HomeMy WebLinkAboutINSPECTION SUMMARY - 11-00371 - 1145 Arctic Willow Drive - SFRPermit Inspection Summary Permit Status of (Expired) as of Report Date: 04/13/2020 2:23 pm Permit Details Permit Number: 11-00371 1145 Arctic Willow Drive - SFR 1145 Arctic Willow Drive New Single Family Residence Permit Issued Date: 11/10/2014 Permit Inspection Statistics 20Total Inspections Completed: 18Total Inspections Passed: Inspection Pass Rate: 90.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Building 11/21/2011PassTed DyeCommercial Footing Inspection overlaps on rebar looked good rebar lifted of the ground.Inspector Comments: 11/23/2011PassTed DyeFoundation Inspection ufer ground on west garage wall by electrical conduitInspector Comments: 01/18/2012PassQuinton OwensSheeting A few locations not stapled. (marked in pencil on sheathing or upstairs on stud (sw corner)) Inspector Comments: 02/09/2012FailQuinton OwensResidential Framing/Structure Inspection Sheathing approved for cover (contractor informed of a few locations not stapled) OK 2/9 Full width bearing needed under beam in basement. Finish nailing truss hangers & tie downs Holes too large in upstairs plumbing walls Braced wall panel joint blocking needed by back garage door & front entry. (see X's) Inspector Comments: 04/30/2012PassQuinton OwensResidential Framing/Structure Inspection 4/13/12 - OK to insulate Need statement from engineer approving truss hangers and tie downs to not be nailed completely. Mech inspection. 4/30/12 - *approved Inspector Comments: 05/03/2012PassQuinton OwensResidential Insulation Inspection Seal around front door and top of right window in south wall of mstr bedroom. (done 5-4) No attic insulation rulers. No insulation on ext. wall of basement laundry room. Inspector Comments: 05/09/2012PassQuinton OwensResidential Sheetrock/Drywall Inspection 5/8" type x installed where required. Missing screws in furnace closet upstairs, Mstr closet (ceiling and above window), Mud room NW corner, and Hall bath (by mstr bd) next to toilet) Inspector Comments: 08/15/2012PassQuinton OwensSidewalk Inspection Ok to pour. 5" of baseInspector Comments: Page 1 of 2 (Continued) Permit Details Permit Number: 11-00371 1145 Arctic Willow Drive - SFR 1145 Arctic Willow Drive New Single Family Residence Permit Status of (Expired) as of Report Date: 04/13/2020 2:23 pm Permit Inspection Summary 08/29/2012FailQuinton OwensResidential Building Final Inspection Text Inspection Status Inspection Status Description Request Date Schedule Date Contact Phone Smoke Detector in garage may not be allowed (submit Manuf'r info). 4 risers at garage steps requires handrail. CO detector outside upstairs bdrms, west end. Fireplace Finished? Plastic pipes penetrating from garage to house requires firestop system around pipe. Basement insulation unfinished (see insulation insp). Inspector Comments: 11/19/2012PassQuinton OwensResidential Building Final Electrical 02/08/2012PassBret StoddardResidential Electrical Service Inspection Approved to be energized for permanent power-inspected the service on the rough-in therefore no separate ticket was written. Inspector Comments: 02/08/2012PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in Approved for cover-basement unfinished, outside walls wired entirely-service inspected at the same time-no separate ticket was written. Inspector Comments: 08/29/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection Approved for a final and C.O.-unfinished basement entirely, no A/C installed.Inspector Comments: Mechanical 05/02/2012PassQuinton OwensHVAC Rough-in Never called in. Inspected with Insulation. No furnace upstairs yet.Inspector Comments: 08/29/2012PassQuinton OwensHVAC Final Inspection Plumbing 12/07/2011PassDon AllenPlumbing Sewer All good to coverInspector Comments: 12/07/2011PassDon AllenPlumbing Water All good to coverInspector Comments: 12/07/2011PassDon AllenPlumbing Underground Inspection All good to coverInspector Comments: 04/02/2012PassDon AllenPlumbing Rough-in all good to coverInspector Comments: 08/31/2012PassDon AllenPlumbing Final Inspection needs the p-traps under the master bath sinks, needs toilet seat installed on the upstairs west bathroom Inspector Comments: Page 2 of 2