Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 10-00271 - Fat Cats - RemodelPermit Inspection Summary Permit Status of (Open) as of Report Date: 06/12/2020 12:18 pm Permit Details Permit Number: 10-00271 Fat Cats - Remodel 475 N 2nd E Commercial - Remodel Permit Issued Date: 05/08/2014 Permit Inspection Statistics 12Total Inspections Completed: 10Total Inspections Passed: Inspection Pass Rate: 83.33% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 08/23/2010PassPLL ADMINFraming/Structure Inspection Framing completed so far looks good Kitchen area OK (9/3 QO) As per Jon Berry. Inspector Comments: 08/26/2010PassPLL ADMINSheetrock/Drywall Inspection 10/12/2010PassPLL ADMINBuilding Final as per Jon Berry.Inspector Comments: Electrical 08/24/2010PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in Approved for cover in the newly framed areas in the back of the building for mini-golf area. Inspector Comments: 09/03/2010PassBret StoddardCOM-A, COM-R, COM-T Electrical Rough-in Approved for cover in the kitchen area framed walls-need to maintain access to the flex 90's in the wall down low-cabinet will be there and they said they would. Inspector Comments: 03/24/2011FailBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Need to supply us with the installation instructions for the power supplies for the star shaped LED lights on the front of the theater, call for a re-inspect when ready. Inspector Comments: Fire 12/17/2010FailPLL ADMINFire Department Final Inspection The fire alarm system requires a horn strobe in the party room. A relay switch is required to be installed so the lighting in the miniature golf area automatically turns on when the fire alarm is activated. as per Brad Johnson. Inspector Comments: 02/16/2011PassPLL ADMINFire Department Final Inspection All corrections made, approved for final, per Brad Johnson.Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 10-00271 Fat Cats - Remodel 475 N 2nd E Commercial - Remodel Permit Status of (Open) as of Report Date: 06/12/2020 12:18 pm Permit Inspection Summary Mechanical 09/27/2010PassPLL ADMINHVAC Rough-in Hood exhaust inspected M/U air ducting not installed As per Jon Berry. Inspector Comments: 10/12/2010PassPLL ADMINHVAC Final Inspection Hood tested good, CFM ok, hood interlock system worked. As per Jon Berry. Inspector Comments: Plumbing 09/03/2010PassPLL ADMINPlumbing Rough-in As per Brad JohnsonInspector Comments: 11/30/2010PassPLL ADMINPlumbing Final Inspection Inspections Required COM, COM-A, COM-R, and COM-T Electrical Final Inspection Page 2 of 2