HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00018 - The Mandarin - RemodelPermit Inspection Summary Permit Status of (Open) as of Report Date: 05/12/2020 8:43 am Permit Details Permit Number: 11-00018 The Mandarin - Remodel 222 E 7th N Commercial - Remodel Permit Issued Date: 08/26/2014 Permit Inspection Statistics 18Total Inspections Completed: 14Total Inspections Passed: Inspection Pass Rate: 77.78% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 03/16/2011PassPLL ADMINCommercial Framing/Structure Inspection As per Jon Berry Interior wall framing looks good. Inspector Comments: 03/18/2011PassPLL ADMINCommercial Insulation Inspection As per Jon Berry Insulation OK to cover. Inspector Comments: 03/30/2011PassPLL ADMINCommercial Sheetrock/Drywall Inspection As per Jon Berry Drywall screws OK to cover. Inspector Comments: 05/02/2011PassQuinton OwensCommercial Building Final Restroom signs being picked up today in Idaho Falls. Grease pit was to be emptied first few days in May. Inspector Comments: Electrical 03/22/2011FailBret StoddardCommercial Electrical Rough-in Need to verify the listing of the cooler in the kitchen area, need to strap the SE cable and the NM-B wire above the sub-panel by the bathrooms, need a connector on the EMT above the cooler for the NM-B cable, call for a re-inspect when ready-tomorrow. Inspector Comments: 03/23/2011PassBret StoddardCommercial Electrical Rough-in Approved for Cover - Kitchen area, soda machine area, bathrooms.Inspector Comments: 04/26/2011FailBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Need to install a cover for the receptacle-furnace room, need breaker locks for the water heaters, plug strips on the counter P.O.S. not installed, convenience outlet needed behind the building for the condensing units, call for a re-inspect when ready. Inspector Comments: 04/27/2011FailBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Need to install breaker locks for the water heaters circuits(2), convenience outlet not installed behind the building, call for a re-inspect when ready. 5/3-still need breaker locks installed. Inspector Comments: 05/12/2011PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 11-00018 The Mandarin - Remodel 222 E 7th N Commercial - Remodel Permit Status of (Open) as of Report Date: 05/12/2020 8:43 am Permit Inspection Summary Fire 05/02/2011PassBret StoddardFire Department Final Inspection Exhaust fan test was witnessed by Quinton-approx. 95 degree as per general contractor, Approved for a final-fire. Inspector Comments: Mechanical 05/02/2011PassQuinton OwensHVAC Final Inspection Previous item: Checked temperature sensor on kitchen hood exhaust. QO 5/03 Inspected hood and found no duct wrap on Grease duct and clearances not met Disapproved use of hood and appliances. val approved use today at grand opening with Fire watch. JB 5/12 Final OK hood duct wrapped. Inspector Comments: 05/03/2011FailPLL ADMINHVAC Final Inspection As per Jon Berry Grease duct not fire wrapped. Do not use until wrapped. Inspector Comments: 05/16/2011PassPLL ADMINHVAC Rough-in As per Jon Berry PCW Inspector Comments: Plumbing 02/25/2011PassPLL ADMINPlumbing Sewer As per Brad JohnsonInspector Comments: 02/25/2011PassDon AllenPlumbing Water As per Brad JohnsonInspector Comments: 03/02/2011PassPLL ADMINPlumbing Underground Inspection As per Brad JohnsonInspector Comments: 04/27/2011PassSAUREY AMANDAPlumbing Final Inspection 04/25/11: Final plumbing approved, per Jeff Hackworth.Inspector Comments: 05/10/2011PassSAUREY AMANDAPlumbing Rough-in 02/28/11: Rough in on underground is good, per Jeff Hackworth. 03/17/11: Visual on vents/rough on dwv, still needs a test. good to insulate only, per Jeff Hackworth. Inspector Comments: Page 2 of 2