HomeMy WebLinkAboutRESCHECK - 20-00255 - Lots 20-25 on Block 6 - Summerfield 6 Plex.pdfREScheck Software Version 4.6.5
Compliance Certificate
Project Kartchner 6 Plex
Energy Code:2015 IECC
Location:Idaho Falls, Idaho
Construction Type:Single-family
Project Type:New Construction
Conditioned Floor Area:10,140 ft2
Glazing Area 13%
Climate Zone:6 (7918 HDD)
Permit Date:
Construction Site:Owner/Agent:
Sprinter Heating & Hydronics
Designer/Contractor:
Mechanical Compliance Solutions
Mechanical Compliance Solutions
4181 Aschli lane
Idaho Falls, ID 83406
208-881-3243
1sgmiller@cableone.net
Permit Number:
Compliance: Passes using UA trade-off
1.3% Better Than Code Maximum UA:1319 Your UA:1302
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Wall 1: Wood Frame, 16" o.c.2,808 21.0 0.0 0.057 129
Door 1: Solid 252 0.140 35
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 300 0.320 96
Wall 2: Wood Frame, 16" o.c.1,395 21.0 0.0 0.057 78
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 25 0.320 8
Wall 3: Wood Frame, 16" o.c.2,808 21.0 0.0 0.057 110
Door 1: Solid 126 0.140 18
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 744 0.320 238
Wall 4: Wood Frame, 16" o.c.1,395 21.0 0.0 0.057 78
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 25 0.320 8
Floor 1: All-Wood Joist/Truss:Over Outside Air 1,984 38.0 0.0 0.026 52
Floor 3: Slab-On-Grade:Unheated
Insulation depth: 5.4'
440 17.9 0.643 283
Ceiling 1: Flat Ceiling or Scissor Truss 6,482 50.0 0.0 0.026 169
Project Title: Kartchner 6 Plex
Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Kartchner 6 Plex.rck Page 1 of 2
04/21/20Report date:
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Notes:
Job Number: Kartchnet 6 Plex
INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE
VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID.
Project Title: Kartchner 6 Plex
Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Kartchner 6 Plex.rck Page 2 of 2
04/21/20Report date: