HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00071 - Physical Therapy RemodelPermit Inspection Summary Permit Status of (Open) as of Report Date: 05/08/2020 11:16 am Permit Details Permit Number: 11-00071 Physical Therapy Remodel 217 N 2nd E Commercial - Remodel Permit Issued Date: 09/03/2014 Permit Inspection Statistics 13Total Inspections Completed: 9Total Inspections Passed: Inspection Pass Rate: 69.23% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 03/28/2011PassPLL ADMINCommercial Framing/Structure Inspection As per Jon Berry Interior framing looks good. OK to cover. Inspector Comments: 04/04/2011PassQuinton OwensCommercial Sheetrock/Drywall Inspection Missed fasteners in a few locations, instructed to fix.Inspector Comments: 05/26/2011FailPLL ADMINCommercial Building Final As per Jon Berry Side grab bar d/n end at 54" 3' rear grab bar required Cabinet c/n be between sink and toilet Emergency exit light required in reception area. Inspector Comments: 07/13/2011PassPLL ADMINCommercial Building Final As per Jon Berry 7/13/11 - Building Final Completed. 7/20/11 - Building, Fire, Mech Finals Completed. Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 11-00071 Physical Therapy Remodel 217 N 2nd E Commercial - Remodel Permit Status of (Open) as of Report Date: 05/08/2020 11:16 am Permit Inspection Summary Electrical 03/25/2011PassBret StoddardCommercial Electrical Rough-in Approved for cover-main service and panels are existing, north rooms are wired with green MC cable. Inspector Comments: 05/16/2011FailBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Blank cover needed for the furnace in the laundry room, need to install a receptacle for the data panel-cord connected, washer and fridge need GFCI protection-6' from the edge of the sink, GFCI protection for soffit receptacles?-verify-they are as per Scott, flourescent lights in the exam room are on dimmers-dimmable ballasts?-verify-as per Scott-yes, back portion not completed, call for a re-inspect when ready. Inspector Comments: 07/13/2011FailBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Need to install a breaker lock for the heater circuit in the west side, closet light not installed in the west side, call for a re-inspect when ready. Inspector Comments: 07/20/2011PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and a C.O. entire building-need to keep panel clearances in the mech. room in front of the panels. Inspector Comments: Fire 07/13/2011FailBret StoddardFire Department Final Inspection Need to install a fire extinguisher by the main entrance, call for a re-inspect when ready-inspected this at the same time as the electrical-no separate ticket was written. Inspector Comments: 07/20/2011PassPLL ADMINFire Department Final Inspection As per Jon Berry Extinguishers installed in both units. Inspector Comments: Mechanical 07/13/2011PassPLL ADMINHVAC Final Inspection As per Jon Berry HVAC Final Completed. Inspector Comments: Plumbing 03/23/2011PassPLL ADMINPlumbing Rough-in Approved by Brad JohnsonInspector Comments: 07/13/2011PassSAUREY AMANDAPlumbing Final Inspection No Discrepancies Noted, approved per Larry Watts.Inspector Comments: Page 2 of 2