24 2x4 Pressure Treated Sill Plate W/1/2" Dia. Anchor Bolts @ 4'-0" O.C. Wall Framing (By Others) Floor Framing (By Others) 1 1/4" (Min.) Eng Rim Joist Foundation Wall (By Others) Floor Joist (See Table) 2x Ledger W/Simpson 1/4" SDS Screws (Match Floor Joist Depth) (See Table) Simpson LUS Joist Hanger W/ SD Screws @ Each Joist Span (See Table) Slope Cold Storage Detail GENERAL STRUCTURAL NOTES A. CODES AND SPECIFICATIONS 1.International Building Code (IRC) - 2012 Edition 2.ACI 318-11 Building Code Requirements for Reinforced Concrete 3.ANSI/AF&PA National Design Specifications (NDS) & Suppl. for Wood Const. -2012 Edition 4.ASCE 7-10 Min. Design Loads for Buildings and other Structures B. DESIGN LOADS UNIFORM (PSF) 1.Floor Loads Uniform a. Deck Live = 100 C. MATERIALS 1. Dimensional Lumber #2 Douglas Fir 2. Concrete fc Slab 4000 PSi 3. Reinforcing Steel ASTM A615 - Grade 60 4. Anchor Bolts A36/F1554 GRADE 36 Span (See table) Le n g t h ( A s p e r A r c h D r a w i n g s 3'- 0 " Ma x . 4" Concrete Deck Table Span Joist Size Joist Spacing SDS 1/4 x 3 1/2 Screw Spacing 4'-0"2x4 16" O.C.8" O.C.6'-0"2x6 16" O.C.5" O.C. 8'-0"2x8 16" O.C.4" O.C. 6" Concrete Deck Table Span Joist Size Joist Spacing SDS 1/4 x 3 1/2 Screw Spacing 4'-0"2x4 16" O.C.7" O.C. 6'-0"2x6 16" O.C.4 1/2" O.C. 8'-0"2x8 12" O.C.3" O.C. Rev Rev A6 of Height of Braced Wall Panel SDC A,B, and C Windspeed <110 MPH Sheathed Width 2'-8"2'-8" MIN. WIDTHS AND TIE-DOWN FORCES OF ALTERNATE BRACED WALL PANELS Table R602.10.6.1 Tie-Down Force (lb.) 11 ft. 3'-2" 1800 3000 2200 3600 1800 3000 1800 3000 - -1 Seismic Design Category and Windspeed 2'-8" 8 ft. 2'-4" 9 ft. 2'-8" 10 ft. 2'-8" Note a 12 ft. 3'-6" R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 1800 3000 2000 3300 Sheathed Width SDC D,D, and D Windspeed <110 MPH R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 300002 Note a - -Scale: 1/4"=1'-0" UNO on 36"x24" Size Paper Scale: 1/8"=1'-0" UNO on 17"x11" Size Paper Rev Co o p e r Re s i d e n c e PE R M I T S E T 2015 IRC Code R602, R608, R703 Board and Batten and Faux Stone over Weather Resistive Barrier 7/16" APA OSB & Nailing Pattern 6"-edge 12"-field 2x6 Stud framed @ 24" O.C. UNO with (2) 2x6 Top Plates with (1) 2x6 Bottom Plate with min. R-21 Batt Insulation with 1/2" Sheetrock Inside Occupancy separation between between house, attic, and garage Taped Prep'd for Interior Finishes 2015 IRC Code 2x6 Fascia Board with style "D" Metal Drip Edge with 3/8" Soffit Sheeting with 3" Continuous Soffit Venting with add'l 2x4 Support as Required 2015 IRC Code 2x4 Stud framed @ 24" O.C. with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with 1/2" Sheetrock Both Sides Taped Prep'd for Interior Finishes 2015 IRC Code Section R502, R503, R504 3/4" T&G OSB Sub-floor Glued & Nailed over 11-7/8 TJI Engineered Floor Joist Series, Placement, & O.C. Spacing as determined & indicated on TJXpert Layout. (Version 6.0 or later) connected to Rim Joist, spliced using gal. metal ties not less than .058" x 1.5" wide fastened w/6 16d nails ea. side over 1/2" Sheetrock on Ceiling Side Taped and Prep'd for Interior Finishes 2015 IRC Code SectionR602.4 2x4 Stud Framed @ 24" O.C. with Bearing Walls @ 16" O.C. with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with R-13 Batt Insulation with 6-Mill Poly Vapor Barrier with 1/2" Sheetrock on Interior Side Taped and Prep'd for Interior Finishes (2) #4 Rebar Horiz. Cont. 5" Office B C D E F G (1) Horiz. Bar in top 12" and one bar at each third point 8" 9' 1'- 2 " 9' (2) #4 Rebar Horiz. Cont. (2) #4 Rebar Horiz. Cont. 8' 1' Stair System: 2015 IRC R302.7, 311.7.2, R311.7 R312.1.3 Eq. Stair Risers 7 3/4" Max. height, Eq. Stair Treads 10" Min. depth over (3) 11.5" MIN. Stair Stringers bolted at bottom with P.T. 2x4 -3 places with 3" x 12" Ø bolt and top securely mounted to framing with Simpson A35 Connector at Stairs Stringer to Ledger or alternate approved connection. with Cont. Handrail System mounted 36"above stair plane. with Handrail return to wall. with a Min. 6'-8" Head Clearance above stair plane. with all other Railing System to be min. 42" above FFL & meet current building codes for vert. and horiz. loading. Slate Spacing to no more than 4" sphere to pass thru. 12" Gypsum Board under stairs 2% Slope Max 1 to 48 H GFoundation Wall System: 2x6 Treated Sill Plate over Foam Sill Sealer with 12" Anchor Bolts @ 72" O.C. 10" Long, 7" Embedded Max. 12" from all Corners or Splices Concrete Wall Greater than 9' need to have an Architects or Engineer Seal 8' & under (1) Horiz. Bar in top 12" and one at mid-height 8'-1" to 9' (1) Horiz. Bar in top 12" & one bar at each third point Min. (2) Anchor Bolts per Sill Plate w/ nut & ROUND plate Washer 2 1/2 Ø x14" Min. For each Bolt over Concrete Foundation wall Consistent w/ 2015 IRC R401-403 With Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/ 2015 IRC Section R106.1 over Undisturbed Soil Window Well System: 2015 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. One egress ladder shall be provided within a window well of an unfinished basement J 17 x 1 1 07-27-2020 Cold Storage Mech./ Storage Family Room Stairs Great Room Stairs Cl Loft 12 6 08-11-2020 Fasten sheathing to header w 8d common or gal. box nails in 3" grid pattern as shown Header to jack-stud strap per table R602.10.6.4 on both sides of opening opposite side of sheathing Min. Length of panel per Table R602.10.5 Min. double 2x4 framing covered w min. 716" thick wood structual panel sheathing w 8d common or gal. box nails at 3" o.c. in framing (studs, blocking, and sills) TYP. Min. (2) 12" Dia. Anchor Bolts installed per R403.1.6 with 2"x2"x316" Plate Washers Min. Double 2x4 Post Typical Portal Frame Construction If needed, panel splice edges shall occur over & be nailed to common blocking w/in middle 24" of wall mid-height. One row of 3" o.c. nailing is req. in ea. panel edge Extent of HeaderSingle Portal Frame (One Braced Wall Panel) Extent of Header Double Portal Frame (Two Braced Wall Panels) Ma x H e i g h t 1 0 ' - 0 " Min. 3"x11 14" net header (Steel header prohibited) Ma x T o t a l W a l l H e i g h t 1 2 ' - 0 " Min. reinforcing of foundation, (1) #4 bar top & bottom of footing. Lap bars 15" min. Play Area 2'-18" finished width for single or double portal Alternate Braced Wall Panel Garage Portal Design CS-PF Figure R602.10.6.4 Pony Wall Height Min. Footing under opening is 12"x12" Tension Strap per Table 602.10.6.4 (On opposite side of Sheathing) Fasten Top Plate to header w/2 Rows of 16D sinker nails at 3" O.C. TYP Min. 716" Wood Structural Panel Sheating 26 ' 36 ' - 1 0 " 6'- 1 1 1 / 2 " 1'- 0 1 / 2 " 17 ' 15 ' - 1 1 1 / 2 " 27 ' - 2 " 28 ' - 2 " H (2) #4 Rebar Horiz. Cont. 3' 6'- 8 " 3'-6" 7 3 / 8 " 10" Head r o o m H e i g h t Hand r a i l H e i g h t 3' 6'- 8 " 3'-6" 7 1 7 / 3 2 " 10" Head r o o m H e i g h t Hand r a i l H e i g h t 9' A H 36 ' - 2 " (2) #4 Rebar Horiz. Cont. Plot Plan Scale: 1/8" =1'-0" D Size Paper Scale: 1/16"=1'-0" B Size Paper Pine Brook Div. No. 2, Block No. 6, Lot No. 2 Rexburg, Idaho Madison County A6 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Bonus Room A5-Cross Section A6-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit SetBid Set TOTAL SQ. FTG.= 4556 MAIN FLOOR=1889/1785 INTERIOR SECOND FLOOR=770/710 INTERIOR BASEMENT=1897/1675 INTERIOR GARAGE=1074 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A6 of Rev Co o p e r Re s i d e n c e PE R M I T S E T 17 x 1 1 07-27-2020 08-11-2020 30' Max 6 3 ' - 3 1 / 2 " 63'-3 1 / 2 " 61'- 9 " 6 1 ' - 9 " 44'-6"3'-10"10'-2"10'-4"9'6'11'-4"6'14'-4"44'-6" 4 2 ' - 1 0 " 8 ' 2 8 ' - 1 0 " 1 1 ' - 4 " 3 ' - 1 0 " 8 ' - 2 " 2 ' 4 5 ' 33'-6"15'8'14'-6"44'-6"44'-6" 8 ' 3 0 ' - 2 " 2 2 ' 2 ' 4 5 ' 4 2 ' - 1 0 " Location of New Construction 12'-4" 2 ' 7 ' - 1 0 " 6 ' 17'-10" 9 ' - 2 " 22'-6" 2 5 ' 94'-4 1 / 2 " 9 4 ' - 4 1 / 2 " NORTH Line of Required Setback 160.00' S 89° 59' 46" W 160.00' N 89° 59' 46" E 15 0 . 0 0 ' S 0 ° 0 ' 1 4 " E 15 0 . 0 0 ' N 0 ° 0 ' 1 4 " W