HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00012 - 2280 W 960 S - New SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 05/12/2020 8:53 am
Permit Details Permit Number: 11-00012
2280 W 960 S - New SFR
2280 W 960 S
New Single Family Residence
Permit Issued Date: 08/21/2014
Permit Inspection Statistics
22Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 77.27%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building
02/04/2011PassTed DyeResidential Footing Inspection
Overlaps look good
Rebar suspended in the air
OK to pour
Inspector Comments:
02/07/2011PassTed DyeFoundation Inspection
Ufer in west wall in south corner.
Over laps OK
Instructor to put hot water in bottom of form to melt snow.
Inspector Comments:
03/07/2011FailTed DyeResidential Framing/Structure Inspection
Sheeting on east wall in front bedroom is not pulled up tight against stud. Same
as above in master bath east wall. POST PERMIT
Inspector Comments:
03/15/2011FailTed DyeResidential Framing/Structure Inspection
tempered glass needed next to sliding door (Operating side)
Anchor bolts needed on bearing walls
Over lap top plate of walls in corners and butt joints
Inspector Comments:
03/16/2011PassTed DyeResidential Framing/Structure Inspection
03/18/2011PassTed DyeResidential Insulation Inspection
03/22/2011PassTed DyeResidential Sheetrock/Drywall Inspection
04/22/2011PassQuinton OwensSidewalk Inspection
Started pour early. Base thickness at edge of sidewalk about 6 - 7 inches.Inspector Comments:
04/22/2011PassQuinton OwensResidential Building Final
Building Final OKInspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 11-00012
2280 W 960 S - New SFR
2280 W 960 S
New Single Family Residence
Permit Status of (Open) as of Report Date: 05/12/2020 8:53 am
Permit
Inspection
Summary
Electrical
02/24/2011PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power.Inspector Comments:
03/15/2011FailBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Need to install nail plates throughout the dwelling, need to provide access to the
ufer connection or provide an irreversible connection, need to add a receptacle
on the short wall in the west bedroom below the switch, call for a re-inspect
when ready.
Inspector Comments:
03/16/2011PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover.Inspector Comments:
04/22/2011PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and a C.O.-A/C unit is not being installed-disconnect is
mounted.
Inspector Comments:
Mechanical
03/15/2011FailPLL ADMINHVAC Rough-in
As per Jon Berry
Garage ducting needs to be insulated
furnace needs a shut off device on condensate secondary overflow.
Inspector Comments:
03/15/2011PassPLL ADMINHVAC Rough-in
As per Jon BerryInspector Comments:
04/22/2011FailPLL ADMINHVAC Final Inspection
As per Jon Berry
needs secondaey overflow shut off.
Inspector Comments:
05/10/2011PassPLL ADMINHVAC Final Inspection
As per Jon BerryInspector Comments:
Plumbing
02/16/2011PassPLL ADMINPlumbing Underground Inspection
As per Brad Johnson
Approved for cover.
Inspector Comments:
05/10/2011PassSAUREY AMANDAPlumbing Sewer
03/17/11: Approved for cover, per Bradley Johnson.Inspector Comments:
05/10/2011PassDon AllenPlumbing Water
03/17/11: Approved for cover, per Bradley Johnson.Inspector Comments:
05/10/2011PassSAUREY AMANDAPlumbing Rough-in
03/10/10: Rough good! Approved per Jeff Hackworth.Inspector Comments:
05/10/2011PassSAUREY AMANDAPlumbing Final Inspection
04/19/11: Approved per Brad Johnson.
4/25/11: Approved for Plumbing per Brad Johnson
Inspector Comments: