HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00064 - 661 Dell Dr - New SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 05/08/2020 11:34 am
Permit Details Permit Number: 11-00064
661 Dell Dr - New SFR
661 Dell Dr
New Single Family Residence
Permit Issued Date: 09/15/2014
Permit Inspection Statistics
19Total Inspections Completed:
15Total Inspections Passed:
Inspection Pass Rate: 78.95%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building
04/26/2011PassTed DyeResidential Footing Inspection
3/15/11 - Stake out approved
3/17/11 - Footing approved
4/26/11 - garage footings onl3 rebar epoxyed into wall
overlaps looked good. (approx 24-30 inches)
Concrete poured at a 4" slump.
Inspector Comments:
04/27/2011PassTed DyeFoundation Inspection
3/23/11 - Approved
4/27/11 - Garage Foundation Only
Overlaps of rebar looked good
Epoxyed rebar to house foundation
Ufer installed in East wall south corner next to 4" electrical conduit.
Inspector Comments:
06/23/2011FailTed DyeResidential Framing/Structure Inspection
Truss inspection OK
Sheeting inspection OK
OK to tyvec and install windows and doors
CALL when plumbers, electricians and HVAC subcontractors are finished.
Inspector Comments:
07/12/2011PassTed DyeResidential Framing/Structure Inspection
all looked good.Inspector Comments:
07/28/2011PassTed DyeResidential Insulation Inspection
walls blown with celluloseInspector Comments:
08/04/2011PassQuinton OwensResidential Sheetrock/Drywall Inspection
8/5 (QO)- Upstairs only approved - noted various locations missing fasteners. OK
to tape when finished. Attic Access too small (22" by 30" min)
Basement not ready.
Inspector Comments:
11/03/2011FailTed DyeResidential Building Final
Window well ladder required in bedroomsInspector Comments:
11/10/2011PassTed DyeSidewalk Inspection
Sidewalk was existing and was not removedInspector Comments:
11/10/2011PassTed DyeResidential Building Final
Ok for C.O.Inspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 11-00064
661 Dell Dr - New SFR
661 Dell Dr
New Single Family Residence
Permit Status of (Open) as of Report Date: 05/08/2020 11:34 am
Permit
Inspection
Summary
Electrical
07/01/2011PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power.Inspector Comments:
07/12/2011PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover-upstairs bedroom outlets on all 2' wall spaces.Inspector Comments:
11/03/2011FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Need to install GFCI protection for the garage door openers, outlet in garage
needs spark ring by vacuum, cover in the entryway missing outside, breaker locks
needed for oven and range, closet lights need to be fully enclosed in the master
bedroom, call for a re-inspect when ready.
Inspector Comments:
11/04/2011PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.Inspector Comments:
Mechanical
07/13/2011PassPLL ADMINHVAC Rough-in
As per Jon Berry
HVAC rough looks good fireplace & furnace venting look good.
Inspector Comments:
11/03/2011FailPLL ADMINHVAC Final Inspection
As per Jon Berry
Ducting in furnace room needs to be sealed.
Furnace thermostat needs to be programmable.
Inspector Comments:
11/04/2011PassPLL ADMINHVAC Final Inspection
As per Jon Berry
Approved after thermostat programable and ducts sealed.
HVAC Final Completed.
Inspector Comments:
Plumbing
04/01/2011PassPLL ADMINPlumbing Underground Inspection
Approved by Brad JohnsonInspector Comments:
06/17/2011PassSAUREY AMANDAPlumbing Rough-in
Okay to cover, per Larry Watts.Inspector Comments:
10/31/2011PassDon AllenPlumbing Final Inspection
all good for the c/oInspector Comments:
Page 2 of 2