HomeMy WebLinkAboutINSPECTION SUMMARY - 10-00257 - Northgate Apts Bldg #5 - 501-508Permit Inspection Summary Permit Status of (Open) as of Report Date: 06/16/2020 8:53 am Permit Details Permit Number: 10-00257 Northgate Apts Bldg #5 - 501-508 350 W 6th S New Multi-Family Residence Permit Issued Date: Permit Inspection Statistics 20Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 75.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 07/12/2010PassJohn BerryCommercial Footing Inspection Footing & rebar look goodInspector Comments: 07/14/2010PassTed DyeFoundation Inspection 2 horizontal barsInspector Comments: 07/23/2010PassJohn BerryCommercial Footing Inspection Floor & pier footings look goodInspector Comments: 08/16/2010PassJohn BerryCommercial Insulation Inspection Insulation looks goodInspector Comments: 08/16/2010PassJohn BerryCommercial Sheetrock/Drywall Inspection Insulation looks goodInspector Comments: 08/19/2010FailJohn BerryCommercial Framing/Structure Inspection -Drywall missing stud backing need dryer vent - as per architect's letter blocking req'd in staggered sep. wall - gables & overhang sheeting req's nailing - fire caulk penetrations in chase between units - anchor bolts req'd bearing walls - upperantry straps missing Inspector Comments: 08/24/2010FailJohn BerryCommercial Framing/Structure Inspection Re-Install missing studs in staggered wall both floors Insulation west side looks good Inspector Comments: 08/24/2010FailJohn BerryCommercial Framing/Structure Inspection -HD5's missing - Anchor bolts in bearing walls missing - Gable areas not nailed per plans Inspector Comments: 08/26/2010PassJohn BerryCommercial Sheetrock/Drywall Inspection Drywall looks goodInspector Comments: 10/26/2010FailQuinton OwensCommercial Building Final Stair handrail in south west unit too low. Finish firecaulking in mech roomsInspector Comments: 10/28/2010PassQuinton OwensCommercial Building Final bldg Final OKInspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 10-00257 Northgate Apts Bldg #5 - 501-508 350 W 6th S New Multi-Family Residence Permit Status of (Open) as of Report Date: 06/16/2020 8:53 am Permit Inspection Summary Electrical 08/23/2010PassBret StoddardCommercial Electrical Rough-in Approved for cover in building #5Inspector Comments: 08/23/2010PassBret StoddardCOM & MFR Electrical Service Inspection *Service(x2)Approved to be energized for perm powerInspector Comments: 10/22/2010PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final & CO 8 units - Not Doghouse - Not doneInspector Comments: 12/03/2010PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final - doghouseInspector Comments: Fire 08/23/2010PassBrad JohnsonFire Sprinkler Final Inspection Sprinkler piping tested @200 psi for 2 hrs approved for coverInspector Comments: Mechanical 08/20/2010PassJohn BerryHVAC Rough-in 65# 10am -seal 12" return joints inw - Fire caulk upstairs bath exh fans at box outlet Inspector Comments: 10/26/2010FailQuinton OwensHVAC Final Inspection Sensor broken off at bottom of furnacesInspector Comments: 10/28/2010PassQuinton OwensHVAC Final Inspection Mechanical Final OKInspector Comments: Plumbing 08/20/2010PassBrad JohnsonPlumbing Rough-in all piping tested and inspectedInspector Comments: Page 2 of 2