Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LOAD SHORT FORM - 20-00255 - Lots 20-25 on Block 6 - Summerfield 6 Plex.pdf
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 1 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Load Short Form 4/20/2020Date:Entire House Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Information InfiltrationClgHtg SimplifiedMethod90-7Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1577Design TD (°F) H-Daily range 5030Inside humidity (%) -2935Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref.n/a Coil n/a AHRI ref.n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0 Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Unit B AH 1690 20752 11718 665 767 Unit A AH 1690 27068 13044 665 767 Unit C AH 1690 20752 11718 665 767 Unit D AH 1690 20586 11682 665 665 Unit E AH 1690 20752 11718 665 767 Unit F AH 1690 26938 13148 665 665 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 2 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Entire House 10140 136849 73028 3990 4398 Other equip loads 22422 4268 Equip. @ 0.95 RSM 73122 Latent cooling 730 TOTALS 10140 159271 73852 3990 4398 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 3 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Load Short Form 4/20/2020Date:Unit A AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Information InfiltrationClgHtg SimplifiedMethod90-7Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1577Design TD (°F) H-Daily range 5030Inside humidity (%) -2935Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Day & Night Make Day & Night Trade DAY & NIGHT Trade 13 SEER N SERIES R410A AC Model N95ESN0401410AA2 Cond N4A324AKN20 AHRI ref 4705245 Coil END4X24L14A1++TDR AHRI ref 9386153 Efficiency 96 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh21620 Heating output Btuh33345 Latent cooling Btuh0 Temperature rise °F54 Total cooling Btuh21620 Actual air flow cfm665 Actual air flow cfm767 Air flow factor cfm/Btuh0.025 Air flow factor cfm/Btuh0.059 Static pressure in H2O0.90 Static pressure in H2O0.90 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Mech 39 0 0 0 0 Pantry A 27 0 0 0 0 Powder A 31 0 0 0 0 Kit/din/Family A 629 12828 7667 315 451 Bedroom 2 A 142 4160 995 102 59 Bedroom 3 A 123 3346 897 82 53 3A WIC 29 387 84 10 5 Bath A 61 1311 201 32 12 Master A 252 3642 2301 89 135 M Bath A 107 1243 693 31 41 M WIC A 50 151 205 4 12 Laundry A 38 0 0 0 0 Stairs/Hall A 162 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 4 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Unit A AH 1690 27068 13044 665 767 Other equip loads 2895 551 Equip. @ 0.95 RSM 12861 Latent cooling 0 TOTALS 1690 29963 12861 665 767 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 5 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Load Short Form 4/20/2020Date:Unit B AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Information InfiltrationClgHtg SimplifiedMethod90-7Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1577Design TD (°F) H-Daily range 5030Inside humidity (%) -2935Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Day & Night Make Day & Night Trade DAY & NIGHT Trade 13 SEER N SERIES R410A AC Model N95ESN0401410AA2 Cond N4A324GKN20 AHRI ref 4705245 Coil END4X24L14A1++TDR AHRI ref 9386153 Efficiency 96 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh21620 Heating output Btuh33345 Latent cooling Btuh0 Temperature rise °F54 Total cooling Btuh21620 Actual air flow cfm665 Actual air flow cfm767 Air flow factor cfm/Btuh0.032 Air flow factor cfm/Btuh0.065 Static pressure in H2O0.90 Static pressure in H2O0.90 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Pantry B 27 0 0 0 0 Powder B 30 0 0 0 0 Kit/Din/Family B 629 9951 6632 319 434 Bedroom 2B 142 2700 866 87 57 Bedroom 3 B 123 3569 924 114 60 Bath B 61 301 103 10 7 Master B 252 2426 2201 78 144 M Bath B 107 1243 699 40 46 M WIC B 50 151 207 5 14 Laundry B 38 0 0 0 0 Stairs/Hall B 162 0 0 0 0 3 B WIC 29 413 86 13 6 Mech B 39 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 6 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Unit B AH 1690 20752 11718 665 767 Other equip loads 4158 791 Equip. @ 0.95 RSM 11834 Latent cooling 0 TOTALS 1690 24910 11834 665 767 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 7 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Load Short Form 4/20/2020Date:Unit C AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Information InfiltrationClgHtg SimplifiedMethod90-7Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1577Design TD (°F) H-Daily range 5030Inside humidity (%) -2935Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Day & Night Make Day & Night Trade DAY & NIGHT Trade 13 SEER N SERIES R410A AC Model N95ESN0401410AA2 Cond N4A324GKN20 AHRI ref 4705245 Coil END4X24L14A1++TDR AHRI ref 9386153 Efficiency 96 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh21620 Heating output Btuh33345 Latent cooling Btuh0 Temperature rise °F54 Total cooling Btuh21620 Actual air flow cfm665 Actual air flow cfm767 Air flow factor cfm/Btuh0.032 Air flow factor cfm/Btuh0.065 Static pressure in H2O0.90 Static pressure in H2O0.90 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Mech C 39 0 0 0 0 Bedroom 2 C 142 2700 866 87 57 Pantry C 27 0 0 0 0 3 C WIC 29 413 86 13 6 Powder C 31 0 0 0 0 Kit/Din/Family C 629 9951 6632 319 434 Bedroom 3 C 123 3569 924 114 60 Bath C 61 301 103 10 7 Master C 252 2426 2201 78 144 M Bath C 107 1243 699 40 46 M WIC C 50 151 207 5 14 Laundry C 38 0 0 0 0 Stairs/Hall C 162 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 8 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Unit C AH 1690 20752 11718 665 767 Other equip loads 4160 792 Equip. @ 0.95 RSM 11834 Latent cooling 0 TOTALS 1690 24912 11834 665 767 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 9 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Load Short Form 4/20/2020Date:Unit D AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Information InfiltrationClgHtg SimplifiedMethod90-7Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1577Design TD (°F) H-Daily range 5030Inside humidity (%) -2935Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Day & Night Make Day & Night Trade DAY & NIGHT Trade 13 SEER N SERIES R410A AC Model N95ESN0401410AA2 Cond N4A324GKN20 AHRI ref 4705245 Coil END4X24L14A1++TDR AHRI ref 9386153 Efficiency 96 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh21620 Heating output Btuh33345 Latent cooling Btuh0 Temperature rise °F54 Total cooling Btuh21620 Actual air flow cfm665 Actual air flow cfm665 Air flow factor cfm/Btuh0.032 Air flow factor cfm/Btuh0.057 Static pressure in H2O0.90 Static pressure in H2O0.90 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Mech D 39 0 0 0 0 Bedroom 2 D 142 2620 846 85 48 Bedroom 3 D 123 3466 901 112 51 Pantry D 27 0 0 0 0 Powder D 30 0 0 0 0 Kit/Din/Family D 629 9951 6632 321 378 Bath D 61 261 93 8 5 Master D 252 2367 1815 76 103 M Bath D 107 1243 699 40 40 M WIC D 50 118 53 4 3 Laundry D 38 214 572 7 33 Stairs/Hall D 162 0 0 0 0 3 D WIC 29 347 71 11 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 10 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Unit D AH 1690 20586 11682 665 665 Other equip loads 4158 791 Equip. @ 0.95 RSM 11800 Latent cooling 0 TOTALS 1690 24744 11800 665 665 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 11 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Load Short Form 4/20/2020Date:Unit E AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Information InfiltrationClgHtg SimplifiedMethod90-7Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1577Design TD (°F) H-Daily range 5030Inside humidity (%) -2935Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Day & Night Make Day & Night Trade DAY & NIGHT Trade 13 SEER N SERIES R410A AC Model N95ESN0401410AA2 Cond N4A324GKN20 AHRI ref 4705245 Coil END4X24L14A1++TDR AHRI ref 9386153 Efficiency 96 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh21620 Heating output Btuh33345 Latent cooling Btuh0 Temperature rise °F54 Total cooling Btuh21620 Actual air flow cfm665 Actual air flow cfm767 Air flow factor cfm/Btuh0.032 Air flow factor cfm/Btuh0.065 Static pressure in H2O0.90 Static pressure in H2O0.90 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Mech E 39 0 0 0 0 Laundry E 38 0 0 0 0 Master E 252 2426 2201 78 144 M Bath E 107 1243 699 40 46 M WIC E 50 151 207 5 14 Kit/Din/Family E 629 9951 6632 319 434 Pantry E 27 0 0 0 0 Powder E 30 0 0 0 0 Bedroom 2 E 142 2700 866 87 57 Bedroom 3 E 123 3569 924 114 60 Bath E 61 301 103 10 7 3 E WIC 29 413 86 13 6 Stairs/Hall E 162 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 12 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Unit E AH 1690 20752 11718 665 767 Other equip loads 4158 791 Equip. @ 0.95 RSM 11834 Latent cooling 0 TOTALS 1690 24910 11834 665 767 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 13 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Load Short Form 4/20/2020Date:Unit F AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Information InfiltrationClgHtg SimplifiedMethod90-7Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1577Design TD (°F) H-Daily range 5030Inside humidity (%) -2935Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Day & Night Make Day & Night Trade DAY & NIGHT Trade 13 SEER N SERIES R410A AC Model N95ESN0401410AA2 Cond N4A324GKN20 AHRI ref 4705245 Coil END4X24L14A1++TDR AHRI ref 9386153 Efficiency 96 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh21620 Heating output Btuh33345 Latent cooling Btuh0 Temperature rise °F54 Total cooling Btuh21620 Actual air flow cfm665 Actual air flow cfm665 Air flow factor cfm/Btuh0.025 Air flow factor cfm/Btuh0.051 Static pressure in H2O0.90 Static pressure in H2O0.90 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Mech F 39 0 0 0 0 Laundry F 38 0 0 0 0 Stairs/Hall F 162 0 0 0 0 Pantry F 27 0 0 0 0 Powder F 30 0 0 0 0 Kit/Din/Family F 629 12828 7758 317 392 Bedroom 2 F 142 4091 987 101 50 Bedroom 3 F 123 3292 890 81 45 3 F WIC 29 381 83 9 4 Bath F 61 1311 203 32 10 Master F 252 3642 2322 90 117 M Bath F 107 1243 699 31 35 M WIC F 50 151 207 4 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 14 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Unit F AH 1690 26938 13148 665 665 Other equip loads 2893 551 Equip. @ 0.95 RSM 12959 Latent cooling 0 TOTALS 1690 29832 12959 665 665 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 1 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Building Analysis 4/20/2020Date:Entire House Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude:Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing DoorsCeilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 21.7345695.0Walls 16.92685124.5Glazing 7.11130729.9Doors 6.299441.5Ceilings 8.4133031.91.9Floors 19.7313913.7Infiltration 6.09484Ducts 00Piping 00Humidification 14.122422Ventilation0Adjustments 100.0159271Total Cooling Walls Glazing Doors CeilingsOtherInfiltrationDucts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 4.333350.5Walls 39.13020627.6Glazing 3.527427.3Doors 7.154580.8Ceilings 0.21250.0Floors 4.132010.4Infiltration 2.62041Ducts 5.54268Ventilation 33.525920Internal gains 00Blower 0Adjustments 100.077296Total Latent Cooling Load = 730 Btuh Overall U-va lue = 0.0 57 Btuh/ft²-°F Data entries checked. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 2 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Building Analysis 4/20/2020Date:Unit A AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude:Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 26.077805.0Walls 16.3488424.5Glazing 6.3188529.9Doors 5.516571.5Ceilings 8.324882.12.1Floors 22.768063.7Infiltration 5.21568Ducts 00Piping 00Humidification 9.72895Ventilation0Adjustments 100.029963Total Cooling Walls Glazing Doors CeilingsOtherInfiltrationDucts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 5.57510.5Walls 40.8555027.9Glazing 3.44577.3Doors 6.79100.8Ceilings 0.2210.0Floors 5.16940.4Infiltration 2.5342Ducts 4.1551Ventilation 31.84320Internal gains 00Blower 0Adjustments 100.013595Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 60 Btuh/ft²-°F Data entries checked. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 3 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Building Analysis 4/20/2020Date:Unit B AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude:Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 19.147525.0Walls 17.1427124.5Glazing 7.6188529.9Doors 6.716571.5Ceilings 8.420821.81.8Floors 17.844453.7Infiltration 6.71661Ducts 00Piping 00Humidification 16.74158Ventilation0Adjustments 100.024910Total Cooling Walls Glazing DoorsCeilings OtherInfiltrationDucts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 3.74590.5Walls 37.9474327.3Glazing 3.74577.3Doors 7.39100.8Ceilings 0.2210.0Floors 3.64530.4Infiltration 2.8356Ducts 6.3791Ventilation 34.54320Internal gains 00Blower 0Adjustments 100.012510Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 55 Btuh/ft²-°F Data entries checked. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 4 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Building Analysis 4/20/2020Date:Unit C AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude:Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 19.147525.0Walls 17.1427124.5Glazing 7.6188529.9Doors 6.716571.5Ceilings 8.420821.81.8Floors 17.844453.7Infiltration 6.71661Ducts 00Piping 00Humidification 16.74160Ventilation0Adjustments 100.024912Total Cooling Walls Glazing DoorsCeilings OtherInfiltrationDucts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 3.74590.5Walls 37.9474327.3Glazing 3.74577.3Doors 7.39100.8Ceilings 0.2210.0Floors 3.64530.4Infiltration 2.8356Ducts 6.3792Ventilation 34.54320Internal gains 00Blower 0Adjustments 100.012510Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 55 Btuh/ft²-°F Data entries checked. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 5 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Building Analysis 4/20/2020Date:Unit D AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude:Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 19.247525.0Walls 17.3427124.5Glazing 7.6188529.9Doors 6.716571.5Ceilings 8.420821.81.8Floors 18.044453.7Infiltration 6.01495Ducts 00Piping 00Humidification 16.84158Ventilation0Adjustments 100.024744Total Cooling Walls Glazing DoorsCeilings OtherInfiltrationDucts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 3.74590.5Walls 38.0474327.3Glazing 3.74577.3Doors 7.39100.8Ceilings 0.2210.0Floors 3.64530.4Infiltration 2.6320Ducts 6.3791Ventilation 34.64320Internal gains 00Blower 0Adjustments 100.012473Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 55 Btuh/ft²-°F Data entries checked. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 6 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Building Analysis 4/20/2020Date:Unit E AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude:Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 19.147525.0Walls 17.1427124.5Glazing 7.6188529.9Doors 6.716571.5Ceilings 8.420821.81.8Floors 17.844453.7Infiltration 6.71661Ducts 00Piping 00Humidification 16.74158Ventilation0Adjustments 100.024910Total Cooling Walls Glazing DoorsCeilings OtherInfiltrationDucts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 3.74590.5Walls 37.9474327.3Glazing 3.74577.3Doors 7.39100.8Ceilings 0.2210.0Floors 3.64530.4Infiltration 2.8356Ducts 6.3791Ventilation 34.54320Internal gains 00Blower 0Adjustments 100.012510Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 55 Btuh/ft²-°F Data entries checked. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 7 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Building Analysis 4/20/2020Date:Unit F AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude:Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors CeilingsFloors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 26.177805.0Walls 16.4488424.5Glazing 6.3188529.9Doors 5.616571.5Ceilings 8.324882.12.1Floors 22.868063.7Infiltration 4.81438Ducts 00Piping 00Humidification 9.72893Ventilation0Adjustments 100.029832Total Cooling Walls Glazing Doors CeilingsOtherInfiltrationDucts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 5.57510.5Walls 41.5568528.6Glazing 3.34577.3Doors 6.69100.8Ceilings 0.2210.0Floors 5.16940.4Infiltration 2.3311Ducts 4.0551Ventilation 31.54320Internal gains 00Blower 0Adjustments 100.013699Total Latent Cooling Load = 0 Btuh Overall U-va lue = 0.0 60 Btuh/ft²-°F Data entries checked. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 1 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Component Constructions 4/20/2020Date:Entire House Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude: Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 12F-0sw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 10850.48112474.9921.00.0652256n 6590.4868304.9921.00.0651370e 9320.4896624.9921.00.0651938s 6590.4868304.9921.00.0651370w 33350.48345694.9921.00.0656934all Partitions (none) Windows 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk; foreground = new concrete (0.32); 6.67 ft head ht 339511.3736324.500.320300n 118647.461424.500.32025e 2263130.41826124.500.320744s 118647.461424.500.32025w 2839726.02685124.500.3201094all Doors 11D0: Door, wd sc type 18287.25753829.900.390252n 9147.25376929.900.390126s 27427.251130729.900.390378all Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 54580.8499441.5350.00.0206482 Floors 20P-38t: Flr floor, frm flr, 12" thkns, r-38 cav ins, gar ovr 38.00.0301984 1250.0645652.30 21A-28v: Bg floor, light dry soil, 6.5' depth, vinyl flr fnsh 00.022973 0016421.69 22B-10vpl: Bg floor, light dry soil, on grade depth, r-10 edge ins, vinyl flr fnsh 00709516.110.00.210441 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 2 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Component Constructions 4/20/2020Date:Unit A AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude: Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 12F-0sw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1810.4818754.9921.00.065376n 3320.4834424.9921.00.065691e 1550.4816104.9921.00.065323s 820.488534.9921.00.065171w 7510.4877804.9921.00.0651561all Partitions (none) Windows 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk; foreground = new concrete (0.32); 6.67 ft head ht 56611.3122724.500.32050n 118647.461424.500.32025e 377230.4304324.500.320124s 552327.8488424.500.320199all Doors 11D0: Door, wd sc type 3057.25125629.900.39042n 1527.2562829.900.39021s 4577.25188529.900.39063all Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 9100.8416571.5350.00.0201080 Floors 20P-38t: Flr floor, frm flr, 12" thkns, r-38 cav ins, gar ovr 38.00.030331 210.067612.30 21A-28v: Bg floor, light dry soil, 6.5' depth, vinyl flr fnsh 00.022162 002741.69 22B-10vpl: Bg floor, light dry soil, on grade depth, r-10 edge ins, vinyl flr fnsh 00145416.110.00.21090 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 3 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Component Constructions 4/20/2020Date:Unit B AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude: Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 12F-0sw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1810.4818754.9921.00.065376n 820.488534.9921.00.065171e 1550.4816104.9921.00.065323s 400.484154.9921.00.06583w 4590.4847524.9921.00.065953all Partitions (none) Windows 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk; foreground = new concrete (0.32); 6.67 ft head ht 56611.3122724.500.32050n 377230.4304324.500.320124s 433824.9427124.500.320174all Doors 11D0: Door, wd sc type 3057.25125629.900.39042n 1527.2562829.900.39021s 4577.25188529.900.39063all Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 9100.8416571.5350.00.0201080 Floors 20P-38t: Flr floor, frm flr, 12" thkns, r-38 cav ins, gar ovr 38.00.030331 210.067612.30 21A-28v: Bg floor, light dry soil, 6.5' depth, vinyl flr fnsh 00.022162 002741.69 22B-10vpl: Bg floor, light dry soil, on grade depth, r-10 edge ins, vinyl flr fnsh 00104716.110.00.21065 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 4 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Component Constructions 4/20/2020Date:Unit C AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude: Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 12F-0sw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1810.4818754.9921.00.065376n 400.484154.9921.00.06583e 1550.4816104.9921.00.065323s 820.488534.9921.00.065171w 4590.4847524.9921.00.065953all Partitions (none) Windows 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk; foreground = new concrete (0.32); 6.67 ft head ht 56611.3122724.500.32050n 377230.4304324.500.320124s 433824.9427124.500.320174all Doors 11D0: Door, wd sc type 3057.25125629.900.39042n 1527.2562829.900.39021s 4577.25188529.900.39063all Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 9100.8416571.5350.00.0201080 Floors 20P-38t: Flr floor, frm flr, 12" thkns, r-38 cav ins, gar ovr 38.00.030331 210.067612.30 21A-28v: Bg floor, light dry soil, 6.5' depth, vinyl flr fnsh 00.022162 002741.69 22B-10vpl: Bg floor, light dry soil, on grade depth, r-10 edge ins, vinyl flr fnsh 00104716.110.00.21065 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 5 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Component Constructions 4/20/2020Date:Unit D AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude: Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 12F-0sw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1810.4818754.9921.00.065376n 820.488534.9921.00.065171e 1550.4816104.9921.00.065323s 400.484154.9921.00.06583w 4590.4847524.9921.00.065953all Partitions (none) Windows 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk; foreground = new concrete (0.32); 6.67 ft head ht 56611.3122724.500.32050n 377230.4304324.500.320124s 433824.9427124.500.320174all Doors 11D0: Door, wd sc type 3057.25125629.900.39042n 1527.2562829.900.39021s 4577.25188529.900.39063all Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 9100.8416571.5350.00.0201080 Floors 20P-38t: Flr floor, frm flr, 12" thkns, r-38 cav ins, gar ovr 38.00.030331 210.067612.30 21A-28v: Bg floor, light dry soil, 6.5' depth, vinyl flr fnsh 00.022162 002741.69 22B-10vpl: Bg floor, light dry soil, on grade depth, r-10 edge ins, vinyl flr fnsh 00104716.110.00.21065 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 6 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Component Constructions 4/20/2020Date:Unit E AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude: Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 12F-0sw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1810.4818754.9921.00.065376n 400.484154.9921.00.06583e 1550.4816104.9921.00.065323s 820.488534.9921.00.065171w 4590.4847524.9921.00.065953all Partitions (none) Windows 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk; foreground = new concrete (0.32); 6.67 ft head ht 56611.3122724.500.32050n 377230.4304324.500.320124s 433824.9427124.500.320174all Doors 11D0: Door, wd sc type 3057.25125629.900.39042n 1527.2562829.900.39021s 4577.25188529.900.39063all Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 9100.8416571.5350.00.0201080 Floors 20P-38t: Flr floor, frm flr, 12" thkns, r-38 cav ins, gar ovr 38.00.030331 210.067612.30 21A-28v: Bg floor, light dry soil, 6.5' depth, vinyl flr fnsh 00.022162 002741.69 22B-10vpl: Bg floor, light dry soil, on grade depth, r-10 edge ins, vinyl flr fnsh 00104716.110.00.21065 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 7 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Component Constructions 4/20/2020Date:Unit F AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temp era ture (°F)Idaho Falls Rgnl, ID, US 1577Design TD (°F)ft4744Elevation: 5030Relative humidity (%)°N44Latitude: Outdoor:-29.435.3Moisture difference (gr/lb)CoolingHeating Infiltration:90-7Dry bul b (°F) SimplifiedMethod)H(35-Da ily ra nge (°F) AverageConstruction quality61-We t bu lb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 12F-0sw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 1810.4818754.9921.00.065376n 820.488534.9921.00.065171e 1550.4816104.9921.00.065323s 3320.4834424.9921.00.065691w 7510.4877804.9921.00.0651561all Partitions (none) Windows 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/2" gap, 1/8" thk; foreground = new concrete (0.32); 6.67 ft head ht 56611.3122724.500.32050n 377230.4304324.500.320124s 118647.461424.500.32025w 552327.8488424.500.320199all Doors 11D0: Door, wd sc type 3057.25125629.900.39042n 1527.2562829.900.39021s 4577.25188529.900.39063all Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh 9100.8416571.5350.00.0201080 Floors 20P-38t: Flr floor, frm flr, 12" thkns, r-38 cav ins, gar ovr 38.00.030331 210.067612.30 21A-28v: Bg floor, light dry soil, 6.5' depth, vinyl flr fnsh 00.022162 002741.69 22B-10vpl: Bg floor, light dry soil, on grade depth, r-10 edge ins, vinyl flr fnsh 00145416.110.00.21090 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 1 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Project Summary 4/20/2020Date:Entire House Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor:3846 East 100 North, Rigby, ID 83442 INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Notes: Design Information Idaho Falls Rgnl, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-7 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F77 Design TD °F15Daily range H Relative humidity %50Moisture difference gr/lb-29 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh127365 Structure Btuh70987 Ducts Btuh9484 Ducts Btuh2041Central vent (316 cfm)22422 Btuh Central vent (316 cfm)Btuh4268 Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh159271 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh73122 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh820 Ducts Btuh-91Central vent (316 cfm)Btuh-5306 CoolingHeating1014010140Area (ft²)Equipment latent load Btuh730 9490794907Volume (ft³)Air changes/hour 0.150.28 Equipment Total Load (Sen+Lat)Btuh73852 Equiv. AVF (cfm)237443 Req. total capacity at 0.70 SHR ton8.7 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/aTraden/a Trade n/a Model n/a Cond n/aAHRI ref n/a Coil n/a AHRI ref n/aEfficiencyn/a Efficiency n/a Heating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 2 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Project Summary 4/20/2020Date:Unit A AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor:3846 East 100 North, Rigby, ID 83442 INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Notes: Design Information Idaho Falls Rgnl, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-7 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F77 Design TD °F15Daily range H Relative humidity %50Moisture difference gr/lb-29 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh25500 Structure Btuh12702 Ducts Btuh1568 Ducts Btuh342Central vent (41 cfm)2895 Btuh Central vent (41 cfm)Btuh551 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh29963 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh12861 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh-63 Ducts Btuh-14Central vent (41 cfm)Btuh-685 CoolingHeating Outside air16901690Area (ft²)Equipment latent load Btuh0 1582115821Volume (ft³)Air changes/hour 0.200.36 Equipment Total Load (Sen+Lat)Btuh12861 Equiv. AVF (cfm)5196 Req. total capacity at 1.00 SHR ton1.1 Heating Equipment Summary Cooling Equipment Summary Make Day & Night Make Day & NightTradeDAY & NIGHT Trade 13 SEER N SERIES R410A AC Model N95ESN0401410AA2 Cond N4A324AKN20AHRI ref 4705245 Coil END4X24L14A1++TDR AHRI ref 9386153Efficiency96 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh21620Heating output Btuh33345 Latent cooling Btuh0 Temperature rise °F54 Total cooling Btuh21620Actual air flow cfm665 Actual air flow cfm767 Air flow factor cfm/Btuh0.025 Air flow factor cfm/Btuh0.059Static pressure in H2O0.90 Static pressure in H2O0.90 Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 3 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Project Summary 4/20/2020Date:Unit B AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor:3846 East 100 North, Rigby, ID 83442 INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Notes: Design Information Idaho Falls Rgnl, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-7 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F77 Design TD °F15Daily range H Relative humidity %50Moisture difference gr/lb-29 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh19091 Structure Btuh11362 Ducts Btuh1661 Ducts Btuh356Central vent (59 cfm)4158 Btuh Central vent (59 cfm)Btuh791 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh24910 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh11834 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh236 Ducts Btuh-16Central vent (59 cfm)Btuh-984 CoolingHeating Outside air16901690Area (ft²)Equipment latent load Btuh0 1581615816Volume (ft³)Air changes/hour 0.130.24 Equipment Total Load (Sen+Lat)Btuh11834 Equiv. AVF (cfm)3463 Req. total capacity at 1.00 SHR ton1.0 Heating Equipment Summary Cooling Equipment Summary Make Day & Night Make Day & NightTradeDAY & NIGHT Trade 13 SEER N SERIES R410A AC Model N95ESN0401410AA2 Cond N4A324GKN20AHRI ref 4705245 Coil END4X24L14A1++TDR AHRI ref 9386153Efficiency96 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh21620Heating output Btuh33345 Latent cooling Btuh0 Temperature rise °F54 Total cooling Btuh21620Actual air flow cfm665 Actual air flow cfm767 Air flow factor cfm/Btuh0.032 Air flow factor cfm/Btuh0.065Static pressure in H2O0.90 Static pressure in H2O0.90 Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 4 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Project Summary 4/20/2020Date:Unit C AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor:3846 East 100 North, Rigby, ID 83442 INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Notes: Design Information Idaho Falls Rgnl, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-7 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F77 Design TD °F15Daily range H Relative humidity %50Moisture difference gr/lb-29 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh19091 Structure Btuh11362 Ducts Btuh1661 Ducts Btuh356Central vent (59 cfm)4160 Btuh Central vent (59 cfm)Btuh792 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh24912 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh11834 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh236 Ducts Btuh-16Central vent (59 cfm)Btuh-984 CoolingHeating Outside air16901690Area (ft²)Equipment latent load Btuh0 1582115821Volume (ft³)Air changes/hour 0.130.24 Equipment Total Load (Sen+Lat)Btuh11834 Equiv. AVF (cfm)3463 Req. total capacity at 1.00 SHR ton1.0 Heating Equipment Summary Cooling Equipment Summary Make Day & Night Make Day & NightTradeDAY & NIGHT Trade 13 SEER N SERIES R410A AC Model N95ESN0401410AA2 Cond N4A324GKN20AHRI ref 4705245 Coil END4X24L14A1++TDR AHRI ref 9386153Efficiency96 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh21620Heating output Btuh33345 Latent cooling Btuh0 Temperature rise °F54 Total cooling Btuh21620Actual air flow cfm665 Actual air flow cfm767 Air flow factor cfm/Btuh0.032 Air flow factor cfm/Btuh0.065Static pressure in H2O0.90 Static pressure in H2O0.90 Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 5 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Project Summary 4/20/2020Date:Unit D AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor:3846 East 100 North, Rigby, ID 83442 INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Notes: Design Information Idaho Falls Rgnl, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-7 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F77 Design TD °F15Daily range H Relative humidity %50Moisture difference gr/lb-29 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh19091 Structure Btuh11362 Ducts Btuh1495 Ducts Btuh320Central vent (59 cfm)4158 Btuh Central vent (59 cfm)Btuh791 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh24744 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh11800 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh236 Ducts Btuh-15Central vent (59 cfm)Btuh-984 CoolingHeating Outside air16901690Area (ft²)Equipment latent load Btuh0 1581615816Volume (ft³)Air changes/hour 0.130.24 Equipment Total Load (Sen+Lat)Btuh11800 Equiv. AVF (cfm)3463 Req. total capacity at 1.00 SHR ton1.0 Heating Equipment Summary Cooling Equipment Summary Make Day & Night Make Day & NightTradeDAY & NIGHT Trade 13 SEER N SERIES R410A AC Model N95ESN0401410AA2 Cond N4A324GKN20AHRI ref 4705245 Coil END4X24L14A1++TDR AHRI ref 9386153Efficiency96 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh21620Heating output Btuh33345 Latent cooling Btuh0 Temperature rise °F54 Total cooling Btuh21620Actual air flow cfm665 Actual air flow cfm665 Air flow factor cfm/Btuh0.032 Air flow factor cfm/Btuh0.057Static pressure in H2O0.90 Static pressure in H2O0.90 Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 6 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Project Summary 4/20/2020Date:Unit E AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor:3846 East 100 North, Rigby, ID 83442 INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Notes: Design Information Idaho Falls Rgnl, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-7 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F77 Design TD °F15Daily range H Relative humidity %50Moisture difference gr/lb-29 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh19091 Structure Btuh11362 Ducts Btuh1661 Ducts Btuh356Central vent (59 cfm)4158 Btuh Central vent (59 cfm)Btuh791 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh24910 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh11834 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh236 Ducts Btuh-16Central vent (59 cfm)Btuh-984 CoolingHeating Outside air16901690Area (ft²)Equipment latent load Btuh0 1581615816Volume (ft³)Air changes/hour 0.130.24 Equipment Total Load (Sen+Lat)Btuh11834 Equiv. AVF (cfm)3463 Req. total capacity at 1.00 SHR ton1.0 Heating Equipment Summary Cooling Equipment Summary Make Day & Night Make Day & NightTradeDAY & NIGHT Trade 13 SEER N SERIES R410A AC Model N95ESN0401410AA2 Cond N4A324GKN20AHRI ref 4705245 Coil END4X24L14A1++TDR AHRI ref 9386153Efficiency96 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh21620Heating output Btuh33345 Latent cooling Btuh0 Temperature rise °F54 Total cooling Btuh21620Actual air flow cfm665 Actual air flow cfm767 Air flow factor cfm/Btuh0.032 Air flow factor cfm/Btuh0.065Static pressure in H2O0.90 Static pressure in H2O0.90 Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 7 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Project Summary 4/20/2020Date:Unit F AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor:3846 East 100 North, Rigby, ID 83442 INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Notes: Design Information Idaho Falls Rgnl, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-7 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F77 Design TD °F15Daily range H Relative humidity %50Moisture difference gr/lb-29 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh25500 Structure Btuh12837 Ducts Btuh1438 Ducts Btuh311Central vent (41 cfm)2893 Btuh Central vent (41 cfm)Btuh551 Outside air Outside airHumidificationBtuh0Blower Btuh0 Piping Btuh0Equipment load Btuh29832 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh12959 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh-63 Ducts Btuh-14Central vent (41 cfm)Btuh-685 CoolingHeating Outside air16901690Area (ft²)Equipment latent load Btuh0 1581615816Volume (ft³)Air changes/hour 0.200.36 Equipment Total Load (Sen+Lat)Btuh12959 Equiv. AVF (cfm)5196 Req. total capacity at 1.00 SHR ton1.1 Heating Equipment Summary Cooling Equipment Summary Make Day & Night Make Day & NightTradeDAY & NIGHT Trade 13 SEER N SERIES R410A AC Model N95ESN0401410AA2 Cond N4A324GKN20AHRI ref 4705245 Coil END4X24L14A1++TDR AHRI ref 9386153Efficiency96 AFUE Efficiency 10.5 EER, 13 SEER Heating input Btuh40000 Sensible cooling Btuh21620Heating output Btuh33345 Latent cooling Btuh0 Temperature rise °F54 Total cooling Btuh21620Actual air flow cfm665 Actual air flow cfm665 Air flow factor cfm/Btuh0.025 Air flow factor cfm/Btuh0.051Static pressure in H2O0.90 Static pressure in H2O0.90 Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 1...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Entire House Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Entire House Unit B AH 2 Exposed wall 904.0 ft 127.3 ft 3 Room height 9.4 ft 9.4 ft 4 Room dimensions 5 Room area 10140.3 f t²1689.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 2808 2256 11247 1085 468 376 1875 181 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 300 0 7363 3395 50 0 1227 566 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 252 252 7538 1828 42 42 1256 305 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 1395 1370 6830 659 171 171 853 82 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 24.5424.54 47.4247.42 25 0 614 1186 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 2808 1938 9662 932 468 323 1610 155 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 744 0 18261 22631 124 0 3043 3772 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 126 126 3769 914 21 21 628 152 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 1395 1370 6830 659 83 83 415 40 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 24.5424.54 47.4247.42 25 0 614 1186 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 6482 6482 9944 5458 1080 1080 1657 910 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 1984 1984 4565 125 331 331 761 21 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 973 973 1642 0 162 162 274 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 4121 441 7095 0 687 65 1047 0 6 c) AED excursion 1809 405 Envelope loss/gain 95974 41866 14646 6589 12 a)Infiltration 31391 3201 4445 453 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 24 5520 4 920 Appliances/other 20400 3400 Subtotal (lines 6 to 13)127365 70987 19091 11362 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 127365 70987 19091 11362 15 Duct loads 7%3%9484 2041 9%3%1661 356 Total room load 136849 73028 20752 11718 Air required (cfm)Air required (cfm)3990 4398 665 767 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 2...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Entire House Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Unit A AH Unit C AH 2 Exposed wall 197.5 ft 127.3 ft 3 Room height 9.4 ft 9.4 ft 4 Room dimensions 5 Room area 1690.4 f t²1690.4 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 468 376 1875 181 468 376 1875 181 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 50 0 1227 566 50 0 1227 566 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 42 42 1256 305 42 42 1256 305 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 716 691 3442 332 83 83 415 40 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 24.5424.54 47.4247.42 25 0 614 1186 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 468 323 1610 155 468 323 1610 155 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 124 0 3043 3772 124 0 3043 3772 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 21 21 628 152 21 21 628 152 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 171 171 853 82 171 171 853 82 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 24.5424.54 47.4247.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 1080 1080 1657 910 1080 1080 1657 910 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 331 331 761 21 331 331 761 21 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 162 162 274 0 162 162 274 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 687 90 1454 0 687 65 1047 0 6 c) AED excursion 27 405 Envelope loss/gain 18694 7688 14646 6589 12 a)Infiltration 6806 694 4445 453 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 4 920 4 920 Appliances/other 3400 3400 Subtotal (lines 6 to 13)25500 12702 19091 11362 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 25500 12702 19091 11362 15 Duct loads 6%3%1568 342 9%3%1661 356 Total room load 27068 13044 20752 11718 Air required (cfm)Air required (cfm)665 767 665 767 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 3...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Entire House Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Unit D AH Unit E AH 2 Exposed wall 127.3 ft 127.3 ft 3 Room height 9.4 ft 9.4 ft 4 Room dimensions 5 Room area 1689.9 f t²1689.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 468 376 1875 181 468 376 1875 181 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 50 0 1227 566 50 0 1227 566 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 42 42 1256 305 42 42 1256 305 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 171 171 853 82 83 83 415 40 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 24.5424.54 47.4247.42 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 468 323 1610 155 468 323 1610 155 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 124 0 3043 3772 124 0 3043 3772 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 21 21 628 152 21 21 628 152 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 83 83 415 40 171 171 853 82 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 24.5424.54 47.4247.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 1080 1080 1657 910 1080 1080 1657 910 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 331 331 761 21 331 331 761 21 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 162 162 274 0 162 162 274 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 687 65 1047 0 687 65 1047 0 6 c) AED excursion 405 405 Envelope loss/gain 14646 6589 14646 6589 12 a)Infiltration 4445 453 4445 453 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 4 920 4 920 Appliances/other 3400 3400 Subtotal (lines 6 to 13)19091 11362 19091 11362 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 19091 11362 19091 11362 15 Duct loads 8%3%1495 320 9%3%1661 356 Total room load 20586 11682 20752 11718 Air required (cfm)Air required (cfm)665 665 665 767 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 4...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Entire House Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Unit F AH 2 Exposed wall 197.5 ft 3 Room height 9.4 ft 4 Room dimensions 5 Room area 1689.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area Load number (Bt uh/f t²-°F)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12F-0sw 0.065 n 4.99 0.48 468 376 1875 181 .G 2 glazing, clr low-e 0.320 n 24.54 11.32 50 0 1227 566 .D 11D0 0.390 n 29.91 7.25 42 42 1256 305 .W 12F-0sw 0.065 e 4.99 0.48 171 171 853 82 1 1 G 2 glazing, clr low-e 0.320 e 24.54 47.42 0 0 0 0 W 12F-0sw 0.065 s 4.99 0.48 468 323 1610 155 G 2 glazing, clr low-e 0.320 s 24.54 30.42 124 0 3043 3772 D 11D0 0.390 s 29.91 7.25 21 21 628 152 W 12F-0sw 0.065 w 4.99 0.48 716 691 3442 332 G 2 glazing, clr low-e 0.320 w 24.54 47.42 25 0 614 1186 C 16B-50ad 0.020 -1.53 0.84 1080 1080 1657 910 F 20P-38t 0.030 -2.30 0.06 331 331 761 21 F 21A-28v 0.022 -1.69 0.00 162 162 274 0 F 22B-10vpl 0.210 -16.11 0.00 687 90 1454 0 6 c) AED excursion 162 Envelope loss/gain 18694 7823 12 a)Infiltration 6806 694 b)Room ventilation 0 0 13 Internal gains:Occupants @ 230 4 920 Appliances/other 3400 Subtotal (lines 6 to 13)25500 12837 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 25500 12837 15 Duct loads 6%2%1438 311 Total room load 26938 13148 Air required (cfm)665 665 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 5...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit A AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Unit A AH Mech 2 Exposed wall 197.5 ft 6.3 ft 3 Room height 9.4 ft 9.0 heat/coolft 4 Room dimensions ft6.3x6.3 5 Room area 1690.4 f t²39.1 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 468 376 1875 181 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 50 0 1227 566 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 42 42 1256 305 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 716 691 3442 332 56 56 280 27 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 24.5424.54 47.4247.42 25 0 614 1186 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 468 323 1610 155 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 124 0 3043 3772 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 21 21 628 152 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 171 171 853 82 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 1080 1080 1657 910 39 39 60 33 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 331 331 761 21 39 39 90 2 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 162 162 274 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 687 90 1454 0 0 0 0 0 6 c) AED excursion 27 -1 Envelope loss/gain 18694 7688 430 62 12 a)Infiltration 6806 694 210 21 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 4 920 0 0 Appliances/other 3400 0 Subtotal (lines 6 to 13)25500 12702 640 83 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 -640 -83 14 Subtotal 25500 12702 0 0 15 Duct loads 6%3%1568 342 25%21%0 0 Total room load 27068 13044 0 0 Air required (cfm)Air required (cfm)665 767 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 6...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit A AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Pantry A Powder A 2 Exposed wall 10.5 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft5.8x4.8 ft6.0x5.1 5 Room area 27.3 f t²30.5 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 43 43 213 21 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 52 52 258 25 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 24.5424.54 47.4247.42 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 0 0 0 0 0 0 0 0 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 27 11 169 0 30 0 0 0 6 c) AED excursion -1 0 Envelope loss/gain 640 45 0 0 12 a)Infiltration 353 36 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)993 81 0 0 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -993 -81 0 0 14 Subtotal 0 0 0 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 0 0 Air required (cfm)Air required (cfm)0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 7...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit A AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Kit/din/Family A Bedroom 2 A 2 Exposed wall 79.8 ft 25.8 ft 3 Room height 10.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft629.4x1.0 ft13.5x10.5 5 Room area 629.4 f t²141.8 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 236 184 919 89 95 75 371 36 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 10 0 245 113 20 0 491 226 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 42 42 1256 305 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 259 234 1165 112 122 122 606 58 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 24.5424.54 47.4247.42 25 0 614 1186 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 234 135 673 65 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 78 0 1914 2373 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 21 21 628 152 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 34 34 168 16 16 16 79 8 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 77 77 119 65 142 142 217 119 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 142 142 326 9 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 629 80 1285 0 0 0 0 0 6 c) AED excursion -79 -8 Envelope loss/gain 8986 4396 2090 448 12 a)Infiltration 2848 290 865 88 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 1 230 Appliances/other 2900 0 Subtotal (lines 6 to 13)11835 7587 2956 767 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 993 81 378 56 14 Subtotal 12828 7667 3333 823 15 Duct loads -0%0%0 0 25%21%826 172 Total room load 12828 7667 4160 995 Air required (cfm)Air required (cfm)315 451 102 59 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 8...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit A AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Bedroom 3 A 3A WIC 2 Exposed wall 22.3 ft 0.8 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft11.8x10.5 ft5.5x5.3 5 Room area 123.4 f t²28.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 95 75 371 36 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 20 0 491 226 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 24.5424.54 47.4247.42 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 106 106 527 51 7 7 34 3 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 123 123 189 104 29 29 44 24 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 123 123 284 8 27 27 61 2 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -8 0 Envelope loss/gain 1863 417 139 29 12 a)Infiltration 748 76 25 3 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2610 723 164 31 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 71 18 146 38 14 Subtotal 2682 742 310 69 15 Duct loads 25%21%665 155 25%21%77 14 Total room load 3346 897 387 84 Air required (cfm)Air required (cfm)82 53 10 5 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 9...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit A AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Bath A Master A 2 Exposed wall 9.8 ft 32.8 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft9.8x6.3 ft15.5x16.3 5 Room area 60.9 f t²251.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 88 88 437 42 140 140 695 67 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 24.5424.54 47.4247.42 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 146 116 580 56 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 30 0 736 913 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 9 9 45 4 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 61 61 93 51 252 252 386 212 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -1 84 Envelope loss/gain 531 92 2443 1336 12 a)Infiltration 328 33 1101 112 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)859 126 3543 1908 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 452 76 99 393 14 Subtotal 1311 201 3642 2301 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1311 201 3642 2301 Air required (cfm)Air required (cfm)32 12 89 135 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 10...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit A AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name M Bath A M WIC A 2 Exposed wall 9.8 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft11.0x9.8 ft50.3x1.0 5 Room area 107.3 f t²50.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 24.5424.54 47.4247.42 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 88 72 358 35 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 16 0 393 487 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 107 107 165 90 50 50 77 42 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 48 0 Envelope loss/gain 915 660 77 42 12 a)Infiltration 328 33 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1243 693 77 42 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 74 163 14 Subtotal 1243 693 151 205 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1243 693 151 205 Air required (cfm)Air required (cfm)31 41 4 12 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 11...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit A AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Laundry A Stairs/Hall A 2 Exposed wall 0 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft6.0x6.3 ft162.2x1.0 5 Room area 37.5 f t²162.2 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 24.5424.54 47.4247.42 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 38 38 58 32 162 162 249 137 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 162 162 274 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -6 -1 Envelope loss/gain 58 26 522 135 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)58 526 522 135 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -58 -526 -522 -135 14 Subtotal 0 0 0 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 0 0 Air required (cfm)Air required (cfm)0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 12...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit B AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Unit B AH Pantry B 2 Exposed wall 127.3 ft 4.8 ft 3 Room height 9.4 ft 9.0 heat/coolft 4 Room dimensions ft5.8x4.8 5 Room area 1689.9 f t²27.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 468 376 1875 181 43 43 213 21 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 50 0 1227 566 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 42 42 1256 305 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 171 171 853 82 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 468 323 1610 155 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 124 0 3043 3772 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 21 21 628 152 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 83 83 415 40 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 1080 1080 1657 910 0 0 0 0 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 331 331 761 21 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 162 162 274 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 687 65 1047 0 27 5 77 0 6 c) AED excursion 405 0 Envelope loss/gain 14646 6589 290 20 12 a)Infiltration 4445 453 160 16 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 4 920 0 0 Appliances/other 3400 0 Subtotal (lines 6 to 13)19091 11362 449 37 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 -449 -37 14 Subtotal 19091 11362 0 0 15 Duct loads 9%3%1661 356 -0%0%0 0 Total room load 20752 11718 0 0 Air required (cfm)Air required (cfm)665 767 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 13...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit B AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Powder B Kit/Din/Family B 2 Exposed wall 0 ft 60.3 ft 3 Room height 9.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft6.0x5.0 ft629.4x1.0 5 Room area 30.0 f t²629.4 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 236 184 919 89 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 10 0 245 113 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 42 42 1256 305 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 34 34 168 16 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 234 135 673 65 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 78 0 1914 2373 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 21 21 628 152 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 83 83 415 40 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 0 0 0 0 77 77 119 65 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 30 0 0 0 629 60 970 0 6 c) AED excursion 0 254 Envelope loss/gain 0 0 7308 3472 12 a)Infiltration 0 0 2193 224 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 2900 Subtotal (lines 6 to 13)0 0 9501 6595 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 449 37 14 Subtotal 0 0 9951 6632 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 9951 6632 Air required (cfm)Air required (cfm)0 0 319 434 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 14...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit B AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Bedroom 2B Bedroom 3 B 2 Exposed wall 12.3 ft 22.3 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft13.5x10.5 ft11.8x10.5 5 Room area 141.8 f t²123.4 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 95 75 371 36 95 75 371 36 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 20 0 491 226 20 0 491 226 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 16 16 79 8 106 106 527 51 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 142 142 217 119 123 123 189 104 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 142 142 326 9 123 123 284 8 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -1 -1 Envelope loss/gain 1484 397 1863 423 12 a)Infiltration 412 42 748 76 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)1896 669 2610 730 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 133 33 71 19 14 Subtotal 2029 702 2682 748 15 Duct loads 33%23%671 164 33%23%887 175 Total room load 2700 866 3569 924 Air required (cfm)Air required (cfm)87 57 114 60 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 15...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit B AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Bath B Master B 2 Exposed wall 0 ft 17.3 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft9.8x6.3 ft15.5x16.3 5 Room area 60.9 f t²251.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 9 9 45 4 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 146 116 580 56 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 30 0 736 913 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 61 61 93 51 252 252 386 212 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 101 Envelope loss/gain 93 51 1747 1286 12 a)Infiltration 0 0 580 59 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)93 51 2327 1805 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 207 52 99 396 14 Subtotal 301 103 2426 2201 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 301 103 2426 2201 Air required (cfm)Air required (cfm)10 7 78 144 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 16...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit B AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name M Bath B M WIC B 2 Exposed wall 9.8 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft11.0x9.8 ft50.3x1.0 5 Room area 107.3 f t²50.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 88 72 358 35 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 16 0 393 487 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 107 107 165 90 50 50 77 42 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 54 0 Envelope loss/gain 915 666 77 42 12 a)Infiltration 328 33 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1243 699 77 42 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 74 164 14 Subtotal 1243 699 151 207 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1243 699 151 207 Air required (cfm)Air required (cfm)40 46 5 14 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 17...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit B AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Laundry B Stairs/Hall B 2 Exposed wall 0 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft6.0x6.3 ft162.2x1.0 5 Room area 37.5 f t²162.2 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 38 38 58 32 162 162 249 137 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 162 162 274 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -1 0 Envelope loss/gain 58 31 522 136 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)58 531 522 136 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -58 -531 -522 -136 14 Subtotal 0 0 0 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 0 0 Air required (cfm)Air required (cfm)0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 18...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit B AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name 3 B WIC Mech B 2 Exposed wall 0.8 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft5.5x5.3 ft6.3x6.3 5 Room area 28.9 f t²39.1 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 7 7 34 3 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 29 29 44 24 39 39 60 33 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 27 27 61 2 39 39 90 2 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 139 29 150 35 12 a)Infiltration 25 3 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)164 32 150 35 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 146 38 -150 -35 14 Subtotal 310 70 0 0 15 Duct loads 33%23%103 16 33%23%0 0 Total room load 413 86 0 0 Air required (cfm)Air required (cfm)13 6 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 19...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit C AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Unit C AH Mech C 2 Exposed wall 127.3 ft 0 ft 3 Room height 9.4 ft 9.0 heat/coolft 4 Room dimensions ft6.3x6.3 5 Room area 1690.4 f t²39.1 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 468 376 1875 181 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 50 0 1227 566 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 42 42 1256 305 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 83 83 415 40 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 468 323 1610 155 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 124 0 3043 3772 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 21 21 628 152 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 171 171 853 82 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 1080 1080 1657 910 39 39 60 33 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 331 331 761 21 39 39 90 2 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 162 162 274 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 687 65 1047 0 0 0 0 0 6 c) AED excursion 405 0 Envelope loss/gain 14646 6589 150 35 12 a)Infiltration 4445 453 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 4 920 0 0 Appliances/other 3400 0 Subtotal (lines 6 to 13)19091 11362 150 35 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 -150 -35 14 Subtotal 19091 11362 0 0 15 Duct loads 9%3%1661 356 33%23%0 0 Total room load 20752 11718 0 0 Air required (cfm)Air required (cfm)665 767 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 20...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit C AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Bedroom 2 C Pantry C 2 Exposed wall 12.3 ft 4.8 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft13.5x10.5 ft5.8x4.8 5 Room area 141.8 f t²27.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 95 75 371 36 43 43 213 21 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 20 0 491 226 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 16 16 79 8 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 142 142 217 119 0 0 0 0 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 142 142 326 9 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 27 5 77 0 6 c) AED excursion -1 0 Envelope loss/gain 1484 397 290 20 12 a)Infiltration 412 42 160 16 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1896 669 449 37 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 133 33 -449 -37 14 Subtotal 2029 702 0 0 15 Duct loads 33%23%671 164 -0%0%0 0 Total room load 2700 866 0 0 Air required (cfm)Air required (cfm)87 57 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 21...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit C AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name 3 C WIC Powder C 2 Exposed wall 0.8 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft5.5x5.3 ft6.0x5.1 5 Room area 28.9 f t²30.5 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 7 7 34 3 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 29 29 44 24 0 0 0 0 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 27 27 61 2 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 30 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 139 29 0 0 12 a)Infiltration 25 3 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)164 32 0 0 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 146 38 0 0 14 Subtotal 310 70 0 0 15 Duct loads 33%23%103 16 -0%0%0 0 Total room load 413 86 0 0 Air required (cfm)Air required (cfm)13 6 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 22...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit C AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Kit/Din/Family C Bedroom 3 C 2 Exposed wall 60.3 ft 22.3 ft 3 Room height 10.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft629.4x1.0 ft11.8x10.5 5 Room area 629.4 f t²123.4 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 236 184 919 89 95 75 371 36 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 10 0 245 113 20 0 491 226 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 42 42 1256 305 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 83 83 415 40 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 234 135 673 65 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 78 0 1914 2373 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 21 21 628 152 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 34 34 168 16 106 106 527 51 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 77 77 119 65 123 123 189 104 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 123 123 284 8 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 629 60 970 0 0 0 0 0 6 c) AED excursion 254 -1 Envelope loss/gain 7308 3472 1863 423 12 a)Infiltration 2193 224 748 76 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 1 230 Appliances/other 2900 0 Subtotal (lines 6 to 13)9501 6595 2610 730 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 449 37 71 19 14 Subtotal 9951 6632 2682 748 15 Duct loads -0%0%0 0 33%23%887 175 Total room load 9951 6632 3569 924 Air required (cfm)Air required (cfm)319 434 114 60 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 23...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit C AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Bath C Master C 2 Exposed wall 0 ft 17.3 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft9.8x6.3 ft15.5x16.3 5 Room area 60.9 f t²251.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 146 116 580 56 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 30 0 736 913 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 9 9 45 4 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 61 61 93 51 252 252 386 212 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 101 Envelope loss/gain 93 51 1747 1286 12 a)Infiltration 0 0 580 59 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)93 51 2327 1805 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 207 52 99 396 14 Subtotal 301 103 2426 2201 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 301 103 2426 2201 Air required (cfm)Air required (cfm)10 7 78 144 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 24...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit C AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name M Bath C M WIC C 2 Exposed wall 9.8 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft11.0x9.8 ft50.3x1.0 5 Room area 107.3 f t²50.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 88 72 358 35 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 16 0 393 487 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 107 107 165 90 50 50 77 42 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 54 0 Envelope loss/gain 915 666 77 42 12 a)Infiltration 328 33 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1243 699 77 42 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 74 164 14 Subtotal 1243 699 151 207 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1243 699 151 207 Air required (cfm)Air required (cfm)40 46 5 14 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 25...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit C AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Laundry C Stairs/Hall C 2 Exposed wall 0 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft6.0x6.3 ft162.2x1.0 5 Room area 37.5 f t²162.2 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 38 38 58 32 162 162 249 137 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 162 162 274 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -1 0 Envelope loss/gain 58 31 522 136 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)58 531 522 136 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -58 -531 -522 -136 14 Subtotal 0 0 0 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 0 0 Air required (cfm)Air required (cfm)0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 26...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit D AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Unit D AH Mech D 2 Exposed wall 127.3 ft 0 ft 3 Room height 9.4 ft 9.0 heat/coolft 4 Room dimensions ft6.3x6.3 5 Room area 1689.9 f t²39.1 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 468 376 1875 181 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 50 0 1227 566 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 42 42 1256 305 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 171 171 853 82 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 468 323 1610 155 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 124 0 3043 3772 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 21 21 628 152 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 83 83 415 40 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 1080 1080 1657 910 39 39 60 33 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 331 331 761 21 39 39 90 2 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 162 162 274 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 687 65 1047 0 0 0 0 0 6 c) AED excursion 405 0 Envelope loss/gain 14646 6589 150 35 12 a)Infiltration 4445 453 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 4 920 0 0 Appliances/other 3400 0 Subtotal (lines 6 to 13)19091 11362 150 35 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 -150 -35 14 Subtotal 19091 11362 0 0 15 Duct loads 8%3%1495 320 30%21%0 0 Total room load 20586 11682 0 0 Air required (cfm)Air required (cfm)665 665 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 27...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit D AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Bedroom 2 D Bedroom 3 D 2 Exposed wall 12.3 ft 22.3 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft13.5x10.5 ft11.8x10.5 5 Room area 141.8 f t²123.4 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 95 75 371 36 95 75 371 36 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 20 0 491 226 20 0 491 226 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 16 16 79 8 106 106 527 51 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 142 142 217 119 123 123 189 104 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 142 142 326 9 123 123 284 8 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -1 -1 Envelope loss/gain 1484 397 1863 423 12 a)Infiltration 412 42 748 76 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)1896 669 2610 730 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 115 28 50 13 14 Subtotal 2011 697 2660 743 15 Duct loads 30%21%609 149 30%21%806 159 Total room load 2620 846 3466 901 Air required (cfm)Air required (cfm)85 48 112 51 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 28...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit D AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Pantry D Powder D 2 Exposed wall 4.8 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft5.8x4.8 ft6.0x5.0 5 Room area 27.3 f t²30.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 43 43 213 21 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 0 0 0 0 0 0 0 0 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 27 5 77 0 30 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 290 20 0 0 12 a)Infiltration 160 16 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)449 37 0 0 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -449 -37 0 0 14 Subtotal 0 0 0 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 0 0 Air required (cfm)Air required (cfm)0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 29...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit D AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Kit/Din/Family D Bath D 2 Exposed wall 60.3 ft 0 ft 3 Room height 10.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft629.4x1.0 ft9.8x6.3 5 Room area 629.4 f t²60.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 236 184 919 89 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 10 0 245 113 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 42 42 1256 305 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 34 34 168 16 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 234 135 673 65 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 78 0 1914 2373 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 21 21 628 152 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 83 83 415 40 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 77 77 119 65 61 61 93 51 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 629 60 970 0 0 0 0 0 6 c) AED excursion 254 0 Envelope loss/gain 7308 3472 93 51 12 a)Infiltration 2193 224 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 2900 0 Subtotal (lines 6 to 13)9501 6595 93 51 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 449 37 168 42 14 Subtotal 9951 6632 261 93 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 9951 6632 261 93 Air required (cfm)Air required (cfm)321 378 8 5 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 30...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit D AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Master D M Bath D 2 Exposed wall 17.3 ft 9.8 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft15.5x16.3 ft11.0x9.8 5 Room area 251.9 f t²107.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 9 9 45 4 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 146 116 580 56 88 72 358 35 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 30 0 736 913 16 0 393 487 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 252 252 386 212 107 107 165 90 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 101 54 Envelope loss/gain 1747 1286 915 666 12 a)Infiltration 580 59 328 33 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2327 1805 1243 699 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 40 11 0 0 14 Subtotal 2367 1815 1243 699 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2367 1815 1243 699 Air required (cfm)Air required (cfm)76 103 40 40 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 31...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit D AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name M WIC D Laundry D 2 Exposed wall 0 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft50.3x1.0 ft6.0x6.3 5 Room area 50.3 f t²37.5 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 50 50 77 42 38 38 58 32 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 -1 Envelope loss/gain 77 42 58 31 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13)77 42 58 531 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 40 11 157 41 14 Subtotal 118 53 214 572 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 118 53 214 572 Air required (cfm)Air required (cfm)4 3 7 33 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 32...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit D AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Stairs/Hall D 3 D WIC 2 Exposed wall 0 ft 0.8 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft162.2x1.0 ft5.5x5.3 5 Room area 162.2 f t²28.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 7 7 34 3 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 162 162 249 137 29 29 44 24 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 27 27 61 2 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 162 162 274 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 522 136 139 29 12 a)Infiltration 0 0 25 3 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)522 136 164 32 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -522 -136 102 27 14 Subtotal 0 0 266 58 15 Duct loads -0%0%0 0 30%21%81 12 Total room load 0 0 347 71 Air required (cfm)Air required (cfm)0 0 11 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 33...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit E AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Unit E AH Mech E 2 Exposed wall 127.3 ft 0 ft 3 Room height 9.4 ft 9.0 heat/coolft 4 Room dimensions ft6.3x6.3 5 Room area 1689.9 f t²39.1 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 468 376 1875 181 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 50 0 1227 566 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 42 42 1256 305 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 83 83 415 40 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 468 323 1610 155 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 124 0 3043 3772 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 21 21 628 152 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 171 171 853 82 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 1080 1080 1657 910 39 39 60 33 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 331 331 761 21 39 39 90 2 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 162 162 274 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 687 65 1047 0 0 0 0 0 6 c) AED excursion 405 0 Envelope loss/gain 14646 6589 150 35 12 a)Infiltration 4445 453 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 4 920 0 0 Appliances/other 3400 0 Subtotal (lines 6 to 13)19091 11362 150 35 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 -150 -35 14 Subtotal 19091 11362 0 0 15 Duct loads 9%3%1661 356 33%23%0 0 Total room load 20752 11718 0 0 Air required (cfm)Air required (cfm)665 767 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 34...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit E AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Laundry E Master E 2 Exposed wall 0 ft 17.3 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft6.0x6.3 ft15.5x16.3 5 Room area 37.5 f t²251.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 146 116 580 56 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 30 0 736 913 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 9 9 45 4 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 38 38 58 32 252 252 386 212 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -1 101 Envelope loss/gain 58 31 1747 1286 12 a)Infiltration 0 0 580 59 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 2 460 Appliances/other 500 0 Subtotal (lines 6 to 13)58 531 2327 1805 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -58 -531 99 396 14 Subtotal 0 0 2426 2201 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 2426 2201 Air required (cfm)Air required (cfm)0 0 78 144 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 35...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit E AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name M Bath E M WIC E 2 Exposed wall 9.8 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft11.0x9.8 ft50.3x1.0 5 Room area 107.3 f t²50.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 88 72 358 35 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 16 0 393 487 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 107 107 165 90 50 50 77 42 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 54 0 Envelope loss/gain 915 666 77 42 12 a)Infiltration 328 33 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1243 699 77 42 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 74 164 14 Subtotal 1243 699 151 207 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1243 699 151 207 Air required (cfm)Air required (cfm)40 46 5 14 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 36...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit E AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Kit/Din/Family E Pantry E 2 Exposed wall 60.3 ft 4.8 ft 3 Room height 10.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft629.4x1.0 ft5.8x4.8 5 Room area 629.4 f t²27.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 236 184 919 89 43 43 213 21 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 10 0 245 113 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 42 42 1256 305 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 83 83 415 40 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 234 135 673 65 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 78 0 1914 2373 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 21 21 628 152 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 34 34 168 16 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 77 77 119 65 0 0 0 0 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 629 60 970 0 27 5 77 0 6 c) AED excursion 254 0 Envelope loss/gain 7308 3472 290 20 12 a)Infiltration 2193 224 160 16 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 2900 0 Subtotal (lines 6 to 13)9501 6595 449 37 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 449 37 -449 -37 14 Subtotal 9951 6632 0 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 9951 6632 0 0 Air required (cfm)Air required (cfm)319 434 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 37...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit E AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Powder E Bedroom 2 E 2 Exposed wall 0 ft 12.3 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft6.0x5.0 ft13.5x10.5 5 Room area 30.0 f t²141.8 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 95 75 371 36 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 20 0 491 226 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 16 16 79 8 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 0 0 0 0 142 142 217 119 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 142 142 326 9 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 30 0 0 0 0 0 0 0 6 c) AED excursion 0 -1 Envelope loss/gain 0 0 1484 397 12 a)Infiltration 0 0 412 42 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)0 0 1896 669 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 133 33 14 Subtotal 0 0 2029 702 15 Duct loads -0%0%0 0 33%23%671 164 Total room load 0 0 2700 866 Air required (cfm)Air required (cfm)0 0 87 57 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 38...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit E AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Bedroom 3 E Bath E 2 Exposed wall 22.3 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft11.8x10.5 ft9.8x6.3 5 Room area 123.4 f t²60.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 95 75 371 36 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 20 0 491 226 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 106 106 527 51 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 123 123 189 104 61 61 93 51 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 123 123 284 8 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -1 0 Envelope loss/gain 1863 423 93 51 12 a)Infiltration 748 76 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2610 730 93 51 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 71 19 207 52 14 Subtotal 2682 748 301 103 15 Duct loads 33%23%887 175 -0%0%0 0 Total room load 3569 924 301 103 Air required (cfm)Air required (cfm)114 60 10 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 39...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit E AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name 3 E WIC Stairs/Hall E 2 Exposed wall 0.8 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft5.5x5.3 ft162.2x1.0 5 Room area 28.9 f t²162.2 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 7 7 34 3 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 29 29 44 24 162 162 249 137 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 27 27 61 2 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 162 162 274 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 139 29 522 136 12 a)Infiltration 25 3 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)164 32 522 136 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 146 38 -522 -136 14 Subtotal 310 70 0 0 15 Duct loads 33%23%103 16 -0%0%0 0 Total room load 413 86 0 0 Air required (cfm)Air required (cfm)13 6 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 40...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit F AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Unit F AH Mech F 2 Exposed wall 197.5 ft 6.3 ft 3 Room height 9.4 ft 9.0 heat/coolft 4 Room dimensions ft6.3x6.3 5 Room area 1689.9 f t²39.1 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 468 376 1875 181 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 50 0 1227 566 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 42 42 1256 305 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 171 171 853 82 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 468 323 1610 155 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 124 0 3043 3772 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 21 21 628 152 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 716 691 3442 332 56 56 280 27 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 24.5424.54 47.4247.42 25 0 614 1186 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 1080 1080 1657 910 39 39 60 33 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 331 331 761 21 39 39 90 2 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 162 162 274 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 687 90 1454 0 0 0 0 0 6 c) AED excursion 162 0 Envelope loss/gain 18694 7823 430 62 12 a)Infiltration 6806 694 210 21 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 4 920 0 0 Appliances/other 3400 0 Subtotal (lines 6 to 13)25500 12837 640 84 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 -640 -84 14 Subtotal 25500 12837 0 0 15 Duct loads 6%2%1438 311 23%19%0 0 Total room load 26938 13148 0 0 Air required (cfm)Air required (cfm)665 665 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 41...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit F AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Laundry F Stairs/Hall F 2 Exposed wall 0 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft6.0x6.3 ft162.2x1.0 5 Room area 37.5 f t²162.2 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 24.5424.54 47.4247.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 38 38 58 32 162 162 249 137 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 162 162 274 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -1 0 Envelope loss/gain 58 31 522 136 12 a)Infiltration 0 0 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)58 531 522 136 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -58 -531 -522 -136 14 Subtotal 0 0 0 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 0 0 Air required (cfm)Air required (cfm)0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 42...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit F AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Pantry F Powder F 2 Exposed wall 10.5 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft5.8x4.8 ft6.0x5.0 5 Room area 27.3 f t²30.0 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 43 43 213 21 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 52 52 258 25 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 24.5424.54 47.4247.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 0 0 0 0 0 0 0 0 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 27 11 169 0 30 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 640 45 0 0 12 a)Infiltration 353 36 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)993 81 0 0 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -993 -81 0 0 14 Subtotal 0 0 0 0 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 0 0 Air required (cfm)Air required (cfm)0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 43...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit F AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Kit/Din/Family F Bedroom 2 F 2 Exposed wall 79.8 ft 25.8 ft 3 Room height 10.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft629.4x1.0 ft13.5x10.5 5 Room area 629.4 f t²141.8 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 236 184 919 89 95 75 371 36 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 10 0 245 113 20 0 491 226 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 42 42 1256 305 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 34 34 168 16 16 16 79 8 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 234 135 673 65 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 78 0 1914 2373 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 21 21 628 152 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 259 234 1165 112 122 122 606 58 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 24.5424.54 47.4247.42 25 0 614 1186 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 77 77 119 65 142 142 217 119 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 142 142 326 9 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 629 80 1285 0 0 0 0 0 6 c) AED excursion 11 -1 Envelope loss/gain 8986 4486 2090 455 12 a)Infiltration 2848 290 865 88 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 1 230 Appliances/other 2900 0 Subtotal (lines 6 to 13)11835 7677 2956 774 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 993 81 378 57 14 Subtotal 12828 7758 3333 830 15 Duct loads -0%0%0 0 23%19%758 157 Total room load 12828 7758 4091 987 Air required (cfm)Air required (cfm)317 392 101 50 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 44...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit F AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Bedroom 3 F 3 F WIC 2 Exposed wall 22.3 ft 0.8 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft11.8x10.5 ft5.5x5.3 5 Room area 123.4 f t²28.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 95 75 371 36 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 20 0 491 226 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 106 106 527 51 7 7 34 3 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 24.5424.54 47.4247.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 123 123 189 104 29 29 44 24 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 123 123 284 8 27 27 61 2 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -1 0 Envelope loss/gain 1863 424 139 29 12 a)Infiltration 748 76 25 3 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2610 730 164 32 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 71 19 146 38 14 Subtotal 2682 748 310 70 15 Duct loads 23%19%610 141 23%19%70 13 Total room load 3292 890 381 83 Air required (cfm)Air required (cfm)81 45 9 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 45...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit F AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name Bath F Master F 2 Exposed wall 9.8 ft 32.8 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft9.8x6.3 ft15.5x16.3 5 Room area 60.9 f t²251.9 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 9 9 45 4 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 0 0 0 0 146 116 580 56 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 0 0 0 0 30 0 736 913 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 88 88 437 42 140 140 695 67 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 24.5424.54 47.4247.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 61 61 93 51 252 252 386 212 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 0 101 Envelope loss/gain 531 93 2443 1353 12 a)Infiltration 328 33 1101 112 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)859 127 3543 1925 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 452 76 99 397 14 Subtotal 1311 203 3642 2322 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1311 203 3642 2322 Air required (cfm)Air required (cfm)32 10 90 117 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-21 19:43:29Right-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 46...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Right-J® W or ksheet 4/20/2020Date:Unit F AH Gene MillerBy:6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net 1 Room name M Bath F M WIC F 2 Exposed wall 9.8 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft11.0x9.8 ft50.3x1.0 5 Room area 107.3 f t²50.3 f t² Ty Construction U-value Or HTM Area (f t²)Load Area (f t²)Load number (Bt uh/f t²-°F)(Bt uh/f t²-°F)(Bt uh/f t²)(Bt uh/f t²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nn 4.994.99 0.480.48 0 0 0 0 0 0 0 0 .GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 nn 24.5424.54 11.3211.32 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 .WW 12F-0sw12F-0sw 0.0650.065 ee 4.994.99 0.480.48 0 0 0 0 0 0 0 0 1 1 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ss 4.994.99 0.480.48 88 72 358 35 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ss 24.5424.54 30.4230.42 16 0 393 487 0 0 0 0 DD 11D011D0 0.3900.390 ss 29.9129.91 7.257.25 0 0 0 0 0 0 0 0 WW 12F-0sw12F-0sw 0.0650.065 ww 4.994.99 0.480.48 0 0 0 0 0 0 0 0 GG 2 glazing, clr low-e 0.3202 glazing, clr low-e 0.320 ww 24.5424.54 47.4247.42 0 0 0 0 0 0 0 0 CC 16B-50ad16B-50ad 0.0200.020 --1.531.53 0.840.84 107 107 165 90 50 50 77 42 FF 20P-38t20P-38t 0.0300.030 --2.302.30 0.060.06 0 0 0 0 0 0 0 0 FF 21A-28v21A-28v 0.0220.022 --1.691.69 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10vpl22B-10vpl 0.2100.210 --16.1116.11 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 54 0 Envelope loss/gain 915 666 77 42 12 a)Infiltration 328 33 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1243 699 77 42 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 74 164 14 Subtotal 1243 699 151 207 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 1243 699 151 207 Air required (cfm)Air required (cfm)31 35 4 10 Job #: Kartchnet 6 Plex Performed by Gene Miller for: Sprinter Heating & Hydronics 3846 East 100 North Rigby, ID 83442 Mechanical Compliance Solutions 4181 Aschli lane Idaho Falls, ID 83406 Phone: 208-881-3243 1sgmiller@cableone.net Scale: 1 : 272 Page 1 Right-Suite® Univ er s al 2019 19.0.12 RSU28163 2020-Apr-21 19:44:28 ... townhome 3\Kartchner 6 Plex.rup N Main Pantry A Powder A Kit/din/Family A Pantry C Powder C Kit/Din/Family C Pantry B Powder B Kit/Din/Family B Pantry D Powder D Kit/Din/Family D Pantry F Powder F Kit/Din/Family F Pantry E Powder E Kit/Din/Family E 113 cfm113 cfm 113 cfm 113 cfm 109 cfm 109 cfm 109 cfm 109 cfm 109 cfm 109 cfm 98 cfm 109 cfm 109 cfm 109 cfm 109 cfm 109 cfm 94 cfm 94 cfm 451 cfm 434 cfm 434 cfm 434 cfm 392 cfm6 " 6 " 6 " 2-14x3.25 6 " 14x3.25 2-14x3.25 8 x 8 8 x 8 6 " 6 " 6 " 6 " 6 " 14x3.25 14x3.25 12 x 8 12 x 8 8 x 8 6 " 8 " 6 " 6 " 6 " 6 " 14x3.25 14x3.25 8 x 8 8 x 8 18 x 8 18 x 8 2-14x3.25 6 " 8 " 14x3.25 6 " 6 " 6 " 6 " 14x3.25 12 x 8 8 x 8 8 x 8 14x3.25 14x3.25 6 " 8 " 6 " 6 " 6 " 14x3.25 8 x 8 18 x 8 3-14x3.25 14x3.25 8 "6 " 2-14x3.25 6 " 8 " 6 " 6 " 12 x 8 8 " 3-14x3.25 8 " 6 " 6 " 8 " 8 " 8 "8 " 14x3.25 8 " 8 " 3-14x3.25 8 " 8 " 14x3.25 8 "8 "6 " 8 " 14x3.25 8 " 8 " 6 "8 " 6 " 8 " 6 " 6 " 8 " 16 x 8 14x3.25 6 " 12 x 8 8 x 8 6 " 14x3.25 8 x 9 18 x 8 6 " 14x3.25 6 " 14x3.25 3-14x3.25 12 x 8 8 x 8 14x3.25 8 x 8 14x3.25 378 cfm 2-14x3.25 14x3.25 18 x 8 6 " 109 cfm6 "94 cfm 8 "6 "94 cfm8 "6 "98 cfm 8 " 98 cfm 8 " 98 cfm8 " Job #: Kartchnet 6 Plex Performed by Gene Miller for: Sprinter Heating & Hydronics 3846 East 100 North Rigby, ID 83442 Mechanical Compliance Solutions 4181 Aschli lane Idaho Falls, ID 83406 Phone: 208-881-3243 1sgmiller@cableone.net Scale: 1 : 272 Page 2 Right-Suite® Univ er s al 2019 19.0.12 RSU28163 2020-Apr-21 19:44:29 ... townhome 3\Kartchner 6 Plex.rup N 2nd Floor Mech Bedroom 2 A Bedroom 3 A 3A WIC Open A Bath A Master A M Bath A M WIC A Laundry A Stairs/Hall A Mech B Bedroom 2BBedroom 3 B 3 B WIC Open B Bath B Master B M Bath B M WIC B Laundry B Stairs/Hall B Mech C Bedroom 2 C Bedroom 3 C 3 C WIC Open C Bath C Master C M Bath C M WIC C Laundry C Stairs/Hall C Mech D Bedroom 2 DBedroom 3 D 3 D WIC Open D Bath D Master D M Bath D M WIC D Laundry D Stairs/Hall D Mech E Bedroom 2 E Bedroom 3 E 3 E WIC Open E Bath E Master E M Bath E M WIC E Laundry E Stairs/Hall E Mech F Bedroom 2 FBedroom 3 F 3 F WIC Open F Bath F Master F M Bath F M WIC F Laundry F Stairs/Hall F 40 cfm 33 cfm 8 cfm 46 cfm 35 cfm 68 cfm 68 cfm 10 cfm 32 cfm 102 cfm 13 cfm 87 cfm 41 cfm 46 cfm 12 cfm 14 cfm 10 cfm 10 cfm 13 cfm 14 cfm 4 cfm 72 cfm 72 cfm 72 cfm 72 cfm 46 cfm 14 cfm 10 cfm 10 cfm 13 cfm 9 cfm 101 cfm 81 cfm114 cfm 87 cfm85 cfm 112 cfm114 cfm 87 cfm 82 cfm 32 cfm 32 cfm10 cfm90 cfm10 cfm 10 cfm 188 cfm 102 cfm 92 cfm 203 cfm 128 cfm 114 cfm 87 cfm 87 cfm 128 cfm 203 cfm 72 cfm 94 cfm 203 cfm 163 cfm 123 cfm 85 cfm 11 cfm 87 cfm 128 cfm 91 cfm 101 cfm 52 cfm 72 cfm52 cfm 59 cfm59 cfm 32 cfm 2020-Apr-21 19:43:33 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 1 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Duct System Summary 4/20/2020Date:Unit A AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 CoolingHeating External static pressure in H2O0.90in H2O0.90 Pressure losses in H2O0.41in H2O0.41 Available static pressure in H2O0.49in H2O0.49 Supply / return available pressure 0.227 / 0.263 in H2O in H2O0.227 / 0.263 Lowest friction rate in/100ft0.116in/100ft0.116 Actual air flow cfm767cfm665 Total effective length (TEL)ft423 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st12150.021.3VlFx0x06.00.132510387h3A WIC st11175.04.8VlFx0x06.00.12612321311hBath A st12105.019.5VlFx0x06.00.182591024160hBedroom 2 A st12140.028.5VlFx0x06.00.13453823346hBedroom 3 A st11105.026.5VlFx0x08.00.172113791917cKit/din/Family A st11150.041.3VlFx0x08.00.118113791917cKit/din/Family A-A st12160.023.5VlFx0x08.00.123113791917cKit/din/Family A-B st11175.08.5VlFx0x08.00.123113791917cKit/din/Family A-C st11160.033.5VlFx0x06.00.1174131693cM Bath A st11165.030.5VlFx0x06.00.116124205cM WIC A 00VlFx0x00068451151cMaster A st11140.034.3VlFx0x06.00.13068451151cMaster A-A Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st11 Peak AVF 348 470 0.116 706 10.1 12x8 ShtMetl st12 Peak AVF 273 229 0.123 614 8.1 8x8 ShtMetl 2020-Apr-21 19:43:33 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 2 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb1 0x 320 12 91.8 0.287 102 3.1 3.25x14 10x9 SJSp rt11 rb7 0x 1240 188 227.3 0.116 298 7.2 2-3.25x14 2-10x18 SJSp rt11 rb8 0x 1020 59 138.0 0.191 323 5.2 3.25x14 10x9 SJSp rt12 rb9 0x 920 58 210.3 0.125 290 5.4 3.25x14 10x9 SJSp rt12 rb26 0x 3150 451 201.8 0.131 476 9.7 3-3.25x14 3-10x27 SJSp rt11 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt11 Peak AVF 471 651 0.116 651 11.4 18x8 ShtMetl rt12 Peak AVF 194 116 0.125 436 7.1 8x8 ShtMetl 2020-Apr-21 19:43:33 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 3 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Duct System Summary 4/20/2020Date:Unit B AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 CoolingHeating External static pressure in H2O0.90in H2O0.90 Pressure losses in H2O0.41in H2O0.41 Available static pressure in H2O0.49in H2O0.49 Supply / return available pressure 0.227 / 0.263 in H2O in H2O0.227 / 0.263 Lowest friction rate in/100ft0.115in/100ft0.115 Actual air flow cfm767cfm665 Total effective length (TEL)ft425 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st10150.022.0VlFx0x06.00.132613413h3 B WIC st9175.05.5VlFx0x06.00.126710301hBath B st10105.020.5VlFx0x06.00.18157872700hBedroom 2B st10140.029.3VlFx0x08.00.134601143569hBedroom 3 B st9130.044.3VlFx0x08.00.130109801658cKit/Din/Family B st9150.027.3VlFx0x08.00.128109801658cKit/Din/Family B-A st9175.010.3VlFx0x08.00.123109801658cKit/Din/Family B-B st10160.023.8VlFx0x08.00.124109801658cKit/Din/Family B-C st9160.033.8VlFx0x06.00.1174640699cM Bath B st9165.032.0VlFx0x06.00.115145207cM WIC B st9140.035.5VlFx0x06.00.12972391101cMaster B 00VlFx0x00072391101cMaster B-A Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st10 Peak AVF 294 231 0.124 661 8.3 8x8 ShtMetl st9 Peak AVF 332 464 0.115 695 10.0 12x8 ShtMetl 2020-Apr-21 19:43:33 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 4 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb2 0x 100 7 91.8 0.286 30 2.0 3.25x14 10x9 SJSp rt9 rb10 0x 1220 203 227.8 0.115 322 7.4 2-3.25x14 2-10x18 SJSp rt9 rb11 0x 1280 66 139.5 0.188 404 5.6 3.25x14 10x9 SJSp rt10 rb12 0x 870 57 210.3 0.125 274 5.3 3.25x14 10x9 SJSp rt10 rb27 0x 3190 434 202.3 0.130 458 9.6 3-3.25x14 3-10x27 SJSp rt9 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt10 Peak AVF 214 123 0.125 482 7.4 8x8 ShtMetl rt9 Peak AVF 451 644 0.115 644 11.3 18x8 ShtMetl 2020-Apr-21 19:43:33 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 5 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Duct System Summary 4/20/2020Date:Unit C AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 CoolingHeating External static pressure in H2O0.90in H2O0.90 Pressure losses in H2O0.41in H2O0.41 Available static pressure in H2O0.49in H2O0.49 Supply / return available pressure 0.219 / 0.271 in H2O in H2O0.219 / 0.271 Lowest friction rate in/100ft0.120in/100ft0.120 Actual air flow cfm767cfm665 Total effective length (TEL)ft410 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st8150.021.5VlFx0x06.00.128613413h3 C WIC st7165.05.0VlFx0x06.00.129710301hBath C st8105.019.3VlFx0x06.00.17657872700hBedroom 2 C st8140.029.3VlFx0x08.00.129601143569hBedroom 3 C st7130.043.8VlFx0x08.00.126109801658cKit/Din/Family C st7130.027.5VlFx0x08.00.139109801658cKit/Din/Family C-A st7160.08.5VlFx0x08.00.130109801658cKit/Din/Family C-B st8160.023.0VlFx0x08.00.120109801658cKit/Din/Family C-C st7140.041.5VlFx0x06.00.1204640699cM Bath C st7150.031.5VlFx0x06.00.120145207cM WIC C 00VlFx0x00072391101cMaster C st7130.034.8VlFx0x06.00.13372391101cMaster C-A Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st8 Peak AVF 294 231 0.120 661 8.4 8x8 ShtMetl st7 Peak AVF 332 464 0.120 695 9.9 12x8 ShtMetl 2020-Apr-21 19:43:33 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 6 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb3 0x 100 7 92.5 0.293 30 2.0 3.25x14 10x9 SJSp rt7 rb13 0x 870 57 123.3 0.220 274 4.7 3.25x14 10x9 SJSp rt8 rb14 0x 1280 66 105.5 0.257 404 5.3 3.25x14 10x9 SJSp rt8 rb15 0x 1220 203 227.0 0.120 322 7.3 2-3.25x14 2-10x18 SJSp rt7 rb29 0x 3190 434 200.3 0.135 458 9.5 3-3.25x14 3-10x27 SJSp rt7 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt7 Peak AVF 451 644 0.120 644 11.3 18x8 ShtMetl rt8 Peak AVF 214 123 0.220 482 6.6 8x8 ShtMetl 2020-Apr-21 19:43:33 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 7 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Duct System Summary 4/20/2020Date:Unit D AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 CoolingHeating External static pressure in H2O0.90in H2O0.90 Pressure losses in H2O0.41in H2O0.41 Available static pressure in H2O0.49in H2O0.49 Supply / return available pressure 0.223 / 0.267 in H2O in H2O0.223 / 0.267 Lowest friction rate in/100ft0.114in/100ft0.114 Actual air flow cfm665cfm665 Total effective length (TEL)ft431 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st6150.021.8VlFx0x06.00.130411347h3 D WIC st5175.06.3VlFx0x06.00.12358261hBath D st6105.020.3VlFx0x06.00.17848852620hBedroom 2 D st6140.028.8VlFx0x08.00.132511123466hBedroom 3 D st5130.044.3VlFx0x08.00.12894801658cKit/Din/Family D st5175.08.5VlFx0x08.00.12194801658cKit/Din/Family D-A st6160.023.5VlFx0x08.00.12194801658cKit/Din/Family D-B st5130.030.3VlFx0x08.00.13994801658cKit/Din/Family D-C st5175.016.5VlFx0x06.00.116337572cLaundry D st5160.034.5VlFx0x06.00.11440401243hM Bath D st5165.031.0VlFx0x06.00.11434118hM WIC D st5150.034.8VlFx0x06.00.1215238908cMaster D st5140.029.0VlFx0x06.00.1325238908cMaster D-A Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st5 Peak AVF 377 467 0.114 701 10.1 12x8 ShtMetl st6 Peak AVF 288 198 0.121 648 8.3 8x8 ShtMetl 2020-Apr-21 19:43:33 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 8 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb4 0x 540 90 91.5 0.292 283 4.5 3.25x14 10x9 SJSp rt5 rb17 0x 820 94 228.3 0.117 299 5.5 3.25x14 10x9 SJSp rt5 rb20 0x 1230 55 139.3 0.192 390 5.5 3.25x14 10x9 SJSp rt6 rb21 0x 850 48 210.0 0.127 268 5.2 3.25x14 10x9 SJSp rt6 rb30 0x 3210 378 235.3 0.114 597 9.3 2-3.25x14 2-10x18 SJSp rt5 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt5 Peak AVF 457 562 0.114 562 10.8 18x8 ShtMetl rt6 Peak AVF 208 103 0.127 468 7.3 8x8 ShtMetl 2020-Apr-21 19:43:33 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 9 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Duct System Summary 4/20/2020Date:Unit E AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 CoolingHeating External static pressure in H2O0.90in H2O0.90 Pressure losses in H2O0.41in H2O0.41 Available static pressure in H2O0.49in H2O0.49 Supply / return available pressure 0.245 / 0.245 in H2O in H2O0.245 / 0.245 Lowest friction rate in/100ft0.120in/100ft0.120 Actual air flow cfm767cfm665 Total effective length (TEL)ft407 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st4150.021.8VlFx0x06.00.143613413h3 E WIC st3175.05.5VlFx0x06.00.136710301hBath E st4130.019.5VlFx0x06.00.16457872700hBedroom 2 E st4140.028.0VlFx0x08.00.146601143569hBedroom 3 E st4160.023.3VlFx0x08.00.134109801658cKit/Din/Family E st3175.08.0VlFx0x08.00.134109801658cKit/Din/Family E-A st3150.044.0VlFx0x08.00.126109801658cKit/Din/Family E-B st3175.027.8VlFx0x08.00.121109801658cKit/Din/Family E-C st3160.043.3VlFx0x06.00.1204640699cM Bath E st3165.031.3VlFx0x06.00.125145207cM WIC E st3140.028.3VlFx0x06.00.14672391101cMaster E st3140.034.3VlFx0x06.00.14172391101cMaster E-A Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st4 Peak AVF 294 231 0.134 661 8.2 8x8 ShtMetl st3 Peak AVF 371 536 0.120 804 10.5 12x8 ShtMetl 2020-Apr-21 19:43:33 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 10 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb5 0x 100 7 94.0 0.261 30 2.0 3.25x14 10x9 SJSp rt3 rb18 0x 1220 203 139.0 0.176 644 6.8 3.25x14 10x9 SJSp rt3 rb22 0x 870 57 125.3 0.196 274 4.8 3.25x14 10x9 SJSp rt4 rb23 0x 1280 66 107.0 0.229 404 5.4 3.25x14 10x9 SJSp rt4 rb31 0x 3190 434 203.5 0.120 458 9.7 3-3.25x14 3-10x27 SJSp rt3 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt3 Peak AVF 451 644 0.120 644 11.3 18x8 ShtMetl rt4 Peak AVF 214 123 0.196 482 6.8 8x8 ShtMetl 2020-Apr-21 19:43:33 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 11 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Kartchnet 6 PlexJob:Duct System Summary 4/20/2020Date:Unit F AH Gene MillerBy: 6 PlexPlan:Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: 1sgmiller@cableone.net Project Information Sprinter Heating & HydronicsFor: 3846 East 100 North, Rigby, ID 83442 CoolingHeating External static pressure in H2O0.90in H2O0.90 Pressure losses in H2O0.41in H2O0.41 Available static pressure in H2O0.49in H2O0.49 Supply / return available pressure 0.233 / 0.257 in H2O in H2O0.233 / 0.257 Lowest friction rate in/100ft0.113in/100ft0.113 Actual air flow cfm665cfm665 Total effective length (TEL)ft435 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st2150.022.3VlFx0x06.00.13549381h3 F WIC st1175.06.0VlFx0x06.00.12910321311hBath F st2105.019.8VlFx0x06.00.187501014091hBedroom 2 F st2140.029.3VlFx0x06.00.13845813292hBedroom 3 F st2160.022.3VlFx0x08.00.12898791939cKit/Din/Family F st1175.08.3VlFx0x08.00.12798791939cKit/Din/Family F-A st1160.029.0VlFx0x08.00.12398791939cKit/Din/Family F-B st1150.042.8VlFx0x08.00.12198791939cKit/Din/Family F-C st1165.034.0VlFx0x06.00.1173531699cM Bath F st1175.031.8VlFx0x06.00.113104207cM WIC F st1130.027.8VlFx0x06.00.14859451161cMaster F st1140.035.0VlFx0x06.00.13359451161cMaster F-A Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st2 Peak AVF 271 197 0.128 542 8.0 8x9 ShtMetl st1 Peak AVF 394 468 0.113 702 10.1 12x8 ShtMetl 2020-Apr-21 19:43:33 Rig ht-Su ite® U niv er sal 20 19 19 .0.12 RSU2 8163 Page 12 ...inter\Kartchner townhome 3\Kartchner 6 Plex.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb6 0x 320 10 92.0 0.279 102 3.1 3.25x14 10x9 SJSp rt1 rb19 0x 1240 163 228.0 0.113 517 6.8 3.25x14 10x9 SJSp rt1 rb24 0x 910 49 139.3 0.185 287 5.0 3.25x14 10x9 SJSp rt2 rb25 0x 1010 50 210.3 0.122 320 5.6 3.25x14 10x9 SJSp rt2 rb32 0x 3170 392 201.8 0.127 621 9.2 2-3.25x14 2-10x18 SJSp rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 473 566 0.113 637 10.9 16x8 ShtMetl rt2 Peak AVF 192 99 0.122 431 7.1 8x8 ShtMetl