HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00038 - 653 Autumn Dr - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 05/11/2020 1:05 pm Permit Details Permit Number: 11-00038 653 Autumn Dr - SFR 653 Autumn Dr New Single Family Residence Permit Issued Date: 08/27/2014 Permit Inspection Statistics 22Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 68.18% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 02/11/2011PassTed DyeResidential Footing Inspection OK to pour.Inspector Comments: 02/15/2011PassTed DyeFoundation Inspection rebar in place ufer bar installed next to electrical conduits Inspector Comments: 05/06/2011FailTed DyeResidential Framing/Structure Inspection Fireblocking needed at furdowns in basement Smoke detector needed at bottom of stairs (basement) Inspector Comments: 05/13/2011FailTed DyeResidential Framing/Structure Inspection Fireblocking needed at furdowns in basement Smoke detector needed at bottom of stairs (basement) Inspector Comments: 05/13/2011FailTed DyeResidential Insulation Inspection check framing notes insulate (seal) penetrations in top plate to attic Inspector Comments: 05/17/2011PassTed DyeResidential Framing/Structure Inspection 05/25/2011FailTed DyeResidential Sheetrock/Drywall Inspection Finished basement Remove sheetrock and insulation from around B vent Note Wall sheetrocked before i could check fire blocking. Inspector Comments: 05/30/2011PassTed DyeResidential Insulation Inspection 05/30/2011PassTed DyeResidential Sheetrock/Drywall Inspection 06/23/2011PassTed DyeSidewalk Inspection front side walk ok to pour 12"-14" baseInspector Comments: 08/05/2011FailQuinton OwensResidential Building Final Landing missing at back door. Attic access lid missing Finish guardrail/handrail in garage. Inspector Comments: 08/08/2011FailTed DyeResidential Building Final 3' landing needed on back door.Inspector Comments: 08/18/2011PassTed DyeResidential Building Final Page 1 of 2 (Continued) Permit Details Permit Number: 11-00038 653 Autumn Dr - SFR 653 Autumn Dr New Single Family Residence Permit Status of (Open) as of Report Date: 05/11/2020 1:05 pm Permit Inspection Summary Electrical 03/23/2011PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 05/05/2011PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover.Inspector Comments: 08/05/2011FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Intersystem bonding termination required at the main service, tamper resistant receptacle needed in the master bathroom, kitchen receptacles not GFCI protected, GFCI protection required in the furnace room-receptacles, bathroom receptacles downstairs reverse polarity(x2), closet light to close to the shelving downstairs SW bedroom, receptacle missing gas range, A/C unit max breaker size 40A, range breaker 40A max-#8 wire, finish labeling the panel-#27, light missing under shelving in garage, call for a re-inspect when ready. Inspector Comments: 08/09/2011PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-range receptacle was changed to 120V instead of 240V(20A)-gas. Inspector Comments: Mechanical 05/06/2011PassPLL ADMINHVAC Rough-in As per Jon Berry HVAC rough looks good. OK Inspector Comments: 08/05/2011PassPLL ADMINHVAC Final Inspection As per Jon Berry HVAC final completed OK Inspector Comments: Plumbing 03/02/2011PassSAUREY AMANDAPlumbing Underground Inspection 02/18/11: Sewer main/underground test looks good, per Jeff Hackworth.Inspector Comments: 05/02/2011PassSAUREY AMANDAPlumbing Rough-in 04/29/11: Rough plumbing looks good, approved per Jeff Hackworth.Inspector Comments: 08/08/2011PassDon AllenPlumbing Final Inspection Its all good to move in on the plumbing side.Inspector Comments: Page 2 of 2