Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00242 - 964 S 2275 W - New SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 04/16/2020 8:52 am Permit Details Permit Number: 11-00242 964 S 2275 W - New SFR 964 S 2275 W New Single Family Residence Permit Issued Date: 09/26/2014 Permit Inspection Statistics 20Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 85.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 09/14/2011PassTed DyeResidential Footing Inspection All overlaps look good Ufer on north wall towards front Inspector Comments: 09/16/2011PassTed DyeFoundation Inspection 10/10/2011PassTed DyeSheeting Sheeting only OK for cover.Inspector Comments: 10/14/2011FailTed DyeResidential Framing/Structure Inspection Bearing walls need anchor bolts 6' on centerInspector Comments: 10/18/2011PassTed DyeResidential Framing/Structure Inspection 10/19/2011PassPLL ADMINResidential Insulation Inspection As per Jon Berry Keep insulation 1" away from insulation OK to cover. Inspector Comments: 10/21/2011PassPLL ADMINResidential Sheetrock/Drywall Inspection As per Jon Berry OK Basement not completed Inspector Comments: 10/21/2011PassPLL ADMINSidewalk Inspection As per Jon Berry Sidewalk OK to pour. Inspector Comments: 11/28/2011FailTed DyeResidential Building Final house # missing suggested that interior attic access needs to start having interior weather seal. call when completed. unfinished basement INUATION basement walls R-11; rim joist R-22; extior walls R-22; Attic R-50 Inspector Comments: 01/10/2012PassTed DyeResidential Building Final All items correctedInspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 11-00242 964 S 2275 W - New SFR 964 S 2275 W New Single Family Residence Permit Status of (Open) as of Report Date: 04/16/2020 8:52 am Permit Inspection Summary Electrical 09/23/2011PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 10/13/2011PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover as per Jane Shaw.Inspector Comments: 11/21/2011PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-unfinished basement, No A/C unit (30A OCPD).Inspector Comments: Mechanical 10/17/2011PassPLL ADMINHVAC Rough-in As per Jon Berry HVAC rough looks good. Inspector Comments: 11/23/2011FailPLL ADMINHVAC Final Inspection As per Jon Berry Kitchen dining area cold with basement and upstairs areas 70 degrees- only 1 register. Ducting not per submitted plans Inspector Comments: 01/13/2012PassPLL ADMINHVAC Final Inspection As per Jon Berry PCW submitted new calc's Inspector Comments: Plumbing 09/23/2011PassDon AllenPlumbing Sewer sewer is all good to coverInspector Comments: 09/23/2011PassDon AllenPlumbing Underground Inspection ground work is all good to coverInspector Comments: 10/22/2011PassDon AllenPlumbing Water 11/22/2011PassDon AllenPlumbing Final Inspection all good for the finalInspector Comments: Page 2 of 2