Loading...
HomeMy WebLinkAboutRESCHECK - 20-00321 - 651 S 2400 W Units 21101-21105 - Summerfield Townhomes - 5 UnitsREScheck Software Version 4.6.5 Compliance Certificate Project Kartchner townhomes 5 Plex Energy Code:2015 IECC Location:Idaho Falls, Idaho Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:7,323 ft2 Glazing Area 9% Climate Zone:6 (7918 HDD) Permit Date: Construction Site:Owner/Agent: Sprinter Heating & Hydronics Designer/Contractor: Mechanical Compliance Solutions Mechanical Compliance Solutions 4181 Aschli lane Idaho Falls, ID 83406 208-881-3243 1sgmiller@cableone.net Permit Number: Compliance: Passes using UA trade-off 0.5% Better Than Code Maximum UA:786 Your UA:782 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Wall 1: Wood Frame, 16" o.c.700 21.0 0.0 0.057 40 Wall 2: Wood Frame, 16" o.c.1,890 21.0 0.0 0.057 83 Door 1: Solid 105 0.140 15 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 325 0.320 104 Wall 3: Wood Frame, 16" o.c.700 21.0 0.0 0.057 40 Wall 4: Wood Frame, 16" o.c.1,890 21.0 0.0 0.057 93 Door 1: Solid 105 0.140 15 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 160 0.320 51 Floor 1: All-Wood Joist/Truss:Over Outside Air 1,555 38.0 0.0 0.026 40 Floor 2: Slab-On-Grade:Unheated Insulation depth: 5.0' 262 16.7 0.648 169 Floor 3: Slab-On-Grade:Unheated Insulation depth: 3.1' 16 10.2 0.699 11 Ceiling 1: Flat Ceiling or Scissor Truss 4,635 50.0 0.0 0.026 121 Project Title: Kartchner townhomes 5 Plex Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Kartchner townhomes 5 Plex.rck Page 1 of 2 05/10/20Report date: Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Notes: Job Number: Kartchner 3 Plex INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Project Title: Kartchner townhomes 5 Plex Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Kartchner townhomes 5 Plex.rck Page 2 of 2 05/10/20Report date: