FIRE ALARM INSPECTION AND TESTING REPORT
Testing performed in accordance with applicable NFPA 72 Standards / By NICET Certified Technicians
Building occupied as VC V Owner /Manager: Name & Number
Address of Building t4c&M-k 7 ,,J,- i V�rF3 J EL, _Tp g>-
Name of Tester 1 -�� 1'yDate of Inspection _/I!� ' /�,7 �n
Type of Inspection `�i� t'r A Notification of Testing
Control Panel Manufacturer & Model FC T
# of Zones: _ X SLC Loops: �_ NAC's - FACP: �_ FCPS:
System should be tested on Standby (battery power) for 30 min. prior to Battery Test.— Total NAC's:
Battery Inspection
FACP
Location
Battery Voltage 1 z—
Amp Hour (7—
Date
7 -Date on Battery
FACP Insnection
Key to Panel Available
Operating Instructions at Panel
Newest Record posted at Panel
circuit Breaker marked Red
circuit Breaker Panel:
Trouble Signal with AC Power
System operates satisfactory on
standby power at max load
All signals operate on AC powe
All LED's Illuminate
Name of Monitoring Company:_
Communication Verified:
Equipment Tested
FCPSl
Yes No N/A
All circuits checked for
electrical supervision
All functions and buttons
work properly
Does Alarm system meet
audibility standards
Control Panel checks made per
manufacturer's instruction
All interfaced equipment operates
(Elevators, Fans, Dampers)
Account #
Yes
No
N/A
Annunciators
Dialer, Communicator
Horns, Strobes. Bells,
Chimes, Speakers, Eta
N/A -�–
Type of Equipment
# of Units
Tested
Satisfactory: Satisfactory: N/A # of Units
Yes No in Bldg.
FCPS Power Booster
Annunciators
Dialer, Communicator
Horns, Strobes. Bells,
Chimes, Speakers, Eta
Smoke Detectors
Heat Detectors
Duct Detectors
Pull Stations
/
Flow Switches
%
Tam er Switches
Low/High Air Switches
yIi
Antifreeze Tamper
Ansul S stem
Temp Sensor
Problems Found:
Corrections Made:
Interfaced # of Units Satisfactory: Satisfactory: N/A # of Units
Equipment Tested Yes No in Bldg.
Ventilation Controls
Elev. Recall Prima
Elev. Recall Sec
Elev. Recall Shunt
Access Control Door
Release Failsafe
Auto Release
Door Holders
Halon System
Smoke Control
PIV Valve
Beam Detector
CO Detector
This is to certify that this Fire Alarm has been properly Tested and Inspected for liability to cover the items listed in this report, according to
Manufacturers Recommen4ation. (1
Signature of Fire Marshal:
Signature of Owner or representative: —
Signature of Certified Tester: �-
Agency: Omni Security Systems, Inc. • P
Date:
Date:
_ Date: 1 Z
Box 309 • Rigby, ID 83442 • Office 208-745-1020 • Fax: 208-745-1564