HomeMy WebLinkAboutCONCRETE TEST 2 - 19-00732 - The Grove at Thomson Farms - Hawthorn - 30 Unit Bldg 3Project Name:
Client:
Mix Number:
Project Number:
Ticket Number:
Load Amount:
Admixtures:
Tested By:
Date and Time:
Compressive Strength of Concrete Test Specimens
Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511)
Slump (Inches):
Entrained Air (%):
Concrete Temperature:
Ambient Temperature:
Test Results:Minimum:Maximum:
Cylinder #
Lab Test Data: (ASTM C39, C42, C617, and C1231)
Break Age
Cylinder
Diameter (in)
Area
(in² )
Break
Date
Maximum Load
(lbs)
Break
Type
Compressive
Strength (psi)Required 28 day
Strength (psi)
°F
°F
Reviewed By:
Supplier:
Test Location:
Unit Weight (PCF):Set # :
Cylinders Picked Up By: Date and Time:
Hi / Low Temperatures
Remarks:
28-day Average Strength
5,912
Thomson Farms
Still Water Equity Partnership
142
20001
13377
10 of 30 yards
MP 322, MA AE 90
Forrest Pelton
4/30/2020 12:00 PM
7
4.6
78.6
53.2
5
6
61A
61E
61C
61B
61D
4
4
4
4
05/07/20
05/28/20
05/28/20
05/28/20
55,015
73,785
75,285
73,910
2 4,0004,376
5,869
5,989
5,879
12.57
Walter's Ready Mix
Building 7 Exterior foundation walls on East side
between Girdlines 3 and 2.5.
7
28
28
28
H
12.57
12.57
12.57
Super plasticizer was used to increase slump
1 of 1
F. Pelton 05/01/2020 8:30 AM
2
1
1