Loading...
HomeMy WebLinkAboutFA TESTING REPORT -20-00298 - 510 N 2nd E - DMV Remodel - Fire Alarm additionWA C J �m MEMBER RITY SYSTEMS INC. ' FIRE ALARM INSPECTION AND TESTING REPORT Testing performed in accordance with applicable NFPA 72 Standards / By NICET Certified Technicians Building occupied as VC V Owner /Manager: Name & Number Address of Building t4c&M-k 7 ,,J,- i V�rF3 J EL, _Tp g>- Name of Tester 1 -�� 1'yDate of Inspection _/I!� ' /�,7 �n Type of Inspection `�i� t'r A Notification of Testing Control Panel Manufacturer & Model FC T # of Zones: _ X SLC Loops: �_ NAC's - FACP: �_ FCPS: System should be tested on Standby (battery power) for 30 min. prior to Battery Test.— Total NAC's: Battery Inspection FACP Location Battery Voltage 1 z— Amp Hour (7— Date 7 -Date on Battery FACP Insnection Key to Panel Available Operating Instructions at Panel Newest Record posted at Panel circuit Breaker marked Red circuit Breaker Panel: Trouble Signal with AC Power System operates satisfactory on standby power at max load All signals operate on AC powe All LED's Illuminate Name of Monitoring Company:_ Communication Verified: Equipment Tested FCPSl Yes No N/A All circuits checked for electrical supervision All functions and buttons work properly Does Alarm system meet audibility standards Control Panel checks made per manufacturer's instruction All interfaced equipment operates (Elevators, Fans, Dampers) Account # Yes No N/A Annunciators Dialer, Communicator Horns, Strobes. Bells, Chimes, Speakers, Eta N/A -�– Type of Equipment # of Units Tested Satisfactory: Satisfactory: N/A # of Units Yes No in Bldg. FCPS Power Booster Annunciators Dialer, Communicator Horns, Strobes. Bells, Chimes, Speakers, Eta Smoke Detectors Heat Detectors Duct Detectors Pull Stations / Flow Switches % Tam er Switches Low/High Air Switches yIi Antifreeze Tamper Ansul S stem Temp Sensor Problems Found: Corrections Made: Interfaced # of Units Satisfactory: Satisfactory: N/A # of Units Equipment Tested Yes No in Bldg. Ventilation Controls Elev. Recall Prima Elev. Recall Sec Elev. Recall Shunt Access Control Door Release Failsafe Auto Release Door Holders Halon System Smoke Control PIV Valve Beam Detector CO Detector This is to certify that this Fire Alarm has been properly Tested and Inspected for liability to cover the items listed in this report, according to Manufacturers Recommen4ation. (1 Signature of Fire Marshal: Signature of Owner or representative: — Signature of Certified Tester: �- Agency: Omni Security Systems, Inc. • P Date: Date: _ Date: 1 Z Box 309 • Rigby, ID 83442 • Office 208-745-1020 • Fax: 208-745-1564