Permit Status of (Open) as of Report Date: 06/29/2020 8:57 am
Permit Details Permit Number: 10-00097
Summerfield Townhomes - 4-plex
2459, 2453, 2447, 2441 W 960 S
New Single Family Residence
Permit Issued Date:
Permit Inspection Statistics
22Total Inspections Completed:
15Total Inspections Passed:
Inspection Pass Rate: 68.18%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building
04/20/2010PassTed DyeResidential Footing Inspection
04/22/2010PassTed DyeFoundation Inspection
06/02/2010PassTed DyeSheeting
06/16/2010FailTed DyeResidential Framing/Structure Inspection
2 sheetrock missing on over barn back (typ) fire wall is not complete at front of
bldg @ girder trugs
3 1" in clearance need on B vent at lateral bracing in truses
Will be ok to insulate after electrical & plumbing & hvac inspector have passed
their inspections.
Inspector Comments:
06/23/2010PassPLL ADMINSidewalk Inspection
06/23/2010FailPLL ADMINSidewalk Inspection
200' disapproved to little fillInspector Comments:
06/23/2010PassTed DyeResidential Insulation Inspection
06/29/2010PassQuinton OwensResidential Sheetrock/Drywall Inspection
OK to tape drywallInspector Comments:
06/29/2010PassQuinton OwensResidential Sheetrock/Drywall Inspection
Drywall ok to tape
Staples?
Inspector Comments:
07/01/2010PassQuinton OwensResidential Sheetrock/Drywall Inspection
ok to tape drywallInspector Comments:
07/15/2010PassTed DyeSidewalk Inspection
6-8" base northside of bldg.Inspector Comments:
08/19/2010FailTed DyeResidential Building Final
Provide insulation certificate on elect panelInspector Comments:
08/23/2010N/ATed DyeResidential Building Final
OK 2453
2447 OK
2441 fan on main floor bath is not working
OK 2459
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 10-00097
Summerfield Townhomes - 4-plex
2459, 2453, 2447, 2441 W 960 S
New Single Family Residence
Permit Status of (Open) as of Report Date: 06/29/2020 8:57 am
Permit
Inspection
Summary
08/26/2010PassTed DyeResidential Building Final
Electrical
06/17/2010PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover in all 4 units
*Service approved to be energized for permanent power
Inspector Comments:
08/18/2010FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
-Closet light too close to shelving in master closet
- Wire to A/C unit exposed going into disconnect
- Wire exposed in under stair closet
Inspector Comments:
08/20/2010PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and CO in all units(4)Inspector Comments:
Mechanical
08/19/2010FailJohn BerryHVAC Final Inspection
Provide documentation on A/C secondary drain shut off switchInspector Comments:
08/23/2010PassJohn BerryHVAC Final Inspection
HVAC Final CompletedInspector Comments:
Plumbing
05/10/2010PassBrad JohnsonPlumbing Underground Inspection
approvedInspector Comments:
06/14/2010FailJohn BerryPlumbing Underground Inspection
Furnaces on 2nd floors where bldg damage could occur below must have a pan
under coils or a device to shut down furnace if secondary drain line has water in
it. - keep yellow tracer wire with gas line when burying
OK to bury gasline-follow above
No pressure test complete
Inspector Comments:
08/18/2010PassBrad JohnsonPlumbing Final Inspection
Approved for plumbing final!Inspector Comments:
Page 2 of 2