Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00064 - 661 Dell Dr - New SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 05/08/2020 11:34 am Permit Details Permit Number: 11-00064 661 Dell Dr - New SFR 661 Dell Dr New Single Family Residence Permit Issued Date: 09/15/2014 Permit Inspection Statistics 19Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate: 78.95% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 04/26/2011PassTed DyeResidential Footing Inspection 3/15/11 - Stake out approved 3/17/11 - Footing approved 4/26/11 - garage footings onl3 rebar epoxyed into wall overlaps looked good. (approx 24-30 inches) Concrete poured at a 4" slump. Inspector Comments: 04/27/2011PassTed DyeFoundation Inspection 3/23/11 - Approved 4/27/11 - Garage Foundation Only Overlaps of rebar looked good Epoxyed rebar to house foundation Ufer installed in East wall south corner next to 4" electrical conduit. Inspector Comments: 06/23/2011FailTed DyeResidential Framing/Structure Inspection Truss inspection OK Sheeting inspection OK OK to tyvec and install windows and doors CALL when plumbers, electricians and HVAC subcontractors are finished. Inspector Comments: 07/12/2011PassTed DyeResidential Framing/Structure Inspection all looked good.Inspector Comments: 07/28/2011PassTed DyeResidential Insulation Inspection walls blown with celluloseInspector Comments: 08/04/2011PassQuinton OwensResidential Sheetrock/Drywall Inspection 8/5 (QO)- Upstairs only approved - noted various locations missing fasteners. OK to tape when finished. Attic Access too small (22" by 30" min) Basement not ready. Inspector Comments: 11/03/2011FailTed DyeResidential Building Final Window well ladder required in bedroomsInspector Comments: 11/10/2011PassTed DyeSidewalk Inspection Sidewalk was existing and was not removedInspector Comments: 11/10/2011PassTed DyeResidential Building Final Ok for C.O.Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 11-00064 661 Dell Dr - New SFR 661 Dell Dr New Single Family Residence Permit Status of (Open) as of Report Date: 05/08/2020 11:34 am Permit Inspection Summary Electrical 07/01/2011PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 07/12/2011PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-upstairs bedroom outlets on all 2' wall spaces.Inspector Comments: 11/03/2011FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Need to install GFCI protection for the garage door openers, outlet in garage needs spark ring by vacuum, cover in the entryway missing outside, breaker locks needed for oven and range, closet lights need to be fully enclosed in the master bedroom, call for a re-inspect when ready. Inspector Comments: 11/04/2011PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.Inspector Comments: Mechanical 07/13/2011PassPLL ADMINHVAC Rough-in As per Jon Berry HVAC rough looks good fireplace & furnace venting look good. Inspector Comments: 11/03/2011FailPLL ADMINHVAC Final Inspection As per Jon Berry Ducting in furnace room needs to be sealed. Furnace thermostat needs to be programmable. Inspector Comments: 11/04/2011PassPLL ADMINHVAC Final Inspection As per Jon Berry Approved after thermostat programable and ducts sealed. HVAC Final Completed. Inspector Comments: Plumbing 04/01/2011PassPLL ADMINPlumbing Underground Inspection Approved by Brad JohnsonInspector Comments: 06/17/2011PassSAUREY AMANDAPlumbing Rough-in Okay to cover, per Larry Watts.Inspector Comments: 10/31/2011PassDon AllenPlumbing Final Inspection all good for the c/oInspector Comments: Page 2 of 2