Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00052 - 918 S 2400 W - New SFR TwinhomePermit Inspection Summary Permit Status of (Open) as of Report Date: 05/08/2020 11:50 am Permit Details Permit Number: 11-00052 918 S 2400 W - New SFR Twinhome 918 S 2400 W New Single Family Residence Permit Issued Date: 08/28/2014 Permit Inspection Statistics 23Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 73.91% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 03/16/2011PassTed DyeResidential Footing Inspection 03/18/2011PassTed DyeFoundation Inspection 04/20/2011FailQuinton OwensResidential Framing/Structure Inspection Some anchorbolts missing washers and nuts. 2hr fire separation above ceiling? Separation at front required. Firecaulk gaps and penetrations. Truss Details missing. Inspector Comments: 04/22/2011PassQuinton OwensResidential Insulation Inspection 4/22/11 - Firewall and framing items done. Insulation OK 4/25/11 - Tedd - OK to hang drywall. Inspector Comments: 04/28/2011FailTed DyeResidential Framing/Structure Inspection Latteral bracing needed in trusses Missing bracing circled one truss spec Broken webb on one truss Inspector Comments: 04/28/2011PassTed DyeResidential Framing/Structure Inspection 4/12/11 - Tedd - Sheeting Only 4/22/11 - Quintono - Firewall done, Firecaulk gaps over patio at bottom of truss. Need Truss details; to be checked before drywall.(both units). 4/28/11 - Tedd - Ok all laterals in place Broken truss repaired as per engineers instructions Engineering is in file Inspector Comments: 05/02/2011PassTed DyeResidential Sheetrock/Drywall Inspection OKInspector Comments: 06/03/2011FailTed DyeResidential Building Final Need number on outside of unit Back Step missing Range and dishwasher missing Inspector Comments: 06/23/2011PassTed DyeSidewalk Inspection 06/23/2011PassTed DyeResidential Building Final Page 1 of 3 (Continued) Permit Details Permit Number: 11-00052 918 S 2400 W - New SFR Twinhome 918 S 2400 W New Single Family Residence Permit Status of (Open) as of Report Date: 05/08/2020 11:50 am Permit Inspection Summary Electrical 03/28/2011PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-no receptacles are mounted.Inspector Comments: 04/20/2011PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover.Inspector Comments: 06/03/2011FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection A/C unit 25A max breaker-30A installed, furnace needs flex installed on the NM cable, closet light clearance not sufficient, call for a re-inspect when ready. Inspector Comments: 06/23/2011FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Door was locked-left message for Tyson-5:15pm.Inspector Comments: 06/27/2011PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and a C.O.Inspector Comments: Mechanical 04/18/2011FailPLL ADMINHVAC Rough-in As per Jon Berry Support gasline and seal ducting in furnace room Inspector Comments: 04/20/2011PassPLL ADMINHVAC Rough-in As per Jon Berry HVAC reinspect OK Inspector Comments: 06/15/2011PassPLL ADMINHVAC Final Inspection As per Jon Berry HVAC final Completed. OK. Inspector Comments: Plumbing 03/22/2011PassPLL ADMINPlumbing Sewer Approved by Brad JohnsonInspector Comments: 03/22/2011PassDon AllenPlumbing Water Approved by Brad JohnsonInspector Comments: 03/29/2011PassSAUREY AMANDAPlumbing Underground Inspection Underground looks good, per Jeff Hackworth.Inspector Comments: 04/18/2011PassPLL ADMINPlumbing Rough-in As per Brad JohnsonInspector Comments: 06/02/2011PassSAUREY AMANDAPlumbing Final Inspection Final plumbing approved, per Jeff Hackworth.Inspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 11-00052 918 S 2400 W - New SFR Twinhome 918 S 2400 W New Single Family Residence Permit Status of (Open) as of Report Date: 05/08/2020 11:50 am Permit Inspection Summary Page 3 of 3