Loading...
HomeMy WebLinkAboutCONCRETE TEST 4 - 19-00731 - The Grove at Thomson Farms - Hickory - 30 Unit Bldg 4Project Name: Client: Mix Number: Project Number: Ticket Number: Load Amount: Admixtures: Tested By: Date and Time: Compressive Strength of Concrete Test Specimens Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511) Slump (Inches): Entrained Air (%): Concrete Temperature: Ambient Temperature: Test Results:Minimum:Maximum: Cylinder # Lab Test Data: (ASTM C39, C42, C617, and C1231) Break Age Cylinder Diameter (in) Area (in² ) Break Date Maximum Load (lbs) Break Type Compressive Strength (psi)Required 28 day Strength (psi) °F °F Reviewed By: Supplier: Test Location: Unit Weight (PCF):Set # : Cylinders Picked Up By: Date and Time: Hi / Low Temperatures Remarks: 28-day Average Strength Thomson Farms Still Water Equity Partnership 170 TF 20001 13986 11 of 120 Yards MS AC 534, MP 322 F Pelton 05-19-2020, 7:45 6.5 1.75 59.7 42 5 2 92A 92E 92C 92B 92D 4 05-26 06-11 06-11 06-11 45,360 5 3,5003,60812.57 Walters Ready Mix Interior slab of Building 6. 7 28 28 28 H Superplastisizer was added which increased slump. 2 of 3 Project Name: Client: Mix Number: Project Number: Ticket Number: Load Amount: Admixtures: Tested By: Date and Time: Compressive Strength of Concrete Test Specimens Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511) Slump (Inches): Entrained Air (%): Concrete Temperature: Ambient Temperature: Test Results:Minimum:Maximum: Cylinder # Lab Test Data: (ASTM C39, C42, C617, and C1231) Break Age Cylinder Diameter (in) Area (in² ) Break Date Maximum Load (lbs) Break Type Compressive Strength (psi)Required 28 day Strength (psi) °F °F Reviewed By: Supplier: Test Location: Unit Weight (PCF):Set # : Cylinders Picked Up By: Date and Time: Hi / Low Temperatures Remarks: 28-day Average Strength Thomson Farms Still Water Equity Partnership 170 TF 20001 13980 11 of 120 Yards MS AC 534, MP 322 F Pelton 05-19-2020, 6:00 8.25 1.5 64.9 42 5 2 91A 91E 91C 91B 91D 4 05-26 06-11 06-11 06-11 45,630 6 3,5003,63012.57 Walters Ready Mix Interior slab of Building 6. 7 28 28 28 H Superplastisizer was added which increased slump. Project Name: Client: Mix Number: Project Number: Ticket Number: Load Amount: Admixtures: Tested By: Date and Time: Compressive Strength of Concrete Test Specimens Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511) Slump (Inches): Entrained Air (%): Concrete Temperature: Ambient Temperature: Test Results:Minimum:Maximum: Cylinder # Lab Test Data: (ASTM C39, C42, C617, and C1231) Break Age Cylinder Diameter (in) Area (in² ) Break Date Maximum Load (lbs) Break Type Compressive Strength (psi)Required 28 day Strength (psi) °F °F Reviewed By: Supplier: Test Location: Unit Weight (PCF):Set # : Cylinders Picked Up By: Date and Time: Hi / Low Temperatures Remarks: 28-day Average Strength Thomson Farms Still Water Equity Partnership 142 20001 13688 10 Yards MP 322, MA AE 90, Super Plasticizer D. Aust 05/08/2020 3:00 PM 7 6.5 70 66 8 4.5 7.5 72A 72E 72C 72B 72D 4 05/15/20 06/05/20 06/05/20 06/05/20 58,565 2 4,0004,65912.57 Walters Ready Mix, INC. Building #6, Line C 0.5, 1.0 7 28 28 28 H 139.4 72 Project Name: Client: Mix Number: Project Number: Ticket Number: Load Amount: Admixtures: Tested By: Date and Time: Compressive Strength of Concrete Test Specimens Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511) Slump (Inches): Entrained Air (%): Concrete Temperature: Ambient Temperature: Test Results:Minimum:Maximum: Cylinder # Lab Test Data: (ASTM C39, C42, C617, and C1231) Break Age Cylinder Diameter (in) Area (in² ) Break Date Maximum Load (lbs) Break Type Compressive Strength (psi)Required 28 day Strength (psi) °F °F Reviewed By: Supplier: Test Location: Unit Weight (PCF):Set # : Cylinders Picked Up By: Date and Time: Hi / Low Temperatures Remarks: 28-day Average Strength Thomson Farms Still Water Equity Partnership 142 20001 13635 10 of 30 yards MP 322, MA AE 90 F Pelton 05-07-2020, 2:00 PM 7.5 6.5 59.9 55 5 6 67A 67E 67C 67B 67D 4 05/14/20 06/04/20 06/04/20 06/04/20 44,340 23,52712.57 Walters Ready Mix Building 6 7 28 28 28 H Super plastisizer was added, which increased the slump. Project Name: Client: Mix Number: Project Number: Ticket Number: Load Amount: Admixtures: Tested By: Date and Time: Compressive Strength of Concrete Test Specimens Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511) Slump (Inches): Entrained Air (%): Concrete Temperature: Ambient Temperature: Test Results:Minimum:Maximum: Cylinder # Lab Test Data: (ASTM C39, C42, C617, and C1231) Break Age Cylinder Diameter (in) Area (in² ) Break Date Maximum Load (lbs) Break Type Compressive Strength (psi)Required 28 day Strength (psi) °F °F Reviewed By: Supplier: Test Location: Unit Weight (PCF):Set # : Cylinders Picked Up By: Date and Time: Hi / Low Temperatures Remarks: 28-day Average Strength Thomson Farms Still Water Equity Partnership 170 TF 20001 13996 11 of 120 Yards MS AC 534, MP 322 F Pelton 05-19-2020, 9:00 7.5 2 60 46 5 2 93A 93E 93C 93B 93D 4 05-26 06-11 06-11 06-11 47,785 6 3,5003,80112.57 Walters Ready Mix Interior slab of Building 6. 7 28 28 28 H Superplastisizer was added which increased slump. 3 of 3