Loading...
HomeMy WebLinkAboutENGINEERED GARAGE - 20-00211 - Dayton - 1092 Cypress Loop - New SFRGENERAL STRUCTURAL NOTES (DRAWING NOTES) A. CODES AND SPECIFICATIONS 1. International Building Code (IBC) - 2015 Edition 2. ACI 318-14 Building Code Requirement's for Reinforced Concrete 3. ANSVAWC National Design Specification (NDS) & Suppl. for Wood Const. - 2015 Edition 4. ASCE 7-10 Min. Design Loads for Buildings and other Structures. B. DESIGN LOADS UNIFORM (PSF) 1. Roof Loads a. Live Load 20 PSF b. Snow Load Design Snow Load 35 PSF Flat Roof Snow Load Pf = 35.0 Ce=1.0;Ct=1.0;Is=1.0 Ground Snow Load 50 Sloped Roof Ps =35.0; Cs = 1.0 2. Lateral Loads a. Wind Load 115 MPH (3 Sec Gust) Risk Cat= 11; EXP = C Encl. Cat. - Enclosed Building Internal Pressure Coef. +/- 0.18 Components & Cladding 12,8 PSF b. Seismic Load: Risk Cat: II Importance Factor = 1.0 Ss = 43.10%" G; S1 = 15.400% G Site Class = D Sds = 0.418; Sdi = 0.224' Seismic Design Category',= D Basic Seismic System = Bearing wall System Design Base Shear V = 0'.064 W Seismic Response Coef. ',Cs = 0.064 Response Modification Factor R = 6.5 Analysis Procedure = Equivalent Lateral - Force Analysis C.FOUNDATIONS (BY OTHERS) D. MATERIALS 1. Dimensional Lumber #2 Douglas Fir 2. Concrete fc - Ftgs, Walls 3500 PSI Exposure Class = F1 Air Content 50/6 Max Water -Cement Ratio 0.55 Max Aggregrate size j 3/4" 3. Reinforcing Steel ASTM A615 - Grade 60 4. Anchor Bolts A36 / F1554 GRADE 36 E. LUMBER 1. Do not notch any structural wood member unless shown on the drawings. 2. Install and follow all manufacturers guidelines for Engineered Wood I members and LVL products. --Do not notch or cut flanges of Eng.Wood I Members.-- 3. All nails shall be common wire nails. Any nails exposed to weather or moisture shall be of stainless steel or shall be galvanized; 4. Nailing to conform to IBC Table 2304.10.1 unless noted otherwise (See Nailing Schedule). 5. Wherever possible nails should be driven perpendicular to the grain instead of toe nail 6. Where wood tends to split, holes for nails shall be bored a diameter smaller that of the nails. 7. Plywood face grain must be perpendicular to its supports. 8. Any wood members in,contact with concrete or earth shall be pressure -treated wood or wood that is decay resistant (redwood or cedar). 9. Wet use adhesives shall be used on altglulam members subjected to possible moisture. 10. Roof trusses to be designed and engineered by supplier to meet the design loads herein indicated in addition to any and all drifting loads, wind loads, equipment loads and other loads as indicated on framing plan. Submit shop drawings and calculations for review. WIND COMPONENT AND CLADDING SCHEDULE WIND PRESSURE (PSF) 10 SF 50 SF 100 SF ROOF AT LEAST 6-0" +10.01-13.8 +10.0,-12.9 +10.0,-12.6 AWAY FROM ANY EDGE DO NOT SCALE Et U MANUF. TRUSSES ROOF WITHIN 6'-0" +10.0,-35.6 +10.0,-30.2 +10.0,-27.9 OF ANY EDGE � d APA RATED WOOD PANEL WALL AT LEAST 6-0" AWAY +15.1, -16:4 +13.5,-1 +12.9,-14.1 FROM ANY CORNER �- W O WALL WITHIN 6' 0" +15.11-20.2 +13.5,-17.1 +112.9,-115.7 OF ANY CORNER SUPPORTED PANEL EDGES g' 11. Truss manufacturer to provide truss to truss connection details. NAILING SCHEDULE 3 SECTION 15/32" APA Rated 32/16 Roof Sheathing Boundary nailing - 8d @ 6" o.c. S1 DO NOT SCALE No blocking required unless shown End nailing - 8d @ 6" o.c. on framing plan. See typical detail. Side nailing - 8d @ 6" o.c. use panel clips at unsupported edges. Intermediate nailing - 8d @ 12" o.c. SHEAR WALLS See Shear Wall Schedule GENERALNOTES 1. Adequate shoring and bracing of all structural members during construction shall be provided. ' 2. Any proposed field changes shall have prior approval from the Engineer. 3. Contractor shall verify all dimensions in the field. Any variation from the drawings shall be brought to the attention of the Engineer. 4. Install Simpson hardware as per Manufacturers requirements. 5. Details are representations/ depictions only. Follow written callouts. 6. NO CHANGES PERMITTED WITHOUT EXPRESS WRITTEN PERMISSION OF ENGINEER PRE-MANUF. TRUSSES (SEE FRAMING PLAN) ROOF SHEATHING (SEE NAILING SCHED.) BOUNDARY NAILING (SEE NAILING SCHED.) 2x BLOCKING 2xDBLTOP PLATE (SEE SPLICE DETAIL) SIMPSON H2.5A 2x WOOD STUD WALL SILL PLATE WIND & SEISMIC TIE (SEE FRAMING PLAN) WALL SHEATHING (SEE NAILING SCHED.) RIM JOIST 2 SECTION 5 SECTION S1 DO NOT SCALE S1 DO NOT SCALE DRAG STRUT TRUSS DESIGN FOR 150 pit OR SHEATH ONE SIDE SIMPSON DSC (BEND STRAP DOWN WALL) 4 SECTION S 1 DO NOT SCALE DRAG STRUT TRUSS DESIGN FOR 150 pit OR SHEATH ONE SIDE FLOOR OR ROOF 4'- 0" MIN. LAP JOIST SPACE 2 ROWS 16d NAILS @ 4" O.C. STAGGERED �-- DBL TOP PLATE CHORD MEMBER SPLICE DETAIL W SIZE C SECTION EPDXY 1/2" oO 5" SIMPSON DSC / 0 S1 DO NOT SCALE Et U MANUF. TRUSSES c AT FDTN W SIZE UCL hef EPDXY 1/2" oO 5" .__I 0 10" DIAPHRAGM BOUNDARY Et U 0 W Z cc AT FDTN O CL U Co w Q � d APA RATED WOOD PANEL ALSTHDB IIr wz w¢¢ cWi 3 W W O� 8„ 0 �- DIAPHRAGM BOUNDARY 1 3/4" MIN. 13/4 MIN. (SEE NAILING SCHED.) WALL STUDS APA RATED WOOD PANEL 6" OR 8" CONC. (SEE FRAMING PLAN) Z STEM WALL CONTINUOUS PANEL JOINT WALL SEE NAILING SCHED) S HED)EATHING Ci ;r T SUPPORTED PANEL EDGES (SEE NAILING SCHED:) 2x STUDS BLOCKED EDGE Ili @ EACH HOEDOWN ANCHOR BOLT MUST BE SHEAR WALL OR PLACED IN MIDDLE THIRD (SEE SCHEDULE) BUILDING EDGE CONC. EDGE OF PLATE SIMPSON HOEDOWN SILL PLATE (SEE SCHED INTERMEDIATE SUPPORTS C ' Qi (SEE NAILING SCHED.) BLOCKING CUT & FITTED 1/3 1/3 1/3 III F T ouAMOnKl Uel Marta EPDXY ANCHOR BOLT OPTION SIZE BY OTHERS hef EPDXY 1/2" 81/2- 5" w 5/8" 10" DIAPHRAGM BOUNDARY SIMPSON SET EPDXY SYSTEM OR EQUIV. a ~ a U Q = Z AT FDTN (SEE NAILING SCHED.) _ w 0 z a Ox Z U 3 Z APA RATED WOOD PANEL ALSTHDB IIr wz w¢¢ cWi 3 W W 2 8„ 8" �- W O ?� ALLOWED CONTINUOUS PANEL JOINT o a w W o Z¢ F- w g Lu [ j SUPPORTED PANEL EDGES g' U ¢ O U 5 w O 3 O C F m 0¢ J co (SEE NAILING SCHED.) zz W (r or UNBLOCKED EDGE PARTIAL FIRST FLOOR SHEAR WALL PLAN d M � Z O v~) w w m J0 HDU2 SHEAR WALL OR 1/8" = 1,-O" _ ¢ F ar O w z O 1- F a to _ O v x F v m 5/8" B14" 3" 2/S1 BUILDING EDGE o F- x Z O Fc N t m a e INTERMEDIATE SUPPORTS N (SEE NIALING SCHED.) ROOF RAFTERS/TRUSS OR FLOOR JOISTSN cc W N >. 1- X AQ c c 4 m N V Ir O do Z O UNBLOCKED DIAPHRAGM NAILING o Q M a. T CnW o= PROJECT NO. 220118 W SHEET NO. , Z S1 OF ONE DIAPHRAGM BOUNDARY 1 3/4" MIN. 13/4 MIN. (SEE NAILING SCHED.) WALL STUDS APA RATED WOOD PANEL 6" OR 8" CONC. (SEE FRAMING PLAN) Z STEM WALL CONTINUOUS PANEL JOINT WALL SEE NAILING SCHED) S HED)EATHING Ci ;r T SUPPORTED PANEL EDGES (SEE NAILING SCHED:) 2x STUDS BLOCKED EDGE Ili @ EACH HOEDOWN ANCHOR BOLT MUST BE SHEAR WALL OR PLACED IN MIDDLE THIRD (SEE SCHEDULE) BUILDING EDGE CONC. EDGE OF PLATE SIMPSON HOEDOWN SILL PLATE (SEE SCHED INTERMEDIATE SUPPORTS C ' Qi (SEE NAILING SCHED.) BLOCKING CUT & FITTED 1/3 1/3 1/3 III F T ouAMOnKl Uel Marta EPDXY ANCHOR BOLT OPTION SIZE de hef EPDXY 1/2" 81/2- 5" SIMPSON SET EPDXY SYSTEM OR EQUIV. 5/8" 10" 5" SIMPSON SET EPDXY SYSTEM OR EQUIV. Z m `� HOLDOWN OR STbAP WOOD WALL CONCRETE WALL HOLDOWN ANCHOR BOLTS DETAILS LABEL SHEAR WALL W o m rn HOLDOWN HOOK LENGTH L � D/4 Z AT FDTN FLOOR # STUDS FASTENERS 2 1 3/4" MIN. 1 3/4" MIN. W U 3 Z (SEE FRAMING PLAN) ALSTHDB z 2 8„ 8" J W O ?� ALLOWED SINKERS 0 HEAD [ j -OR- 2x STUDS w O Z o J co zz W (r or o J0 HDU2 2 1/2"SCREWS 8" 5/8" B14" 3" 2/S1 LU F- x Z O Fc N t m a e N C7 cc H LOLO "' 1- X AQ c c D N V Ir O do Z O rn m `� HOLDOWN OR STbAP WOOD WALL CONCRETE WALL HOLDOWN ANCHOR BOLTS DETAILS LABEL SHEAR WALL Z o m STUDS �p,T,) HOLDOWN HOOK LENGTH L � D/4 Z AT FDTN FLOOR # STUDS FASTENERS 2 1 3/4" MIN. 1 3/4" MIN. W U 3 F (SEE FRAMING PLAN) ALSTHDB z 2 8„ 8" MIN. W eh ?� ALLOWED SINKERS 0 HEAD [ j -OR- 2x STUDS w O Z o J co zz W (r (6) SDS 1/4X2 o J0 HDU2 2 1/2"SCREWS 8" 5/8" B14" 3" 2/S1 LU F- x Z O Fc N t m a e LOOR SHEA HING BETWEEN JOISTS AT PANEL O Oyu o (SEE NAILING SCHED) ROOF RAFTER/TRUSS, WALL STUD, SIDES (TYP) r I - OR FLOOR JOIST z BOTTOM PLATE BLOCKED DIAPHRAGM NAILING B SECTION S1 DO NOT SCALE L 10 01 .01 U3 U3 U3 5/8"0 MIN ` D!3 NO NOTCHING D = D/3 MAX ALLOWED m HOLDOWN SCHEDULE 1" MAX O zQ HOLDOWN OR STbAP WOOD WALL CONCRETE WALL HOLDOWN ANCHOR BOLTS DETAILS LABEL SHEAR WALL FLOOR TO THICKNESS LAYERS (SEENOTEI) (7/16"MIN. CROWN) STUDS �p,T,) HOLDOWN HOOK LENGTH L � D/4 Z AT FDTN FLOOR # STUDS FASTENERS WALL SIZE BOLT 0 EMBED. (hef) (eh) 2-1/4 (SEE FRAMING PLAN) ALSTHDB z 2 8„ 8" 1/Si H1 eh ?� ALLOWED SINKERS 0 HEAD [ j -OR- 2x STUDS w O Z o J co zz W (r (6) SDS 1/4X2 J0 HDU2 2 1/2"SCREWS 8" 5/8" B14" 3" 2/S1 ov �� 0 w w p A. USE RJ MODEL WHERE FLOOR SYSTEM OCCURS ANCHOR BOLT PER SIMPSON 0 D/3 = �i p C) O B. ANCHORS MUST BE CAST IN PLACE (EPDXY ANCHOR BOLT OPTION NOT ALLOWED) J 1 SECTION S1,) DO NOT SCALE ANCHOR BOLT 6" OR 8" CONC. STEM WALL POST INSTALLED SHEAR WALL ANCHORS ONLY. SHEAR WALL SCHEDULE 1" MAX O zQ WOOD PANEL SHEATHING FASTNERS - EDGE NAILINGc FRAMING MEMBER SIZE ANCHOR BOLTS MARK NOTCHING OF ROOF OR FLOOR JOIST Z n- WALL SILL PLATE BOLTO SPACING SHEAR WALL 0 THICKNESS LAYERS (SEENOTEI) (7/16"MIN. CROWN) STUDS �p,T,) 1-3/8 L � D/4 Z APA RATED 7/16" 1 8d @ 6" O.C. 1 1/2" 16 GA. @ 4" O.C. 2x 2x 78- - WALL STUDS Joe U3 U3 U3 3 2-1/4 (SEE FRAMING PLAN) °) z 2-3/4 1-7/8 NO BORING N eh ?� ALLOWED HEAVY HEX 0 HEAD [ j 2x STUDS w O Z o J co 1 SECTION S1,) DO NOT SCALE ANCHOR BOLT 6" OR 8" CONC. STEM WALL POST INSTALLED SHEAR WALL ANCHORS ONLY. SHEAR WALL SCHEDULE STUD SPACING WOOD PANEL SHEATHING FASTNERS - EDGE NAILINGc FRAMING MEMBER SIZE ANCHOR BOLTS MARK GRADE MINIMUM NOMINAL # OF NAILS STAPLES WALL SILL PLATE BOLTO SPACING SHEAR WALL 8" O.C. THICKNESS LAYERS (SEENOTEI) (7/16"MIN. CROWN) STUDS �p,T,) 1-3/8 EMBED. (hef) Z APA RATED 7/16" 1 8d @ 6" O.C. 1 1/2" 16 GA. @ 4" O.C. 2x 2x 78- 4'-0" °7" NOTCHING & HOLf EA HOEDOWN O=m1M BORING OF EXT. C. SEE INTERMEDIATE NAILING SCHED EE SCHEDULE) im 0 OR BEARING WALL D. SEE EPDXY ANCHOR BOLT OPTION ALL SHEATHING HOLE BORINGOFROOF ORFLOOR JOIST STUDS NOTE: BLOCK ALL SHEAR WALL PANEL EE NAILINGSCHEDj EDGES. SEE DETAIL B/S1 DBL TOP PLATE NOTES: MPSON HOEDOWN 1. NAILS TO BE COMMON OR GALV. BOX NAILS ONLY. (GALV. I MODEL EE SCHED) OTTOM PLATE SIZE SCHEDULE STUD SPACING MEMBER D/3 D/4 D/6 2x4 1-1/8 8d @ 12" O.C. 8" O.C. 2x6 1-3/4 1-3/8 1 7/8 24" O.C, 2-3/8 1-3/4 1-1/8 k'5--518 3 2-1/4 1-1/2 °) z 2-3/4 1-7/8 NAILS MUST BE HO I UPPED UH I UMGLtid)..NUN-UALV. t3UX NAILS, SINKERS, ETC. ARE NOT ALLOWED. 2. FOUNDATION SILL PLATE SHALL BE ATTACHED PER DETAIL 3. ALL EXTERIOR WALLS TO BE l U.N.O. 4. � DENOTES A SHEAR WALL 5. LOCATE HOLDOWNS AT CORNERS AND ADJACENT TO DOORMINDOW OPENINGS. (SEE ARCH DRAWINGS) FLOOR SHEATHING �O�� 6. ALL ANCHOR BOLTS TO BE A36/F1554 GRADE 36 (SEE NAILING SCHED) HOLES & NOTCHES IN BEAMS ARE NOT ALLOWED UNLESS WALL STUD OTHERWISE APPROVED IN L STRAPS S 250 S WRITING BY ENGINEER STEEL STRAPS (MIN) NOTCHING OF DOUBLE A SECTION TOP PLATE KS1) DO NOT SCALE CINTERMEDIATE NAILING (FIELD) STUD SPACING MINIMUM PANEL THICKNESS FASTNERS - FIELD NAILING NAILS STAPLES 7/16" MIN. CROWN 16" O.C. 7/16" 8d @ 12" O.C. 8" O.C. 24"O.C. 7/16" 8d @ 6" O.C. 4!'O.C. 24" O.C, 15/32" 8d @ 12" O.C. 8" O.C. Z Z O- 4 i -Z w2 Z W V J _0 1 00 co 0S cc EL o- r a °) z W OR N eh HEAVY HEX 0 HEAD V' V J 00 co Ox W a °) W Z N Z 0 W [ j V cc °=N J co zz W (r J0 < WQQW LU F- 0� Z O Fc N UJLU N U W 11 H LOLO "' 1- X c c D N V O do Z O M a. T PROJECT NO. 220118 SHEET NO. S1 OF ONE