Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 10-00054 - 370 W 7th S - South Gate Apts 12 Plex - Phase 1Permit Inspection Summary Permit Status of (Open) as of Report Date: 06/30/2020 11:35 am Permit Details Permit Number: 10-00054 370 W 7th S - South Gate Apts 12 Plex - Phase 1 370 W 7th S New Multi-Family Residence Permit Issued Date: 12/12/2014 Permit Inspection Statistics 27Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 62.96% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 04/02/2010PassTed DyeResidential Footing Inspection 4/2/10 - Correct rebar. Grade good. Ufer grounds (2) installed east end. 4/19/10 - Approved to place concrete- interior footings per BretS Inspector Comments: 04/06/2010PassPLL ADMINFoundation Inspection As per Jon Berry W, E, and South foundations and rebar look good. Inspector Comments: 05/03/2010FailPLL ADMINResidential Framing/Structure Inspection As per Jon Berry Finish attic draft stops Drywall behind tubs at 1hr separation walls before installation. Plans show int. fire separation wall 2 layers drywall 1" gad. Center bearing walls required anchor bolts. Inspector Comments: 05/07/2010FailPLL ADMINResidential Framing/Structure Inspection As per Jon Berry Interior soffits not constructed as per plans. Center party wall is not as shown on plans CW Anchor bolts req'd in center party walls CW Finish installing second floor straps CW 5/8's Type X drywall required on center party walls and unit dividing walls 1/2" ok'd by Val and architect per chapter 21 IBC 5/8's Type X required on 2nd floor truss ceiling for separation Inspector Comments: 05/19/2010FailPLL ADMINResidential Insulation Inspection As per Jon Berry 101,102,104,106,108,110,112 NOT completed. Other units OK to drywall. Inspector Comments: 05/25/2010PassPLL ADMINResidential Framing/Structure Inspection As per Jon BerryInspector Comments: Page 1 of 4 (Continued) Permit Details Permit Number: 10-00054 370 W 7th S - South Gate Apts 12 Plex - Phase 1 370 W 7th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 06/30/2020 11:35 am Permit Inspection Summary 05/25/2010PassPLL ADMINResidential Insulation Inspection As per Jon Berry. Completed including fire wrap around washer box Inspector Comments: 05/28/2010PassPLL ADMINResidential Sheetrock/Drywall Inspection As per Jon Berry. 5/26/10 - Drywall completed on east 6 units and southwest units. Northwest 3 units NCW in work. 5/27/10 - Not completed (Did not inspect) 5/24/10 - Nailing looks good. OK to cover above units. (105-108) 5/28/10 - Building 1 drywall OK to cover. Inspector Comments: 08/09/2010FailPLL ADMINResidential Building Final Insol density deport. Mount fire extinguisher in kitchen area. Fire caulk drain pips in partywalls. 2 hand rails required on stairs. Fire caulk water shut off valves in mech room. Inspector Comments: 08/18/2010FailPLL ADMINResidential Building Final As per Jon Berry. 107/204 Furnace reg, not vented. 109,204. 208, 212, 207, 205 furnace wire not caulked. 1st floor toilet water needs fire caulk. Numbers and 403. Finish taping mech room. and cover tape. 211 smoke det. does not talk. Stair light missing 301, 411. Smoke hanging not tested 406, 408. Numbers missing on units building 3,4. Vanity drains not fire caulked. Inspector Comments: 09/07/2010PassPLL ADMINSidewalk Inspection As per Jon Berry.Inspector Comments: 09/07/2010PassPLL ADMINResidential Building Final As per Jon Berry. 101 tape behind furnace. Approved. Inspector Comments: Page 2 of 4 (Continued) Permit Details Permit Number: 10-00054 370 W 7th S - South Gate Apts 12 Plex - Phase 1 370 W 7th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 06/30/2020 11:35 am Permit Inspection Summary Electrical 05/17/2010PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-inspected these services on the rough-in and there is no seperate ticket written for the services(3). Inspector Comments: 07/02/2010PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 5/17/10 - Approved for cover in units #101-112. 7/2/10 - Approved for cover in the doghouse on this building-inspected this for cover on the final of this building-no ticket written. Inspector Comments: 07/02/2010FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Clearance not sufficient for panel 109- furnace. Approved for a final in all units except doghouse and 109. Inspector Comments: 08/18/2010FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection A/C units - romex changed to wet location Bar lights- Romex connection. Inspector Comments: 08/25/2010PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.Inspector Comments: Fire 09/03/2010N/APLL ADMINFire Department Final Inspection As per Jon Berry.Inspector Comments: Page 3 of 4 (Continued) Permit Details Permit Number: 10-00054 370 W 7th S - South Gate Apts 12 Plex - Phase 1 370 W 7th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 06/30/2020 11:35 am Permit Inspection Summary Mechanical As per Jon Berry 60# for all Apts. Inspector Comments: 05/13/2010FailPLL ADMINHVAC Rough-in As per Jon Berry Ducting in attic has to be changed to metal from flex or fire dampers installed due to attic shared with another unit. Inside the units look good. Inspector Comments: 05/13/2010PassPLL ADMINHVAC Rough-in As per Jon Berry All units building 1 look good. *approved Inspector Comments: 06/18/2010FailPLL ADMINHVAC Final Inspection As per Jon Berry. Vent gas regulators CW Evap units need furnace shut off device for secondary overflow. CW Inspector Comments: 07/02/2010PassPLL ADMINHVAC Final Inspection As per Jon Berry. 7/1/10 - Building 1 HVAC final completed. Inspector Comments: Plumbing 04/14/2010PassPLL ADMINPlumbing Underground Inspection As per Brad Johnson.Inspector Comments: 04/19/2010PassPLL ADMINPlumbing Water As per Brad Johnson.Inspector Comments: 05/11/2010PassPLL ADMINPlumbing Sewer As per Brad Johnson.Inspector Comments: 05/11/2010PassPLL ADMINPlumbing Rough-in As per Brad Johnson.Inspector Comments: 08/03/2010PassPLL ADMINPlumbing Final Inspection As per Bradley Johnson. Approved for final on plumbing on building #1 only. Approved for plumbing building #2 only. Inspector Comments: Page 4 of 4