Permit Status of (Expired) as of Report Date: 04/13/2020 2:23 pm
Permit Details Permit Number: 11-00371
1145 Arctic Willow Drive - SFR
1145 Arctic Willow Drive
New Single Family Residence
Permit Issued Date: 11/10/2014
Permit Inspection Statistics
20Total Inspections Completed:
18Total Inspections Passed:
Inspection Pass Rate: 90.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building
11/21/2011PassTed DyeCommercial Footing Inspection
overlaps on rebar looked good rebar lifted of the ground.Inspector Comments:
11/23/2011PassTed DyeFoundation Inspection
ufer ground on west garage wall by electrical conduitInspector Comments:
01/18/2012PassQuinton OwensSheeting
A few locations not stapled. (marked in pencil on sheathing or upstairs on stud
(sw corner))
Inspector Comments:
02/09/2012FailQuinton OwensResidential Framing/Structure Inspection
Sheathing approved for cover (contractor informed of a few locations not stapled)
OK 2/9 Full width bearing needed under beam in basement. Finish nailing truss
hangers & tie downs Holes too large in upstairs plumbing walls Braced wall panel
joint blocking needed by back garage door & front entry. (see X's)
Inspector Comments:
04/30/2012PassQuinton OwensResidential Framing/Structure Inspection
4/13/12 - OK to insulate
Need statement from engineer approving truss hangers and tie downs to not be
nailed completely. Mech inspection.
4/30/12 - *approved
Inspector Comments:
05/03/2012PassQuinton OwensResidential Insulation Inspection
Seal around front door and top of right window in south wall of mstr bedroom.
(done 5-4) No attic insulation rulers. No insulation on ext. wall of basement
laundry room.
Inspector Comments:
05/09/2012PassQuinton OwensResidential Sheetrock/Drywall Inspection
5/8" type x installed where required. Missing screws in furnace closet upstairs,
Mstr closet (ceiling and above window), Mud room NW corner, and Hall bath (by
mstr bd) next to toilet)
Inspector Comments:
08/15/2012PassQuinton OwensSidewalk Inspection
Ok to pour. 5" of baseInspector Comments:
Page 1 of 2
(Continued)
Permit Details Permit Number: 11-00371
1145 Arctic Willow Drive - SFR
1145 Arctic Willow Drive
New Single Family Residence
Permit Status of (Expired) as of Report Date: 04/13/2020 2:23 pm
Permit
Inspection
Summary
08/29/2012FailQuinton OwensResidential Building Final
Inspection Text Inspection Status Inspection Status Description Request
Date Schedule Date Contact Phone
Smoke Detector in garage may not be allowed (submit Manuf'r info). 4 risers at
garage steps requires handrail. CO detector outside upstairs bdrms, west end.
Fireplace Finished? Plastic pipes penetrating from garage to house requires
firestop system around pipe. Basement insulation unfinished (see insulation insp).
Inspector Comments:
11/19/2012PassQuinton OwensResidential Building Final
Electrical
02/08/2012PassBret StoddardResidential Electrical Service Inspection
Approved to be energized for permanent power-inspected the service on the
rough-in therefore no separate ticket was written.
Inspector Comments:
02/08/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover-basement unfinished, outside walls wired entirely-service
inspected at the same time-no separate ticket was written.
Inspector Comments:
08/29/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-unfinished basement entirely, no A/C installed.Inspector Comments:
Mechanical
05/02/2012PassQuinton OwensHVAC Rough-in
Never called in. Inspected with Insulation. No furnace upstairs yet.Inspector Comments:
08/29/2012PassQuinton OwensHVAC Final Inspection
Plumbing
12/07/2011PassDon AllenPlumbing Sewer
All good to coverInspector Comments:
12/07/2011PassDon AllenPlumbing Water
All good to coverInspector Comments:
12/07/2011PassDon AllenPlumbing Underground Inspection
All good to coverInspector Comments:
04/02/2012PassDon AllenPlumbing Rough-in
all good to coverInspector Comments:
08/31/2012PassDon AllenPlumbing Final Inspection
needs the p-traps under the master bath sinks, needs toilet seat installed on the
upstairs west bathroom
Inspector Comments: