HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00395 - 820 Yost St - SFRPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 04/13/2020 2:42 pm
Permit Details Permit Number: 11-00395
820 Yost St - SFR
820 Yost St
New Single Family Residence
Permit Issued Date: 11/17/2014
Permit Inspection Statistics
20Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 85.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building
11/21/2011PassTed DyeResidential Footing Inspection
rebar overlaps looked good rebar suspendedInspector Comments:
11/21/2011PassTed DyeFoundation Inspection
ufer installed by electrical conduitInspector Comments:
01/13/2012FailQuinton OwensResidential Framing/Structure Inspection
Sheathing approved 1/4/12 (No holddowns on back left corner as required) Need
Mfr approved fix for joist above laundry room. No hold downs installed as
required on southwest corner. Missing full stud in Northeast corner at elect.
service box. Electrician to move S.D. away from supply air in Mstr Bdrm.
Inspector Comments:
01/23/2012PassQuinton OwensResidential Framing/Structure Inspection
1/4/12 - Sheathing OK to cover. No holddown straps at back left corner as
required.
3/27/12 - Added finished basement. Interior partitions approved.Other framing
inspected with original framing inspection. Bearing alls approved with original
framing.
Several locations missing insulation.
Inspector Comments:
01/23/2012PassQuinton OwensResidential Insulation Inspection
Framing items done. Insulation OK to cover.Inspector Comments:
02/08/2012PassQuinton OwensResidential Sheetrock/Drywall Inspection
Basement drywall approved 4-3, Quinton
Drywall OK to tape- 1/30/12
Inspector Comments:
04/24/2012PassQuinton OwensSidewalk Inspection
6" gravel base.
OK to pour.
Inspector Comments:
05/14/2012FailQuinton OwensResidential Building Final
Rating on beam in garage? (Unprotected with habitable space above) Egress
ladders required in bedroom window wells. Light for upper stairway not working.
Inspector Comments:
05/15/2012PassQuinton OwensResidential Building Final
Building Final OKInspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 11-00395
820 Yost St - SFR
820 Yost St
New Single Family Residence
Permit Status of (Open) as of Report Date: 04/13/2020 2:42 pm
Permit
Inspection
Summary
Electrical
01/13/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-inspected this on the rough-in
inspection, therefore no separate ticket was written for the service inspection.
Inspector Comments:
03/12/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
1/13/12 - Approved for cover-unfinished basement-service inspected with the
rough-in-need to move the smoke alarm box in the master bedroom away from
the supply air duct at least 3 feet-will re-inspect on the final-called and
mentioned to Wayne Van Orden(electrical contractor).
3/27/12 - Approved for cover in the basement.
Inspector Comments:
05/14/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Master bedroom receptacles have reversed polarity, kitchen hallway and laundry
receptacles not working, call for a re-inspect when ready.
Inspector Comments:
05/14/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
5/15/12 - Approved for a final and C.O.-entire house.
5/14/12 - Approved for a final and C.O. Basement only.
Inspector Comments:
Mechanical
01/13/2012PassQuinton OwensHVAC Rough-in
Added exception for finished basement (3-27, QO): 6" combustion air vent is
insufficient for 107,000 btu/hr. Vent openings into main living space will be
required.
Inspector Comments:
05/14/2012PassQuinton OwensHVAC Final Inspection
Mech final approved.Inspector Comments:
Plumbing
12/05/2011PassDon AllenPlumbing Sewer
All good to cover.Inspector Comments:
12/05/2011PassDon AllenPlumbing Water
all goodInspector Comments:
12/07/2011PassDon AllenPlumbing Underground Inspection
Nathon Wood inspected the undergroundInspector Comments:
04/02/2012PassDon AllenPlumbing Rough-in
4/2/12 - basement is all good to cover
1/10/12 - All good
Inspector Comments:
06/04/2012PassDon AllenPlumbing Final Inspection
Approved for C/OInspector Comments:
Page 2 of 2