HomeMy WebLinkAboutINSPECTION SUMMARY - 10-00054 - 370 W 7th S - South Gate Apts 12 Plex - Phase 1Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 06/30/2020 11:35 am
Permit Details Permit Number: 10-00054
370 W 7th S - South Gate Apts 12 Plex - Phase 1
370 W 7th S
New Multi-Family Residence
Permit Issued Date: 12/12/2014
Permit Inspection Statistics
27Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 62.96%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building
04/02/2010PassTed DyeResidential Footing Inspection
4/2/10 - Correct rebar. Grade good. Ufer grounds (2) installed east end.
4/19/10 - Approved to place concrete- interior footings per BretS
Inspector Comments:
04/06/2010PassPLL ADMINFoundation Inspection
As per Jon Berry
W, E, and South foundations and rebar look good.
Inspector Comments:
05/03/2010FailPLL ADMINResidential Framing/Structure Inspection
As per Jon Berry
Finish attic draft stops
Drywall behind tubs at 1hr separation walls before installation.
Plans show int. fire separation wall 2 layers drywall 1" gad.
Center bearing walls required anchor bolts.
Inspector Comments:
05/07/2010FailPLL ADMINResidential Framing/Structure Inspection
As per Jon Berry
Interior soffits not constructed as per plans.
Center party wall is not as shown on plans CW Anchor bolts req'd in center party
walls CW Finish installing second floor straps CW 5/8's Type X drywall required on
center party walls and unit dividing walls 1/2" ok'd by Val and architect per
chapter 21 IBC 5/8's Type X required on 2nd floor truss ceiling for separation
Inspector Comments:
05/19/2010FailPLL ADMINResidential Insulation Inspection
As per Jon Berry
101,102,104,106,108,110,112 NOT completed.
Other units OK to drywall.
Inspector Comments:
05/25/2010PassPLL ADMINResidential Framing/Structure Inspection
As per Jon BerryInspector Comments:
Page 1 of 4
(Continued)
Permit Details Permit Number: 10-00054
370 W 7th S - South Gate Apts 12 Plex - Phase 1
370 W 7th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 06/30/2020 11:35 am
Permit
Inspection
Summary
05/25/2010PassPLL ADMINResidential Insulation Inspection
As per Jon Berry.
Completed including fire wrap around washer box
Inspector Comments:
05/28/2010PassPLL ADMINResidential Sheetrock/Drywall Inspection
As per Jon Berry.
5/26/10 - Drywall completed on east 6 units and southwest units. Northwest 3
units NCW in work.
5/27/10 - Not completed (Did not inspect)
5/24/10 - Nailing looks good. OK to cover above units. (105-108)
5/28/10 - Building 1 drywall OK to cover.
Inspector Comments:
08/09/2010FailPLL ADMINResidential Building Final
Insol density deport.
Mount fire extinguisher in kitchen area.
Fire caulk drain pips in partywalls.
2 hand rails required on stairs.
Fire caulk water shut off valves in mech room.
Inspector Comments:
08/18/2010FailPLL ADMINResidential Building Final
As per Jon Berry.
107/204 Furnace reg, not vented.
109,204. 208, 212, 207, 205 furnace wire not caulked.
1st floor toilet water needs fire caulk.
Numbers and 403.
Finish taping mech room. and cover tape.
211 smoke det. does not talk.
Stair light missing 301, 411.
Smoke hanging not tested 406, 408.
Numbers missing on units building 3,4. Vanity drains not fire caulked.
Inspector Comments:
09/07/2010PassPLL ADMINSidewalk Inspection
As per Jon Berry.Inspector Comments:
09/07/2010PassPLL ADMINResidential Building Final
As per Jon Berry.
101 tape behind furnace.
Approved.
Inspector Comments:
Page 2 of 4
(Continued)
Permit Details Permit Number: 10-00054
370 W 7th S - South Gate Apts 12 Plex - Phase 1
370 W 7th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 06/30/2020 11:35 am
Permit
Inspection
Summary
Electrical
05/17/2010PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-inspected these services on the
rough-in and there is no seperate ticket written for the services(3).
Inspector Comments:
07/02/2010PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
5/17/10 - Approved for cover in units #101-112.
7/2/10 - Approved for cover in the doghouse on this building-inspected this for
cover on the final of this building-no ticket written.
Inspector Comments:
07/02/2010FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Clearance not sufficient for panel 109- furnace.
Approved for a final in all units except doghouse and 109.
Inspector Comments:
08/18/2010FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
A/C units - romex changed to wet location
Bar lights- Romex connection.
Inspector Comments:
08/25/2010PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.Inspector Comments:
Fire
09/03/2010N/APLL ADMINFire Department Final Inspection
As per Jon Berry.Inspector Comments:
Page 3 of 4
(Continued)
Permit Details Permit Number: 10-00054
370 W 7th S - South Gate Apts 12 Plex - Phase 1
370 W 7th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 06/30/2020 11:35 am
Permit
Inspection
Summary
Mechanical
As per Jon Berry
60# for all Apts.
Inspector Comments:
05/13/2010FailPLL ADMINHVAC Rough-in
As per Jon Berry
Ducting in attic has to be changed to metal from flex or fire dampers installed
due to attic shared with another unit. Inside the units look good.
Inspector Comments:
05/13/2010PassPLL ADMINHVAC Rough-in
As per Jon Berry
All units building 1 look good.
*approved
Inspector Comments:
06/18/2010FailPLL ADMINHVAC Final Inspection
As per Jon Berry.
Vent gas regulators CW Evap units need furnace shut off device for secondary
overflow. CW
Inspector Comments:
07/02/2010PassPLL ADMINHVAC Final Inspection
As per Jon Berry.
7/1/10 - Building 1 HVAC final completed.
Inspector Comments:
Plumbing
04/14/2010PassPLL ADMINPlumbing Underground Inspection
As per Brad Johnson.Inspector Comments:
04/19/2010PassPLL ADMINPlumbing Water
As per Brad Johnson.Inspector Comments:
05/11/2010PassPLL ADMINPlumbing Sewer
As per Brad Johnson.Inspector Comments:
05/11/2010PassPLL ADMINPlumbing Rough-in
As per Brad Johnson.Inspector Comments:
08/03/2010PassPLL ADMINPlumbing Final Inspection
As per Bradley Johnson.
Approved for final on plumbing on building #1 only.
Approved for plumbing building #2 only.
Inspector Comments: