HomeMy WebLinkAboutRESCHECK - 20-00255 - Lots 20-25 on Block 6 - Summerfield 6 Plex.pdfREScheck Software Version 4.6.5 Compliance Certificate Project Kartchner 6 Plex Energy Code:2015 IECC Location:Idaho Falls, Idaho Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:10,140 ft2 Glazing Area 13% Climate Zone:6 (7918 HDD) Permit Date: Construction Site:Owner/Agent: Sprinter Heating & Hydronics Designer/Contractor: Mechanical Compliance Solutions Mechanical Compliance Solutions 4181 Aschli lane Idaho Falls, ID 83406 208-881-3243 1sgmiller@cableone.net Permit Number: Compliance: Passes using UA trade-off 1.3% Better Than Code Maximum UA:1319 Your UA:1302 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Wall 1: Wood Frame, 16" o.c.2,808 21.0 0.0 0.057 129 Door 1: Solid 252 0.140 35 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 300 0.320 96 Wall 2: Wood Frame, 16" o.c.1,395 21.0 0.0 0.057 78 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 25 0.320 8 Wall 3: Wood Frame, 16" o.c.2,808 21.0 0.0 0.057 110 Door 1: Solid 126 0.140 18 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 744 0.320 238 Wall 4: Wood Frame, 16" o.c.1,395 21.0 0.0 0.057 78 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 25 0.320 8 Floor 1: All-Wood Joist/Truss:Over Outside Air 1,984 38.0 0.0 0.026 52 Floor 3: Slab-On-Grade:Unheated Insulation depth: 5.4' 440 17.9 0.643 283 Ceiling 1: Flat Ceiling or Scissor Truss 6,482 50.0 0.0 0.026 169 Project Title: Kartchner 6 Plex Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Kartchner 6 Plex.rck Page 1 of 2 04/21/20Report date: Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Notes: Job Number: Kartchnet 6 Plex INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Project Title: Kartchner 6 Plex Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Kartchner 6 Plex.rck Page 2 of 2 04/21/20Report date: