Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 10-00254 - Northgate Apts Bldg #2 - 201-210Permit Inspection Summary Permit Status of (Open) as of Report Date: 06/16/2020 8:57 am Permit Details Permit Number: 10-00254 Northgate Apts Bldg #2 - 201-210 350 W 6th S New Multi-Family Residence Permit Issued Date: Permit Inspection Statistics 23Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 73.91% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 07/16/2010PassJohn BerryFoundation Inspection foundation and rebar look goodInspector Comments: 07/19/2010PassJohn BerryFoundation Inspection foundation walls and rebar look goodInspector Comments: 07/29/2010PassJohn BerryCommercial Footing Inspection Int. Bearing Footings Look GoodInspector Comments: 08/19/2010N/AJohn BerryCommercial Framing/Structure Inspection HVAC, Elec, Plumb Not Completed Also See Report for #5 Inspector Comments: 08/24/2010FailJohn BerryCommercial Framing/Structure Inspection HD5's Missing Not Ready M,E,D & Sprink. Inspector Comments: 08/26/2010PassJohn BerryCommercial Framing/Structure Inspection Framing OK to coverInspector Comments: 08/30/2010PassJohn BerryCommercial Insulation Inspection Insulation Northside OK to coverInspector Comments: 08/31/2010PassTed DyeCommercial Insulation Inspection 202 - 210 OK to Rock Also inspected 506 for Rock OK Inspector Comments: 09/01/2010PassQuinton OwensCommercial Sheetrock/Drywall Inspection Completed 9-3 OK to tape all North Units Inspector Comments: 09/01/2010FailJohn BerryCommercial Sheetrock/Drywall Inspection Not ReadyInspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 10-00254 Northgate Apts Bldg #2 - 201-210 350 W 6th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 06/16/2020 8:57 am Permit Inspection Summary 09/07/2010PassQuinton OwensCommercial Sheetrock/Drywall Inspection Northside Done 9-4 Southside Units Complete Ok to tape Inspector Comments: 09/11/2010PassQuinton OwensCommercial Sheetrock/Drywall Inspection Completed 9/11Inspector Comments: 11/02/2010FailQuinton OwensCommercial Building Final Firecaulk around water shutoff valvee in firewall. Mech. Final OK Inspector Comments: 11/02/2010FailQuinton OwensCommercial Building Final Firecaulk around water shutoff valvee in firewall. Mech. Final OK Inspector Comments: 11/04/2010PassQuinton OwensCommercial Building Final Final approved except for firestop rings under both vanities.Inspector Comments: Electrical 08/24/2010PassBret StoddardCommercial Electrical Rough-in Approved for cover on North Side (even #'s) *Service approved to be energized for permanent power. Inspector Comments: 08/30/2010FailBret StoddardCommercial Electrical Rough-in 208- Wire missing for light on up bed. nail plates SER 206- Nail plate SER. 210 Nail plate SER. Wires pulled out of walls on every unit upstairs. -Weds. PM Re-inspect Inspector Comments: 08/31/2010PassBret StoddardCommercial Electrical Rough-in Approved for cover in southsideInspector Comments: 10/29/2010PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final & CO except doghouse (#2)Inspector Comments: 12/03/2010PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for final - DoghouseInspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 10-00254 Northgate Apts Bldg #2 - 201-210 350 W 6th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 06/16/2020 8:57 am Permit Inspection Summary Mechanical 08/26/2010PassJohn BerryHVAC Rough-in HVAC Rough Looks Good Except - 2 west units on south side. Pressure test good 60# Inspector Comments: 08/30/2010PassJohn BerryHVAC Rough-in HVAC rough looks good Gasline 60# Inspector Comments: Plumbing 07/27/2010PassBrad JohnsonPlumbing Underground Inspection approved for cover!!Inspector Comments: Page 3 of 3