Loading...
HomeMy WebLinkAboutSOIL DENSITY 3 - 19-00736 - The Grove at Thomson Farms - Linden - 30 Unit Bldg 7In Place Density of Soils ASTM D2922 & D3017 Project Name: Project Number: Client: Contractor: Date:Tested By: Time Start:Time End: Instrument ID Daily Standardization:MS:DS: Test Number Depth: Elevation:% M: Proctor: % of Proctor: Test Number Test Number Test Number Test Number Test Location: Elevation: Material Type: % of Proctor: Proctor: % M: Dry: Wet: % of Proctor: Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: % of Proctor: Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: % of Proctor: Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: % of Proctor: Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: % of Proctor: Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: Reviewed By: Remarks: Page 1 of 2 Depth: Depth: Depth: Depth: Depth: Depth: Pass Fail Dry: Wet:Test Location: Material Type: FailPass FailPass Pass Fail FailPass FailPass FailPass Test Number Test Number лйсͨтрйͨплмрϝϝϝͨωϕϔϔϋωϚϋϔύϘͨωϕϓнкймΎпйоΗΜϛϏϚϋкΛϏύψϟͥΒ΍смннл Thompson Farms 20001 Stillwater Equity Partners Hill and Son Excavation 05-04-2020 F Pelton 9:00,1:30 12:00, 4:00 76562 672 2801 101 ft below bottom of footing 6.1 132 95% Approximately 1.8 and E.5 of Building 11. 1 ft below bottom of footing Pit Run 95% 132 7 125.1 133.9 97% 132 4.6 128.5 134.4 Pit Run 1 ft below bottom of footing Approximately 1.2 and D.5 of Building 11. 97% 132 3.7 127.6 132.3 Pit Run 1 ft below bottom of footing Approximately 1.2 and B.5 of Building 11. 98% 132 3.9 129.4 134.5 Pit Run 1 ft below bottom of footing Approximately 2.5 and D.5 of Building 11. 96% 132 6.1 127.1 134.9 Pit Run 1 ft below bottom of footing Approximately 3.6 and A.25 of Building 11. 97% 132 4.5 127.7 133.4 Pit Run 1 ft below bottom of footing Approximately 3.4 and B.5 of Building 11. Digitally signed by Jacob P Christensen Date: 2020.05.08 11:22:57 -06'00' 10 10 8 10 10 10 1 125 133Approximately 3.4 and E.5 of Building 11. Pit Run 5 6 7 2 3 4 Test Number % of Proctor: Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: Proctor: % of Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: Proctor: % of Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: Proctor: % of Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: Proctor: % of Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: Proctor: % of Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: Proctor: % of Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: Proctor: % of Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: Proctor: % of Proctor: % M:Elevation: Wet:Test Location: Material Type: Dry: Page 2 of 2 % of Proctor: Proctor: % M: Dry: Wet: Material Type: Elevation: Test Location: Depth: Depth: Depth: Depth: Depth: Depth: Depth: Depth: Depth: Depth: FailPass Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Test Number Test Number Test Number Test Number Test Number Test Number Test Number Test Number Test Number 97% 132 5.2 128.3 135 Pit Run 1 ft below bottom of footing Approximately 3.9 and C.5 of Building 11. 132 95% 6.4 125.4 133.4 Pit Run 1 ft below bottom of footing Approximately 3.9 and C.5 of Building 11. 132 95% 5.3 125.4 132.4 Pit Run 1 ft below bottom of footing Approximately 3.9 and C.5 of Building 11. 132 95% 5.3 125.8 132.5 Pit Run 1 ft below bottom of footing Approximately 2.5 and A.25 of Building 11. 10 10 10 10 8 11 9 10