HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00257 - 2483 W 960 S - Kartchner Townhomes (6)Permit Inspection Summary Permit Status of (Open) as of Report Date: 04/16/2020 8:27 am Permit Details Permit Number: 11-00257 2483 W 960 S - Kartchner Townhomes (6) 2483 W 960 S New Single Family Residence Permit Issued Date: 09/29/2014 Permit Inspection Statistics 27Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 62.96% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 08/17/2011PassTed DyeResidential Footing Inspection ufer ground in east wall close to front of buildingInspector Comments: 08/19/2011PassTed DyeFoundation Inspection 10/04/2011PassTed DyeSheeting Sheeting only # 2465 Sheeting OK # 2471 Nails missing on exterior wall at North bedroom (marked with red crayon) # 2477 OK # 2483 Nailing missing in north bedroom # 2489 Nailing missing in north bedroom #2495 Nailing missing in South West bedroom Inspector Comments: 10/19/2011FailTed DyeResidential Framing/Structure Inspection Firecaulk gaps in firewall. Double stud under girder truss. attic access? Tempered windows at top & bottom of stairs. Inspector Comments: 10/19/2011FailPLL ADMINResidential Framing/Structure Inspection As per Jon Berry Seal holes in attic party walls. Inspector Comments: 10/20/2011PassPLL ADMINResidential Framing/Structure Inspection As per Jon Berry Seal holes in attic party walls. Trusses need clips at walls east unit. *approved Inspector Comments: 10/21/2011FailPLL ADMINResidential Insulation Inspection As per Jon Berry Insulate ceilings at exterior walls 1st floor. Inspector Comments: 10/25/2011PassQuinton OwensResidential Insulation Inspection Insulation OK to cover.Inspector Comments: Page 1 of 4 (Continued) Permit Details Permit Number: 11-00257 2483 W 960 S - Kartchner Townhomes (6) 2483 W 960 S New Single Family Residence Permit Status of (Open) as of Report Date: 04/16/2020 8:27 am Permit Inspection Summary 11/02/2011FailTed DyeResidential Sheetrock/Drywall Inspection #2 and #4 units have 1/2" sheetrock in front coat closet on the separation wall. It needs to be replaced with 5/8" fire code sheetrock. #3 Ok Inspector Comments: 11/02/2011PassQuinton OwensResidential Sheetrock/Drywall Inspection 10/25/11 - Unit 1 only. 10/26/11 - 2489 W. #5 ONLY 11/2/11 - #3 Ok *approved. Inspector Comments: 11/02/2011PassTed DyeSidewalk Inspection sidewalk in front of the 6-plex and on the west side has 6" of fine compacted gravel OK to cover. Inspector Comments: 12/15/2011FailQuinton OwensResidential Building Final 2495: Step out back door too high; handrail not installed; metal covers on cleanouts in garage. 2465: Step out back door too high; metal covers on cleanouts in garage. Inspector Comments: 12/23/2011FailPLL ADMINResidential Building Final As per Jon Berry Fire caulk around furnace and piping in back wall Inspector Comments: 01/06/2012PassQuinton OwensResidential Building Final 2465 & 2495 approved 12-16-11 QO 2471, 2477, & 2483 approved 12-22-11 QO 2489 approved (mech. closet not part of any firewall, no firecaulk req'd) - QO & JB Inspector Comments: Page 2 of 4 (Continued) Permit Details Permit Number: 11-00257 2483 W 960 S - Kartchner Townhomes (6) 2483 W 960 S New Single Family Residence Permit Status of (Open) as of Report Date: 04/16/2020 8:27 am Permit Inspection Summary Electrical 09/23/2011FailBret StoddardResidential Electrical Service Inspection Service is not ready or completed to have energized.Inspector Comments: 10/21/2011PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-inspected the service on the rough-in inspection-no separate inspection ticket was written. Inspector Comments: 10/21/2011PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 10/19/11 - Approved for cover in units # 2495, 2489, and 2483. 10/21/11 - Approved for cover in units# 2465, 2471, and 2477. Inspector Comments: 12/21/2011FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection #2471-30A breaker for dishwasher and dispose-all circuit, #2477-living room breaker tripping, no A/C units installed on any of them (30A OCPD), call for a re-inspect when ready for these last two. Inspector Comments: 12/22/2011PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection 12/15/11 - Approved for a final and C.O.-units #2465 and #2495 only-A/C units not installed (30A OCPD). 12/21/11 - Approved for a final and C.O. unit #2483 only 12/22/11 - Approved for a final and C.O. unit #2489 only 12/22/11 - Approved for a final and C.O. units #2471, and #2477. Inspector Comments: Mechanical 10/18/2011FailPLL ADMINHVAC Rough-in As per Jon Berry 10/13/11 - Not ready. Seal garage ducting in unit 6 10/19 CW Dryer vents backwards in 1 and 5 10/19 CW Inspector Comments: 10/19/2011PassPLL ADMINHVAC Rough-in As per Jon Berry Only units 2,3, and 4are ok 10/20 Completed HVAC Rough looks good. Inspector Comments: 12/22/2011FailQuinton OwensHVAC Final Inspection 12/15/11 - Step out back door too high. Metal covers needed on clean-outs in garage. 2483 - Gas odor in Furnace closet, strongest by shutoff valve and regulator. Inspector Comments: 01/09/2012PassQuinton OwensHVAC Final Inspection 2465 & 2495 approved 12-15, QO 2471 & 2477 approved 12-22, QO 2489 approved 12-22, JB 2483 No gas smell or leak detected with sensor - approved 1/9 Inspector Comments: Page 3 of 4 (Continued) Permit Details Permit Number: 11-00257 2483 W 960 S - Kartchner Townhomes (6) 2483 W 960 S New Single Family Residence Permit Status of (Open) as of Report Date: 04/16/2020 8:27 am Permit Inspection Summary Plumbing 08/29/2011PassDon AllenPlumbing Sewer the sewer is good for all 6 of the unitsInspector Comments: 09/01/2011PassDon AllenPlumbing Underground Inspection ground work looks good they can coverInspector Comments: 10/13/2011PassDon AllenPlumbing Rough-in all 6 apts are good to cover for the rough inInspector Comments: 12/15/2011PassDon AllenPlumbing Final Inspection Need tape from w/H pan to floor drain. Washer box cover, ice maker cover. Dish washer hook up Wash box needs cover. All 6 apt are good 12/20/11 - All good. Inspector Comments: Page 4 of 4