HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00242 - 964 S 2275 W - New SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 04/16/2020 8:52 am
Permit Details Permit Number: 11-00242
964 S 2275 W - New SFR
964 S 2275 W
New Single Family Residence
Permit Issued Date: 09/26/2014
Permit Inspection Statistics
20Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 85.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building
09/14/2011PassTed DyeResidential Footing Inspection
All overlaps look good
Ufer on north wall towards front
Inspector Comments:
09/16/2011PassTed DyeFoundation Inspection
10/10/2011PassTed DyeSheeting
Sheeting only OK for cover.Inspector Comments:
10/14/2011FailTed DyeResidential Framing/Structure Inspection
Bearing walls need anchor bolts 6' on centerInspector Comments:
10/18/2011PassTed DyeResidential Framing/Structure Inspection
10/19/2011PassPLL ADMINResidential Insulation Inspection
As per Jon Berry
Keep insulation 1" away from insulation
OK to cover.
Inspector Comments:
10/21/2011PassPLL ADMINResidential Sheetrock/Drywall Inspection
As per Jon Berry
OK Basement not completed
Inspector Comments:
10/21/2011PassPLL ADMINSidewalk Inspection
As per Jon Berry
Sidewalk OK to pour.
Inspector Comments:
11/28/2011FailTed DyeResidential Building Final
house # missing
suggested that interior attic access needs to start having interior weather seal.
call when completed.
unfinished basement
INUATION basement walls R-11; rim joist R-22; extior walls R-22; Attic R-50
Inspector Comments:
01/10/2012PassTed DyeResidential Building Final
All items correctedInspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 11-00242
964 S 2275 W - New SFR
964 S 2275 W
New Single Family Residence
Permit Status of (Open) as of Report Date: 04/16/2020 8:52 am
Permit
Inspection
Summary
Electrical
09/23/2011PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power.Inspector Comments:
10/13/2011PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover as per Jane Shaw.Inspector Comments:
11/21/2011PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-unfinished basement, No A/C unit (30A OCPD).Inspector Comments:
Mechanical
10/17/2011PassPLL ADMINHVAC Rough-in
As per Jon Berry
HVAC rough looks good.
Inspector Comments:
11/23/2011FailPLL ADMINHVAC Final Inspection
As per Jon Berry
Kitchen dining area cold with basement and upstairs areas 70 degrees- only 1
register. Ducting not per submitted plans
Inspector Comments:
01/13/2012PassPLL ADMINHVAC Final Inspection
As per Jon Berry
PCW submitted new calc's
Inspector Comments:
Plumbing
09/23/2011PassDon AllenPlumbing Sewer
sewer is all good to coverInspector Comments:
09/23/2011PassDon AllenPlumbing Underground Inspection
ground work is all good to coverInspector Comments:
10/22/2011PassDon AllenPlumbing Water
11/22/2011PassDon AllenPlumbing Final Inspection
all good for the finalInspector Comments:
Page 2 of 2