HomeMy WebLinkAboutTRUSS SPECS - 20-00398 - 2143 W 690 S - Summerfield - New SFRJob
20-055152T
Truss
A1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:15:40 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-YI?WAx_fdkgAyzGGopVQTwLXgtZNLbghP8As?uzKonn
Scale = 1:70.1
T2 T2
B1
W1
W2
W3
W4
W2
W3
W4T1 T1
B1B2B2
ST13
ST14
ST11
ST12
ST9
ST10
ST7
ST8
ST6
ST4
ST5
ST3ST2
ST1
ST13
ST14
ST11
ST12
ST9
ST10
ST7
ST8
ST6
ST4
ST5
ST3 ST2
ST1
A B
C
D
E
F
G
H I
L K J
BE
BF BG
BH
BI BJ BK BL
5x6
5x6
5x8
2x4
5x8
3x4
5x8
4x5
5x8
3x4
5x8
5x6
10
-
4
-
3
10
-
9
-
1
5
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [C:0-4-0,0-3-0], [G:0-4-0,0-3-0], [H:0-1-11,Edge], [J:0-2-0,0-2-0], [J:0-4-0,0-3-0], [K:0-4-0,0-3-4], [L:0-4-0,0-3-0], [L:0-1-8,0-0-3]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.62
0.68
0.69
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.39
-0.56
0.16
0.13
(loc)
J-K
J-K
H
K
l/defl
>999
>851
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 303 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-9-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-11-6 oc bracing.
WEBS 1 Row at midpt F-K, D-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2046/0-5-8 (min. 0-2-3), H=2046/0-5-8 (min. 0-2-3)
Max Horz B=194(LC 11)
Max UpliftB=-354(LC 12), H=-354(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-BE=-3665/1152, C-BE=-3556/1170, C-D=-3267/1107, D-BF=-2293/892, E-BF=-2155/903,
E-BG=-2155/903, F-BG=-2293/892, F-G=-3267/1107, G-BH=-3556/1170, H-BH=-3665/1152
BOT CHORD B-L=-900/3150, L-BI=-652/2567, BI-BJ=-652/2567, K-BJ=-652/2567, K-BK=-657/2567,
BK-BL=-657/2567, J-BL=-657/2567, H-J=-906/3150
WEBS E-K=-499/1418, F-K=-927/426, F-J=-130/580, G-J=-488/281, D-K=-927/426, D-L=-130/580,
C-L=-488/281
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=2ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Corner(3) -1-0-13 to 1-11-3, Exterior(2) 1-11-3 to 20-0-0, Corner(3) 20-0-0 to 23-0-0,
Exterior(2) 23-0-0 to 41-0-13 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=354,
H=354.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-055152T
Truss
A2
Truss Type
Common
Qty
6
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:15:43 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-ztgfoz0Xwf3kpQ_rUy275Yz2w4b4Y1M856OWcDzKonk
Scale = 1:65.5
T2 T2
B1
W1 W2
W3
W4
W2
W3
W4T1 T1
B1B2B2AB
C
D
E
F
G
H I
L K J
M
N O
P
Q R S T
5x6
5x6
5x8 5x8
3x4
5x8
5x8
3x4
5x8
5x6
10
-
4
-
3
10
-
9
-
1
5
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [C:0-4-0,0-3-0], [G:0-4-0,0-3-0], [H:0-1-11,Edge], [J:0-4-0,0-3-0], [K:0-4-0,0-3-4], [L:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.62
0.68
0.37
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.39
-0.56
0.16
0.12
(loc)
J-K
J-K
H
K
l/defl
>999
>851
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 188 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-9-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 9-7-8 oc bracing.
WEBS 1 Row at midpt F-K, D-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2046/0-5-8 (min. 0-2-3), H=2046/0-5-8 (min. 0-2-3)
Max Horz B=-194(LC 10)
Max UpliftB=-354(LC 12), H=-354(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-M=-3665/613, C-M=-3556/636, C-D=-3267/604, D-N=-2293/503, E-N=-2155/514,
E-O=-2155/514, F-O=-2293/503, F-G=-3267/604, G-P=-3556/636, H-P=-3665/613
BOT CHORD B-L=-466/3150, L-Q=-315/2567, Q-R=-315/2567, K-R=-315/2567, K-S=-326/2567,
S-T=-326/2567, J-T=-326/2567, H-J=-477/3150
WEBS E-K=-269/1418, F-K=-927/257, F-J=-49/580, G-J=-488/182, D-K=-927/257, D-L=-50/580,
C-L=-488/182
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 20-0-0, Exterior(2) 20-0-0 to 23-0-0,
Interior(1) 23-0-0 to 41-0-13 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=354,
H=354.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-055152T
Truss
A3
Truss Type
Common
Qty
9
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:15:46 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-NSMoQ?3PDaRJgujQ94cqjBbYOHcolO0an4dACYzKonh
Scale = 1:64.9
T2 T2
B1
W1 W2
W3
W4
W2
W3
W4T1 T3
B1B2B2AB
C
D
E
F
G
H
K J I
L
M N
O
P Q R S
5x6
5x6
5x8 5x8
3x4
5x8
5x8
3x4
5x8
5x6
10
-
4
-
3
10
-
9
-
1
5
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [C:0-4-0,0-3-4], [G:0-4-0,0-3-4], [H:0-1-11,Edge], [I:0-4-0,0-3-0], [J:0-4-0,0-3-4], [K:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.67
0.68
0.38
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.39
-0.56
0.16
0.13
(loc)
J-K
J-K
H
J
l/defl
>999
>848
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 187 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W4: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-7-10 oc purlins.
BOT CHORD Rigid ceiling directly applied or 9-2-11 oc bracing.
WEBS 1 Row at midpt F-J, D-J
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=2048/0-5-8 (min. 0-2-3), H=1936/0-5-8 (min. 0-2-1)
Max Horz B=193(LC 11)
Max UpliftB=-355(LC 12), H=-301(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-L=-3669/614, C-L=-3560/637, C-D=-3271/605, D-M=-2296/503, E-M=-2159/515,
E-N=-2158/520, F-N=-2296/508, F-G=-3282/627, G-O=-3566/665, H-O=-3658/651
BOT CHORD B-K=-494/3153, K-P=-344/2570, P-Q=-344/2570, J-Q=-344/2570, J-R=-341/2574,
R-S=-341/2574, I-S=-341/2574, H-I=-510/3169
WEBS E-J=-274/1421, F-J=-932/258, F-I=-68/590, G-I=-497/198, D-J=-927/257, D-K=-50/580,
C-K=-488/182
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 20-0-0, Exterior(2) 20-0-0 to 23-0-0,
Interior(1) 23-0-0 to 39-9-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=355,
H=301.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-055152T
Truss
A4
Truss Type
Common
Qty
8
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:15:49 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-n11w305IVVpuXLS?qC9XLpD4HVixyhW0T2sqptzKone
Scale = 1:64.9
T2 T3
B1
W7
W5
W3
W1
W2
W4
W6 W8
T1 T4
B4B3B2AB
C
D
E
F
G
H
L K J I
M
N O
P
Q R S
5x6
5x8
3x6
5x8
5x8
3x4
5x8
3x4
5x6 1.5x4
3x6
10
-
4
-
3
10
-
9
-
1
5
6.00 12
Plate Offsets (X,Y)-- [C:0-4-0,0-3-0], [G:0-4-0,0-3-0], [H:0-2-8,0-1-8], [J:0-3-0,0-3-0], [K:0-4-0,0-3-0], [L:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.56
0.40
0.59
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.17
-0.31
0.02
0.04
(loc)
B-L
B-L
H
H-I
l/defl
>999
>729
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 193 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W7,W4,W8: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-2-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt D-K, E-K, F-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=620/0-5-8 (min. 0-1-8), K=2695/0-5-8 (min. 0-2-14), H=685/Mechanical
Max Horz B=193(LC 11)
Max UpliftB=-126(LC 12), K=-432(LC 12), H=-101(LC 12)
Max GravB=777(LC 21), K=2695(LC 1), H=794(LC 22)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-M=-936/219, C-M=-829/249, C-D=-520/328, D-N=-46/883, E-N=-32/996, E-O=-4/829,
F-O=-18/715, F-G=-507/225, G-P=-1164/181, H-P=-1280/167
BOT CHORD B-L=-195/734, L-Q=-386/150, Q-R=-386/150, K-R=-386/150, K-S=-185/345, J-S=-185/345,
I-J=-83/1034, H-I=-82/1037
WEBS C-L=-544/193, D-L=-64/612, D-K=-920/258, E-K=-1232/187, F-K=-1019/249, F-J=-31/489,
G-J=-784/209
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 20-0-0, Exterior(2) 20-0-0 to 23-0-0,
Interior(1) 23-0-0 to 39-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=126,
K=432, H=101.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-055152T
Truss
A5
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:15:53 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-goHRuO8pZjJK0zlm32ETVfOmG63tuVVcOfq2yezKona
Scale = 1:73.9
T2 T3
B1
W7
W5
W3
W1
W2
W4
W6 W8
T1 T4
B4B3B2
ST15
ST16
ST13
ST14
ST11
ST12
ST9
ST10
ST7
ST8
ST6
ST4
ST5
ST3ST2
ST1
ST17
ST18
ST19
ST20
ST21
ST22
ST23 ST24
ST25
ST26
ST27
ST3
ST2
ST1
A B
C
D
E
F
G
H
L K J I
BH
BI BJ
BK
BL BM BN
5x6
10x16
5x8
3x6
5x8
2x4
5x8
3x4
5x8
3x4
5x6
3x6
10
-
4
-
3
10
-
9
-
1
5
6.00 12
Plate Offsets (X,Y)-- [C:0-4-0,0-3-0], [E:0-8-0,0-1-12], [G:0-4-0,0-3-0], [H:0-2-8,0-1-8], [J:0-3-0,0-3-0], [K:0-4-0,0-3-0], [L:0-4-0,0-3-0], [L:0-1-8,0-0-3], [AX:0-1-15,0-0-12],
[BA:0-1-15,0-0-12]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.56
0.40
0.59
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.17
-0.31
0.02
0.04
(loc)
B-L
B-L
H
H-I
l/defl
>999
>729
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 320 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
W7,W4,W8: 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std *Except*
ST15,ST13: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F
1.6E
BRACING-
TOP CHORD Sheathed or 5-2-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt D-K, E-K, F-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=620/0-5-8 (min. 0-1-8), K=2695/0-5-8 (min. 0-2-14), H=685/Mechanical
Max Horz B=193(LC 11)
Max UpliftB=-126(LC 12), K=-432(LC 12), H=-101(LC 12)
Max GravB=777(LC 21), K=2695(LC 1), H=794(LC 22)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-BH=-936/219, C-BH=-829/249, C-D=-520/328, D-BI=-46/883, E-BI=-32/996, E-BJ=-4/829,
F-BJ=-18/715, F-G=-507/225, G-BK=-1164/181, H-BK=-1280/167
BOT CHORD B-L=-195/734, L-BL=-386/150, BL-BM=-386/150, K-BM=-386/150, K-BN=-185/345,
J-BN=-185/345, I-J=-83/1034, H-I=-82/1037
WEBS C-L=-544/193, D-L=-64/612, D-K=-920/258, E-K=-1232/187, F-K=-1019/249, F-J=-31/489,
G-J=-784/209
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 20-0-0, Exterior(2) 20-0-0 to 23-0-0,
Interior(1) 23-0-0 to 39-11-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=126,
K=432, H=101.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-055152T
Truss
B1
Truss Type
HIP GIRDER
Qty
1
Ply
2
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:15:56 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-4NzaXPAhsehutQULkAnA7I0ECJ0p5ng24d2iZzzKonX
Scale = 1:65.0
0-
1
-
5
0-
1
-
5
A B
C
D E F G H
I
J K
P O N M L
Q R
S T U V W X Y Z AA AB
5x8
4x12
8x12 MT20HS4x8
1.5x4
3x6 5x8
2x4 8x12 MT20HS
3x6
4x8
1.5x4
5x8
4x12
Special
Special
Special Special Special Special Special
Special
Special Special
Special
Special
4-
2
-
1
4
4-
4
-
3
4-
9
-
1
5
4-
2
-
1
4
6.00 12
Plate Offsets (X,Y)-- [B:0-3-8,0-1-15], [D:0-4-0,0-1-15], [F:0-4-0,0-3-0], [H:0-4-0,0-1-15], [J:0-3-8,0-1-15], [M:0-6-0,0-4-8], [O:0-6-0,0-4-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.71
0.76
0.88
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.57
-0.79
0.19
0.28
(loc)
M-N
M-N
J
N
l/defl
>789
>574
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT20HS
Weight: 415 lb FT = 20%
GRIP
220/195
165/146
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-1-11 oc purlins, except
2-0-0 oc purlins (3-6-8 max.): D-H.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)B=4878/0-3-8 (min. 0-2-10), J=4878/0-3-8 (min. 0-2-10)
Max Horz B=82(LC 7)
Max UpliftB=-948(LC 8), J=-948(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-C=-10102/1935, C-D=-9899/1900, D-Q=-8704/1707, E-Q=-8706/1707, E-F=-12266/2369,
F-G=-12266/2369, G-R=-8706/1707, H-R=-8704/1707, H-I=-9899/1900, I-J=-10102/1935
BOT CHORD B-P=-1655/8921, P-S=-2218/12266, S-T=-2218/12266, O-T=-2218/12266, O-U=-2422/13402,
U-V=-2422/13402, V-W=-2422/13402, N-W=-2422/13402, N-X=-2422/13402, X-Y=-2422/13402,
Y-Z=-2422/13402, M-Z=-2422/13402, M-AA=-2218/12266, AA-AB=-2218/12266,
L-AB=-2218/12266, J-L=-1655/8921
WEBS C-P=-297/257, D-P=-732/3975, E-P=-4433/807, E-O=-311/1976, F-O=-1478/248,
F-N=-151/1106, F-M=-1478/248, G-M=-311/1976, G-L=-4433/807, H-L=-732/3975,
I-L=-297/257
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate
grip DOL=1.33
5) Provide adequate drainage to prevent water ponding.
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=948,
J=948.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
Continued on page 2
Job
20-055152T
Truss
B1
Truss Type
HIP GIRDER
Qty
1
Ply
2
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:15:57 2020 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-YZWyklBJdyqlUa3XIuIPfVZPyjL1qEwCJHoF5PzKonW
NOTES-
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1105 lb down and 267 lb up at 8-0-0, 365 lb down and 77 lb up at 10-0-12
, 365 lb down and 77 lb up at 12-0-12, 365 lb down and 77 lb up at 14-0-12, 365 lb down and 77 lb up at 16-0-12, 365 lb down and 77 lb up at 18-0-12, 365 lb down and 77
lb up at 19-11-4, 365 lb down and 77 lb up at 21-11-4, 365 lb down and 77 lb up at 23-11-4, 365 lb down and 77 lb up at 25-11-4, and 365 lb down and 77 lb up at 27-11-4,
and 1105 lb down and 267 lb up at 29-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, D-H=-84, H-K=-84, B-J=-14
Concentrated Loads (lb)
Vert: P=-1105(F) L=-1105(F) S=-365(F) T=-365(F) U=-365(F) V=-365(F) W=-365(F) X=-365(F) Y=-365(F) Z=-365(F) AA=-365(F) AB=-365(F)
Job
20-055152T
Truss
B2
Truss Type
Hip
Qty
1
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:15:59 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-Vyei9RDZ9Z4TkuDwQJLtkwepqX37I7PUmbHMAIzKonU
Scale = 1:65.0
0-
1
-
1
1
0-
1
-
1
1
A B
C
D E F G
H
I J
M L K
N
O
P Q R S
T
U
5x6 5x8
5x6
7x10
1.5x4
3x4
5x8 7x10
1.5x4
5x6
5x6
5-
2
-
8
5-
4
-
3
5-
9
-
1
5
5-
2
-
8
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [F:0-4-0,0-3-0], [I:0-1-11,Edge], [K:0-4-12,Edge], [L:0-4-0,0-3-0], [M:0-4-12,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.50
0.60
0.94
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.34
-0.49
0.18
0.15
(loc)
L
L-M
I
L
l/defl
>999
>928
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 172 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std *Except*
: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 3-3-4 oc purlins, except
2-0-0 oc purlins (3-3-7 max.): D-G.
BOT CHORD Rigid ceiling directly applied or 8-5-9 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=1949/0-3-8 (min. 0-2-1), I=1949/0-3-8 (min. 0-2-1)
Max Horz B=101(LC 11)
Max UpliftB=-337(LC 12), I=-337(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-N=-3552/750, C-N=-3493/766, C-O=-3146/651, D-O=-3046/668, D-P=-2736/646,
P-Q=-2738/645, E-Q=-2740/645, E-F=-3521/779, F-R=-2740/645, R-S=-2738/645,
G-S=-2736/646, G-T=-3046/668, H-T=-3146/651, H-U=-3493/766, I-U=-3552/750
BOT CHORD B-M=-612/3095, L-M=-602/3486, K-L=-606/3486, I-K=-619/3095
WEBS C-M=-404/190, D-M=-135/927, E-M=-1114/244, F-K=-1114/244, G-K=-135/927, H-K=-404/190
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 10-0-0, Exterior(2) 10-0-0 to 14-2-15,
Interior(1) 14-2-15 to 28-0-0, Exterior(2) 28-0-0 to 32-2-15, Interior(1) 32-2-15 to 39-0-13 zone; cantilever left and right exposed ; end
vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=337,
I=337.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
LOAD CASE(S) Standard
Job
20-055152T
Truss
B3
Truss Type
Hip Girder
Qty
1
Ply
2
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:02 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-vXKrnTFSRUS2bLxU5RuaMZGHLk1qVV8xSZV0ndzKonR
Scale = 1:63.3
0-
1
-
1
1
0-
1
-
1
1
A
B
C
D E F G
H
I
J
R Q P O N M L K
S T
U V W X Y Z AA AB
4x12
5x8 5x6
5x6
7x10
3x6
2x4 8x12
3x8
3x8
2x4 4x5
3x6
7x10
3x4
4x5
3x4
2x4
Special
Special
Special Special Special Special Special
Special
Special
6-
1
-
0
6-
2
-
1
1
6-
1
-
0
6.00 12
Plate Offsets (X,Y)-- [A:Edge,0-3-14], [D:0-4-0,0-1-15], [J:0-3-0,0-2-9], [M:0-4-12,0-4-8], [P:0-4-12,0-4-8], [Q:0-3-8,0-4-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.67
0.85
0.88
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.39
-0.52
0.15
0.15
(loc)
O-P
O-P
J
O-P
l/defl
>999
>863
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 465 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x6 DF 1800F 1.6E or 2x6 DF SS
WEBS 2x4 DF Stud/Std *Except*
: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 3-1-13 oc purlins, except
2-0-0 oc purlins (4-6-12 max.): D-G.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)A=7268/0-3-8 (req. 0-3-14), J=3424/0-3-8 (min. 0-1-13)
Max Horz A=-106(LC 6)
Max UpliftA=-1062(LC 8), J=-509(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-13802/2002, B-C=-11785/1740, C-D=-9762/1479, D-S=-8722/1353, E-S=-8727/1353,
E-F=-7532/1194, F-T=-5772/939, G-T=-5767/940, G-H=-6481/1020, H-I=-6844/1045,
I-J=-7073/1052
BOT CHORD A-U=-1750/12263, U-V=-1750/12263, R-V=-1750/12263, R-W=-1750/12263, W-X=-1750/12263,
Q-X=-1750/12263, Q-Y=-1459/10498, Y-Z=-1459/10498, P-Z=-1459/10498, P-AA=-1211/8952,
AA-AB=-1211/8952, O-AB=-1211/8952, N-O=-1211/8952, M-N=-1011/7532, L-M=-837/6061,
K-L=-901/6241, J-K=-901/6241
WEBS B-R=-191/1529, B-Q=-1974/324, C-Q=-321/2430, C-P=-2502/408, D-P=-563/3977,
E-P=-634/65, E-O=-145/1393, E-N=-2334/372, F-N=-199/1723, F-M=-2907/399,
G-M=-359/2519, H-M=-458/115, I-L=-306/77
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-4-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=5ft; Cat. II;
Exp C; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate
grip DOL=1.33
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) WARNING: Required bearing size at joint(s) A greater than input bearing size.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=1062,
J=509.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
Continued on page 2
Job
20-055152T
Truss
B3
Truss Type
Hip Girder
Qty
1
Ply
2
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:03 2020 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-NjuD?pG4CoavCVWhf8PpvmoS58N3EyO4hDFZJ3zKonQ
NOTES-
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 756 lb down and 128 lb up at 1-0-12, 780 lb down and 115 lb up at 2-6-12
, 780 lb down and 115 lb up at 4-6-12, 780 lb down and 115 lb up at 6-6-12, 780 lb down and 115 lb up at 8-6-12, 780 lb down and 115 lb up at 10-6-12, 780 lb down and
115 lb up at 12-6-12, and 780 lb down and 115 lb up at 14-6-12, and 780 lb down and 115 lb up at 16-6-12 on bottom chord. The design/selection of such connection
device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, D-G=-84, G-J=-84, A-J=-14
Concentrated Loads (lb)
Vert: O=-780(B) U=-756(B) V=-780(B) W=-780(B) X=-780(B) Y=-780(B) Z=-780(B) AA=-780(B) AB=-780(B)
Job
20-055152T
Truss
C1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:05 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-J6?zQUHKkPqdSpg3mZSH_Bus7x9pi0dN9XkgNyzKonO
Scale = 1:40.2
A
B
C
D
E
F
H GABACADAEAFAG AH AI AJ
3x6
4x5
2x4
5x6 3x4 3x6 Special Special Special
Special
Special Special Special Special Special Special
5-
8
-
1
1
6-
2
-
7
6.00 12
Plate Offsets (X,Y)-- [C:0-2-0,0-0-4], [G:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.38
0.39
0.26
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.08
-0.13
0.04
0.04
(loc)
A-H
A-H
E
A-H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 122 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-7-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)A=1036/0-3-8 (min. 0-1-8), E=1144/0-3-8 (min. 0-1-8)
Max Horz A=-108(LC 6)
Max UpliftA=-161(LC 8), E=-213(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-1865/307, B-C=-1606/305, C-D=-1595/299, D-E=-1853/300
BOT CHORD A-AB=-200/1580, AB-AC=-200/1580, AC-AD=-200/1580, H-AD=-200/1580, H-AE=-57/1028,
AE-AF=-57/1028, AF-AG=-57/1028, G-AG=-57/1028, G-AH=-191/1566, AH-AI=-191/1566,
AI-AJ=-191/1566, E-AJ=-191/1566
WEBS C-G=-81/563, D-G=-438/157, C-H=-91/579, B-H=-446/161
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate
grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=161,
E=213.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 5 lb up at 1-5-4, 5 lb up at 3-5-4, 5
lb up at 5-5-4, 5 lb up at 7-5-4, 5 lb up at 9-5-4, 5 lb up at 11-5-4, 5 lb up at 13-5-4, 5 lb up at 15-5-4, and 5 lb up at 17-5-4, and 5 lb
up at 19-5-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Continued on page 2
Job
20-055152T
Truss
C1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:05 2020 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-J6?zQUHKkPqdSpg3mZSH_Bus7x9pi0dN9XkgNyzKonO
LOAD CASE(S) Standard
Uniform Loads (plf)
Vert: A-C=-84, C-F=-84, A-E=-14
Job
20-055152T
Truss
C2
Truss Type
Common
Qty
2
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:12 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-cSwdutNj5ZidouiPgX4xmgg3wmZ_rAMPm7wY72zKonH
Scale = 1:34.7
A
B
C
D
E
H G F
I
J K
L
3x6
4x5
3x6 3x4 3x4
1.5x4
3x4
1.5x4
5-
8
-
1
1
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.34
0.35
0.26
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.08
-0.13
0.04
0.04
(loc)
E-F
E-F
E
E-F
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 87 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-7-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)A=1039/0-3-8 (min. 0-1-8), E=1039/0-3-8 (min. 0-1-8)
Max Horz A=99(LC 11)
Max UpliftA=-162(LC 12), E=-162(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-I=-1871/363, B-I=-1691/374, B-J=-1612/352, C-J=-1500/371, C-K=-1500/371,
D-K=-1612/352, D-L=-1691/374, E-L=-1871/363
BOT CHORD A-H=-270/1585, G-H=-113/1034, F-G=-113/1034, E-F=-270/1585
WEBS C-F=-104/579, D-F=-446/176, C-H=-104/579, B-H=-446/176
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 10-9-0, Exterior(2) 10-9-0 to 13-9-0,
Interior(1) 13-9-0 to 21-4-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=162,
E=162.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-055152T
Truss
CJ1
Truss Type
Diagonal Hip Girder
Qty
2
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:14 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-Zr2NIZO_cAzL1Bsooy6Pr5mFGaFgJzOiDQPfCwzKonF
Scale = 1:26.7
A
B
C
D E
H G
F
I
J
K L
4x5
3x6 3x4
3x4
1.5x4
Special
Special
Special
Special
Special
Special
Special
Special
Special
Special
Special
Special
4-
3
-
1
4
4-
9
-
7
4.24 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.99
0.34
0.67
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.04
-0.08
0.02
0.02
(loc)
G-H
G-H
G
H
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 48 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-9-11 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)G=760/Mechanical, B=774/0-4-9 (min. 0-1-8)
Max Horz B=163(LC 5)
Max UpliftG=-170(LC 5), B=-183(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-I=-1246/212, C-I=-1101/227, D-G=-298/114
BOT CHORD B-K=-268/1104, H-K=-268/1104, H-L=-268/1104, G-L=-268/1104
WEBS C-H=0/296, C-G=-1116/255
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate
grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) G=170,
B=183.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 23 lb up at 2-9-8, 23 lb up at 2-9-8,
23 lb down and 68 lb up at 5-7-7, 23 lb down and 68 lb up at 5-7-7, and 113 lb down and 108 lb up at 8-5-6, and 113 lb down and 108
lb up at 8-5-6 on top chord, and at 2-9-8, at 2-9-8, 16 lb down at 5-7-7, 16 lb down at 5-7-7, and 50 lb down at 8-5-6, and 50 lb down
at 8-5-6 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, D-E=-14, B-F=-14
Concentrated Loads (lb)
Vert: C=-46(F=-23, B=-23) H=-13(F=-7, B=-7) J=-225(F=-113, B=-113) L=-41(F=-21, B=-21)
Job
20-055152T
Truss
D1
Truss Type
Common
Qty
1
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:17 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-zPkWxbRsv5LwufbNT5f6TjO_xnLHWTa8vOeJpFzKonC
Scale: 1/2"=1'
A
B
C
D
E
F
G
H
I
N M L K J
O
P Q
R
4x5
3x4 3x4
3-
8
-
3
4-
1
-
1
5
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.02
0.06
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
-0.00
0.00
(loc)
I
I
H
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 55 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 13-4-0.
(lb) - Max Horz B=71(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) B, H, M, N, K, J
Max Grav All reactions 250 lb or less at joint(s) B, H, L, M, N, K, J
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=2ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Corner(3) -1-0-13 to 1-11-3, Exterior(2) 1-11-3 to 6-8-0, Corner(3) 6-8-0 to 9-8-0,
Exterior(2) 9-8-0 to 14-4-13 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, H, M, N, K, J.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-055152T
Truss
D2
Truss Type
Common
Qty
3
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:19 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-vorGMHS6Ribd7ylmbWiaY8TDAbxw_NQRNi7Qt8zKonA
Scale = 1:23.0
A
B
C
D
E
F
G H
I
5x6
3x6 3x6 1.5x4
3-
8
-
3
4-
1
-
1
5
6.00 12
Plate Offsets (X,Y)-- [B:0-2-9,0-1-8], [D:0-2-9,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.53
0.40
0.11
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.08
-0.12
0.01
0.04
(loc)
D-E
D-E
D
D-E
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 44 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 5-8-12 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)D=625/0-5-8 (min. 0-1-8), B=745/0-5-8 (min. 0-1-8)
Max Horz B=70(LC 11)
Max UpliftD=-95(LC 12), B=-153(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-F=-906/177, F-G=-779/188, C-G=-772/200, C-H=-769/215, H-I=-779/201, D-I=-903/201
BOT CHORD B-E=-103/690, D-E=-103/690
WEBS C-E=0/261
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 6-8-0, Exterior(2) 6-8-0 to 9-8-0,
Interior(1) 9-8-0 to 13-1-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) D except (jt=lb)
B=153.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-055152T
Truss
J1
Truss Type
JACK-CLOSED
Qty
12
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:22 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-KNXP_IU?kdzC_QTKGeFHAn5gFoyFBlpt3gL4UTzKon7
Scale = 1:24.8
A
B
C
D
H
I
1.5x4
1.5x4 3x6
4-
4
-
3
4-
9
-
1
5
6.00 12
Plate Offsets (X,Y)-- [B:0-2-9,0-1-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-AS
0.74
0.49
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.21
-0.34
0.01
0.13
(loc)
D-G
D-G
B
D-G
l/defl
>441
>277
n/a
>748
L/d
360
240
n/a
240
PLATES
MT20
Weight: 30 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed, except end verticals.
BOT CHORD Rigid ceiling directly applied.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)D=379/Mechanical, B=480/0-3-8 (min. 0-1-8)
Max Horz B=162(LC 11)
Max UpliftD=-63(LC 12), B=-99(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD C-D=-291/213
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 7-10-4 zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip
DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) D, B.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum
sheetrock be applied directly to the bottom chord.
LOAD CASE(S) Standard
Job
20-055152T
Truss
J1A
Truss Type
Jack-Open
Qty
4
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:24 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-Gmf9P_WFGFDwEkdjN3HlFCA3fchsffJAW_qBYLzKon5
Scale = 1:19.0
A
B
E
C
D2x4
3-
4
-
0
3-
9
-
1
2
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.55
0.22
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.06
-0.10
-0.00
0.00
(loc)
B-D
B-D
C
B
l/defl
>999
>702
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 19 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 5-11-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)C=231/Mechanical, B=395/0-3-8 (min. 0-1-8), D=40/Mechanical
Max Horz B=120(LC 12)
Max UpliftC=-87(LC 12), B=-74(LC 12)
Max GravC=231(LC 1), B=395(LC 1), D=98(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 5-10-15 zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip
DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) C, B.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-055152T
Truss
J1B
Truss Type
Jack-Open
Qty
4
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:26 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-C8nvqgXVosTeT1n6VUKDLdFUlPPP7ZpT_IJHdEzKon3
Scale = 1:14.2
A
B
E
F
C
D
2x4
2-
4
-
0
2-
9
-
1
2
2-
4
-
0
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.19
0.09
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.01
-0.02
-0.00
0.00
(loc)
B-D
B-D
C
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 13 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 3-11-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)C=142/Mechanical, B=303/0-3-8 (min. 0-1-8), D=26/Mechanical
Max Horz B=88(LC 12)
Max UpliftC=-52(LC 12), B=-70(LC 12)
Max GravC=142(LC 1), B=303(LC 1), D=64(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 3-10-15 zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip
DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) C, B.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-055152T
Truss
J1C
Truss Type
Jack-Open
Qty
4
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:28 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-8XugEMZmJTjMiLxUcvMhQ2Ls8D6wbTImRcoOh6zKon1
Scale = 1:9.3
A
B
C
D2x4
1-
4
-
0
1-
9
-
1
2
1-
4
-
0
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.07
0.02
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.00
-0.00
-0.00
0.00
(loc)
B
B-D
C
B
l/defl
>999
>999
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 7 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 1-11-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)C=55/Mechanical, B=213/0-3-8 (min. 0-1-8), D=14/Mechanical
Max Horz B=57(LC 12)
Max UpliftC=-16(LC 9), B=-65(LC 12)
Max GravC=55(LC 1), B=213(LC 1), D=33(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) C, B.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-055152T
Truss
J2
Truss Type
Jack-Open
Qty
3
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:34 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-zhFxVPeWvJUVRGOez9T5fJbm_e6m?9eepYFiumzKomx
Scale = 1:20.7
A
B
C
D
E
1.5x4
2x4 1.5x4
3-
6
-
7
4-
0
-
3
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.62
0.25
0.07
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.07
-0.12
0.00
0.00
(loc)
B-D
B-D
B
l/defl
>999
>597
n/a
****
L/d
360
240
n/a
240
PLATES
MT20
Weight: 24 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=410/0-3-8 (min. 0-1-8), D=288/Mechanical
Max Horz B=125(LC 12)
Max UpliftB=-75(LC 12), D=-67(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) -1-0-13 to 1-11-3, Interior(1) 1-11-3 to 6-2-12 zone; cantilever left and right
exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip
DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, D.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-055152T
Truss
J3
Truss Type
Jack-Open
Qty
11
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:41 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-G1BazojvGTMWmLQ_t75kRnN4sSY27LWgQ7SaeszKomq
Scale = 1:6.9
A
B
C
D
2x4
0-
1
0
-
3
1-
3
-
1
5
6.00 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.07
0.01
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
0.00
0.00
0.00
(loc)
B
B
l/defl
>999
>999
n/a
L/d
360
240
n/a
PLATES
MT20
Weight: 5 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BRACING-
TOP CHORD Sheathed or 1-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=191/0-3-8 (min. 0-1-8), D=-4/Mechanical
Max Horz B=73(LC 12)
Max UpliftB=-131(LC 12), D=-4(LC 1)
Max GravB=191(LC 1), D=14(LC 3)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) D except (jt=lb)
B=131.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
20-055152T
Truss
LG1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER SF14B11 ATHENS B 3CEXT
Job Reference (optional)
8.330 s Jan 22 2020 MiTek Industries, Inc. Fri May 1 16:16:43 2020 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:o2JzxLaBl_ZuNw9ih9_LsCz9M_B-CQILOUlAn4cE0faN?Y7CXCSQBGCgbDszuRxhilzKomo
Scale = 1:73.6
T1 T1
B1
ST5
ST4
ST3
ST2
ST1
B1
ST4
ST3
ST2
ST1
A
B
C
D
E
F
G
H
I
J
K
T S R Q P O N M L
U
V W
X
3x4
4x5
3x4
5x6
12
-
2
-
1
0
13.42 12
Plate Offsets (X,Y)-- [P:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.08
0.07
0.14
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
n/a
n/a
0.01
(loc)
-
-
K
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 154 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E *Except*
ST2,ST1: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt F-P, E-Q, G-O
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 21-10-5.
(lb) - Max Horz A=-317(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) K, P, Q, S, O, M except A=-149(LC 10), R=-120(LC 12), T=-151(LC
12), N=-120(LC 12), L=-151(LC 12)
Max Grav All reactions 250 lb or less at joint(s) A, K, Q, R, S, O, N, M except P=251(LC 12), T=294(LC 17),
L=294(LC 18)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-289/272, J-K=-289/253
WEBS F-P=-257/205
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II;
Exp C; Enclosed; MWFRS (directional) and C-C Exterior(2) 0-3-15 to 3-3-15, Interior(1) 3-3-15 to 10-11-2, Exterior(2) 10-11-2 to 13-11-2,
Interior(1) 13-11-2 to 21-6-6 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) All plates are 1.5x4 MT20 unless otherwise indicated.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) K, P, Q, S, O, M
except (jt=lb) A=149, R=120, T=151, N=120, L=151.
8) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard