Loading...
HomeMy WebLinkAboutSOLAR PANEL PLANS & INFO - 20-00283 - 212 W 3rd N - Stucki - Solar PanelsCONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT PROJECT INFORMATION, VICINITY MAP www.bigdogenergy.com P V - 1 4/27/2020 ALL CONDUIT TO RUN ON EXTERIOROF HOUSE UNLESS OTHERWISE NOTEDOCCUPANCY:R-3CONSTRUCTION TYPE:VBUNSPRINKLEREDALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH THECODE AND THE MANUFACTURES INSTALLATION INSTRUCTIONS.ALL PLACARDS REQUIRED BY NEC 2017 CODE MACHINEPRINTED LETTERS IN A CONTRASTING COLOR TO THE PLACARD.LIQUID TIGHT FLEXIBLE CONDUIT SHALL BE SUNLIGHTRESISTANT. ELECTRICAL INSTALLATION WILL COMPLY WITH NEC2017 CODE. ALL SOLAR MODULES EQUIPMENT AND METALLICCOMPONENTS ARE TO BE BONDED. ALL PLUMBING ANDMECHANICAL ROOF VENTS TO CLEAR FROM PHOTOVOLTAICARRAY, OR EXTEND ABOVE SOLAR PANELS. SOLARPHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIALSTRUCTURE. DESIGN COMPLYING WITH THE IBC 2015 CODEAND ALL LOCAL ORDINANCES AND POLICIES. THE PROJECT HASBEEN DESIGNED TO WITHSTAND A MINIMUM 110 MPH WINDLOAD. THE SYSTEM WILL NOT BE INTERCONNECTED UNTILAPPROVAL FROM THE LOCAL JURISDICTION AND A UTILITY ISOBTAINED. IF THE MAIN SERVICE PANEL DOES NOT HAVEVERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTORSRESPONSIBILITY TO INSTALL SUPPLEMENTAL GROUNDINGELECTRODE. EACH MODULE WILL BE GROUNDED USING THESUPPLIED CONNECTION POINTS IDENTIFIED ON THE MODULEAND THE MANUFACTURERS INSTALLATION INSTRUCTIONS. ALADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCEWITH OSHA REGULATIONS. PROPER ACCESS AND WORKINGCLEARANCE WILL BE PROVIDED "WARNING: PV POWERSOURCE" TO BE PLACED EVERY 10 FT.RAPID SHUTDOWN NOT REQUIRED. DC IS LESS THAN 5' INSIDEBUILDING.GFCI PROTECTION IN INVERTER.MSPSUBACDCSLCMINVJBCBFMC M A I N S E R V I C E P A N E L S U B S E R V I C E P A N E L A C D I S C O N N E C T D C D I S C O N N E C T S O L A R L O A D C E N T E R M O N I T O R I N G M E T E R I N V E R T E R J U N C T I O N B O X C O M B I N E R B O X F L E X I B L E M E T A L L I C C O N D U I T ( E ) ( N ) E X T I N T E M T R M T V O C V M P I S C N T S E X I S T I N G N E W E X T E R I O R I N T E R I O R E L E C T R I C A L M E T A L L I C T U B I N G R I G I D M E T A L L I C T U B I N G V O L T A G E O P E N C I R C U I T V O L T A G E A T M A X . P O W E R S H O R T C I R C U I T C U R R E N T N O T T O S C A L E I M P C U R R E N T A T M A X . P O W E R A L L W O R K T O C O M P L Y W I T H T H E F O L L O W I N G C O D E : N E C 2 0 1 7 C O D E I B C 2 0 1 5 C O D E P V - 1 P R O J E C T I N F O R M A T I O N , V I C I N I T Y M A P P V - 2 S I T E P L A N , A E R I A L V I E W P V - 3 E L E C T R I C A L L I N E D I A G R A M A N D N O T E S P V - 4 R E Q U I R E D S I G N A G E ADDITIONAL NOTES P L A N S E T L E G E N D A B B R E V I A T I O N S P R O J E C T I N F O R M A T I O N V I C I N I T Y M A P A P P L I C A B L E C O D E S S H E E T I N D E X 1 0 X 3 1 5 W J I N K O P H O T O V O L T A I C M O D U L E S 1 X 3 8 0 0 W S O L A R E D G E S Y S T E M S I Z E : 3 , 1 5 0 W D C S T C A R R A Y A R E A : 1 7 0 S F C L Y D E S T U C K I 2 1 2 W 3 R D N R E X B U R G , I D 8 3 4 4 0 2 0 8 - 3 1 3 - 0 8 8 7 CLYDE STUCKI 212 W 3RD N REXBURG, ID 83440 208-313-0887 Big Dog Renewable Electric Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ N HOUSE MTRMSPAC INV45' TRENCH S H E D CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT SITE PLAN, AERIAL VIEW www.bigdogenergy.com P V - 2 SITE PLAN A E R I A L V I E W S C A L E : N T S S C A L E : 1 " = 3 0 ' - 0 " TOTAL # OF PANELS10 A B B R E V I A T I O N S I N V M S P A C I N V E R T E R M A I N S E R V I C E P A N E L A C D I S C O N N E C T M T R M E T E R Big Dog Renewable Electric Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ 4/27/2020 CLYDE STUCKI 212 W 3RD N REXBURG, ID 83440 208-313-0887 ROOF TYPE:METAL ELECTRICAL E Q U I P M E N T C A L L O U T S SOLADECK MO D E L 0 7 8 3 - 4 1 J U N C T I O N B O X / R O O F PENETRATION, 6 0 0 V 3.8.kW INVERT E R U N G R O U N D E D SOLAREDGE S E 3 8 0 0 H - U S (240V) INVERTE R 240VAC, 16A, N E M A 3 R , U L L I S T E D , (W/ INTEGRATE D D C D I S C O N N E C T ) WITH INTEGRA T E D G F P , W / I N T E G R A T E D A F P 200A MAIN SER V I C E P A N E L (W/ BIDIRECTIO N A L U T I L I T Y M E T E R ) SOLAREDGE O P T I M I Z E R P 3 7 0 O N E P E R P A N E L AC DISCONNE C T 240VAC, 60A F U S E D N E M A 3 R , U L L I S T E D W / 4 0 A FUSES 123 B 3,150W TOTAL SOLAR ARRAY10 JINKO 315W MODULESARRAY 110 MODULES CONNECTED IN 10 MODULE SERIES @ INVERTERCD A_~B 2 1 0 M O D U L E S I N S E R I E S 1 D M P P T 2 S T R I N G 1 T I L T : 2 2 ° A Z I M U T H : 1 8 0 ° O N E P E R P A N E L A 3 WIRE AND CONDUIT CALLOUTS(2) #10 AWG PV/RHW-2 IN FREE AIR(1) #6 AWG BARE COPPER GND IN FREE AIR(2) #10 AWG THWN-2(1) #10 AWG THWN-2 GND IN 34" EMT/FMC(2) #6 AWG THWN-2(1) #10 AWG THWN-2 GND IN 34" EMTENGNNGL1L2L1L23ENNGC200A M O D U L E : J I N K O 3 1 5 W V o c = 4 6 . 1 V I s c = 8 . 8 7 A V m p = 3 7 . 6 V I m p = 8 . 3 8 A A L L M O D U L E S W I L L B E G R O U N D E D I N A C C O R D A N C E W I T H C O D E A N D T H E M A N U F A C T U R E R ' S I N S T A L L A T I O N I N S T R U C T I O N S . T E R M I N A L S O F T H E D I S C O N N E C T I N G M E A N S M A Y B E E N E R G I Z E D I N T H E O P E N P O S I T I O N . N E C A R T I C L E 6 9 0 . 1 7 TAP 27.3' OR LESS ELECTRICAL SINGLE LINE DIAGRAM CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT SINGLE LINE DIAGRAM P V - 3 S C A L E : N T S E L E C T R I C A L N O T E S R A C K I N G & M O D U L E S A R E G R O U N D E D V I A A C O N T I N U O U S # 6 A W G C O P P E R C O N D U C T O R C O N N E C T E D W / W E E B S - M O D U L E S A R E F A C T O R Y P R O V I D E D W / 2 T H R E A D E D H O L E S T O F A C I L I T A T E L A N D I N G O F T H E L U G S A L L E Q U I P M E N T S H A L L B E P R O P E R L Y G R O U N D E D A N D B O N D E D I N A C C O R D A N C E W I T H A R T I C L E 2 5 0 . A L L C I R C U I T S C O N N E C T E D T O M O R E T H A N O N E S O U R C E S H A L L H A V E O V E R C U R R E N T D E V I C E S L O C A T E D S O A S T O P R O V I D E O V E R C U R R E N T P R O T E C T I O N F R O M A L L S O U R C E S 6 9 0 . 9 ( A ) www.bigdogenergy.com Big Dog Renewable Electric Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ 4/27/2020 CLYDE STUCKI 212 W 3RD N REXBURG, ID 83440 208-313-0887 1 . P V A R R A Y S A R E P E R S I N G L E L I N E . 2 . P V A R R A Y W I R I N G T O J U N C T I O N I S # 1 0 A W G U S E 2 W / F I E L D I N S T A L L E D M C C O N N E C T O R S T O I N T E R F A C E W / M O D U L E S . 3 . P V A R R A Y C O M B I N E R / J U N C T I O N B O X P R O V I D E S T R A N S I T I O N F R O M A R R A Y W I R I N G T O C O N D U I T W I R I N G . 4 . U S E U F E R G R O U N D E L E C T R O D E S Y S T E M F R O M I N V E R T E R T O E X I S T I N G M A I N S E R V I C E G R O U N D E L E C T R O D E P E R N . E . C . 2 5 0 . 5 8 . 5 . G R O U N D E L E C T R O D E C O N D U C T O R F R O M I N V E R T E R T O G R O U N D E L E C T R O D E T O B E M I N I M U M P R O T E C T I O N O F B A R E A R M O R S H E A T H E D C A B L E F O R A L L C O N D U C T O R S I Z E S . 6 . A L L G R O U N D C O N N E C T E D T O M A I N S E R V I C E G R O U N D I N M A I N S E R V I C E P A N E L . 7 . C O N N E C T O R S S H A L L B E P O L A R I S O R E U R O S T R I P I T C O N N E C T O R S . 8 . I N V E R T E R S H A L L B E P E R S I N G L E L I N E , S E E A T T A C H E D C U T S H E E T . 9 . I N V E R T E R I S P E R S I N G L E L I N E . 1 0 . A C D I S C O N N E C T S H A L L B E P E R S I N G L E L I N E . 1 1 . E Q U I P M E N T G R O U N D I N G C O N D U C T O R S O N A C A N D D C S I D E S I Z E D A C C O R D I N G T O N . E . C . 6 9 0 . 1 2 . P O L E O F P V A R R A Y R E F E R E N C E D T O G R O U N D A T T H E I N V E R T E R I N S I N G L E L I N E . 1 3 . A L L C O N D U C T O R S S H A L L B E 6 0 0 V , 9 0 C S T A N D A R D C O P P E R . A L L C O N D U C T O R S I N C O N D U I T S H A L L B E T H W N - 2 . 1 4 . M A X I M U M D C V O L T A G E D R O P S H A L L B E 2 . 5 % 1 5 . A L L C O N D U C T O R S S H A L L B E I N C O N D U I T U N L E S S O T H E R W I S E N O T E D . 1 6 . A L L W O R K T O C O M P L Y W I T H N E C 2 0 1 7 C O D E . 1 7 . D C A R R A Y C O N D U C T O R S A R E T O R E M A I N O U T S I D E O F B U I L D I N G P R I O R T O F U S I B L E C O M B I N E R B O X O R F U S I B L E D C D I S C O N N E C T M E A N S . 1 8 . E X A C T C O N D U I T R U N L O C A T I O N S S U B J E C T T O C H A N G E . 1 9 . 3 . 0 P S F M A X ( . 5 P S F F R O M R A C K I N G , 2 . 5 P S F F R O M M O D U L E S ) D E A D L O A D C O N T R I B U T E D F R O M S O L A R A R R A Y . 2 0 . A R C F A U L T I N S T A L L E D A T I N V E R T E R O R I N C O M B I N E R B O X . 2 1 . D C G R O U N D F A U L T P R O T E C T I O N I N T E G R A T E D I N I N V E R T E R . 2 2 . P O I N T O F C O N N E C T I O N B R E A K E R T O B E L O C A T E D O P P O S I T E E N D O F B U S B A R F R O M M A I N U N L E S S O T H E R W I S E N O T E D . 2 3 . A N Y U N D E R G R O U N D W I R I N G M E T H O D S W I L L C O M P L Y W I T H N E C 3 0 0 . 5 ( J ) , 3 0 0 . 7 ( B ) , 3 5 2 . 4 4 , A N D O T H E R S E C T I O N S O F C H A P T E R 3 A S A P P L I C A B L E . 2 4 . A N Y E X P O S E D P V C C O N D U I T S H A L L C O M P L Y W I T H N E C 3 5 2 . 1 0 2 5 . A L L P V S Y S T E M D C C I R C U I T S R U N I N S I D E A B U I L D I N G S H A L L B E C O N T A I N E D I N A M E T A L R A C E W A Y I N A C C O R D A N C E T O N E C 6 9 0 . 3 1 ( G ) 2 6 . C O M P L I E S W I T H 7 0 5 . 1 2 ( B ) ( 2 ) ( 3 ) ( B ) 2 7 . S U P P L Y S I D E C O N N E C T I O N W I T H L I S T E D I N S U L A T I O N P I E R C I N G C O N N E C T O R S I N A C C O R D A N C E W I T H 7 0 5 . 1 2 ( A ) A N D 2 3 0 . 8 2 2 8 . C O N N E C T I O N A T P A N E L S E C O N D A R Y S E R V I C E L O C A T I O N CONTRACTOR INFORMATIONDESIGNED BYSOLAR PHOTOVOLTAIC SYSTEMDATEISSUED FOR: PERMIT REQUIRED SIGNAGE www.bigdogenergy.com P V - 4 REQUIRED SIGNAGE1. PROVIDE A PLACARD WITH THE FOLLOWING WORKING IN 14"HIGH LETTERING PER NEC 690-17.2. LABEL FOR SOLAR AC DISCONNECT:FIRE DEPARTMENT REQUIRED SIGNAGE3. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM OF 38" HIGHLETTERING, IN ARIAL FONT (NON-BOLD), WITH CAPITAL LETTERS,WHITE ON RED BACKGROUND AND A REFLECTIVE, WEATHERRESISTANT MATERIAL.AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN WITH THEFOLLOWING WORDING:WARNING:ELECTRICAL SHOCK HAZARD.DO NOT TOUCH TERMINALS. TERMINALS ONBOTH THE LINE AND LOAD SIDES MAY BEENERGIZED IN THE OPEN POSITION."SOLAR AC DISCONNECT" 6 . R E F L E C T I V E P L A C A R D A T S E R V I C E S T A T I N G : 7 . A T S E R V I C E D I S C O N N E C T : P H O T O V O L T A I C S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N R A P I D S H U T D O W N D I S C O N N E C T 4/27/2020 CLYDE STUCKI 212 W 3RD N REXBURG, ID 83440 208-313-0887 Big Dog Renewable Electric Energy Contractor Lic #017916 620 Pheasant Ridge Dr Chubbuck, ID 83202 208-242-3352 T 208-232-5935 F X____________________ WARNINGDUAL POWER SUPPLYSOURCES: UTILITY GRIDAND PV SOLAR ELECTRIC SYSTEMTHE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER IF THEMAIN SERVICE DISCONNECT IS OPERABLE WITH THE SERVICEPANEL CLOSED.4. LABELS TO BE INSTALLED ON FACE OF THE UTILITY ACDISCONNECT:CUSTOMER OWNEDONSITE POWER GENERATIONSYSTEM DISCONNECT5. LABEL INSTALLATION AT INTERCONNECT BREAKER:WARNING:INVERTER CONNECTION.DO NOT RELOCATE THISOVERCURRENT DEVICE. www.jinkosolar.com MCS KEY FEATURES High module conversion efficiency (up to 16.49%), through innovative manufacturing technology. JKM320M-72 Positive power tolerance of 0/+3% 300-320 Watt MONO CRYSTALLINE MODULE ISO9001:2008aISO14001:2004aOHSAS18001 certified factory. IEC61215aIEC61730 certified products. High Efficiency: Advanced glass and solar cell surface texturing allow for excellent performance in low-light environments. Low-light Performance: Certified to withstand: wind load (2400 Pascal) and snow load (5400 Pascal). Severe Weather Resilience: High salt mist and ammonia resistance certified by TUV NORD. Durability against extreme environmental conditions: LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty 25 Year Linear Power Warranty 80.2% 90.% 95.% 97% 100% 15 12 25 yearsGu a r a n t e e d P o w e r P e r f o r m a n c e linear performance warranty Standard performance warrantyAddition a l v a l u e f r o m J i n k o S o l a r ’ s l i n e a r w a r r a n t y Current-Voltage & Power-Voltage Curves (300W) Temperature Dependence of Isc,Voc,Pmax The company reserves the final right for explanation on any of the information presented hereby. EN-MKT-320M_v1.0_rev2015 Engineering Drawings SPECIFICATIONS Mechanical Characteristics CellTypeMono-crystalline156×156mm(6inch) No.ofcells 72(6×12)  Dimensions1956×992×40mm(77.01×39.05×1.57inch) Weight26.5kg(58.4lbs.) FrontGlass4.0mm,HighTransmission,LowIron,TemperedGlass Frame AnodizedAluminiumAlloy JunctionBox IP67Rated OutputCables Electrical Performance & Temperature Dependence Packaging Configuration (Twoboxes=Onepallet) 25pcs/box,50pcs/pallet,600pcs/40'HQContainer Isc Voc Pmax 450 1 2 3 4 5 6 7 8 9 10 50510152025 30 350 40 0 48 96 144 192 240 288 336 ²TÜV1×4.0mm,Length:900mm Irradiance1000W/m2 AM=1.5STC: Irradiance800W/m2 AM=1.5NOCT: Powermeasurementtolerance:±3%* WindSpeed1m/s ModuleType MaximumPower(Pmax) MaximumPowerVoltage(Vmp) MaximumPowerCurrent(Imp) Open-circuitVoltage(Voc) Short-circuitCurrent(Isc) ModuleEfficiencySTC(%) OperatingTemperature(℃) Maximumsystemvoltage Maximumseriesfuserating Powertolerance TemperaturecoefficientsofPmax TemperaturecoefficientsofVoc TemperaturecoefficientsofIsc Nominaloperatingcelltemperature(NOCT) -40℃~+85℃ 1000VDC (IEC) 15A 0~+3% -0.40%/℃ -0.29%/℃ 0.05%/℃ 45±2℃ JKM300M 300Wp 37.0V 8.11A 45.5V 8.64A 15.46% JKM305M 305Wp 37.2V 8.20A 45.7V 8.72A 15.72% JKM310M 310Wp 37.4V 8.29A 45.9V 8.80A 15.98% 226Wp 230Wp 6.39A 6.47A 35.3V 35.5V 43.2V 43.5V 222Wp 6.32A 35.1V 42.8V 6.96A 7.01A 7.06A JKM315M 315Wp 37.6V 8.38A 46.1V 8.87A 16.23% 234Wp 35.8V 6.54A 43.9V 7.10A STC NOCT JKM320M 320Wp 37.8V 8.47A 46.4V 8.98A 16.49% 238Wp 35.9V 6.62A 44.1V 7.15A STC NOCTSTC NOCT STC NOCT STC NOCT CellTemperature25°C AmbientTemperature20°C 19 5 6 XXXXXXXXXXXXXXXXXXX 992 40 ͥͥͥͥͥͥͥͥͥͥͥͥͥͥͥͥͥͥͥͥ 100 86 0 13 6 0 L 942 û Installing Holes ü ú Label Junction box Cathode -+ Anode Connector Grounding Holes A A ü 4.5 14 95.5 70 70 3 8 û ͥͥͥͥͥͥͥͥͥͥͥͥͥͥͥͥͥͥͥͥ ú A-A 35 40 2-Ø4 IN V E R T E R S www.solaredge.us 12-25 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 UL1741 SA certified, for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytic capacitors Built-in module-level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT  Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA Max. AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)-3 -3 ---Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 3 3 3 Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current 208V -16 -24 ---A Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A GFDI Threshold 1 AUtility Monitoring, Islanding Protection, C o u nt r y C o nfi g u ra b l e T h r e s h o l d s Yes INPUT  Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --- Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V -9 -13.5 --- Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption < 2.5 WADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional)Revenue Grade Data, ANSI C12.20 Optional(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS  AC Output Conduit Size / AWG Range 3/4” minimum / 14-6 AWG 3/4” minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4” minimum / 1-2 strings / 14-6 AWG 3/4” minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Natural convection Operating Temperature Range -13 to +140 / -25 to +60(3) (-40˚F / -40˚C option)(4)˚F / ˚C Protection Rating NEMA 3R (Inverter with Safety Switch) Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US (1) For other regional settings please contact SolarEdge support (2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf(4) -40 version P/N: SExxxxH-US000NNU4 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2018/V01/ENG NAM. Subject to change without notice. PO W E R O P T I M I Z E R SolarEdge Power Optimizer Module Add-On For North America P320 / P370 / P400 / P405 / P505 Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Compliant with arc fault protection and rapid shutdown NEC requirements (when installed as part of the SolarEdge system) Module-level voltage shutdown for installer and firefighter safety PV power optimization at the module-level www.solaredge.usUSA-CANADA-GERMANY-UK-ITALY-THE NETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-FRANCE-BELGIUM-TURKEY-INDIA-BULGARIA-ROMANIA-HUNGARY- SWEDEN-SOUTH AFRICA-POLAND-CZECH REPUBLIC OPTIMIZER MODEL (typical module compatibility) P320 (for high-power 60-cell modules) P370 (for higher-power 60 and 72-cell modules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) P505 (for highercurrent modules) INPUT Rated Input DC Power(1)320 370 400 405 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 125 83 Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 14 Adc Maximum DC Input Current 13.75 12.63 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H)128 x 152 x 28 / 5 x 5.97 x 1.1 128 x 152 x 36 / 5 x 5.97 x 1.42 128 x 152 x 50 / 5 x 5.97 x 1.96 128 x 152 x 59 / 5 x 5.97 x 2.32 mm / in Weight (including cables)630 / 1.4 750 / 1.7 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(2) Output Wire Type / Connector Double Insulated; MC4 Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ft Operating Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. (2) For other connector types please contact SolarEdge SolarEdge Power Optimizer Module Add-On for North America P320 / P370 / P400 / P405 / P505 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(3)(4) SINGLE PHASE HD-WAVE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power Optimizers) P320, P370, P400 8 10 18 P405 / P505 6 8 14 Maximum String Length (Power Optimizers)25 25 50(5) Maximum Power per String 5700 (6000 with SE7600H-US, SE10000H-US) 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2018/V01/ENG NAM. Subject to change without notice. (3) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf.(4) It is not allowed to mix P405/P505 with P320/P370/P400/P600/P700/P800 in one string.(5) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL MANUFACTURER SPEC SHEET - RAIL