HomeMy WebLinkAboutRESCHECK - 20-00252 - 808 & 824 S 2400 W - Summerfield TwinhomesREScheck Software Version 4.6.5
Compliance Certificate
Project Kartchner town home 4
Energy Code:2015 IECC
Location:Idaho Falls, Idaho
Construction Type:Single-family
Project Type:New Construction
Conditioned Floor Area:3,125 ft2
Glazing Area 15%
Climate Zone:6 (7918 HDD)
Permit Date:
Construction Site:Owner/Agent:
Sprinter Heating & Hydronics
Designer/Contractor:
Mechanical Compliance Solutions
Mechanical Compliance Solutions
4181 Aschli lane
Idaho Falls, ID 83406
208-881-3243
1sgmiller@cableone.net
Permit Number:
Compliance: Passes using UA trade-off
5.3% Better Than Code Maximum UA:417 Your UA:395
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Wall 1: Wood Frame, 16" o.c.434 21.0 0.0 0.057 22
Door 1: Solid 21 0.140 3
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 25 0.320 8
Wall 2: Wood Frame, 16" o.c.720 21.0 0.0 0.057 25
Door 1: Solid 42 0.140 6
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 236 0.320 76
Wall 3: Wood Frame, 16" o.c.434 21.0 0.0 0.057 22
Door 1: Solid 21 0.140 3
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 25 0.320 8
Wall 4: Wood Frame, 16" o.c.720 21.0 0.0 0.057 35
Door 1: Solid 42 0.140 6
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 60 0.320 19
Floor 1: All-Wood Joist/Truss:Over Outside Air 3,125 38.0 0.0 0.026 81
Ceiling 1: Flat Ceiling or Scissor Truss 3,125 50.0 0.0 0.026 81
Project Title: Kartchner town home 4
Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Kartchner town home 4.rck Page 1 of 2
04/20/20Report date:
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Notes:
Job Number: Ammon Retrofit
INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE
VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID.
Project Title: Kartchner town home 4
Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\Kartchner town home 4.rck Page 2 of 2
04/20/20Report date: