HomeMy WebLinkAboutREVIEW REPORT BUILDING REVISIONS - 20-00273 - Madison High School Field HouseReview Report Current --- Building Review Status: REVISIONS Application Number: 20-00273Permit Details Application Received Date: 04/28/2020 New Commercial Building Application Approved Date: Application Approved Status: ACCEPTED 04/29/2020 2300 University Blvd 2300 University Blvd - MHS Field House Status of Plan Reviews Completed 05/01/2020--- Plumbing Review COMPLETED 05/01/2020--- HVAC Review COMPLETED 05/05/2020--- Electrical Review COMPLETED 05/28/2020--- Building Review REVISIONS Permit Review Status Plan Reviews Still in Progress DESCRIPTION COMMENTS STA TUS *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! Handrails and Guards meet the requirements of IBC Sections 1014 and 1015 REVISIONSNot shown *Revisions Response : Stairways meet the requirements of IBC Section 1011 & 1019 REVISIONSNot shown *Revisions Response : Checked for linked cases N/A Ramps meet the requirements of IBC Section 1012 COMPLETED Use classification is identified as per IBC Section 302 Classification is E COMPLETED Type of construction is identified.III-B COMPLETED Fire resistance rating of building elements meet Sect. 704 & Table 601 COMPLETED Exterior walls meet the requirements of IBC Section 705 COMPLETED Exterior wall openings meet the requirements of IBC Section 705.8 COMPLETED Reviewed By: Ted Dye Review Date: 05/28/2020 Plan Review Details ted.dye@rexburg.org --- Building Review Status: REVISIONS Page 1 of 3 Approval of plans does not constitute approval of variance from code --- Building Review (Continued) D ESCRIPTIO N CO MMEN TS STATUS Fire walls meet the requirements of IBC Section 706 COMPLETED Fire partitions meet the requirements of IBC Section 708 COMPLETED Insulation materials meet the requirements of Section 720 COMPLETED Automatic sprinklers are provided or exempted as per IBC Section 903.2 COMPLETED Means of egress meets requirements of IBC Section 1003 and 1005 COMPLETED Occupant load is identified on plans as per IBC Section 1004 Occupant load 955 COMPLETED Accessible Means of Egress complies with IBC Section 1009 COMPLETED Doors meet the requirements of IBC Section 1010 COMPLETED Landings at doors meet the requirements of IBC Sections 1010.1.5 and 1010.1.6 COMPLETED Panic Hardware shall be installed as per IBC Section 1010.1.10 COMPLETED Exit Access meets the requirements of IBC Section 1016 COMPLETED Corridors meet the requirements of IBC Section 1020 COMPLETED Exits meet the requirements of IBC Sections 1022 and 1006 COMPLETED Exit Discharge meets the requirements of IBC Section 1028 COMPLETED All Accessible Routes meet the requirements of IBC Section 1104 COMPLETED Accessible Entrances are provided as per IBC Section 1105 COMPLETED Toilets, Bathing Fac., Sinks, Kit. and Drink. Fount. meet IBC Sec. 1109 COMPLETED Ventilation is provided as per IBC Section 1203 COMPLETED Page 2 of 3 Approval of plans does not constitute approval of variance from code --- Building Review (Continued) D ESCRIPTIO N CO MMEN TS STATUS Exterior Walls and Coverings comply with IBC Chapter 14 COMPLETED Building complies with IECC (IBC 1301)COMPLETED Roof and Roof Fire Classification comply with IBC Chapter 15 COMPLETED Structural Docs identify snow, wind, seismic and other loads per IBC Chp. 16 COMPLETED Structural Docs or plans identify Risk Category as per IBC Table 1604.5 COMPLETED Site Grading meets the requirements of IBC Section 1804.4 COMPLETED Foundation and Footings meet the requirements of IBC Chapter 1800 COMPLETED Concrete Documentation provided as per IBC Section 1901.5 COMPLETED Concrete Reinforcement identified on plans and designed by a licensed Engineer COMPLETED Anchorage to concrete is identified on plans as per IBC Section 1901.3 COMPLETED Masonry/reinforce. designed by licensed Eng.and meets the reqs. of IBC Chp 21 COMPLETED Struct. Steel designed by a licensed Eng. and meets the reqs. of IBC Chp. 22 COMPLETED Wood Fram. design. by lice. Eng. and meets. reqs. IBC Chp. 23 or Conv. Li-Frame COMPLETED Amount of Plumbing Fixtures meets the requirements of IBC Chapter 29 COMPLETED Exit Lighting and Exit Signs comply with IBC 1008 & 1013 COMPLETED Page 3 of 3 Approval of plans does not constitute approval of variance from code