Loading...
HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00395 - 820 Yost St - SFRPermit Inspection Summary Permit Status of (Open) as of Report Date: 04/13/2020 2:42 pm Permit Details Permit Number: 11-00395 820 Yost St - SFR 820 Yost St New Single Family Residence Permit Issued Date: 11/17/2014 Permit Inspection Statistics 20Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 85.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 11/21/2011PassTed DyeResidential Footing Inspection rebar overlaps looked good rebar suspendedInspector Comments: 11/21/2011PassTed DyeFoundation Inspection ufer installed by electrical conduitInspector Comments: 01/13/2012FailQuinton OwensResidential Framing/Structure Inspection Sheathing approved 1/4/12 (No holddowns on back left corner as required) Need Mfr approved fix for joist above laundry room. No hold downs installed as required on southwest corner. Missing full stud in Northeast corner at elect. service box. Electrician to move S.D. away from supply air in Mstr Bdrm. Inspector Comments: 01/23/2012PassQuinton OwensResidential Framing/Structure Inspection 1/4/12 - Sheathing OK to cover. No holddown straps at back left corner as required. 3/27/12 - Added finished basement. Interior partitions approved.Other framing inspected with original framing inspection. Bearing alls approved with original framing. Several locations missing insulation. Inspector Comments: 01/23/2012PassQuinton OwensResidential Insulation Inspection Framing items done. Insulation OK to cover.Inspector Comments: 02/08/2012PassQuinton OwensResidential Sheetrock/Drywall Inspection Basement drywall approved 4-3, Quinton Drywall OK to tape- 1/30/12 Inspector Comments: 04/24/2012PassQuinton OwensSidewalk Inspection 6" gravel base. OK to pour. Inspector Comments: 05/14/2012FailQuinton OwensResidential Building Final Rating on beam in garage? (Unprotected with habitable space above) Egress ladders required in bedroom window wells. Light for upper stairway not working. Inspector Comments: 05/15/2012PassQuinton OwensResidential Building Final Building Final OKInspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 11-00395 820 Yost St - SFR 820 Yost St New Single Family Residence Permit Status of (Open) as of Report Date: 04/13/2020 2:42 pm Permit Inspection Summary Electrical 01/13/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-inspected this on the rough-in inspection, therefore no separate ticket was written for the service inspection. Inspector Comments: 03/12/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in 1/13/12 - Approved for cover-unfinished basement-service inspected with the rough-in-need to move the smoke alarm box in the master bedroom away from the supply air duct at least 3 feet-will re-inspect on the final-called and mentioned to Wayne Van Orden(electrical contractor). 3/27/12 - Approved for cover in the basement. Inspector Comments: 05/14/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Master bedroom receptacles have reversed polarity, kitchen hallway and laundry receptacles not working, call for a re-inspect when ready. Inspector Comments: 05/14/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection 5/15/12 - Approved for a final and C.O.-entire house. 5/14/12 - Approved for a final and C.O. Basement only. Inspector Comments: Mechanical 01/13/2012PassQuinton OwensHVAC Rough-in Added exception for finished basement (3-27, QO): 6" combustion air vent is insufficient for 107,000 btu/hr. Vent openings into main living space will be required. Inspector Comments: 05/14/2012PassQuinton OwensHVAC Final Inspection Mech final approved.Inspector Comments: Plumbing 12/05/2011PassDon AllenPlumbing Sewer All good to cover.Inspector Comments: 12/05/2011PassDon AllenPlumbing Water all goodInspector Comments: 12/07/2011PassDon AllenPlumbing Underground Inspection Nathon Wood inspected the undergroundInspector Comments: 04/02/2012PassDon AllenPlumbing Rough-in 4/2/12 - basement is all good to cover 1/10/12 - All good Inspector Comments: 06/04/2012PassDon AllenPlumbing Final Inspection Approved for C/OInspector Comments: Page 2 of 2