HomeMy WebLinkAboutCONCRETE TEST 8 - 19-00733 - The Grove at Thomson Farms - Hemlock - 30 Unit Bldg 2Project Name:
Client:
Mix Number:
Project Number:
Ticket Number:
Load Amount:
Admixtures:
Tested By:
Date and Time:
Compressive Strength of Concrete Test Specimens
Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511)
Slump (Inches):
Entrained Air (%):
Concrete Temperature:
Ambient Temperature:
Test Results:Minimum:Maximum:
Cylinder #
Lab Test Data: (ASTM C39, C42, C617, and C1231)
Break Age
Cylinder
Diameter (in)
Area
(in² )
Break
Date
Maximum Load
(lbs)
Break
Type
Compressive
Strength (psi)Required 28 day
Strength (psi)
°F
°F
Reviewed By:
Supplier:
Test Location:
Unit Weight (PCF):Set # :
Cylinders Picked Up By: Date and Time:
Hi / Low Temperatures
Remarks:
28-day Average Strength
Thomson Farms
Still Water Equity Partnership
183
20001
13302
11
MP 322, MA AE 90
L. Camarillo
04/28/2020 5:30 PM
7.5
5.6
65.4
72
8
5 7
56A
56E
56C
56B
56D
4 05/05/20
05/26/20
05/26/20
05/26/20
05/26/20
39,325 4 3,0003,12812.57
Walters Ready Mix
Footings for east side of building 8.
7
28
28
28
H
Walters Ready Mix added 80 oz. of plasticizer at batch
plant.
2/2