HomeMy WebLinkAboutTRUSS SPECS - 20-00471 - 855 S 2380 W - New SFRJob
20-066777T
Truss
A1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF18B3 PRINCETON B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Mon Jun 8 17:06:42 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:H5GrJiAZnGvlqM78tRQnI7zMua6-x8l8WxMRIr3t5?mX1YD1V8NTn2Dn39hiBfcO5Az8GTx
Scale = 1:55.4
T2 T2
B1
ST7
ST6
ST5
ST4
ST3
ST2
ST1
ST6
ST5
ST4
ST3
ST2T1 T1
B1
ST1
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P Q
AD AC AB AA Z Y X W V U T S R
4x5
3x4
5x6
5x6
5x6
3x4
29-0-0
29-0-0
-1-0-0
1-0-0
14-6-0
14-6-0
29-0-0
14-6-0
30-0-0
1-0-0
0-
4
-
5
8-
9
-
1
3
9-
4
-
9
0-
4
-
5
7.00 12
Plate Offsets (X,Y)-- [E:0-3-0,0-3-0], [M:0-3-0,0-3-0], [X:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.03
0.13
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
Q
Q
P
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 168 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std *Except*
ST7,ST6: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F
1.6E
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt I-X
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 29-0-0.
(lb) - Max Horz B=202(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) B, Y, Z, AA, AB, AC, AD, W, V, U, T, S, P, R
Max Grav All reactions 250 lb or less at joint(s) B, X, Y, Z, AA, AB, AC, AD, W, V, U, T, S, P, R
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=29ft; eave=2ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Corner(3) -1-0-14 to 1-11-2, Exterior(2) 1-11-2 to 14-6-0, Corner(3) 14-6-0 to 17-6-0,
Exterior(2) 17-6-0 to 30-0-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, Y, Z, AA, AB, AC,
AD, W, V, U, T, S, P, R.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-066777T
Truss
A2
Truss Type
Common
Qty
8
Ply
1
KARTCHNER SF18B3 PRINCETON B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Mon Jun 8 17:06:45 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:H5GrJiAZnGvlqM78tRQnI7zMua6-LjRG8zOKbmRSySV6ihmk7n?qrF7iGUP9tdq2iUz8GTu
Scale = 1:53.6
T2 T2
B1
W1
W2
W1
W2T1 T1
B1B2A
B
C
D
E
F
G
I H
J
K L
M
N O
5x6
3x6 5x8 5x8
7x10
7x10
3x6
9-8-0
9-8-0
19-4-0
9-8-0
29-0-0
9-8-0
-1-0-0
1-0-0
7-3-0
7-3-0
14-6-0
7-3-0
21-9-0
7-3-0
29-0-0
7-3-0
30-0-0
1-0-0
0-
4
-
5
8-
9
-
1
3
9-
4
-
9
0-
4
-
5
7.00 12
Plate Offsets (X,Y)-- [B:0-3-3,0-1-8], [F:0-3-3,0-1-8], [H:0-4-0,0-3-0], [I:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.66
0.53
0.26
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.37
-0.45
0.07
0.07
(loc)
H-I
H-I
F
F-H
l/defl
>934
>753
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 127 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W2: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-7-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=1508/0-5-8 (min. 0-1-10), F=1508/0-5-8 (min. 0-1-10)
Max Horz B=-202(LC 10)
Max UpliftB=-270(LC 12), F=-270(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-J=-2253/362, C-J=-2125/388, C-K=-1953/406, D-K=-1770/420, D-L=-1770/420,
E-L=-1953/406, E-M=-2125/388, F-M=-2253/362
BOT CHORD B-I=-228/1815, I-N=-50/1184, N-O=-50/1184, H-O=-50/1184, F-H=-238/1815
WEBS D-H=-141/786, E-H=-571/232, D-I=-141/786, C-I=-571/232
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-14 to 1-11-2, Interior(1) 1-11-2 to 14-6-0, Exterior(2) 14-6-0 to 17-6-0,
Interior(1) 17-6-0 to 30-0-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=270,
F=270.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-066777T
Truss
A3
Truss Type
Common
Qty
10
Ply
1
KARTCHNER SF18B3 PRINCETON B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Mon Jun 8 17:06:47 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:H5GrJiAZnGvlqM78tRQnI7zMua6-I5Z1ZfQa7NhABmfUp6pCCC4AH3p2kOvRLxJ9nNz8GTs
Scale = 1:52.9
T2 T2
B1
W2
W1 W1
W2T1
T3
B3B2A
B
C
D
E
F
H G
I
J K
L
M N
5x6
3x6 5x8
7x10
5x8
7x10
4x5
9-8-0
9-8-0
19-4-0
9-8-0
28-9-0
9-5-0
-1-0-0
1-0-0
7-3-0
7-3-0
14-6-0
7-3-0
21-9-0
7-3-0
28-9-0
7-0-0
0-
4
-
5
8-
9
-
1
3
9-
4
-
9
0-
6
-
1
7.00 12
Plate Offsets (X,Y)-- [B:0-3-3,0-1-8], [F:0-0-0,0-1-0], [G:0-4-0,0-3-0], [H:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.66
0.53
0.26
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.37
-0.45
0.06
0.09
(loc)
G-H
G-H
F
F-G
l/defl
>933
>753
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 124 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W2: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-7-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=1506/0-5-8 (min. 0-1-10), F=1392/Mechanical
Max Horz B=199(LC 11)
Max UpliftB=-271(LC 12), F=-216(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-I=-2250/365, C-I=-2122/388, C-J=-1949/407, D-J=-1766/420, D-K=-1766/432,
E-K=-1949/418, E-L=-2115/399, F-L=-2247/382
BOT CHORD B-H=-255/1812, H-M=-69/1182, M-N=-69/1182, G-N=-69/1182, F-G=-255/1807
WEBS C-H=-571/232, D-H=-139/785, D-G=-142/783, E-G=-566/231
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=29ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-14 to 1-11-2, Interior(1) 1-11-2 to 14-6-0, Exterior(2) 14-6-0 to 17-6-0,
Interior(1) 17-6-0 to 28-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=271,
F=216.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-066777T
Truss
A4
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF18B3 PRINCETON B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Mon Jun 8 17:06:49 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:H5GrJiAZnGvlqM78tRQnI7zMua6-EUgn_LRqf_xtQ4otxXrgHdAf0scOCKQkoFoFrGz8GTq
Scale = 1:54.6
T2 T2
B1
ST7
ST6
ST5
ST4
ST3
ST2
ST1
ST6
ST5
ST4
ST3
ST2
T1
T3
B2
ST1
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
AC AB AA Z Y X W V U T S R Q
4x5
3x4
5x6
5x6
5x6
3x4
28-9-0
28-9-0
-1-0-0
1-0-0
14-6-0
14-6-0
28-9-0
14-3-0
0-
4
-
5
8-
9
-
1
3
9-
4
-
9
0-
6
-
1
7.00 12
Plate Offsets (X,Y)-- [E:0-3-0,0-3-0], [M:0-3-0,0-3-0], [W:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.03
0.13
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
0.00
0.00
(loc)
A
A
P
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 165 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std *Except*
ST7,ST6: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F
1.6E
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt I-W
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 28-9-0.
(lb) - Max Horz B=199(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) B, X, Y, Z, AA, AB, AC, V, U, T, S, R, Q
Max Grav All reactions 250 lb or less at joint(s) B, W, X, Y, Z, AA, AB, AC, V, U, T, S, R, P, Q
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=29ft; eave=2ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Corner(3) -1-0-14 to 1-11-2, Exterior(2) 1-11-2 to 14-6-0, Corner(3) 14-6-0 to 17-6-0,
Exterior(2) 17-6-0 to 28-9-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, X, Y, Z, AA, AB, AC
, V, U, T, S, R, Q.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-066777T
Truss
B1
Truss Type
GABLE
Qty
1
Ply
2
KARTCHNER SF18B3 PRINCETON B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Mon Jun 8 17:06:51 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:H5GrJiAZnGvlqM78tRQnI7zMua6-AsoYP0T4BcBbgNyG2xt8M2Fujg7rg2m1FZHMw8z8GTo
Scale = 1:44.7
T1 T1
B1
W1
W2 W3
W4
W2W3
W4
ST1
ST2
ST1
ST2
ST3
ST4
ST5
B1
A
B
C
D
E
F
G
J I HWXYZAAABAC AD AE
4x12
5x8
4x12
12x12
6x8
12x12
6x8
12x12 3x6 3x6 3x6 3x6
Special
Special
Special
Special
Special Special Special Special
Special
Special
5-4-6
5-4-6
10-8-12
5-4-6
16-1-2
5-4-6
21-5-8
5-4-6
3-6-15
3-6-15
7-1-13
3-6-15
10-8-12
3-6-15
14-3-11
3-6-15
17-10-9
3-6-15
21-5-8
3-6-15
0-
4
-
5
6-
7
-
6
0-
4
-
5
7.00 12
Plate Offsets (X,Y)-- [A:0-3-6,0-1-12], [G:0-3-6,0-1-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.57
0.73
0.91
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.22
-0.30
0.07
0.10
(loc)
H-I
H-I
G
H-I
l/defl
>999
>828
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 305 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x8 DF 1950F 1.7E or 2x8 DF SS
WEBS 2x4 DF Stud/Std *Except*
W1: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-5-10 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)A=8066/0-5-8 (min. 0-4-5), G=7772/0-5-8 (min. 0-4-2)
Max Horz A=-136(LC 23)
Max UpliftA=-1306(LC 8), G=-1258(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-12774/2084, B-C=-12582/2074, C-D=-8595/1462, D-E=-8595/1462, E-F=-12542/2068,
F-G=-12731/2077
BOT CHORD A-W=-1761/10968, W-X=-1761/10968, J-X=-1761/10968, J-Y=-1427/9167, Y-Z=-1427/9167,
I-Z=-1427/9167, I-AA=-1425/9151, AA-AB=-1425/9151, AB-AC=-1425/9151, H-AC=-1425/9151,
H-AD=-1754/10927, AD-AE=-1754/10927, G-AE=-1754/10927
WEBS D-I=-1383/8262, E-I=-2719/503, E-H=-647/4074, C-I=-2743/507, C-J=-654/4118
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x8 - 2 rows staggered at 0-5-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate
grip DOL=1.33
5) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
6) All plates are 1.5x4 MT20 unless otherwise indicated.
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=1306
, G=1258.
11) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
Job
20-066777T
Truss
B1
Truss Type
GABLE
Qty
1
Ply
2
KARTCHNER SF18B3 PRINCETON B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Mon Jun 8 17:06:52 2020 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:H5GrJiAZnGvlqM78tRQnI7zMua6-e3MwcMTjyvKSHXXScfONvFo3T4T4PU0AUD1wSaz8GTn
NOTES-
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1378 lb down and 230 lb up at 1-6-4, 1378 lb down and 230 lb up at 3-6-4
, 1378 lb down and 230 lb up at 5-6-4, 1378 lb down and 230 lb up at 7-6-4, 1378 lb down and 230 lb up at 9-6-4, 1378 lb down and 230 lb up at 11-6-4, 1378 lb down and
230 lb up at 13-6-4, 1378 lb down and 230 lb up at 15-6-4, and 1378 lb down and 230 lb up at 17-6-4, and 1378 lb down and 230 lb up at 19-6-4 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, D-G=-84, A-G=-14
Concentrated Loads (lb)
Vert: J=-1378(B) W=-1378(B) X=-1378(B) Y=-1378(B) Z=-1378(B) AA=-1378(B) AB=-1378(B) AC=-1378(B) AD=-1378(B) AE=-1378(B)
Job
20-066777T
Truss
C1
Truss Type
Common
Qty
1
Ply
1
KARTCHNER SF18B3 PRINCETON B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Mon Jun 8 17:06:54 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:H5GrJiAZnGvlqM78tRQnI7zMua6-bRUg12VzTXaAXrhrk4Rr_gtWmtKatc7TyXW0XTz8GTl
Scale = 1:22.8
T1 T1
B1
ST3
ST2
ST1
ST2
ST1
A
B
C
D
E
F
G
H
I
N M L K J
4x5
3x4 3x4
11-2-0
11-2-0
-1-0-0
1-0-0
5-7-0
5-7-0
11-2-0
5-7-0
12-2-0
1-0-0
0-
4
-
5
3-
7
-
6
4-
2
-
2
0-
4
-
5
7.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.03
0.04
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
I
I
H
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 47 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 11-2-0.
(lb) - Max Horz B=-86(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) B, H, M, N, K, J
Max Grav All reactions 250 lb or less at joint(s) B, H, L, M, N, K, J
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=2ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Corner(3) -1-0-14 to 1-11-2, Exterior(2) 1-11-2 to 5-7-0, Corner(3) 5-7-0 to 8-7-0,
Exterior(2) 8-7-0 to 12-2-14 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, H, M, N, K, J.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-066777T
Truss
D1
Truss Type
Monopitch
Qty
9
Ply
1
KARTCHNER SF18B3 PRINCETON B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Mon Jun 8 17:06:55 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:H5GrJiAZnGvlqM78tRQnI7zMua6-3e22FOWbEqi18?G1Hny4WuQdJHd2c3zdABFa3vz8GTk
Scale = 1:13.5
T1
W1
B1
A
B
C
D
E
1.5x4
2x4
1.5x4
4-10-8
4-10-8
-1-0-0
1-0-0
4-10-8
4-10-8
5-0-0
0-1-8
0-
4
-
0
2-
2
-
8
2-
6
-
1
2
1-
1
1
-
0
0-
3
-
8
2-
2
-
8
4.50 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.34
0.14
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.03
-0.04
0.00
0.00
(loc)
B-D
B-D
D
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 18 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-10-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=344/0-3-8 (min. 0-1-8), D=218/0-1-8 (min. 0-1-8)
Max Horz B=78(LC 9)
Max UpliftB=-88(LC 12), D=-32(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-10 to 1-11-6, Interior(1) 1-11-6 to 4-10-4 zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip
DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Bearing at joint(s) D considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, D.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-066777T
Truss
D2
Truss Type
Monopitch
Qty
5
Ply
1
KARTCHNER SF18B3 PRINCETON B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Mon Jun 8 17:06:57 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:H5GrJiAZnGvlqM78tRQnI7zMua6-?09pg4XrmSylOIQPPC_YcJV0C5KP4zSweUkh7oz8GTi
Scale = 1:11.7
T1
W1
B1
A
B
C
D
E
F
1.5x4
2x4
1.5x4
3-10-8
3-10-8
-1-0-0
1-0-0
3-10-14
3-10-14
4-0-0
0-1-2
0-
4
-
0
1-
1
0
-
0
2-
2
-
4
1-
6
-
8
0-
3
-
8
1-
1
0
-
0
4.50 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.18
0.08
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.02
0.00
0.00
(loc)
B-D
B-D
D
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 14 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-10-14 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=298/0-3-8 (min. 0-1-8), D=165/0-1-8 (min. 0-1-8)
Max Horz B=63(LC 9)
Max UpliftB=-83(LC 12), D=-22(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-10 to 1-11-6, Interior(1) 1-11-6 to 3-10-4 zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip
DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Bearing at joint(s) D considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, D.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-066777T
Truss
D3
Truss Type
Monopitch
Qty
6
Ply
1
KARTCHNER SF18B3 PRINCETON B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Mon Jun 8 17:06:59 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:H5GrJiAZnGvlqM78tRQnI7zMua6-xPHZ4lZ6I3CTdcZoWd00hkaMQu0tYsxC5oDnCgz8GTg
Scale = 1:13.6
T1
B1
W1
A
B
C
D
E
F
2x4
1.5x4
1.5x4
3-10-8
3-10-8
3-10-8
-1-0-0
1-0-0
3-10-14
3-10-14
5-0-0
1-1-2
0-
4
-
0
2-
2
-
8
2-
6
-
1
2
1-
1
0
-
0
0-
3
-
8
4.50 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.14
0.08
0.07
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.02
0.00
0.00
(loc)
B-E
B-E
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 16 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-10-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=284/0-3-8 (min. 0-1-8), E=277/0-1-8 (min. 0-1-8)
Max Horz B=86(LC 12)
Max UpliftB=-59(LC 12), E=-92(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS C-E=-251/172
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-10 to 1-11-6, Interior(1) 1-11-6 to 5-0-0 zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip
DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Bearing at joint(s) E considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) E.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, E.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-066777T
Truss
E1
Truss Type
Monopitch
Qty
7
Ply
1
KARTCHNER SF18B3 PRINCETON B
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Mon Jun 8 17:07:01 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:H5GrJiAZnGvlqM78tRQnI7zMua6-toPJVRaMqgSAtwjBe23Vm9giviiO0nSVZ6iuGZz8GTe
Scale = 1:10.6
T1
W1
B1
A
B
C
D
1.5x4
2x4
1.5x4
1-10-8
1-10-8
-1-0-0
1-0-0
1-10-8
1-10-8
2-0-0
0-1-8
0-
4
-
5
1-
6
-
5
2-
1
-
1
1-
2
-
1
3
0-
3
-
8
1-
6
-
5
7.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.08
0.02
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.00
-0.00
0.00
0.00
(loc)
B
B
D
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 9 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 1-10-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=212/0-5-8 (min. 0-1-8), D=60/0-1-8 (min. 0-1-8)
Max Horz B=53(LC 9)
Max UpliftB=-75(LC 12), D=-14(LC 9)
Max GravB=212(LC 1), D=61(LC 17)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Bearing at joint(s) D considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, D.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard