HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00280 - 491 Morgan Dr - Moving HousePermit Inspection Summary Permit Status of (Open) as of Report Date: 04/13/2020 3:03 pm Permit Details Permit Number: 11-00280 491 Morgan Dr - Moving House 491 Morgan Dr Single Family - Remodel Permit Issued Date: 04/30/2014 Permit Inspection Statistics 28Total Inspections Completed: 22Total Inspections Passed: Inspection Pass Rate: 78.57% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 09/09/2011PassTed DyeFooting Inspection 09/09/2011PassTed DyeFoundation Inspection ufer ground near power conduitsInspector Comments: 08/21/2012PassQuinton OwensFraming/Structure Inspection Basement Framing approved (7-21, Quinton)Inspector Comments: 08/22/2012FailQuinton OwensInsulation Inspection floor joist cavities at porch & garage to be insulated.Inspector Comments: 08/23/2012PassQuinton OwensSheetrock/Drywall Inspection Finish under stairs. Cover back side of wall return air in storage room.Inspector Comments: 02/03/2015PassTed DyeCommercial Insulation Inspection Insulation installed as per codeInspector Comments: 04/18/2016PassQuinton OwensResidential Building Final Basement finish. (complete electrical, plumbing, & mechanical finals for C.O.)Inspector Comments: 04/19/2016PassQuinton OwensCommercial Insulation Inspection Approved by Ted (insulation inspection 2/3/15)Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 11-00280 491 Morgan Dr - Moving House 491 Morgan Dr Single Family - Remodel Permit Status of (Open) as of Report Date: 04/13/2020 3:03 pm Permit Inspection Summary Electrical Approved to be energized for permanent power.Inspector Comments: 12/08/2011PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power.Inspector Comments: 02/14/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover in the basement outside walls only-insulated before it was inspected-noted this on the inspection ticket that was left on the counter in house. Inspector Comments: 05/10/2012FailPLL ADMINSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Need to install all covers in basement area on all boxes, call for a re-inspect when ready, as per Jane Shaw. Inspector Comments: 08/21/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover in the basement-interior walls were wired by the homeowner and all the exterior walls/ceilings were wired by the electrical contractor with the rest of the dwelling when the house was moved. Inspector Comments: 03/23/2015PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 04/20/2016FailBret StoddardElectrical Final Inspection SFR-B,A,R, MFR-A,R Basement final - need the following outlet within 6' of sink need GFCI outlet in storage room needs GFCI Missing covers in kitchen and by fireplace flash rings needed for outlets in beadboard label panel secure light over stage change hallway nightlight to outlet As per Brent Purcell Inspector Comments: 06/26/2017FailBret StoddardElectrical Final Inspection SFR-B,A,R, MFR-A,R 06/27/2017PassBret StoddardResidential Electrical Final Inspection Mechanical 08/21/2012FailQuinton OwensHVAC Rough-in No combustion air vent for Water Heater.(Indoor air requires 50 cuft per 1000 btuh) Inspector Comments: 02/03/2015PassDon AllenHVAC Rough-in fire place in the basement is good to cover.Inspector Comments: 02/03/2015PassDon AllenHVAC Final Inspection fire place in the basement looks goodInspector Comments: 06/26/2017PassDon AllenHVAC Final Inspection Page 2 of 3 (Continued) Permit Details Permit Number: 11-00280 491 Morgan Dr - Moving House 491 Morgan Dr Single Family - Remodel Permit Status of (Open) as of Report Date: 04/13/2020 3:03 pm Permit Inspection Summary Plumbing 09/15/2011PassDon AllenPlumbing Underground Inspection groundwork is good to coverInspector Comments: 02/14/2012FailDon AllenPlumbing Rough-in needs to fix the venting for the master tub and the common tub they tie together 6" above flood rims of the tubs Inspector Comments: 03/26/2012PassDon AllenPlumbing Rough-in 2/14/12 - Rough reinspect - approved. 3/26/12 - venting for the master and main was all fixed good for the c/o Inspector Comments: 05/14/2012PassDon AllenPlumbing Water 05/14/2012PassDon AllenPlumbing Sewer 05/14/2012PassDon AllenPlumbing Final Inspection 02/03/2015PassDon AllenPlumbing Rough-in plumbing rough in for the master bath looks goodInspector Comments: 06/26/2017PassDon AllenPlumbing Final Inspection Page 3 of 3