HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00098 - 334 Harvard Ave - Duplex RemodelPermit Inspection Summary Permit Status of (Open) as of Report Date: 05/08/2020 10:36 am Permit Details Permit Number: 11-00098 334 Harvard Ave - Duplex Remodel 334 Harvard Ave Single Family - Remodel Permit Issued Date: 12/03/2014 Permit Inspection Statistics 11Total Inspections Completed: 9Total Inspections Passed: Inspection Pass Rate: 81.82% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 05/25/2011PassTed DyeResidential Framing/Structure Inspection 05/31/2011PassTed DyeResidential Insulation Inspection Insulation good, ready for cover. Post still missing under beam in fridge and pantry area. Inspector Comments: 06/14/2011PassTed DyeResidential Sheetrock/Drywall Inspection Some tape (Most) already on. Searched and found Type X fire code on ceiling.Inspector Comments: 08/30/2011PassPLL ADMINResidential Building Final As per Jon BerryInspector Comments: Electrical 05/31/2011PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 4/11/11 - Approved for cover-northwest bedroom/bathroom, need to seet the romex connectors in the metal box in the bedroom-switch and add outlets in the short walls on both sides of the bedroom door. 5/20/11 - Approved for cover-insulate only-call before sheetrocking-laundry needs dedicated circuit, smoke alarms(3) needed to be installed, AFCI bedrooms required for final inspection, water heater breaker locks required for final. 5/31/11 - Approved for cover-remodeled basement-some existing wires left alone and Scott(owner) did not want to replace them. Inspector Comments: 10/07/2011FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Need to install flex on water heater wire, blank cover missing for light in computer room downstairs, open ground receptacles in the living room downstairs, receptacle covered in wall in living room downstairs, new receptacles need to be tamper resistant type, clean up main panel-cover exposed romex around panel, call for a re-inspect when ready. Inspector Comments: 10/07/2011PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final-remodel.Inspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 11-00098 334 Harvard Ave - Duplex Remodel 334 Harvard Ave Single Family - Remodel Permit Status of (Open) as of Report Date: 05/08/2020 10:36 am Permit Inspection Summary Mechanical 04/11/2011PassPLL ADMINHVAC Rough-in As per Jon Berry HVAC rough upstairs looks good. Separation OK. Will need bath fan for bathroom. Inspector Comments: 08/30/2011PassPLL ADMINHVAC Final Inspection As per Jon BerryInspector Comments: Plumbing 10/12/2011FailDon AllenPlumbing Final Inspection Needs to put a ball valve on the water heater the rest looks ok.Inspector Comments: 11/07/2012PassDon AllenPlumbing Final Inspection Page 2 of 2