Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00012 - 2280 W 960 S - New SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 05/12/2020 8:53 am Permit Details Permit Number: 11-00012 2280 W 960 S - New SFR 2280 W 960 S New Single Family Residence Permit Issued Date: 08/21/2014 Permit Inspection Statistics 22Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 77.27% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 02/04/2011PassTed DyeResidential Footing Inspection Overlaps look good Rebar suspended in the air OK to pour Inspector Comments: 02/07/2011PassTed DyeFoundation Inspection Ufer in west wall in south corner. Over laps OK Instructor to put hot water in bottom of form to melt snow. Inspector Comments: 03/07/2011FailTed DyeResidential Framing/Structure Inspection Sheeting on east wall in front bedroom is not pulled up tight against stud. Same as above in master bath east wall. POST PERMIT Inspector Comments: 03/15/2011FailTed DyeResidential Framing/Structure Inspection tempered glass needed next to sliding door (Operating side) Anchor bolts needed on bearing walls Over lap top plate of walls in corners and butt joints Inspector Comments: 03/16/2011PassTed DyeResidential Framing/Structure Inspection 03/18/2011PassTed DyeResidential Insulation Inspection 03/22/2011PassTed DyeResidential Sheetrock/Drywall Inspection 04/22/2011PassQuinton OwensSidewalk Inspection Started pour early. Base thickness at edge of sidewalk about 6 - 7 inches.Inspector Comments: 04/22/2011PassQuinton OwensResidential Building Final Building Final OKInspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 11-00012 2280 W 960 S - New SFR 2280 W 960 S New Single Family Residence Permit Status of (Open) as of Report Date: 05/12/2020 8:53 am Permit Inspection Summary Electrical 02/24/2011PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 03/15/2011FailBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Need to install nail plates throughout the dwelling, need to provide access to the ufer connection or provide an irreversible connection, need to add a receptacle on the short wall in the west bedroom below the switch, call for a re-inspect when ready. Inspector Comments: 03/16/2011PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover.Inspector Comments: 04/22/2011PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and a C.O.-A/C unit is not being installed-disconnect is mounted. Inspector Comments: Mechanical 03/15/2011FailPLL ADMINHVAC Rough-in As per Jon Berry Garage ducting needs to be insulated furnace needs a shut off device on condensate secondary overflow. Inspector Comments: 03/15/2011PassPLL ADMINHVAC Rough-in As per Jon BerryInspector Comments: 04/22/2011FailPLL ADMINHVAC Final Inspection As per Jon Berry needs secondaey overflow shut off. Inspector Comments: 05/10/2011PassPLL ADMINHVAC Final Inspection As per Jon BerryInspector Comments: Plumbing 02/16/2011PassPLL ADMINPlumbing Underground Inspection As per Brad Johnson Approved for cover. Inspector Comments: 05/10/2011PassSAUREY AMANDAPlumbing Sewer 03/17/11: Approved for cover, per Bradley Johnson.Inspector Comments: 05/10/2011PassDon AllenPlumbing Water 03/17/11: Approved for cover, per Bradley Johnson.Inspector Comments: 05/10/2011PassSAUREY AMANDAPlumbing Rough-in 03/10/10: Rough good! Approved per Jeff Hackworth.Inspector Comments: 05/10/2011PassSAUREY AMANDAPlumbing Final Inspection 04/19/11: Approved per Brad Johnson. 4/25/11: Approved for Plumbing per Brad Johnson Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 11-00012 2280 W 960 S - New SFR 2280 W 960 S New Single Family Residence Permit Status of (Open) as of Report Date: 05/12/2020 8:53 am Permit Inspection Summary Page 3 of 3