Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 10-00255 - Northgate Apts Bldg #3 - Units 301-308Permit Inspection Summary Permit Status of (Open) as of Report Date: 06/16/2020 8:56 am Permit Details Permit Number: 10-00255 Northgate Apts Bldg #3 - Units 301-308 350 W 6th S New Multi-Family Residence Permit Issued Date: Permit Inspection Statistics 17Total Inspections Completed: 14Total Inspections Passed: Inspection Pass Rate: 82.35% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 07/15/2010PassTed DyeCommercial Footing Inspection 07/22/2010PassQuinton OwensCommercial Footing Inspection OK to pourInspector Comments: 08/05/2010PassJohn BerryCommercial Footing Inspection Interior Footings Look GoodInspector Comments: 09/07/2010FailQuinton OwensCommercial Framing/Structure Inspection Dryer vent separated above outside storage room. (2nd unit from west end) Furred out wall on main floor behind tub not completely sealed off. Separate attic spaces above storage room. OK to insulate. Inspector Comments: 09/09/2010FailQuinton OwensCommercial Insulation Inspection Insulation rulers not installed for attic insulation Soffit vents blocked Some units ony have 1 soffit vent (2 min required) Inspector Comments: 09/10/2010PassQuinton OwensCommercial Insulation Inspection Insulation OK to cover. All units. *Patch holes in draft stop. OK. Inspector Comments: 09/10/2010PassQuinton OwensCommercial Framing/Structure Inspection 2 West units, main floor, furred out wall behind tub. -small joist cavity at top not closed off. (OK 9/13) OK to insulate South units completed. Inspector Comments: 09/14/2010PassQuinton OwensCommercial Sheetrock/Drywall Inspection North Units Complete 9/16Inspector Comments: 09/15/2010PassQuinton OwensCommercial Sheetrock/Drywall Inspection Completed 9/20Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 10-00255 Northgate Apts Bldg #3 - Units 301-308 350 W 6th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 06/16/2020 8:56 am Permit Inspection Summary 11/03/2010FailQuinton OwensCommercial Building Final 302 Patch Ceiling at fire sprinkler (north side upstairs bth) 301 Patch Ceiling at bath fan (north side upstairs bth) 305 Smoke detector interconnection problem (north side 2nd unit from west end) sidewalks not finished Firecaulk not used at water lines at water heater 302 Gas leak in mech room south east end unit Firecaulking at drain lines penetrating fire barrier Inspector Comments: Electrical 09/07/2010PassBret StoddardCommercial Electrical Rough-in Approved for cover on South side.Inspector Comments: 09/08/2010PassBret StoddardCommercial Electrical Rough-in Approved for cover - doghouse & north side *Service Approved to be energized. Inspector Comments: 11/05/2010PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final & C.O. Except doghouseInspector Comments: 12/03/2010PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final doghouseInspector Comments: Mechanical 09/03/2010PassQuinton OwensHVAC Rough-in Mech. rough-in OKInspector Comments: Plumbing 08/03/2010PassBrad JohnsonPlumbing Underground Inspection Approved for cover.Inspector Comments: 10/26/2010PassBrad JohnsonPlumbing Final Inspection Approved for plumbing final!Inspector Comments: Page 2 of 2