HomeMy WebLinkAboutINSPECTION SUMMARY - 10-00084 - 428 S 4th E - SFR AdditionPermit
Inspection
Summary
Permit Status of (Expired) as of Report Date: 06/29/2020 9:11 am
Permit Details Permit Number: 10-00084
428 S 4th E - SFR Addition
428 S 4th E
Single Family - Addition
Permit Issued Date: 04/18/2014
Permit Inspection Statistics
15Total Inspections Completed:
12Total Inspections Passed:
Inspection Pass Rate: 80.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building
04/09/2010PassTed DyeFooting Inspection
04/14/2010PassTed DyeFoundation Inspection
Rebar looked goodInspector Comments:
05/10/2010PassTed DyeSheeting
05/14/2010PassTed DyeFraming/Structure Inspection
structure looks good but electrical, plumbing, and hvac have not been finishedInspector Comments:
12/13/2010N/ATed DyeInsulation Inspection
No inspection called for, approved to close permit.Inspector Comments:
02/11/2011PassTed DyeSheetrock/Drywall Inspection
Partial inspection
Main rooms upstairs and 2 bedrooms downstairs look good.
OK to tape.
Call when the rest of drywall is complete.
2/11 Drywall completed
Inspector Comments:
02/14/2011FailPLL ADMINBuilding Final
Handrail needed on stairs
As per Jon Berry.
Inspector Comments:
Electrical
05/20/2010PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover-addition.Inspector Comments:
02/08/2011FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Need to mount the receptacle for the sump pump and install a cover on it, light
switch needs a cover in the sump pump room, receptacle not mounted in the
kitchen area-counter, junction box under the deck is not weather rated, A/C unit
wire needs a disconnect mounted to terminate in, hot tub not GFCI protected,
call for a re-inspect when ready.
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 10-00084
428 S 4th E - SFR Addition
428 S 4th E
Single Family - Addition
Permit Status of (Expired) as of Report Date: 06/29/2020 9:11 am
Permit
Inspection
Summary
Mechanical
05/18/2010PassPLL ADMINHVAC Rough-in
2 fire places in addition
Approved as per Jon Berry.
Inspector Comments:
02/11/2011PassPLL ADMINHVAC Final Inspection
HVAC final completed
As per Jon Berry.
Inspector Comments:
Plumbing
04/09/2010PassPLL ADMINPlumbing Sewer
As per Brad JohnsonInspector Comments:
04/09/2010PassPLL ADMINPlumbing Water
As per Brad JohnsonInspector Comments:
05/25/2010PassPLL ADMINPlumbing Rough-in
Rough Plumbing on addition was good, test was on and holding. Cleared for
cover up with Sheetrock. Per Jeff Hackworth.
Inspector Comments:
02/11/2011PassPLL ADMINPlumbing Final Inspection
Approved for plumbing final
As per Brad Johnson.
Inspector Comments:
Inspections Required
Building Final
SFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Page 2 of 2