HomeMy WebLinkAboutINSPECTION SUMMARY - 10-00069 - South Gate Apts - Clubhouse - Bld #1Permit Inspection Summary Permit Status of (Open) as of Report Date: 06/29/2020 9:28 am Permit Details Permit Number: 10-00069 South Gate Apts - Clubhouse - Bld #1 370 W 7th S New Commercial Building Permit Issued Date: 12/17/2014 Permit Inspection Statistics 25Total Inspections Completed: 18Total Inspections Passed: Inspection Pass Rate: 72.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 05/10/2010PassPLL ADMINCommercial Footing Inspection As per Jon Berry. Footing looks good. Inspector Comments: 05/11/2010PassPLL ADMINFoundation Inspection As per Jon Berry Foundation looks good. Inspector Comments: 06/18/2010FailPLL ADMINCommercial Framing/Structure Inspection As per Jon Berry. 6/15/10 - Could not inspect. Mech, Elec, and Plumbing not completed. 6/18/10 - Straps and nailing as noted on drawing. Basement bearing walls need anchor bolts. Apt. steps rise not to code or plans. Inspector Comments: 07/09/2010FailPLL ADMINCommercial Framing/Structure Inspection As per Jon Berry. Residential stairs still not to code. Bearing basement walls still need anchor bolts. Inspector Comments: 07/15/2010FailPLL ADMINCommercial Framing/Structure Inspection As per Jon Berry. Residential stairs still are not per code tread. The rest of the building passed. Inspector Comments: 07/19/2010PassPLL ADMINCommercial Insulation Inspection As per Jon Berry. Exterior walls insulation both floors look good. Inspector Comments: 07/21/2010PassPLL ADMINCommercial Sheetrock/Drywall Inspection As per Jon Berry. Apartment upstairs of club house drywall ok to tape. Washer box in apt needs 2A rating. Basement drywall OK to cover. 7/22/10 Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 10-00069 South Gate Apts - Clubhouse - Bld #1 370 W 7th S New Commercial Building Permit Status of (Open) as of Report Date: 06/29/2020 9:28 am Permit Inspection Summary 07/28/2010PassPLL ADMINCommercial Framing/Structure Inspection As per Jon Berry. 7/19/10 - Framing completed on club house. 7/28/10 - Fire caulking around washer box in residence completed. Inspector Comments: 08/31/2010PassPLL ADMINSidewalk Inspection As per Jon Berry.Inspector Comments: 08/31/2010FailPLL ADMINCommercial Building Final As per Jon Berry. Ladders req'd in window wells cw 1 1/2 hour rated door required between apt and clubhouse. inw CW kitchen stove warming only sign CW range hood not insp cw No ada grab bars cw Inspector Comments: 09/07/2010FailPLL ADMINCommercial Building Final As per Jon Berry. 90 min door needed for apt Inspector Comments: 09/20/2010PassPLL ADMINCommercial Building Final OK per Jon Berry.Inspector Comments: Electrical 07/12/2010PassBret StoddardCommercial Electrical Rough-in Approved for cover in the entire building, ground rods installed and also nail plates, grounding electrode conductor not continuous-need to install continuous conductor-will re-inspect this on the final. Inspected this on the 9th last week and they were not done. Inspector Comments: 07/13/2010PassBret StoddardCOM & MFR Electrical Service Inspection Approved to be energized for permanent power-500 and 501.Inspector Comments: 08/26/2010FailBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Need to install a box for the theatre cabinet, need to install the hood fan for the range, call for a re-inspect when ready. Inspector Comments: 09/08/2010PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection 8/20/10 - Approved for a final and a C.O. in the managers unit only. 9/8/10 - Approved for a final and a C.O. Inspector Comments: Fire 09/17/2010PassPLL ADMINFire Department Final Inspection As per Jon Berry. 7/19/10 - Attic fire stop looks good. 9/17/10 - Fire door installed (90 min) Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 10-00069 South Gate Apts - Clubhouse - Bld #1 370 W 7th S New Commercial Building Permit Status of (Open) as of Report Date: 06/29/2020 9:28 am Permit Inspection Summary Mechanical 07/19/2010PassPLL ADMINHVAC Rough-in As per Jon Berry. HVAC rough looks good. Inspector Comments: 08/19/2010FailPLL ADMINHVAC Final Inspection As per Jon Berry. No access to attic furnaces. Inspector Comments: 08/26/2010PassPLL ADMINHVAC Final Inspection As per Jon Berry. HVAC final completed. Inspector Comments: Plumbing 05/10/2010PassPLL ADMINPlumbing Sewer As per Brad Johnson.Inspector Comments: 05/10/2010PassPLL ADMINPlumbing Water As per Brad Johnson.Inspector Comments: 05/27/2010PassSAUREY AMANDAPlumbing Underground Inspection Ground Rough for clubhouse was good; lift station, end of line, and test were all good. Per Jeff Hackworth. Inspector Comments: 06/22/2010PassSAUREY AMANDAPlumbing Rough-in Rough In CompleteInspector Comments: 08/31/2010PassPLL ADMINPlumbing Final Inspection As per Brad Johnson.Inspector Comments: Page 3 of 3