Loading...
HomeMy WebLinkAboutCOMCHECK ELECTRICAL - 20-00520 - Harbor Freight ToolsCOMcheck Software Version 4.1.3.0 Interior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:Alteration Construction Site: 530 North 2nd East Street Rexburg, ID 83440 Owner/Agent: Adam Steece Harbor Freight Tools 26541 Agoura Road Calabasas, CA 91302 Designer/Contractor: Brian Schuler 17710 Detroit Ave Lakewood, OH 44107 Project Information Energy Code: Harbor Freight Tools Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Sales (Retail:Sales Area)9443 1.59 15014 2-Stock (Common Space Types:Storage >=1000 sq.ft.)5670 0.63 3572 3-Managers Office (Common Space Types:Office - Enclosed)128 1.11 142 4-Cash Office (Common Space Types:Office - Enclosed)128 1.11 142 5-Mens Restroom (Common Space Types:Restrooms)70 0.98 69 6-Womens Restroom (Common Space Types:Restrooms)70 0.98 69 7-Breakroom (Common Space Types:Lounge/Breakroom)155 0.73 113 19121Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Sales ( Retail:Sales Area 9443 sq.ft.) LED 1: C,CE: 1'x8' Strip Fixture: LED Other Fixture Unit 80W:1 98 100 9800 LED 3: B,BE: 2'x4' Recessed Fixture: LED Other Fixture Unit 36W:1 2 36 72 LED 10: C1,C1E: 1x4' Strip Fixture: LED Other Fixture Unit 50W:1 2 50 100 Stock ( Common Space Types:Storage >=1000 sq.ft. 5670 sq.ft.) LED 4: D,DE: 1'x8' Strip Fixture: LED Other Fixture Unit 80W:1 26 100 2600 Managers Office ( Common Space Types:Office - Enclosed 128 sq.ft.) LED 6: A,AE: 2'x4' Recessed Fixture: LED Other Fixture Unit 60W:1 2 59 118 Cash Office ( Common Space Types:Office - Enclosed 128 sq.ft.) LED 7: A,AE: 2'x4' Recessed Fixture: LED Other Fixture Unit 60W:1 2 59 118 Mens Restroom ( Common Space Types:Restrooms 70 sq.ft.) LED 8: B,BE: 2'x4' Recessed Fixture: LED Other Fixture Unit 36W:1 1 36 36 Womens Restroom ( Common Space Types:Restrooms 70 sq.ft.) LED 9: B,BE: 2'x4' Recessed Fixture: LED Other Fixture Unit 36W:1 1 36 36 Breakroom ( Common Space Types:Lounge/Breakroom 155 sq.ft.) LED 10: B,BE: 2'x4' Recessed Fixture: LED Other Fixture Unit 36W:1 3 36 108 12988Total Proposed Watts = Project Title: Data filename: Harbor Freight Tools M:\Harbor Freight\20142 Rexburg, ID\K- Electrical\HFT.cck 07/01/20Report date: 61 ofPage Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.3.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: Harbor Freight Tools M:\Harbor Freight\20142 Rexburg, ID\K- Electrical\HFT.cck 07/01/20Report date: 62 ofPage Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.3.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Harbor Freight Tools M:\Harbor Freight\20142 Rexburg, ID\K- Electrical\HFT.cck 07/01/20Report date: 63 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.1 [EL15]1 Lighting controls installed to uniformly reduce the lighting load by at least 50%. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1 [EL18]1 Occupancy sensors installed in required spaces. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1, C405.2.2. 3 [EL23]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.2. 1 [EL22]2 Automatic controls to shut off all building lighting installed in all buildings. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.3 [EL16]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.3, C405.2.3. 1, C405.2.3. 2 [EL20]1 Primary sidelighted areas are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.3, C405.2.3. 1, C405.2.3. 3 [EL21]1 Enclosed spaces with daylight area under skylights and rooftop monitors are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. C405.2.4 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.4 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Harbor Freight Tools M:\Harbor Freight\20142 Rexburg, ID\K- Electrical\HFT.cck 07/01/20Report date: 64 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.4.1 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C408.2.5. 1 [FI16]3 Furnished as-built drawings for electric power systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.3 [FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Harbor Freight Tools M:\Harbor Freight\20142 Rexburg, ID\K- Electrical\HFT.cck 07/01/20Report date: 65 ofPage Project Title: Data filename: Harbor Freight Tools M:\Harbor Freight\20142 Rexburg, ID\K- Electrical\HFT.cck 07/01/20Report date: 66 ofPage