Loading...
HomeMy WebLinkAboutFIRE ALARM CONTROL PANEL PRODUCT INFO - 20-00467 - Les Schwab - Fire Alarm replacement.pdf XR150 Control Panel DMP.COM @DMPALARMS ▸Select Area, All/Perimeter or Home/Sleep/Away operation ▸Eight individual reporting areas with common areas ▸Up to eight supervised door access points and/or keypads, seven of which can be wireless ▸32-character names available for user, zone, area, profiles and group names ▸Up to four profiles per user ▸Fully supervised 10/100 network HSPA+ and LTE cellular communication ▸Communications diagnostics check network and cellular communication status from the keypad ▸Eight communication paths between the panel and monitoring center ▸Flexible system arming features with Instant Arming option ▸Lockdown operation from keypad or app ▸Up to 130 two-wire smoke detector or fire-initiating zones ▸10,000 user codes with 99 profiles ▸Mobile platform support via Virtual Keypad app ▸12,000 event buffer ▸Built-in phone line monitor ▸Multi-lingual menus available by user ▸1.5 amp 12 VDC smoke and auxiliary output with OVC protection ▸EASYconnect™ connection for the Virtual Keypad app when used with a network connection ▸Guest House operation allows up to two separate protected systems ▸Onboard 10/100 network communication ▸Plug-in HSPA+ and LTE cellular communicators allow for Virtual Keypad™ app and monitoring center connection ▸Flash updateable: No more firmware chips to replace ▸Adaptive Technology™ — Cost- effective supervised cellular backup ▸Up to 100 DMP 1100 SeriesTM wireless or wired LX-BusTM ▸Up to 99 schedules for areas, doors, outputs, holidays, Z-Wave® Favorites and profiles FEATURES DMP.COM @DMPALARMS FLEXIBLE COMMUNICATION The XR150 has transitioned from dialer-focused communications to a true network, cellular and Wi- Fi communications approach by providing stronger, multi-layered panel communications that ensure a constant link between the panel and monitoring center. The unique DMP Serial 3 format supports 32-character user, zone and area names to decrease the time and limit dependence on automation literal tables for message interpretation. Contact ID dialer format is also supported. NETWORK OR CELLULAR COMMUNICATION Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital dialer or cellular option. The 263 Series cellular communicators can be used as the primary path, providing installation flexibility where no landlines are available. They can be used as a stand-alone communicator without the need for a backup. When used as the backup path, the 263 Series provides the security of a communication link that continues to function, even when landlines are cut or compromised. This interface works over a variety of carriers in the USA and Canada. ADAPTIVE TECHNOLOGY™ If a current primary communication path becomes unavailable, Adaptive Technology directs the panel to make a seamless transition from one communication path to another, ensuring that no check-in or supervision messages are missed. This allows a system to be fully supervised when the primary communication path is unavailable, while minimizing expensive cell traffic when all paths are good. The panel is constantly checking the failed path to enable the panel to revert back to the primary path when communication is restored. TECHNOLOGY EASYconnect™ enables the control panel to establish an outbound connection to SecureCom Wireless™ over the network. This allows for an effortless installation of network panels, without any customer router programming, providing extremely quick app connection times. EIGHT COMMUNICATIONS PATHS Create, configure and manage up to eight communication paths between the panel and monitoring center. Each path has its own panel communication programming parameters and can be identified as either primary or backup. This enables installers to configure a reliable communication link, offering greater confidence that the panel will always be connected. ACCESS CONTROL BURGLARY INTEGRATION The XR150 is an integrated burglary, fire and access control system that can be configured for users to gain access and disarm the area with a single card read. AREAS Program up to eight areas with a variety of options, including independent arming. Each area has a unique name and may have its own account number. Common areas automatically arm when the last independent area is armed and disarm when the first independent area is disarmed. This is ideal for lobbies or areas where users need common access to specific areas only. COMMUNICATION FUNCTION DIAGNOSTICS The enhanced diagnostic menu enables technicians to check network and cellular communication status and cell signal strength from the keypad. WIRELESS ONE-BUTTON KEYFOB WITH PROX The 1144-1P is a wearable and portable panic button fob, programmable to function in multiple locations with alerts for lost fobs, late to test and low battery power. MOBILE PLATFORMS DMP mobile platforms provide you with the tools you need to build strong connections with your customers. The Virtual Keypad app puts a keypad on the user’s Apple iPhone®, iPad® or Android™ compatible devices. FALSE ALARM FEATURES Providing a way to reduce false alarms, both Cancel/Verify™ and the False Alarm Question prompt users to validate whether an alarm has occurred after entering their code. In a Home/Sleep/ Away or All/Perimeter system, the user can either press Cancel/Verify or Yes/No to confirm alarm status and send it to the monitoring center. DMP WIRELESS DMP 1100 Series wireless communication employs 900 MHz frequency-hopping spread-spectrum to ensure clear and accurate signal transmissions without interference in practically any environment. Receivers are alerted of transmitters that go missing with two-way communication. Each wireless transmitter communicates with the receiver using supervision messages. WIRELESS ENCRYPTION DMP’s 1100 Series E models are for customers who want to add the hardest layer of security. In addition to 900 MHz frequency-hopping spread-spectrum supervised communication, these models also offer full support for industry- standard 128-bit AES encryption over the air. For added security, DMP 1100 Series encrypted devices also allow you to enter your own passphrase for unique key generation, providing full encryption end to end. The encryption models are offered separately from existing 1100 Series devices. For the highest level of encryption, it is recommended that all devices on the system be E models, although each of the products are fully backward compatible with systems that do not support encryption, so they can be added to existing systems or operate as a stand-alone system. 1100 SERIES ENCRYPTED ▸1100XE Wireless Receiver ▸1100XHE Wireless High Power Receiver ▸1100RE Wireless Repeater ▸1101E Universal Transmitter ▸1103E Commercial Universal Transmitter ▸1106E Universal Transmitter ▸1135E Wireless Siren ▸1142E Wireless Two-Button Hold Up Transmitter ▸1144E Wireless Key Fobs LOCKDOWN For emergency situations, a Lockdown command can be issued from the keypad menu or via remote command to lock all doors designated as public. TEMPORARY CODES Temporary codes are user codes that can be entered with a finite date and specific time to expire. INTRUSION PANELS ZONE EXPANSION The XR150 provides up to 142 zones, programmable for burglary, fire and access applications. ▸10 Onboard Zones ▸Eight Keypads = 32 Zones ▸One Built-In LX Bus (100 zones) MULTIPLE CHIME TONES In Zone Information, you can assign one of three distinct tones to a Night or Exit zone to know easily and quickly by different tones where and when a zone is opened. This feature has true security applications both residentially and commercially. SIMPLE ZONE EXPANSION WITH THE 1154/1158 WIRELESS INPUT MODULES When a DMP panel is installed in the same location as a non-DMP panel, the 1154 can easily and quickly convert up to four existing hardwired zones from the old panel into wireless zones, and the 1158 can convert up to eight. Existing wiring does not have to be re-run, and existing contacts can be reused with the new system. ONE-MAN WALK TEST A special code is also available for installers to test the system. The One-Man Walk Test allows a single technician to check the panel response to burglary, fire, panic and supervisory zones. OUTPUTS The XR150 provides up to 106 outputs that can be activated by zone or system events, by schedule, through the User Menu or when a card is presented. Output Groups allow multiple outputs to activate with a single event and/or can be assigned to a particular user profile. REAL-TIME STATUS ENHANCES THIRD-PARTY INTEGRATION Alarm systems are increasingly being integrated with environmental control and home automation systems. With real- time status information from zones, doors and other outputs, XR150 Series panels are readily integrated with these third- party control and automation systems. See DMP.com/Integration_Partners. MULTIPLE LAUNGUAGE DISPLAY OPTION XR150 Series systems may be programmed to display the User Menu and Status Display text in multiple languages. FLEXIBILITY IN SCHEDULES Enhanced scheduling for areas, doors, outputs and holiday schedules offer flexibility for your customers. Ninety-nine programmable schedules are available and can be assigned to an area, door or output. The same schedule may be assigned to more than one area, door or output, making them reusable. A List key facilitates browsing through the list of stored names on the keypad. ▸Up to 8 schedules per profile ▸Up to 8 schedules per door ▸Up to 8 schedules per area ▸Up to 8 schedules per output ▸Up to 40 holiday dates KEYPAD SHORTCUT KEYS Time-saving shortcut keys provide easy one-button access to system control for frequently used functions like system arming. The shortcut keys enable users to arm, monitor zones, test or reset the system and perform a variety of other functions faster and easier. Shortcut keys include: All, Reset, Home, Chime, Perim and Sleep. Z-WAVE® SUPPORT Add up to 140 Z-Wave devices with the 738Zplus module for mobile control of lights, locks and thermostats. Up to 20 Favorites allow users to program multiple devices to respond to a single command or panel event like arming and disarming. Z-Wave devices can be controlled with the 7800/9800 Series Graphic Touchscreen Keypad and Virtual Keypad. CUSTOM ACTIONS In addition to controlling lights, locks and thermostats, users can also take advantage of several customizable actions that can be programmed into the panel. Users can select a combined sequence of actions, all based on specific Favorites, lights and locks to activate or deactivate Z-Wave devices, Favorites or outputs during specific times and days or specific zone trips. THINLINE™ KEYPADS The stylish and sleek 7000 Series Thinline™ LCD Keypads provide three two-button panic keys, AC power and armed LEDs, 32-character display, backlit logo and keyboard plus an internal sounder. The 7063 and 7073 keypads also include a built-in proximity reader for codeless arming and disarming. EIGHT INDEPENDENT ACCESS CONTROL DOORS Any access control reader with a Wiegand output can be connected to the XR150 Series panel. Attached card reader controls up to eight different doors. The XR150 system can restrict access by schedule, arming level or other criteria. The specific reason for access denial can be displayed on the keypad, stored in events, sent to the monitoring center and DMP Advanced Reporting. Anti-passback feature is also available. VALUABLE VISUAL ALARM INDICATOR In a normal state, both the keypad and logo backlighting remain blue on Aqualite™ keypads or green on Thinline keypads. However, during an alarm state, the keypad and logo turn red. The change in color allows individuals on-site to instantly recognize an alarm condition. 7800/9800 SERIES GRAPHIC TOUCHSCREEN KEYPAD Provides touchscreen control for all keypad functions. It has a slim profile in stylish gloss black or white finish with a 5-inch, full-color display. COMMERCIAL FIRE The DMP XR150 is also approved for commercial fire applications. Integrate intrusion, access and fire into a single application or use the XR150FC as a stand-alone commercial fire alarm control panel. See LT-1317 for more information. ZONE AUDIT DAYS This is a valuable auditing tool to determine whether a zone or device has not been tripped within a certain number of days. Whether the system is armed or disarmed, up to 365 days can elapse without the zone being tripped. Each time the zone is tripped, the counter restarts. After the countdown expires, a fault message is sent, and the timer begins the countdown again as per the programmed days. 7463 NETWORK THINLINE KEYPAD When you’re installing an XR Series alarm panel in a building that’s already wired for IP network, DMP’s new 7463 Network Keypad gives you the advantage of saving time by plugging into the existing network. Power the keypad from the included 12 VDC plugin transformer. Also included is a backup battery for four hours of standby power. Network keypads require XR Series Version 201. © 2020 Digital Monitoring Products, Inc. | LT-1286 | 20152 800-641-4282 | DMP.com 2500 N. Partnership Blvd, Springfield, MO 65803 Designed, engineered & manufactured in Springfield, MO using U.S. & global components LIMITED WARRANTY: DMP warrants that the products manufactured by DMP and described herein shall be free from defects of manufacture, labeling, and packaging for a period of three (3) years from the invoice date to the original Buyer, provided that representative samples of the defective products are returned to DMP for inspection…To read the full DMP Limited Warranty, go to DMP.com/Warranty or check the DMP Price List or Catalog. INTRUSION PANELS System Specifications Primary Power (included): 16.5 VAC 50 VA transformer Secondary Power: 12 VDC Battery Models: 365, 366, 368 or 369 Output Rating: Bell 1.5 Amps at 12 VDC Smoke and Auxiliary 1.5 Amps at 12 VDC Current Draw: 174 mA Enclosures: Material Cold-rolled steel Model 350 (Gray or Red) 17.5" W × 13.5" H × 3.5" D Model 350A (Gray) 17.5" W × 13.5" H × 3.75" D Model 352X (Gray) 14.5" W × 32" H × 4" D Model 352P (Gray) 14.5” W × 32” H × 4” D Model 341 (Gray) 12.75" W × 6.55" H × 3.15" D Certifications California State Fire Marshal (CSFM) New York FDNY FCC Part 68 FCC Part 15 Underwriters Laboratories (UL) Listed UL Bank, Safe, and Vault UL Commercial Fire UL Standard Line Security UL Encrypted Line Security NIST Validated Certificate #2350 and #2595 Underwriters Laboratories Canada (ULC) Listed For additional information, go to DMP.com/Compliance. Keypads 630F LCD Remote Fire Command 7000 Series Thinline Keypads 7000A Series Aqualite Keypads 7160 Thinline Series Keypad 7173 LCD Keypad 7463 Network Thinline Keypad 7800 Graphic Touchscreen Keypads 9060 Wireless Keypad 9063 Wireless Keypad w/ Prox Reader 9862 Wireless Touchscreen Keypads Expansion Modules 708 Bus Extender 710 Bus Splitter/Repeater 711 Single Zone Expansion 711S Zone Expansion Module 712-8 8-zone Expansion 714 4-zone Class B Expansion 714-8 8-zone Class B Expansion 714-16 16-zone Class B Expansion 715 4-zone 2-wire Smoke Expansion 715-8 8-zone 2-wire Smoke Expansion 715-16 16-zone 2-wire Smoke Expansion 716 Output Expansion, 4 Form C relays, 4 open collector outputs 717 Graphic Annunciator: 20 open collector outputs 736P Radionics Interface 738A Ademco Interface Module 738I ITI Interface Module 738T Wireless Translator Cellular Communicators 263LTE-V/381-2 LTE Communicator, Verizon 263LTE-A/381-2 LTE Communicator, AT&T Auxiliary Modules 860 Relay Output Module 865 Style W/X Notification Circuit Module 866 Style W Notification Circuit Module 867 LX-Bus Notification Circuit Module 869 Style D Initiating Circuit Module 893A Dual Phone Line Module Power Supplies 505-12/LX 5 Amps @ 12 VDC 505-12L 5 Amps @ 12 VDC 505-12A 5 Amps @ 12 VDC Smoke/Heat Detectors 2W-BLX Conventional Smoke 2WT-BLX Conventional Smoke/Heat Intrusion Devices Virtually any other standard intrusion detectors Access Control 352M Access Control Enclosure 352PM Access Control Enclosure 734 Access Control Module 734N Network Access Control Module 734N-POE Network Access Control Module 1134 Wireless Access Control Module OP-08CB REX Motion Detector Proximity Readers and Credentials DMP ProxPatch Monitoring Center Receivers SCS-1R Security Control Receiver SCS-105 Single-Line DMP Serial 3 Receiver compatible with receivers that accept Standard CID, DD or DMP Serial 3 messaging SCS-VR (Virtual Receiver) Software-only solution that runs on a server for network IP and cellular communications DMP Wireless 1100X Receiver 1100XH High Power Receiver 1100R Repeater 1101 Universal Transmitter, Internal and External Contacts 1102 Universal Transmitter, External Contact 1103 Universal Transmitter, External Contact 1106 Universal Transmitter, Internal and External Contact 1107 Micro Window Transmitter 1108 Wireless Doorbell Module 1114 Four-Zone Expander 1115 Wireless Temperature Sensor and Flood Detector 1116 Relay Output 1117 LED Annunciator 1118 Remote Indicator Light 1119 Door Sounder 1122 Wireless PIR 1126R 360 Ceiling Mount PIR 1127C Wall Mount Curtain PIR 1127W Wall Mount Wide Angle PIR 1128 Glassbreak Detector 1131 Recessed Contact 1135 Siren, 100 dB 1136 Wireless Remote Chime 1137 LED Emergency Light 1139 Bill Trap 1141 Wall Button 1142 Two-Button Hold-up Transmitter 1142BC Two-Button Belt Clip Hold-up Transmitter 1144-4 Four-Button Key Fob 1144-2 Two-Button Key Fob 1144-1 One-Button Key Fob 1144-2P Two-Button Key Fob with Prox Patch 1144-1P One-Button Key Fob with Prox Patch 1144-D Dual-Button Key Fob 1148 Personal Pendant 1154 Wireless Four-Zone Input Module 1158 Wireless Eight-Zone Input Module 1164 Smoke Detector with Synchronized Sounder 1164NS-W Wireless Smoke Detector with No Sounder 1166 Wireless Smoke Detector Ring 1168 Wireless Smoke/CO/Low Temp Detector 1183-135F Heat Detector (Fixed) 1183-135R Heat Detector (Rate of Rise) 1184 Carbon Monoxide Detector Encrypted Wireless Models 1100XE Wireless Receiver 1100XHE Wireless High Power Receiver 1100RE Wireless Repeater 1101E Universal Transmitter 1103E Commercial Universal Transmitter 1106E Universal Transmitter 1135E Wireless Siren 1142E Wireless Two-Button Hold Up Transmitter 1144E Wireless Key Fobs Accessories 270 Network Transient Suppressor 277 Commercial Fire Buzzer Module 300 Four-wire Harness 303 Silence/Reset Push-Button 305 Plug-in Output Relay 306 Tamper Harness 307-S Screw-On Tamper Switch 3012 Clip-On Tamper Switch 335 Intrusion Siren 370 Lightning Suppressor 374 Surge Voltage Suppressor 431 Output Harness 738Z+ Z-Wave Interface Module 861 Power Distribution Module Dealer Management Dealer Admin™ Remote Link™ Programming Software End User Management Virtual Keypad™ VirtualKeypad.com™ System Link™ End-User Management Software Entré™ Access Control Software COMPATIBILITY REFERENCE SHEET