Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
plans_-_quad_lighting_installation_prk-03-20
P R O J E C T N O . P R K - 0 3 - 2 0 C I T Y O F R E X B U R G R E X B U R G PROJECTLOCATION B A S E B A L L Q U A D E L E C T R I C A L S c a l e P r o j e c t N a m e a n d A d d r e s s E X B U R G R P l o t S c a l e D a t e D e s c r i p t i o n S h e e t F i r m N a m e a n d A d d r e s s C I T Y O F A m e r i c a ' s F a m i l y C o m m u n i t y CITY O F R E X B U R G , I D A H O E S T A B L I S H E D I 8 8 3 C I T Y O F R E X B U R G B A S E B A L L Q U A D E L E C T R I C A L S H E E T I N D E X A N D V I C I N I T Y M A P S H E E T I N D E X 0 5 / 2 2 / 2 0 2 0 1 = 1 N O S C A L E 1 E D C M B R E T R M D S E S N E C IL T A T E O F I D A HOOT 1 4 6 8 5 PRO F E S S I O N A L E N G I N E E R T T H A L F S I Z E S H E E T I N D E X V I C I N I T Y M A P G E N E R A L L O C A T I O N S H E E T I N D E X A N D V I C I N I T Y M A P G E N E R A L N O T E S L I G H T I N G A N D F O U N D A T I O N P L A N V I E W E L E C T R I C A L P A N E L D E T A I L P O L E F O U N D A T I O N S ( P R O V I D E D B Y M U S C O ) M U S C O L I G H T I N G D E T A I L S 1 2 3 4 C - 1 , C - 2 7 - 1 5 E D C M B R E T R M D S E S N E C IL T A T E O F I D AHOOT 1 4 6 8 5 PRO F E S S I O N A L E N G I N E E R T T H A L F S I Z E S c a l e P r o j e c t N a m e a n d A d d r e s s E X B U R G R P l o t S c a l e D a t e D e s c r i p t i o n S h e e t F i r m N a m e a n d A d d r e s s C I T Y O F A m e r i c a ' s F a m i l y C o m m u n i t y CITY O F R E X B U R G , I D A H O E S T A B L I S H E D I 8 8 3 C I T Y O F R E X B U R G B A S E B A L L Q U A D E L E C T R I C A L G E N E R A L N O T E S G E N E R A L N O T E S 0 5 / 2 2 / 2 0 2 0 1 = 1 N O S C A L E 2 GENERAL NOTESGENERAL:1.UNLESS OTHERWISE SHOWN ON THESE PLANS, ALL WORK IS TO BE DONE IN ACCORDA N C E W I T H THE LATEST EDITION OF THE IDAHO STANDARDS FOR PUBLIC WORKS (I.S.P.W.C.) CONST R U C T I O N AND THE CITY OF REXBURG'S REVISIONS.2.ALL DISTANCES AND DATA SHALL BE CHECKED BY THE CONTRACTOR PRIOR TO THE ST A R T O F CONSTRUCTION. IN CASE OF CONFLICT, THE ENGINEER SHALL BE NOTIFIED IMMEDIAT E L Y S O THAT CLARIFICATION MAY BE MADE PRIOR TO THE START OF WORK.3.ELEVATIONS SHOWN ARE TO FINISHED SURFACE OR PIPE INVERT UNLESS OTHERWISE N O T E D . 4.THE CONTRACTOR SHALL RETAIN AND PROTECT OR REMOVE AND REPLACE ALL LAND S C A P I N G , TREES, UTILITIES, DITCHES, CULVERTS, FENCES, MAILBOXES, SIGNS, LIGHT POLES, HEAD G A T E S , A N D ALL OTHER MISCELLANEOUS ITEMS. ANY DAMAGE DONE BY THE CONTRACTOR SHALL B E REPAIRED AT CONTRACTOR'S EXPENSE.5.GENERAL LOCATIONS AND SIZES OF UTILITIES ARE SHOWN ON THE PLANS. THEY ARE T O B E U S E D FOR GENERAL INFORMATION ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR T O N O T I F Y THE APPROPRIATE UTILITY COMPANIES WHEN CONSTRUCTION MIGHT INTERFERE WIT H N O R M A L OPERATION OF ANY UTILITIES. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY T O H A V E THE APPROPRIATE UTILITY COMPANY FIELD-LOCATE ANY UTILITY INSTALLATIONS WH I C H M I G H T BE AFFECTED BY CONSTRUCTION PRIOR TO BEGINNING WORK IN THAT AREA. THE CON T R A C T O R SHALL BE RESPONSIBLE FOR MAINTAINING SERVICE OF EXISTING UTILITIES AND FOR RE S T O R I N G ANY UTILITIES DAMAGED DUE TO CONSTRUCTION AT NO ADDITIONAL COST TO THE O W N E R . 6.WHERE WORK IS PERFORMED ON EASEMENTS, THE CONTRACTOR SHALL TAKE EVERY P R E C A U T I O N TO ELIMINATE ANY ADVERSE EFFECTS ON THE ADJACENT PROPERTY.7.MINIMUM CLEARANCE BETWEEN NEW PIPELINES, EXISTING UTILITIES, AND STRUCTUR E S ( E X C E P T SEWERS) SHALL BE TWO FEET HORIZONTALLY.8.THERE ARE OTHER EXISTING FACILITIES WITHIN THE CONSTRUCTION CORRIDOR THAT A R E N O T SHOWN ON THE PLANS. THESE MAY INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWI N G : MAILBOXES, STREET SIGNS, ETC. CONTRACTOR SHALL RETAIN AND PROTECT WHEN PO S S I B L E A N D REPLACE IN KIND OTHERWISE. THIS WORK WILL BE INCIDENTAL TO OTHER BID ITEMS.9.THE PHOTO SHOWN ON THESE PLANS WAS TAKEN IN 2017 AND DOES NOT ACCURATEL Y REPRESENT CURRENT DEVELOPMENT.10.ALL CONTRACTORS WORKING WITHIN THE PROJECT BOUNDARIES ARE RESPONSIBLE F O R COMPLIANCE WITH ALL SAFETY LAWS OF ANY JURISDICTIONAL BODY. THE CONTRACT O R S H A L L BE RESPONSIBLE FOR ALL BARRICADES, SAFETY DEVICES, AND CONTROL OF TRAFFIC WI T H I N A N D AROUND THE CONSTRUCTION AREA.11.WORK SUBJECT TO APPROVAL BY ANY POLITICAL AGENCY MUST BE APPROVED PRIOR T O : BACKFILLING TRENCHES FOR PIPE, PLACING OF AGGREGATE BASE, PLACING OF CONCR E T E , A N D PLACING OF ASPHALT PAVING. WORK DONE WITHOUT SUCH APPROVAL DOES NOT REL I E V E T H E CONTRACTOR FROM THE RESPONSIBILITY OF PERFORMING THE WORK IN AN ACCEPTA B L E MANNER.12.THE CONTRACTOR SHALL KEEP ON SITE AT ALL TIMES A COPY OF THE APPROVED CONS T R U C T I O N PLANS ON WHICH IS RECORDED THE ACTUAL LOCATIONS OF THE CONSTRUCTED PIPEL I N E A N D ANY OTHER UTILITIES ENCOUNTERED. THE CONTRACTOR SHALL PROVIDE THESE LOCA T I O N S T O THE DESIGN ENGINEER FOR USE IN THE PRODUCTION OF RECORD DRAWINGS PRIOR TO F I N A L APPROVAL OF THE PIPELINE INSTALLATION.13.SURFACE REPAIR NOT CALLED OUT ON THE PLANS SHALL BE REPLACED IN KIND AND B E INCIDENTAL TO THE OTHER BID ITEMS.14.THE CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS DEPARTMENT TWO (2) WORKING D A Y S BEFORE INITIAL CONSTRUCTION BEGINS AND SHALL ALSO REQUEST INSPECTION OF W A T E R L I N E S AND APPURTENANCES TWENTY FOUR (24) HOURS IN ADVANCE OF BACKFILLING. E L E C T R I C A L : 1 . A L L P O W E R L I N E S A R E T O B E L O C A T E D A S S H O W N O N T H E P L A N S U N L E S S R E L O C A T E D I N T H E F I E L D B Y T H E E N G I N E E R T O A V O I D U N F O R E S E E N U T I L I T Y I N T E R F E R E N C E . W A T E R : 1 . I T W I L L B E T H E R E S P O N S I B I L I T Y O F T H E C O N T R A C T O R T O M A K E A R R A N G E M E N T S F O R W A T E R R E Q U I R E D F O R T E S T I N G , C O M P A C T I O N , A N D D U S T C O N T R O L M E A S U R E S . A W A T E R M E T E R W I L L B E P R O V I D E D B Y T H E C I T Y A T N O C H A R G E . S T R E E T S A N D T R A F F I C : 1 . T H E C O N T R A C T O R S H A L L P R O V I D E A L L T R A F F I C C O N T R O L M E A S U R E S I N A C C O R D A N C E W I T H T H E L A T E S T E D I T I O N O F T H E M A N U A L O N U N I F O R M T R A F F I C C O N T R O L D E V I C E S . M I S C E L L A N E O U S : 1 . S I T E C O N D I T I O N I S A F O R M E R L A N D F I L L . C O N T R A C T O R T O A C C O U N T F O R N A T I V E G R O U N D . N O A D D I T I O N A L C O S T W I L L B E A L L O W E D F O R M A T E R I A L . N O A D D I T I O N A L C H A N G E O R D E R T O B E G I V E N . 4868.96NG 4868.57NG 4869.51NG4870.33EO 4869.88EO 4870.35EO 4870.10EO 4869.80EO 4870.39EO4869.67EO S c a l e P r o j e c t N a m e a n d A d d r e s s E X B U R G R P l o t S c a l e D a t e D e s c r i p t i o n S h e e t F i r m N a m e a n d A d d r e s s C I T Y O F A m e r i c a ' s F a m i l y C o m m u n i t y CITY O F R E X B U R G , I D A H O E S T A B L I S H E D I 8 8 3 C I T Y O F R E X B U R G B A S E B A L L Q U A D E L E C T R I C A L L I G H T I N G P L A N V I E W O V E R A L L P L A N V I E W 0 6 / 0 5 / 2 0 2 0 1 = 2 1 " = 4 0 ' 3 EDCM BRETRM DS ESNECILTATEOFIDAHOOT14685PROFESSIONALENGINEERTTHALF SIZE T Y P I C A L L I G H T P O L E A N D F O U N D A T I O N L O C A T I O N . L I G H T P O L E S I Z E N O T T O S C A L E . EXISTING CONDUITNOT USED IN THISPROJECT STADIUM LIGHTINGCONTROL PANELLOCATIONA4 E X I S T I N G C O N D U I T S C H E D U L E Z 1 ( 9 8 0 F T ) Z 1 Z 4 Z 3 Z 2 (TYP) CONTRACTOR TOINSTALL APPROXIMATELY10-20' OF NEW CONDUITFROM EXISTING JUNCTIONBOX TO LIGHT POLEFOUNDATIONEXISTING CONDUIT NOT USED IN THIS PROJEC T L A B E L C O N D U I T S I Z E 2 " W I R E S C H E D U L E L I G H T P O L E C 1 C 2 C 3 C 4 A 2 B 2 A 3 B 3 A 1 B 1 A 4 B 4 C 5 C 6 C 7 C 8 C 1 C 2 C 3 B 1 A 1 A4B4 A 3 B 3 A 2 B 2 C 4 C5 C6 C7 C8 ( 4 ) # 6 ( 4 ) # 6 ( 2 ) # 6 ( 2 ) # 6 ( 8 ) # 6 ( 4 ) # 6 ( 4 ) # 6 ( 4 ) # 6 ( 8 ) # 6 ( 8 ) # 6 ( 4 ) # 6 ( 4 ) # 6 ( 2 ) # 6 ( 2 ) # 6 ( 4 ) # 6 ( 4 ) # 6 ( 1 ) # 8 E Q U I P M E N T G R O U N D ( 1 ) # 8 E Q U I P M E N T G R O U N D ( 1 ) # 8 E Q U I P M E N T G R O U N D ( 1 ) # 8 E Q U I P M E N T G R O U N D W I R E S G R O U N D Z 2 ( 7 6 0 F T ) 2 " Z 3 ( 4 5 5 F T ) 2 " Z 4 ( 9 2 5 F T ) 2 " N O T E S : 1 . C O N T R A C T O R T O I N S T A L L L I G H T P O L E S A T L O C A T I O N S S H O W N . 2 . C O N T R A C T O R T O A D J U S T L O C A T I O N S O F I R R I G A T I O N L I N E S , C O N T R O L V A L V E S A N D B O X E S A S R E Q U I R E D T O A L L O W P O L E S T O B E I N S T A L L E D I N C O R R E C T L O C A T I O N S . 3 . C O N T R A C T O R T O R E P A I R A L L S O D A N D I R R I G A T I O N S Y S T E M T O P R E - C O N S T R U C T I O N C O N D I T I O N S . 4 . C O N T R A C T O R T O I N S T A L L L I G H T P O L E S A N D F O U N D A T I O N S A S P E R S U P P L I E R S S T R U C T U R A L D E S I G N . 5 . A L L E L E C T R I C A L I N S T A L L A T I O N S H A L L C O M P L Y W I T H R E Q U I R E M E N T S D E S C R I B E D I N S P E C I A L P R O V I S I O N S . 6 . I N S T A L L W I R E S I N S H A R E D C O N D U I T S W I T H H O M E R U N T O C O N T R O L P A N E L F R O M E A C H L I G H T P O L E . G R O U N D S H A R E D W I R E . 7 . A L L W I R E T O B E O F T H E T H W N T Y P E . S c a l e P r o j e c t N a m e a n d A d d r e s s E X B U R G R P l o t S c a l e D a t e D e s c r i p t i o n S h e e t F i r m N a m e a n d A d d r e s s C I T Y O F A m e r i c a ' s F a m i l y C o m m u n i t y CITY O F R E X B U R G , I D A H O E S T A B L I S H E D I 8 8 3 C I T Y O F R E X B U R G B A S E B A L L Q U A D E L E C T R I C A L E L E C T R I C A L P A N E L D E T A I L S D E T A I L S 0 6 / 0 5 / 2 0 2 0 1 = 2 A S N O T E D 4 E D C M B R E T R M D S E S N E C IL T A T E O F I D AHOOT 1 4 6 8 5 PRO F E S S I O N A L E N G I N E E R T T H A L F S I Z E N O T T O S C A L E A 4 E L E C T R I C A L P A N E L D E T A I L PROJECT SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Zach Morris • File #198219D • 08-Jan-20 Rexburg Quad Rexburg, ID LighƟng System Pole / Fixture Summary Pole ID Pole Height Mtg Height Fixture Qty Luminaire Type Load Circuit A1 70'70'2 TLC-LED-1200 2.34 kW A 70'2 TLC-LED-1200 2.34 kW D 70'1 TLC-LED-900 0.89 kW A 70'1 TLC-LED-900 0.89 kW D A2 70'70'2 TLC-LED-1200 2.34 kW B 70'2 TLC-LED-1200 2.34 kW A 70'1 TLC-LED-900 0.89 kW B 70'1 TLC-LED-900 0.89 kW A A3 70'70'2 TLC-LED-1200 2.34 kW C 70'2 TLC-LED-1200 2.34 kW B 70'1 TLC-LED-900 0.89 kW C 70'1 TLC-LED-900 0.89 kW B A4 70'70'2 TLC-LED-1200 2.34 kW D 70'2 TLC-LED-1200 2.34 kW C 70'1 TLC-LED-900 0.89 kW D 70'1 TLC-LED-900 0.89 kW C B1 80'80'4 TLC-LED-1500 5.72 kW A 80'4 TLC-LED-1500 5.72 kW D 18'1 TLC-BT-575 0.58 kW A B2 80'80'4 TLC-LED-1500 5.72 kW B 80'4 TLC-LED-1500 5.72 kW A 18'1 TLC-BT-575 0.58 kW A 18'1 TLC-BT-575 0.58 kW B B3 80'80'4 TLC-LED-1500 5.72 kW C 80'4 TLC-LED-1500 5.72 kW B 18'1 TLC-BT-575 0.58 kW C 18'1 TLC-BT-575 0.58 kW B B4 80'80'4 TLC-LED-1500 5.72 kW D 80'4 TLC-LED-1500 5.72 kW C 18'1 TLC-BT-575 0.58 kW C C1-C2 70'70'3 TLC-LED-1200 3.51 kW A 16'2 TLC-BT-575 1.15 kW A C3-C4 70'70'3 TLC-LED-1200 3.51 kW B 16'2 TLC-BT-575 1.15 kW B C5-C6 70'70'3 TLC-LED-1200 3.51 kW C 16'2 TLC-BT-575 1.15 kW C C7-C8 70'70'3 TLC-LED-1200 3.51 kW D 16 98 110.03 kW Circuit Summary Circuit Description Load Fixture Qty A Baseball 1 28.37 kW 26 B Baseball 2 28.37 kW 26 C Baseball 3 28.37 kW 26 D Baseball 4 24.92 kW 20 Fixture Type Summary Type Source Wattage Lumens L90 L80 L70 Quantity TLC-LED-1200 LED 5700K - 75 CRI 1170W 136,000 >81,000 >81,000 >81,000 40 TLC-LED-900 LED 5700K - 75 CRI 890W 89,600 >81,000 >81,000 >81,000 8 TLC-BT-575 LED 5700K - 75 CRI 575W 52,000 >81,000 >81,000 >81,000 18 TLC-LED-1500 LED 5700K - 75 CRI 1430W 160,000 >81,000 >81,000 >81,000 32 PROJECT SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Zach Morris • File #198219D • 08-Jan-20 Rexburg Quad Rexburg, ID Light Level Summary Calculation Grid Summary IlluminationGrid Name Calculation Metric Ave Min Max Max/Min Ave/Min Circuits Fixture Qty 150' Spill Line Horizontal Illuminance 0.04 0 0.08 53.94 A,B,C,D 98 150' Spill Line Max Vertical Illuminance Metric 0.14 0.01 0.34 55.54 13.98 A,B,C,D 98 Baseball 1 (Infield)Horizontal Illuminance 36.7 24 45 1.88 1.53 A 26 Baseball 1 (Outfield)Horizontal Illuminance 20.6 14 27 1.94 1.47 A 26 Baseball 2 (Infield)Horizontal Illuminance 32.7 21 42 1.96 1.56 B 26 Baseball 2 (Outfield)Horizontal Illuminance 20.4 14 26 1.88 1.46 B 26 Baseball 3 (Infield)Horizontal Illuminance 35 23 45 2.00 1.52 C 26 Baseball 3 (Outfield)Horizontal Illuminance 20.8 14 31 2.29 1.48 C 26 Baseball 4 (Infield)Horizontal Illuminance 37 27 48 1.76 1.37 D 20 Baseball 4 (Outfield)Horizontal Illuminance 22.3 14 32 2.22 1.59 D 20 ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Zach Morris • File #198219D • 08-Jan-20 C1 C2 41 41 36 39 32 23 21 21 18 42 45 37 45 31 24 22 21 22 23 15 37 40 43 40 30 22 19 18 18 23 21 39 45 40 33 27 21 19 18 17 17 21 36 35 32 28 24 20 21 23 24 23 14 26 27 26 25 23 19 18 20 21 22 16 26 25 24 25 19 16 18 21 16 16 21 19 21 25 21 18 24 19 15 24 20 16 23 20 20 18 25 27 19 22 21 15 16 24 22 14 A1 B1 50 ' 53' 10 9 ' 300' 30 0 ' 109' 33 ' 173' 39 ' 50' 17 2 ' 59' B2A2 SCALE IN FEET 1 : 80 0'80'160' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADEELEVATION MOUNTINGHEIGHT LUMINAIRETYPE QTY /POLE THISGRID OTHERGRIDS1A170'-70' 70' TLC-LED-900 TLC-LED-1200 1/1* 2/2* 1 2 1 2 1 A2 70'-70' 70' TLC-LED-900 TLC-LED-1200 1/1* 2/2* 1 2 1 2 1 B1 80'-18'80'TLC-BT-575TLC-LED-1500 14/4*14 04 1 B2 80'-18'80'TLC-BT-575TLC-LED-1500 1/1*4/4*14 14 2 C1-C2 70'-15.5' 70' TLC-BT-575 TLC-LED-1200 2 3 2 3 0 06TOTALS412615 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Rexburg Quad Rexburg, ID GRID SUMMARY Name: Baseball 1 Size: Irregular 300' / 315' / 300' Spacing: 30.0' x 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES InĮeld Ouƞield Guaranteed Average:30 20 Scan Average:36.70 20.61 Maximum:45 27 Minimum:24 14 Avg / Min:1.52 1.49 Guaranteed Max / Min:2.5 3 Max / Min:1.88 1.94 UG (adjacent pts):1.45 1.64 CU:0.74 No. of Points:25 75 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 136,000 / 89,600 / 52,000 / 160,000 lumens No. of Luminaires: 26 Total Load: 28.37 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-1200 >81,000 >81,000 >81,000 TLC-LED-900 >81,000 >81,000 >81,000 TLC-BT-575 >81,000 >81,000 >81,000 TLC-LED-1500 >81,000 >81,000 >81,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the"Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Zach Morris • File #198219D • 08-Jan-20 C3 C4 39 40 33 36 34 26 24 24 22 39 42 36 35 28 23 24 23 25 26 16 36 36 37 32 24 21 21 20 20 25 22 38 39 33 26 23 20 21 22 19 18 20 33 28 26 23 21 20 22 24 25 23 14 23 23 20 20 20 18 17 19 20 22 21 22 20 20 22 18 15 18 21 16 19 18 16 19 23 19 18 24 19 20 21 15 16 23 19 21 18 24 23 16 22 21 15 16 22 20 14 173' 5 9 ' 300' 1 0 9 ' 50' 5 3 ' 109' 3 0 0 ' 53' 5 0 ' 59' 1 7 3 ' B2A2 A3 B3 SCALE IN FEET 1 : 80 0'80'160' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADEELEVATION MOUNTINGHEIGHT LUMINAIRETYPE QTY /POLE THISGRID OTHERGRIDS1A270'-70' 70' TLC-LED-900 TLC-LED-1200 1/1* 2/2* 1 2 1 2 1 A3 70'-70' 70' TLC-LED-900 TLC-LED-1200 1/1* 2/2* 1 2 1 2 1 B2 80'-18'80'TLC-BT-575TLC-LED-1500 1/1*4/4*14 14 1 B3 80'-18'80'TLC-BT-575TLC-LED-1500 1/1*4/4*14 14 2 C3-C4 70'-15.5' 70' TLC-BT-575 TLC-LED-1200 2 3 2 3 0 06TOTALS422616 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Rexburg Quad Rexburg, ID GRID SUMMARY Name: Baseball 2 Size: Irregular 300' / 315' / 300' Spacing: 30.0' x 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES InĮeld Ouƞield Guaranteed Average:30 20 Scan Average:32.71 20.43 Maximum:42 26 Minimum:21 14 Avg / Min:1.53 1.46 Guaranteed Max / Min:2.5 3 Max / Min:1.96 1.88 UG (adjacent pts):1.38 1.65 CU:0.70 No. of Points:25 75 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 136,000 / 89,600 / 52,000 / 160,000 lumens No. of Luminaires: 26 Total Load: 28.37 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-1200 >81,000 >81,000 >81,000 TLC-LED-900 >81,000 >81,000 >81,000 TLC-BT-575 >81,000 >81,000 >81,000 TLC-LED-1500 >81,000 >81,000 >81,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the"Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Zach Morris • File #198219D • 08-Jan-20 C5 C6 36 38 30 30 30 26 17 17 17 38 45 38 41 38 29 23 23 25 24 15 30 36 45 45 33 24 20 21 24 27 18 30 38 41 34 27 21 18 19 21 24 17 32 35 33 26 23 20 19 21 19 19 18 31 27 22 20 20 19 19 22 24 22 14 25 23 19 19 20 18 16 18 21 22 23 24 20 19 23 20 18 23 23 15 18 24 21 19 24 21 20 25 17 24 25 19 23 20 21 16 15 22 23 15 15 2 9 7 ' 152' 1 1 0 ' 302' 5 3 ' 50' 5 0 ' 39' 1 7 3 ' 33' 5 9 ' 172' A3 B3 A4B4 SCALE IN FEET 1 : 80 0'80'160' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADEELEVATION MOUNTINGHEIGHT LUMINAIRETYPE QTY /POLE THISGRID OTHERGRIDS1A370'-70' 70' TLC-LED-900 TLC-LED-1200 1/1* 2/2* 1 2 1 2 1 A4 70'-70' 70' TLC-LED-900 TLC-LED-1200 1/1* 2/2* 1 2 1 2 1 B3 80'-18'80'TLC-BT-575TLC-LED-1500 1/1*4/4*14 14 1 B4 80'-18'80'TLC-BT-575TLC-LED-1500 14/4*14 04 2 C5-C6 70'-15.5' 70' TLC-BT-575 TLC-LED-1200 2 3 2 3 0 06TOTALS412615 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Rexburg Quad Rexburg, ID GRID SUMMARY Name: Baseball 3 Size: Irregular 300' / 329' / 300' Spacing: 30.0' x 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES InĮeld Ouƞield Guaranteed Average:30 20 Scan Average:34.96 20.75 Maximum:45 31 Minimum:23 14 Avg / Min:1.54 1.52 Guaranteed Max / Min:2.5 3 Max / Min:2.00 2.29 UG (adjacent pts):1.37 1.61 CU:0.76 No. of Points:25 80 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 136,000 / 89,600 / 52,000 / 160,000 lumens No. of Luminaires: 26 Total Load: 28.37 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-1200 >81,000 >81,000 >81,000 TLC-LED-900 >81,000 >81,000 >81,000 TLC-BT-575 >81,000 >81,000 >81,000 TLC-LED-1500 >81,000 >81,000 >81,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the"Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Zach Morris • File #198219D • 08-Jan-20 C7 C8 394133373325151719 4348354135262123252919 3337374035251720222821 3942413631221517182117 38373533272017222015 32313029231818242618 202828272317182222 172223272520212114 1829222927222015 3230302616 222418 39' 5 0 ' 64' 2 9 6 ' 279' 1 2 2 ' 50' 3 9 ' 173' 3 3 ' 33' 1 7 2 ' A4B4 A1 B1 SCALE IN FEET 1 : 80 0'80'160' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADEELEVATION MOUNTINGHEIGHT LUMINAIRETYPE QTY /POLE THISGRID OTHERGRIDS1A170'-70' 70' TLC-LED-900 TLC-LED-1200 1/1* 2/2* 1 2 1 2 1 A4 70'-70' 70' TLC-LED-900 TLC-LED-1200 1/1* 2/2* 1 2 1 2 1 B1 80'-18'80'TLC-BT-575TLC-LED-1500 14/4*04 14 1 B4 80'-18'80'TLC-BT-575TLC-LED-1500 14/4*04 14 2 C7-C8 70'-70'TLC-LED-1200 3 3 0 6 TOTALS 36 20 16 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Rexburg Quad Rexburg, ID GRID SUMMARY Name: Baseball 4 Size: 300'/300'/300' - basepath 90' Spacing: 30.0' x 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES InĮeld Ouƞield Guaranteed Average:30 20 Scan Average:36.99 22.27 Maximum:48 32 Minimum:27 14 Avg / Min:1.37 1.54 Guaranteed Max / Min:2.5 3 Max / Min:1.76 2.22 UG (adjacent pts):1.36 1.65 CU:0.83 No. of Points:25 71 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 136,000 / 89,600 / 160,000 lumens No. of Luminaires: 20 Total Load: 24.92 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-1200 >81,000 >81,000 >81,000 TLC-LED-900 >81,000 >81,000 >81,000 TLC-LED-1500 >81,000 >81,000 >81,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the"Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Zach Morris • File #198219D • 08-Jan-20 C1 C2 A1 B1 C3 C4 B2A2 C5 C6 A3 B3 C7 C8 0.02 0.02 0.02 0.03 0.03 0.02 0.03 0.03 0.04 0.05 0.04 0.05 0.04 0.06 0.08 0.05 0.07 0.06 0.05 0.04 0.02 0.01 0.00 0.00 0.00 0.00 0.02 0.02 0.02 0.03 0.03 0.04 0.04 0.03 0.02 0.03 0.03 0.04 0.06 0.07 0.08 0.08 0.08 0.07 0.08 0.06 0.05 0.05 0.060.070.080.060.070.060.040.030.020.020.020.010.010.000.000.000.010.01 0.01 0.01 0.02 0.03 0.03 0.04 0.07 0.08 0.08 0.08 0.08 0.07 0.07 0.06 0.04 0.03 0.03 0.03 0.03 0.04 0.03 0.02 0.02 0.01 0.00 0.00 0.00 0.01 0.03 0.04 0.06 0.07 0.04 0.04 0.06 0.06 0.04 0.03 0.04 0.04 0.04 0.05 0.03 A4B4 SCALE IN FEET 1 : 150 0'150'300' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADEELEVATION MOUNTINGHEIGHT LUMINAIRETYPE QTY /POLE THISGRID OTHERGRIDS4A1-A4 70'-70' 70' TLC-LED-900 TLC-LED-1200 1/1* 2/2* 2 4 0 0 1 B1 80'-18' 80' TLC-BT-575 TLC-LED-1500 1 4/4* 1 8 0 0 2 B2-B3 80'-18'80'TLC-BT-575TLC-LED-1500 1/1*4/4*28 00 1 B4 80'-18'80'TLC-BT-575TLC-LED-1500 14/4*18 00 4 C1-C2 C5-C6 70'-70' 15.5' TLC-LED-1200 TLC-BT-575 3 2 3 2 0 02C3-C4 70'-15.5' 70' TLC-BT-575 TLC-LED-1200 2 3 2 3 0 02C7-C8 70'-70'TLC-LED-1200 3 3 0 16 TOTALS 98 98 0 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Rexburg Quad Rexburg, ID GRID SUMMARY Name: 150' Spill Line Spacing: 30.0' Height: 0.0' above grade ILLUMINATION SUMMARY HORIZONTAL FOOTCANDLES EnƟre Grid Scan Average:0.0383 Maximum:0.08 Minimum:0.00 No. of Points:109 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 136,000 / 89,600 / 52,000 / 160,000 lumens No. of Luminaires: 98 Total Load: 110.03 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-1200 >81,000 >81,000 >81,000 TLC-LED-900 >81,000 >81,000 >81,000 TLC-BT-575 >81,000 >81,000 >81,000 TLC-LED-1500 >81,000 >81,000 >81,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements:Individual Įeld measurements may vary fromcomputer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to AmperageDraw Chart and/or the"Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Zach Morris • File #198219D • 08-Jan-20 C1 C2 A1 B1 C3 C4 B2A2 C5 C6 A3 B3 C7 C8 0.06 0.06 0.07 0.08 0.09 0.09 0.11 0.15 0.19 0.21 0.18 0.17 0.13 0.19 0.26 0.19 0.24 0.20 0.16 0.11 0.05 0.04 0.02 0.01 0.01 0.02 0.05 0.06 0.07 0.09 0.11 0.13 0.15 0.15 0.10 0.16 0.15 0.22 0.28 0.31 0.31 0.32 0.31 0.28 0.28 0.20 0.18 0.19 0.270.330.340.250.270.220.150.110.080.060.050.050.030.020.020.020.040.05 0.06 0.06 0.07 0.09 0.10 0.12 0.19 0.27 0.30 0.34 0.34 0.33 0.30 0.24 0.17 0.13 0.10 0.09 0.08 0.12 0.09 0.07 0.06 0.03 0.01 0.01 0.01 0.03 0.07 0.10 0.14 0.20 0.10 0.10 0.16 0.15 0.11 0.08 0.13 0.16 0.17 0.17 0.12 A4B4 SCALE IN FEET 1 : 150 0'150'300' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADEELEVATION MOUNTINGHEIGHT LUMINAIRETYPE QTY /POLE THISGRID OTHERGRIDS4A1-A4 70'-70' 70' TLC-LED-900 TLC-LED-1200 1/1* 2/2* 2 4 0 0 1 B1 80'-18' 80' TLC-BT-575 TLC-LED-1500 1 4/4* 1 8 0 0 2 B2-B3 80'-18'80'TLC-BT-575TLC-LED-1500 1/1*4/4*28 00 1 B4 80'-18'80'TLC-BT-575TLC-LED-1500 14/4*18 00 4 C1-C2 C5-C6 70'-70' 15.5' TLC-LED-1200 TLC-BT-575 3 2 3 2 0 02C3-C4 70'-15.5' 70' TLC-BT-575 TLC-LED-1200 2 3 2 3 0 02C7-C8 70'-70'TLC-LED-1200 3 3 0 16 TOTALS 98 98 0 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Rexburg Quad Rexburg, ID GRID SUMMARY Name: 150' Spill Line Spacing: 30.0' Height: 0.0' above grade ILLUMINATION SUMMARY MAX VERTICAL FOOTCANDLES EnƟre Grid Scan Average:0.1398 Maximum:0.34 Minimum:0.01 No. of Points:109 LUMINAIRE INFORMATION Color / CRI: 5700K - 75 CRI Luminaire Output: 136,000 / 89,600 / 52,000 / 160,000 lumens No. of Luminaires: 98 Total Load: 110.03 kW Lumen Maintenance Luminaire Type L90 hrs L80 hrs L70 hrs TLC-LED-1200 >81,000 >81,000 >81,000 TLC-LED-900 >81,000 >81,000 >81,000 TLC-BT-575 >81,000 >81,000 >81,000 TLC-LED-1500 >81,000 >81,000 >81,000 Reported per TM-21-11. See luminaire datasheet for details. Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements:Individual Įeld measurements may vary fromcomputer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to AmperageDraw Chart and/or the"Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. EQUIPMENT LAYOUT Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2020 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: Zach Morris • File #198219D • 08-Jan-20 Baseball 1 Irregular C1 C2 50 ' 53' 10 9 ' 300' 30 0 ' 109' 33 ' 173' 39 ' 50' 17 2 ' 59' A1 B1 C3 C4 Baseball 2 Irregular 173' 5 9 ' 300' 1 0 9 ' 50' 5 3 ' 109' 3 0 0 ' 53' 5 0 ' 59' 1 7 3 ' B2A2 C5 C6 Baseball 3 Irregular 2 9 7 ' 152' 1 1 0 ' 302' 5 3 ' 50' 5 0 ' 39' 1 7 3 ' 33' 5 9 ' 172' A3 B3 C7 C8 Baseball 4 300'/300'/300' - basepath 90' 39' 5 0 ' 392' 1 0 9 ' 201' 3 0 0 ' 64' 2 9 6 ' 265' 3 3 ' 392' 2 0 1 ' 142' 3 9 ' 201' 3 9 2 ' 279' 1 2 2 ' 152' 3 8 9 ' 302' 2 0 2 ' 50' 3 9 ' 39' 1 4 2 ' 33' 2 6 5 ' 173' 3 3 ' 33' 1 7 2 ' A4B4 SCALE IN FEET 1 : 80 0'80'160' Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Rexburg Quad Rexburg, ID EQUIPMENT LAYOUT INCLUDES: · Baseball 1 · Baseball 2 · Baseball 3 · Baseball 4 Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. SINGLE LUMINAIRE AMPERAGE DRAW CHARTBallast SpeciĮcaƟons (.90 min power factor) Line Amperage Per Luminaire (max draw) Single Phase Voltage 208 (60) 220 (60) 240 (60) 277 (60) 347 (60) 380 (60) 480 (60) TLC-LED-1200 7.0 6.6 6.1 5.2 4.2 4.0 3.0 TLC-LED-900 5.3 5.0 4.6 4.0 3.2 2.9 2.3 TLC-BT-575 3.4 3.2 2.9 2.5 2.0 1.8 1.5 TLC-LED-1500 8.5 8.1 7.4 6.4 5.1 4.7 3.7