HomeMy WebLinkAboutRESCHECK - 20-00402 - 651 S 2400 W Units 6101-6105 - Summerfield Townhome - 5 UnitsREScheck Software Version 4.6.5
Compliance Certificate
Project Kartchner townhomes 5 Plex
Energy Code:2015 IECC
Location:Idaho Falls, Idaho
Construction Type:Single-family
Project Type:New Construction
Conditioned Floor Area:7,323 ft2
Glazing Area 9%
Climate Zone:6 (7918 HDD)
Permit Date:
Construction Site:Owner/Agent:
Sprinter Heating & Hydronics
Designer/Contractor:
Mechanical Compliance Solutions
Mechanical Compliance Solutions
4181 Aschli lane
Idaho Falls, ID 83406
208-881-3243
1sgmiller@cableone.net
Permit Number:
Compliance: Passes using UA trade-off
0.5% Better Than Code Maximum UA:786 Your UA:782
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Wall 1: Wood Frame, 16" o.c.700 21.0 0.0 0.057 40
Wall 2: Wood Frame, 16" o.c.1,890 21.0 0.0 0.057 83
Door 1: Solid 105 0.140 15
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 325 0.320 104
Wall 3: Wood Frame, 16" o.c.700 21.0 0.0 0.057 40
Wall 4: Wood Frame, 16" o.c.1,890 21.0 0.0 0.057 93
Door 1: Solid 105 0.140 15
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 160 0.320 51
Floor 1: All-Wood Joist/Truss:Over Outside Air 1,555 38.0 0.0 0.026 40
Floor 2: Slab-On-Grade:Unheated
Insulation depth: 5.0'
262 16.7 0.648 169
Floor 3: Slab-On-Grade:Unheated
Insulation depth: 3.1'
16 10.2 0.699 11
Ceiling 1: Flat Ceiling or Scissor Truss 4,635 50.0 0.0 0.026 121
Project Title: Kartchner townhomes 5 Plex
Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Kartchner townhomes 5 Plex.rck Page 1 of 2
05/10/20Report date:
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Notes:
Job Number: Kartchner 3 Plex
INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE
VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID.
Project Title: Kartchner townhomes 5 Plex
Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Kartchner townhomes 5 Plex.rck Page 2 of 2
05/10/20Report date: