Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 10-00126 - Pro-Rental - New BuildingPermit Inspection Summary Permit Status of (Open) as of Report Date: 06/24/2020 8:37 am Permit Details Permit Number: 10-00126 Pro-Rental - New Building 174 & 176 E Moran View Road New Commercial Building Permit Issued Date: 06/10/2010 Permit Inspection Statistics 16Total Inspections Completed: 14Total Inspections Passed: Inspection Pass Rate: 87.50% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 07/28/2010PassJohn BerryFoundation Inspection Foundation walls look goodInspector Comments: 08/03/2010FailJohn BerryCommercial Framing/Structure Inspection CS - 16 Window Straps STHD 10 & 14 Shear - North wall sheating Reg's nailing 4"oc 8d staples are closer - entry trusses need clips to beam Inspector Comments: 09/01/2010PassJohn BerryCommercial Framing/Structure Inspection Framing completedInspector Comments: 09/16/2010PassJohn BerryCommercial Insulation Inspection Insulation looks goodInspector Comments: 09/20/2010PassJohn BerryResidential Sheetrock/Drywall Inspection Drywall looks good ok to coverInspector Comments: 10/14/2010PassJohn BerryCommercial Building Final Finish Restroom Final completed 10/19/10 D&Z must be completedInspector Comments: 10/15/2014PassQuinton OwensCommercial Building Final Toilet Paper Dispenser on order - Vert grab bar missing (check for backing) -Install on stud about 36-38" from back wall Toilet paper dispenser to far in front of toilet. Note: Vent reg. in horizontal position Inspector Comments: Electrical 07/14/2010PassBret StoddardCOM & MFR Electrical Service Inspection Need breaker blanks installed in open space.. Approved to be energized after these blanks are installed. Inspector Comments: 09/02/2010PassBret StoddardCommercial Electrical Rough-in Approved for coverInspector Comments: 10/15/2010FailBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Single receptacle required for water heater. Outlet loose outside bay(South) Drinking Fountain GFCI required(protection) Label main power panel pedestal Inspector Comments: 10/18/2010PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for final & COInspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 10-00126 Pro-Rental - New Building 174 & 176 E Moran View Road New Commercial Building Permit Status of (Open) as of Report Date: 06/24/2020 8:37 am Permit Inspection Summary Mechanical 09/07/2010PassJohn BerryHVAC Rough-in HVAC Rough Looks Good 60# test needs to be on a 100# gauge (test pressure is 2/3's of gauge pressure) *Pressure test on 100# gauge disapproved Inspector Comments: 09/09/2010PassJohn BerryHVAC Rough-in Gas line test good at 60#Inspector Comments: 10/14/2010PassJohn BerryHVAC Final Inspection HVAC Final CompletedInspector Comments: Plumbing 08/04/2010PassBrad JohnsonPlumbing Underground Inspection Approved for plumbingInspector Comments: 10/15/2010PassJoel GrayPlumbing Final Inspection plumbing Final ApprovedInspector Comments: Page 2 of 2