HomeMy WebLinkAboutINSPECTION SUMMARY - 10-00154 - Nauvoo House II Bldg #8Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 06/23/2020 1:14 pm
Permit Details Permit Number: 10-00154
Nauvoo House II Bldg #8
175 W 5th S
New Multi-Family Residence
Permit Issued Date: 05/06/2010
Permit Inspection Statistics
12Total Inspections Completed:
9Total Inspections Passed:
Inspection Pass Rate: 75.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building
07/02/2010PassJohn BerryCommercial Footing Inspection
Footing & Rebar looks goodInspector Comments:
07/08/2010PassJohn BerryFoundation Inspection
Foundation & Rebar look goodInspector Comments:
09/27/2010PassJohn BerryCommercial Framing/Structure Inspection
HVAC Rough & Framing bldg 8 looks goodInspector Comments:
10/01/2010PassPLL ADMINCommercial Insulation Inspection
Not Signed Notes: First layer sheet rock & insulationInspector Comments:
01/27/2011FailJohn BerryCommercial Building Final
- Install ADA grab bars at toilet - Install Shields on sink drains kitchen & Bath -
Have tub seat on hand ADA Install 2AIDBC Min Fire Ext Each Unit
Inspector Comments:
Electrical
09/28/2010PassBret StoddardCommercial Electrical Rough-in
Approved for cover on Bldg #8Inspector Comments:
10/18/2010PassBret StoddardCOM & MFR Electrical Service Inspection
Approved to be energized for permanent power.Inspector Comments:
01/20/2011FailBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection
-Mech rooms not complete - need sheet rock to cover romex & SER Cable.
-616 GFCI on bathroom receptacle not working properly - 416 peninsula
receptacle required and 12" or wide cabinet required receptacle -Fire alarm
system not ready
Inspector Comments:
01/26/2011PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection
Approved for a final & C.O.Inspector Comments:
Fire
01/28/2011N/APLL ADMINFire Alarm Rough-in
Not Signed - Notes:-Flow working ok. tamper switches working(5) - 416 only 1
bedroom (ada) has notification as per brad/Jon -Need 16' coverage heads -
literature OK - Extra heads are on site - clearance around riser OK, - No outside
water gong - pressure test(200psi/2hr) -heads need to be cleared throughout
*static psi 55 residual 45psi
Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 10-00154
Nauvoo House II Bldg #8
175 W 5th S
New Multi-Family Residence
Permit Status of (Open) as of Report Date: 06/23/2020 1:14 pm
Permit
Inspection
Summary
Mechanical
09/27/2010PassJohn BerryHVAC Rough-in
HVAC Rough & Framing bldg 8 looks goodInspector Comments:
Plumbing
09/28/2010PassBrad JohnsonPlumbing Rough-in
ApprovedInspector Comments:
Page 2 of 2