Inspection
Summary
Permit Status of (Open) as of Report Date: 06/12/2020 11:26 am
Permit Details Permit Number: 10-00296
364 & 370 Bare St - Duplex
364 & 370 Bare St
New Single Family Residence
Permit Issued Date: 11/04/2010
Permit Inspection Statistics
10Total Inspections Completed:
7Total Inspections Passed:
Inspection Pass Rate: 70.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building
09/10/2010PassTed DyeResidential Framing/Structure Inspection
370 OK 364 OKInspector Comments:
09/14/2010FailTed DyeResidential Insulation Inspection
-Insulation in crawlspace should be up against subfloor - Vents blocked off
w/insulation and allows air to flow above insulation ventilation needed in attic
Inspector Comments:
09/17/2010PassTed DyeResidential Sheetrock/Drywall Inspection
11/04/2010PassTed DyeResidential Building Final
370 - 364 ApprovedInspector Comments:
Electrical
08/27/2010PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power 1 - meterInspector Comments:
09/09/2010PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for coverInspector Comments:
09/09/2010FailBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
-Need nailplates for ser cale above panels. - Transformer cannot be on small
appliance branch circuit in kitchen. Call for reinspect when ready.
Inspector Comments:
11/04/2010PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final & CO 364 and 370Inspector Comments:
Mechanical
11/04/2010FailQuinton OwensHVAC Final Inspection
Closet by front door must be limited to opening only about 90deg to meet
clearance requirement in front of heater (Working clearance for water heater?)
Inspector Comments:
Plumbing
11/05/2010PassJohn MillarPlumbing Final Inspection
Plumbing Final ApprovedInspector Comments: