Loading...
HomeMy WebLinkAboutRESCHECK - 20-00254 - 848 & 854 S 2400 W - Summerfield TwinhomesREScheck Software Version 4.6.5 Compliance Certificate Project Kartchner town home 4 Energy Code:2015 IECC Location:Idaho Falls, Idaho Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:3,125 ft2 Glazing Area 15% Climate Zone:6 (7918 HDD) Permit Date: Construction Site:Owner/Agent: Sprinter Heating & Hydronics Designer/Contractor: Mechanical Compliance Solutions Mechanical Compliance Solutions 4181 Aschli lane Idaho Falls, ID 83406 208-881-3243 1sgmiller@cableone.net Permit Number: Compliance: Passes using UA trade-off 5.3% Better Than Code Maximum UA:417 Your UA:395 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Wall 1: Wood Frame, 16" o.c.434 21.0 0.0 0.057 22 Door 1: Solid 21 0.140 3 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 25 0.320 8 Wall 2: Wood Frame, 16" o.c.720 21.0 0.0 0.057 25 Door 1: Solid 42 0.140 6 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 236 0.320 76 Wall 3: Wood Frame, 16" o.c.434 21.0 0.0 0.057 22 Door 1: Solid 21 0.140 3 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 25 0.320 8 Wall 4: Wood Frame, 16" o.c.720 21.0 0.0 0.057 35 Door 1: Solid 42 0.140 6 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 60 0.320 19 Floor 1: All-Wood Joist/Truss:Over Outside Air 3,125 38.0 0.0 0.026 81 Ceiling 1: Flat Ceiling or Scissor Truss 3,125 50.0 0.0 0.026 81 Project Title: Kartchner town home 4 Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Kartchner town home 4.rck Page 1 of 2 04/20/20Report date: Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Notes: Job Number: Ammon Retrofit INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Project Title: Kartchner town home 4 Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Kartchner town home 4.rck Page 2 of 2 04/20/20Report date: