Permit Inspection History *Refer to Individual Inspection Report for more Details
Building
10/26/2011PassTed DyeResidential Footing Inspection
ufer to be run in foundationInspector Comments:
10/28/2011PassPLL ADMINFoundation Inspection
As per Jon Berry
OK
Inspector Comments:
11/04/2011PassTed DyeRadon-Ground Inspection
Perforated 6" pipe around ext. walls on inside of footing vent on north side of
house.
Inspector Comments:
11/21/2011PassTed DyeSheeting
Sheeting inspection only Looked good ok to cover out side wallsInspector Comments:
12/02/2011PassTed DyeResidential Framing/Structure Inspection
house framing completeInspector Comments:
12/12/2011PassTed DyeResidential Insulation Inspection
12/2/11 - JonB - Main floor insulation looks good Crawl space and ceiling not
done yet
12/12/11 - TedD - needs inspected: attic right side of door missing foam
insualtion at bottom. I will check when doing sheetrock inspection.
Inspector Comments:
12/12/2011PassTed DyeResidential Sheetrock/Drywall Inspection
basement finish: ****MAY NOT be used as and apartment/ 1/2" ultra light
sheetrock on ceiling of basement.
Inspector Comments:
01/12/2012FailQuinton OwensResidential Building Final
Handrail in garage and at basement walkout are too short. Outside concrete to
be done as soon as weather permits. No multifamily use allowed (missing fire &
mech. separation and C.U.P.)
Inspector Comments:
01/17/2012PassQuinton OwensResidential Building Final
Outside concrete work not done. Sidewalk completed without base insp. Steps
approved (3 risers no hand/guardrail required)
Building final OK. Temp unit concrete work is done.
Inspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 11-00359
244 Pollard Avenue - SFR (571 Cook)
571 Cook Street
New Single Family Residence
Permit Status of (Expired) as of Report Date: 04/13/2020 2:14 pm
Permit
Inspection
Summary
08/02/2012PassQuinton OwensSidewalk Inspection
Poured without inspection of base.
Steps OK (no handrail needed)
Inspector Comments:
Electrical
11/07/2011FailBret StoddardResidential Electrical Service Inspection
No service was installed.Inspector Comments:
11/14/2011PassBret StoddardResidential Electrical Service Inspection
Approved for energizing for permanent power.Inspector Comments:
11/30/2011PassBret StoddardSFR-A,R,B, MFR,MFR-A,R Electrical Rough-in
Approved for cover.Inspector Comments:
01/06/2012FailBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Need to install a K.O. seal in the bottom of the meter main, intersystem bonding
termination not installed, outdoor switch needs to be wet location rated-not
damp location rated, bath fans not installed, call for a re-inspect when ready.
Inspector Comments:
01/11/2012PassBret StoddardSFR, SFR-B, SFR-A, SFR-R, MFR, MFR-A, MFR-R Electrical Final Inspection
Approved for a final and C.O.-No A/C unit is installed-30A OCPD.Inspector Comments:
Mechanical
11/30/2011PassPLL ADMINHVAC Rough-in
As per Jon Berry
HVAC rough looks good.
Inspector Comments:
01/11/2012PassPLL ADMINHVAC Final Inspection
As per Jon Berry
HVAC final completed.
Inspector Comments:
Plumbing
11/07/2011PassDon AllenPlumbing Sewer
11/07/2011 all good to coverInspector Comments:
11/07/2011PassDon AllenPlumbing Water
11/07/2011 all good to coverInspector Comments:
11/07/2011PassDon AllenPlumbing Underground Inspection
Groundwork is all good to cover.Inspector Comments:
11/23/2011PassDon AllenPlumbing Rough-in
all good to cover and pull the testInspector Comments:
01/06/2012PassDon AllenPlumbing Final Inspection
all good for the c.oInspector Comments: