HomeMy WebLinkAboutCOMCHECK ELECTRICAL - 20-00520 - Harbor Freight ToolsCOMcheck Software Version 4.1.3.0
Interior Lighting Compliance Certificate
Project Title:
2015 IECC
Project Type:Alteration
Construction Site:
530 North 2nd East Street
Rexburg, ID 83440
Owner/Agent:
Adam Steece
Harbor Freight Tools
26541 Agoura Road
Calabasas, CA 91302
Designer/Contractor:
Brian Schuler
17710 Detroit Ave
Lakewood, OH 44107
Project Information
Energy Code:
Harbor Freight Tools
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed Watts
(B X C)
1-Sales (Retail:Sales Area)9443 1.59 15014
2-Stock (Common Space Types:Storage >=1000 sq.ft.)5670 0.63 3572
3-Managers Office (Common Space Types:Office - Enclosed)128 1.11 142
4-Cash Office (Common Space Types:Office - Enclosed)128 1.11 142
5-Mens Restroom (Common Space Types:Restrooms)70 0.98 69
6-Womens Restroom (Common Space Types:Restrooms)70 0.98 69
7-Breakroom (Common Space Types:Lounge/Breakroom)155 0.73 113
19121Total Allowed Watts =
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
Sales ( Retail:Sales Area 9443 sq.ft.)
LED 1: C,CE: 1'x8' Strip Fixture: LED Other Fixture Unit 80W:1 98 100 9800
LED 3: B,BE: 2'x4' Recessed Fixture: LED Other Fixture Unit 36W:1 2 36 72
LED 10: C1,C1E: 1x4' Strip Fixture: LED Other Fixture Unit 50W:1 2 50 100
Stock ( Common Space Types:Storage >=1000 sq.ft. 5670 sq.ft.)
LED 4: D,DE: 1'x8' Strip Fixture: LED Other Fixture Unit 80W:1 26 100 2600
Managers Office ( Common Space Types:Office - Enclosed 128 sq.ft.)
LED 6: A,AE: 2'x4' Recessed Fixture: LED Other Fixture Unit 60W:1 2 59 118
Cash Office ( Common Space Types:Office - Enclosed 128 sq.ft.)
LED 7: A,AE: 2'x4' Recessed Fixture: LED Other Fixture Unit 60W:1 2 59 118
Mens Restroom ( Common Space Types:Restrooms 70 sq.ft.)
LED 8: B,BE: 2'x4' Recessed Fixture: LED Other Fixture Unit 36W:1 1 36 36
Womens Restroom ( Common Space Types:Restrooms 70 sq.ft.)
LED 9: B,BE: 2'x4' Recessed Fixture: LED Other Fixture Unit 36W:1 1 36 36
Breakroom ( Common Space Types:Lounge/Breakroom 155 sq.ft.)
LED 10: B,BE: 2'x4' Recessed Fixture: LED Other Fixture Unit 36W:1 3 36 108
12988Total Proposed Watts =
Project Title:
Data filename:
Harbor Freight Tools
M:\Harbor Freight\20142 Rexburg, ID\K- Electrical\HFT.cck
07/01/20Report date:
61 ofPage
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.3.0 and to comply with any
applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Interior Lighting PASSES
Project Title:
Data filename:
Harbor Freight Tools
M:\Harbor Freight\20142 Rexburg, ID\K- Electrical\HFT.cck
07/01/20Report date:
62 ofPage
Inspection Checklist
Requirements: 100.0% were addressed directly in the COMcheck software
COMcheck Software Version 4.1.3.0
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2015 IECC
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
C103.2
[PR4]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the interior lighting
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Harbor Freight Tools
M:\Harbor Freight\20142 Rexburg, ID\K- Electrical\HFT.cck
07/01/20Report date:
63 ofPage
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
C405.2.1
[EL15]1
Lighting controls installed to uniformly
reduce the lighting load by at least
50%.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.2.1
[EL18]1
Occupancy sensors installed in
required spaces.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.2.1,
C405.2.2.
3
[EL23]2
Independent lighting controls installed
per approved lighting plans and all
manual controls readily accessible and
visible to occupants.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.2.2.
1
[EL22]2
Automatic controls to shut off all
building lighting installed in all
buildings.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.2.3
[EL16]2
Daylight zones provided with
individual controls that control the
lights independent of general area
lighting.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.2.3,
C405.2.3.
1,
C405.2.3.
2
[EL20]1
Primary sidelighted areas are
equipped with required lighting
controls.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.2.3,
C405.2.3.
1,
C405.2.3.
3
[EL21]1
Enclosed spaces with daylight area
under skylights and rooftop monitors
are equipped with required lighting
controls.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
C405.2.4
[EL4]1
Separate lighting control devices for
specific uses installed per approved
lighting plans.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.2.4
[EL8]1
Additional interior lighting power
allowed for special functions per the
approved lighting plans and is
automatically controlled and
separated from general lighting.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.3
[EL6]1
Exit signs do not exceed 5 watts per
face.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Harbor Freight Tools
M:\Harbor Freight\20142 Rexburg, ID\K- Electrical\HFT.cck
07/01/20Report date:
64 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
C303.3,
C408.2.5.
2
[FI17]3
Furnished O&M instructions for
systems and equipment to the
building owner or designated
representative.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C405.4.1
[FI18]1
Interior installed lamp and fixture
lighting power is consistent with what
is shown on the approved lighting
plans, demonstrating proposed watts
are less than or equal to allowed
watts.
Complies
Does Not
Not Observable
Not Applicable
See the Interior Lighting fixture schedule for values.
C408.2.5.
1
[FI16]3
Furnished as-built drawings for
electric power systems within 90 days
of system acceptance.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
C408.3
[FI33]1
Lighting systems have been tested to
ensure proper calibration, adjustment,
programming, and operation.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Harbor Freight Tools
M:\Harbor Freight\20142 Rexburg, ID\K- Electrical\HFT.cck
07/01/20Report date:
65 ofPage
Project Title:
Data filename:
Harbor Freight Tools
M:\Harbor Freight\20142 Rexburg, ID\K- Electrical\HFT.cck
07/01/20Report date:
66 ofPage