Loading...
HomeMy WebLinkAboutFIRE ALARM PLANS - 20-00128 - Madison Memorial Radiology RemodelS H E E T : D R A W N B Y : C H E C K E D B Y : J O B # : P R O J E C T # : DESCRIPTIONCADDATEMARK S Y S T E M : CHK I S S U E D A T E : 24" x 36" - Arch D Size ISSUE LOG:Revisions shown with # symbol E R I C A R A N E N S O N N I C E T L E V E L I I I # 1 3 5 9 6 3 DRAWING INDEXLEGENDS P R O J E C T D I R E C T O R Y J O H N S O N C O N T R O L S C O N T A C T S S C O P E O F W O R K A P P L I C A B L E C O D E S & S T A N D A R D S D E V I C E T A G L E G E N D A B B R E V I A T I O N S L E G E N D S Y S T E M S E Q U E N C E O F O P E R A T I O N S D E S I G N S T A T E M E N T GENERAL NOTES FIRE AL A R M S Y S T E M RADIOL O G Y R E M O D E L MADI S O N M E M O R I A L H O S P I T A L 1 : T 2 : A 2 : 1 - 1 ( E 1 : 1 ) · F A : = F A C P ( N O N - N E T W O R K ) · # : = N O D E N U M B E R · T # : = T R A N S P O N D E R N U M B E R · # : T # = N O D E : T R A N S P O N D E R N U M B E R · N # : = N A C E X T E N D E R N U M B E R · A # : # = E P S 1 N U M B E R : I D N A C 2 C H A N N E L N U M B E R · D # = D O O R H O L D E R C I R C U I T N U M B E R · F # = F I R E P H O N E C I R C U I T · H # = A U D I B L E ( H O R N ) C I R C U I T N U M B E R · M # = I D N E T L O O P N U M B E R · P # = P O W E R C I R C U I T N U M B E R · S # = S P E A K E R C I R C U I T N U M B E R · V # = V I S U A L C I R C U I T N U M B E R · Z # = Z O N E N U M B E R · ( L # ) = I D N E T I S O L A T E D L O O P N U M B E R · ( # ) = I D N A C B R A N C H N U M B E R · ( E # : # ) = E P R 3 N U M B E R : B R A N C H N U M B E R 1 . E P S = E N H A N C E D P O W E R S U P P L Y 2 . I D N A C = A D D R E S S A B L E N O T I F I C A T I O N C I R C U I T 3 . E P R = E N H A N C E D P O W E R R E P E A T E R D E V I C E N U M B E R B R A N C H / I S O L A T E D L O O P D E S I G N A T O R : C I R C U I T D E S I G N A T O R P A N E L D E S I G N A T O R T H I S P R O J E C T ' S D E S I G N I S B A S E D O N T H E E N G I N E E R E D P L A N S A N D S P E C I F I C A T I O N S P R E P A R E D B Y : 1.THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OFCONDUITS IS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGESSHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS.2.SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJORDEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO ASNOT TO IMPAIR THE CONSTRUCTION SCHEDULE.3.CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS INCIRCUITING AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTEDBY ANY AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS.4.A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FORINSTALLATION.5.THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20ABRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIREALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BEPERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT.6.UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO JOHNSONCONTROLS NO LATER THAN 7 DAYS AFTER FINAL TEST.7.THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER.8.DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICALREPRESENTATIVE.9.ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TOPROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THEFIRE ALARM INSTALLER.10.THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOFASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED.11.INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED ANDNON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITHMANUFACTURER'S INSTRUCTIONS AND APPLICABLE ELECTRICAL CODES. REFER TO 'APPLICABLE CODES & STANDARDS'FOR SPECIFIC CODE REFERENCES.12.ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES.13.FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIREALARM WIRES IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWERLIMITED WIRE.14FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPEFPLP.15.FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLEDIN VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR.16.FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WETLOCATIONS.17.FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCEAPPLICABLE ELECTRICAL CODES, WHERE APPLICABLE.18.ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS.19.ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE.20.ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT.21.120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING.22.MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS.23.EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY; HOWEVER, ANYEXISTING CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. JOHNSON CONTROLSMAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. A R C H I T E C T U R A L P L A N S D A T E D : M E C H A N I C A L P L A N S D A T E D : E L E C T R I C A L P L A N S D A T E D : S P E C I F I C A T I O N S D A T E D : A D D E N D U M D A T E D : A R C H I T E C T O R E N G I N E E R N A M E S i t e M A D I S O N M E M O R I A L H O S P I T A L 4 5 0 E . M A I N S T R E X B U R G , I D 8 3 4 4 0 - 2 0 1 3 I n s t a l l e r M A R T I N E A U E L E C T R I C 3 7 5 M A I N S T R E E T N E W D A L E , I D . 8 3 4 3 6 P H O N E : 2 0 8 - 3 9 0 - 2 1 2 6 J o h n s o n C o n t r o l s D i s t r i c t - 4 4 4 8 7 8 3 W E S T H A C K A M O R E D R I V E B O I S E , I D 8 3 7 0 9 P H O N E : 2 0 8 - 3 7 6 - 2 1 1 1 F A X : 2 0 8 - 3 7 6 - 2 1 9 2 S E R V I C E : 2 0 8 - 3 7 6 - 2 1 1 1 O C C U P A N C Y T Y P E ( S ) : S P R I N K L E R P R O T E C T I O N : I - 2 I N S T I T U T I O N A L G R O U P B U I L D I N G I S F U L L Y S P R I N K L E D M O D I F Y E X I S T I N G F I R E A L A R M S Y S T E M : R E M O V E A N D R E L O C A T E E X I S T I N G D E V I C E S A S S H O W N O N P L A N S F O R R A D I O L O G Y R E M O D E L . A L L N E W W I R I N G T O B E C L A S S A . T H E E X I S T I N G F I R E A L A R M S Y S T E M S H A L L N O T B E D I S C O N N E C T E D O R T A K E N O U T O F S E R V I C E W I T H O U T W R I T T E N P E R M I S S I O N F R O M T H E O W N E R . I T I S T H E C O N T R A C T O R ' S R E S P O N S I B I L I T Y T O C O O R D I N A T E W I T H T H E O W N E R T H E T I M I N G O F A N Y E X I S T I N G F I R E A L A R M S Y S T E M D E M O L I T I O N W O R K . J U R I S D I C T I O N S W I T H I N T H E S T A T E M A Y H A V E A M E N D M E N T S T O T H E S T A T E A D O P T E D C O D E . C H E C K W I T H T H E L O C A L J U R I S D I C T I O N A U T H O R I T Y F O R M O R E D E T A I L S . A C = A B O V E C E I L I N G A F F = A B O V E F I N I S H E D F L O O R A H J = A U T H O R I T Y H A V I N G J U R I S D I C T I O N A L M = A L A R M A N N = A N N U N C I A T O R B M S = B U I L D I N G M A N A G E M E N T S Y S T E M C = C E I L I N G M O U N T E D C D = C A N D E L A R A T I N G D E T = D E T E C T O R D G P = D A T A G A T H E R I N G P A N E L E = E X I S T I N G T O R E M A I N E O L = E N D O F L I N E E P O = E M E R G E N C Y P O W E R O F F F A A = F I R E A L A R M A N N U N C I A T O R F A C P = F I R E A L A R M C O N T R O L P A N E L F A T C = F I R E A L A R M T E R M I N A L C A B I N E T F B O = F U R N I S H E D B Y O T H E R S F C C = F I R E C O M M A N D C E N T E R F S D = F I R E S M O K E D A M P E R F T R = F I R E A L A R M T R A N S P O N D E R H = H I G H H U M I D I T Y H T = H E I G H T H V A C = H E A T I N G V E N T I L A T I O N & A I R C O N D I T I O N I N G I M S = I N F O R M A T I O N M A N A G E M E N T S Y S T E M M A X = M A X I M U M M I N = M I N I M U M N / A = N O T A P P L I C A B L E N A C = N O T I F I C A T I O N A P P L I A N C E C I R C U I T N D U = N E T W O R K D I S P L A Y U N I T N E C = N A T I O N A L E L E C T R I C C O D E N F P A = N A T I O N A L F I R E P R O T E C T I O N A S S O C I A T I O N N I C = N O T I N C O N T R A C T N P U = N E T W O R K P R O C E S S I N G U N I T N T S = N O T T O S C A L E P A P = P R E - A C T I O N P A N E L R C = E X I S T I N G T O R E M O V E A N D C O V E R R D = E X I S T I N G D E V I C E T O B E R E L O C A T E D R L = R E L O C A T E D D E V I C E R R = R E M O V E E X I S T I N G & R E P L A C E W I T H N E W S C C = S T A T U S C O M M A N D C E N T E R S L C = S I G N A L I N G L I N E C I R C U I T S M K = S M O K E S U P V = S U P E R V I S O R Y T A C = T R U E A L E R T A D D R E S S A B L E C O N T R O L L E R T R B L = T R O U B L E T S = T A M P E R S W I T C H T Y P = T Y P I C A L U O N = U N L E S S O T H E R W I S E N O T E D V C C = V O I C E C O M M A N D C E N T E R V T = V A L V E T A M P E R W = W A T T A G E W / = W I T H W / O = W I T H O U T W F = W A T E R F L O W W G = W I R E G U A R D W P = W E A T H E R P R O O F X P = E X P L O S I O N P R O O F IMPORTANT NOTICE TO USER: This information may not be sold or transferred to any third party, used on other projects or additions to theproject for which it was prepared, or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use orreuse of altered files by the user or any third party and such use will be a user's sole risk. User shall, to the fullest extent permitted by law,defend, indemnify, and hold Johnson Controls harmless from any and all claims for loss, damage or injury arising directly or indirectly from anysuch unauthorized use.LAST PRINTED:LAST SAVED BY:FILE PATH:C:\Users\janense\Johnson Controls\Project Electronics - 444-Boise\MadisonMemorial\_MMH_RadiologyRemodel_617825201\FA-001.dwg4/10/2020 9:10:41 AM JANENSE 4 4 4 : 6 1 7 8 2 5 2 0 1 E A F A 4 / 9 / 2 0 F I R E A L A R M S Y S T E M MADISON MEMORIAL HOSPITAL 450 E. MAIN ST REXBURG, ID 83440-2013 8783 WEST HACKAMORE DRIVE BOISE, ID 83709 PHONE: 208-376-2111 SERVICE: 208-376-2111 FAX: 208-376-2192 DISTRICT - 444 F A - 0 0 1 C O V E R S H E E T J O H N S O N C O N T R O L S © 2 0 2 0 MADISON MEMORIAL HOSPITAL RADIOLOGY REMODEL © Johnson Controls 2020. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited. P H O N E : S a l e s R e p r e s e n t a t i v e P E T E R P E T R O N I P E T E R . P E T R O N I @ J C I . C O M 2 0 8 - 9 1 4 - 2 0 9 9 P H O N E : P r o j e c t M a n a g e r K R I S T I N D O L A N K R I S T I N . N I C H O L E . D O L A N @ J C I . C O M 2 0 8 - 9 1 4 - 2 1 1 1 P H O N E : S c h e d u l i n g K R I S T I N D O L A N K R I S T I N . N I C H O L E . D O L A N @ J C I . C O M 2 0 8 - 9 1 4 - 2 1 1 1 P H O N E : D r a w i n g s P r e p a r e d B y E R I C A A N E N S O N E R I C A . R A E . A N E N S O N @ J C I . C O M 7 0 2 - 9 4 8 - 1 8 4 7 P H O N E : D r a w i n g s R e v i e w e d B y K E N N E T H D E I T R I C H K E N N E T H . R E I D . D E I T R I C H @ J C I . C O M 7 0 2 - 9 4 8 - 1 8 3 2 SYSTEM OUTPUTS ACTUATE COMMON ALARM SIGNAL INDICATOR ACTUATE AUDIBLE ALARM SIGNAL ACTUATE COMMON SUPERVISORY SIGNAL INDICATOR ACTUATE AUDIBLE SUPERVISORY SIGNAL ACTUATE COMMON TROUBLE SIGNAL INDICATOR ACTUATE AUDIBLE TROUBLE SIGNAL ACTUATE APPROPRIATE LOCATION INDICATOR ACTUATE ALL AUDIBLE EVACUATION SIGNALS ACTUATE ALL VISIBLE EVACUATION SIGNALS DISPLAY CHANGE OF STATUS TRANSMIT ALARM SIGNAL TO SUPERVISING STATION TRANSMIT SUPERVISORY SIGNAL TO SUPERVISING STATION TRANSMIT TROUBLE SIGNAL TO SUPERVISING STATION UNLOCK SECURITY DOORS RELEASE ELEVATOR FIRE DOORS MAIN FLOOR ELEVATOR RECALL ALTERNATE FLOOR ELEVATOR RECALL ELEVATOR HAT FLASH ELEVATOR SHUNT TRIP RELEASE MAGNETICALLY HELD SMOKE DOORS FAN SHUTDOWN DAMPER SHUTDOWN REMOTELY DISPLAY ACTIVE STATUS C T R L U N I T A N N U N C I A T I O N N O T I F I C A T I O N F I R E S A F E T Y C O N T R O L S Y S T E M I N P U T S A B C D E F G H I J K L M N O P Q R S T U V W X 1 S M O K E S E N S O R / D E T E C T O R X X X X X X X X X X X X 2 M A N U A L P U L L S T A T I O N X X X X X X X X 3 H E A T S E N S O R / D E T E C T O R X X X X X X X X 4 D U C T S E N S O R / D E T E C T O R - S U P E R V I S O R Y X X X X X X X 5 M A I N F L R . E L E V . L O B B Y S M O K E D E T E C T O R X X X X X X X X X X X X X X 6 E L E V A T O R L O B B Y S M O K E D E T E C T O R S ( E X C . M A I N F L R ) X X X X X X X X X X X X X X 7 E L E V A T O R M E C H . R O O M H E A T D E T E C T O R X X X X X X X X X 8 E L E V A T O R M E C H . R O O M S M O K E D E T E C T O R X X X X X X X X X X X X X X 9 E L E V A T O R S H A F T H E A T D E T E C T O R X X X X X X X X X 1 0 E L E V A T O R S H A F T S M O K E D E T E C T O R X X X X X X X X X X X X X X 1 1 E L E V A T O R P O W E R M O N I T O R X X X X X X 1 2 W A T E R F L O W S W I T C H X X X X X X X X X X 1 3 T A M P E R S W I T C H X X X X X X 1 4 G E N E R A T O R R U N N I N G X X X X X X 1 5 G E N E R A T O R F A U L T X X X X X X 1 6 F I R E A L A R M A C P O W E R F A I L U R E X X X X X 1 7 F I R E A L A R M S Y S T E M L O W B A T T E R Y X X X X X 1 8 O P E N C I R C U I T O R G R O U N D F A U L T X X X X X 1 9 C L A S S B N O T I F I C A T I O N C I R C U I T ( N A C ) - S H O R T X X X X X Sheet List TableSheet NumberSheet TitleGeneral Information (FA-000 Series)FA-001COVER SHEETFloorplans (FA-100 Series)FA-101DEVICE PLACEMENT-RISER-DETAILS I n t e r n a t i o n a l F i r e C o d e ( I F C ) , 2 0 1 5 E d i t i o n N a t i o n a l F i r e A l a r m C o d e ( N F P A 7 2 ) , 2 0 1 6 E d i t i o n N a t i o n a l E l e c t r i c C o d e ( N F P A 7 0 ) , 2 0 1 7 E d i t i o n I n t e r n a t i o n a l B u i l d i n g C o d e ( I B C ) , 2 0 1 5 E d i t i o n A N S I / A S M E A 1 7 . 1 2 0 1 0 E l e v a t o r C o d e w i t h S t a t e e x c e p t i o n s FIRE ALARM SYMBO L L E G E N D SYMBOLDESCRIPTION B R A N D M O D E L B A C K B O X W I R E T Y P E NOTIFICATION APPLIANCESCONVENTIONAL MULTI-CANDELA HO R N / S T R O B E , W A L L M O U N T , R E D , CLEAR LENS, FIRE W H E E L O C K M T - 2 4 M C W - F R 4 " S Q . 2 - 1 / 8 " D - F L U S H V # A C C E P T A B L E C A B L E T Y P E S FIRE ALARM WIRE L E G E N D FPLR FPLP THHN TFFN OUTDOOR ** C.I. CIRCUIT DESCRIPTIONCONSTRUCTI O N G A U G E C I R C U I T P R O P E R T I E S VVISUAL2 COND. SOLI D 1 4 A W G X X CONDUIT SIZEMAX CONDU C T O R A R E A C O N D U I T S I Z E M A X C O N D U C T O R A R E A 1/2"0.122 SQ. I N C H * 1 - 1 / 4 " 0 . 5 9 8 S Q I N C H * 3/4"0.213 SQ I N C H * 1 - 1 / 2 " 0 . 8 1 4 S Q I N C H * 1"0.346 SQ I N C H * 2 " 1 . 3 4 2 S Q I N C H * * 40% CONDUIT FILL PER N.E.C. S T P = S H I E L D E D T W I S T E D P A I R ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS A N D W I R E G A U G E C A N B E C R U C I A L T O T H E C I R C U I T D E S I G N O F T H I S S Y S T E M INSTALLATION. THE INSTALLING CONTRACTOR IS RESPO N S I B L E F O R S E L E C T I N G A N D I N S T A L L I N G C A B L E M A N U F A C T U R E R A N D M O D E L THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. R E C O M M E N D E D C A B L E M A N U F A C T U R E R S A N D M O D E L N U M B E R S A R E A V A I L A B L E UPON REQUEST. RD RDRD75V1-1 15 V1-215V1-3NICNIC NIC S A 7 5 V V V 1 - 2 V 1 - 1 1 5 V 1 - 3 1 5 E X I S T I N G S L C C I R C U I T S H E E T : D R A W N B Y : C H E C K E D B Y : J O B # : P R O J E C T # : DESCRIPTIONCADDATEMARK S Y S T E M : CHK I S S U E D A T E : 24" x 36" - Arch D Size ISSUE LOG:Revisions shown with # symbol E R I C A R A N E N S O N N I C E T L E V E L I I I # 1 3 5 9 6 3 SCALE:PARTIAL LOWER LEVEL - DEVICE PLACEMENT PLAN1/8" = 1'-0" G E N E R A L N O T E S : 1 . A L L C E I L I N G S A R E A S S U M E D T O B E 1 0 ' A . F . F . , S M O O T H C O N S T R U C T I O N U N L E S S N O T E D O T H E R W I S E . 2 . A L L N O T I F I C A T I O N A P P L I A N C E C A N D E L A I N T E N S I T Y P L U G S S H A L L R E T A I N T H E I R F A C T O R Y S E T T I N G O F " F A C P " U N L E S S O T H E R W I S E D I R E C T E D B Y T H E A U T H O R I T Y H A V I N G J U R I S D I C T I O N . 3 . D O N O T C H A N G E D E F A U L T A P P L I A N C E C O N F I G U R A T I O N S W I T C H S E T T I N G S O N A D D R E S S A B L E A / V D E V I C E S ( C F I G 1 ) . R E F E R T O D E V I C E D E T A I L S A N D I N S T A L L A T I O N I N S T R U C T I O N S F O R M O R E I N F O R M A T I O N . 4 . T H E D E V I C E A D D R E S S E S I N D I C A T E D O N T H E S E D R A W I N G S A R E A N A L P H A N U M E R I C D E S C R I P T I O N O F W H I C H C I R C U I T T H E D E V I C E I S L O C A T E D O N . D E V I C E S M A Y B E A S S I G N E D A D I F F E R E N T N U M B E R W I T H I N T H E P A N E L P R O G R A M . C O N S U L T W I T H A J O H N S O N C O N T R O L S T E C H N I C I A N B E F O R E A P P L Y I N G A P H Y S I C A L L A B E L T O A N Y D E V I C E S . 5 . T H E S C O P E O F W O R K F O R T H I S P R O J E C T I S T O R E M O V E T H E E X I S T I N G N O T I F I C A T I O N D E V I C E S A N D R E - I N S T A L L T H E M A T T H E L O C A T I O N S A S N O T E D O N P L A N . LAST PRINTED:LAST SAVED BY:FILE PATH:C:\Users\janense\Johnson Controls\Project Electronics - 444-Boise\MadisonMemorial\_MMH_RadiologyRemodel_617825201\FA-101.dwg4/10/2020 9:10:43 AM JANENSE 4 4 4 : 6 1 7 8 2 5 2 0 1 E A F A 4 / 9 / 2 0 F I R E A L A R M S Y S T E M MADISON MEMORIAL HOSPITAL 450 E. MAIN ST REXBURG, ID 83440-2013 8783 WEST HACKAMORE DRIVE BOISE, ID 83709 PHONE: 208-376-2111 SERVICE: 208-376-2111 FAX: 208-376-2192 DISTRICT - 444 F A - 1 0 1 D E V I C E P L A C E M E N T - R I S E R - D E T A I L S J O H N S O N C O N T R O L S © 2 0 2 0 MADISON MEMORIAL HOSPITAL RADIOLOGY REMODEL © Johnson Controls 2020. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited. S C A L E : N T S P A R T I A L R I S E R D I A G R A M S C A L E : N . T . S . K E Y P L A N DEVICE MOUNTING HEIGHT REFERENCEPER NFPA 72SIDE WA L L CEILING VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS1.MIN DISTANCE IN SLEEPING ROOMS IS 24" (610mm) FROM CEILING TO TOPOF LENS FOR 110CD STROBES WITHIN 16' OF THE PILLOW2.177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24"(610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER INTENSITY ISTO COMPENSATE FOR A POSSIBLE SMOKE LAYER.AUDIBLE ONLYAUDIBLE/VISUAL& VISUAL ONLYAPPLIANCESSYNCHRONIZE MORETHAN TWO APPLIANCESIN ANY FIELD OF VIEW.NOTE: REFER TO THE PROPER DEVICEINSTALLATION INSTRUCTIONSFOR BACKBOX MOUNTINGHEIGHT.NOTE : M E A S U R E M E N T S SHO W N A R E T O T H E C L O S E S T EDGE O F T H E D E T E C T O R . THE 4" REQUIREMENT FOR SMOKE DETEC T O R S H A S BEEN REMOVED FROM THE 2010 EDITION O F N F P A 7 2 CEILING MOUNTEDSMOKE/HEATDETECTORACCEPTED HEREHEAT DETECTORSNEVER HEREWALL MOUNTEDSMOKE/HEAT DETECTOR 4"(102mm)4"(102mm)3' (914mm)MINIMUM A/C SUPPLYOR RETURNDIFFUSERFINISHEDFLOORREF. 80" MIN (IBC)(2032mm MIN) REF. 96"MAX (IBC) (2440mm MAX)ABOVE FINISHED FLOOR FIREMAGNETICDOORHOLDERFIREPHONEJACK80" MIN (ADA)(2032mm MIN)80" MIN (NFPA)(2032mm MIN)TO BOTTOM OF LENS FOR CEILING HEIGHTS LESS THAN 86"(2180mm), THE VISUAL LENS MOUNTINGHEIGHT SHALL BE WITHIN 6" (150mm) OF THECEILING.96" MAX (NFPA, ADA)(2440mm MAX)ABOVE FINISHED FLOORTO TOP OF LENS48" MAX (ADA) (1219mm)48" MAX (NFPA, ADA) (1219mm MAX)42" MIN (NFPA) (1067mm MIN)MEASUREMENTS SHOWN ARETO TOP OF PULL HANDLE MANUAL PULLSTATION TO EXIT DOOR5' (MAX.)(1524mm)DOORWIDTHLESS 3"(76mm)5"(127mm)90" MIN (2286mm MIN) ABOVE FINISHEDFLOOR (OTHER MOUNTING HEIGHTSSHALL BE PERMITTED BY THE AHJPROVIDING IT MEETS THE SOUND LEVELOUTPUT REQUIRED.)NFPA 72 AUDIBLE APPLIANCE 6" MIN(152.4mm MIN) BELOW FINISHED CEILINGFIREFINISHEDWALL12" (305 m m ) MAXIMU M T O T O P O F S E N S O R NOTE: REFER TO PANEL/MODULE AND DEVICEINSTALLATION INSTRUCTIONS FOR PROPERTERMINATIONS.* USE WITH RETROFIT OR HIGH CURRENT MODULE END OF LINE RESISTOR CODESMODELREF.NUMBERΩBAND NUMBERWATTSCIRCUIT TYPEFIRE ALARM PANEL/MODULE323454081-9001733-8922.2KREDREDREDGLDN/A1/2ANNUNCIATOR (4300)4004, 4010 (TROUBLE)4081-9002733-8933.3KORGORGREDGLDN/A1 N.O. INITIATING PULL, SMOKE,HEAT, WATERFLOW, TAMPER, ETC.24 PT. I/O SWITCH SUPV.4004*, 4004R, 4005*, 4006, 4100,4120, 4100U, ZAMs4605-7401, 4100 SERIES4081-9003733-8964.7KYELVTREDGLDN/A1/2CURRENT LIMITED N.O. INIT.,NOTIFICATION (DACT)4090 IDNET IAM (EOLR)2080-90244081-9004733-8866.8KBLUGRYREDGLDN/A1/2N/O INITIATING PULL, SMOKE,HEAT, W.FLOW, TAMPER, ETC 4004, 4005, 4090-9001 IDNET IAM,2190-9173 MAPNETII 2 PT I/O4-20MA ZAM (TROUBLE)4081-9005733-9841.8KBRNGRYREDGLDN/A1/2CURRENT LIMITED N.O. INITIATING(INLINE)4090-9001 IDNET IAM4081-9006733-890560GRNBLUBRNGLDN/A1N.C. INITIATING (EOLR)4005*, 4090-9001 IDNET IAM4100, 4100U4081-9007733-8911.2KBRNREDREDGLDN/A1N.C. INITIATING (EOLR)40054081-9008733-89410KBRNBLKORGGLDN/A1/2NOTIFICATION4004, 4005, 4006, 4008, 4009, 4010,4100, 4100U4081-9009733-91220REDBLKBLKGLDN/A1TO MR-101 RELAY COIL4005 8 POINT I/O4081-9010733-9731KBRNBLKREDGLDN/A1 N.C. INIT. (ACROSS CONTACTS)4005*, 4090-9001 IDNET IAM24 PT. I/O (ACROSS CONTACTS4605-7401, 4100 SERIESCURRENT LIMITED N.O. INIT.(IN SERIES WITH CONTACT)4090-9001 IDNET IAM4081-9011733-974100BRNBLKBRNGLDN/A1/2ANNUNCIATOR (N2)4006, 4008, 40104081-9012733-98522KREDREDORGGLDN/A1/2SPEAKER CIRCUIT40034081-9013734-0864.99KYELWHTWHTBRNBRN1/24081-9014734-0922.4KREDYELREDGLDN/A1/2N.C. INITIATING (SECURITYMONITORING EOLR)4090-9001 IDNET IAM4081-9015734-0931.5KBRNGRNREDGLDN/A1/2CURRENT LIMITED N.O. INIT.(SECURITY MONITORING EOLR)4090-9001 IDNET IAM4081-9016734-149150KBRNGRNYELGLDN/A1/24081-9017734-1713.9KORGWHTREDGLDN/A14081-9018734-16810KBRNBLKORGGLDN/A170VRMS CONSTANT SUPV. NAC4100-1260378-0908.2KGRYREDREDGLDN/A1/2SECURITY MONITORING (EOLR)4100, 4100U378-0465.6KGRNBLUREDGLDN/A1/2N.O. SECURITY MON. (SERIES)4100, 4100U378-06912KBRNREDORGGLDN/A1/2N.C. SECURITY MON. (SHUNT)4100, 4100U V O L T A G E D R O P S U M M A R Y P l a n C i r c u i t D e s c r i p t i o n L o a d % D r o p V 1 R A D I O L O G Y S I G 3 0 . 2 8 5 A 1 . 5 1 % 0 . 2 8 5 A T o t a l V 1 D i s t r i b u t e d L o a d V o l t a g e D r o p A l l o w a b l e % D r o p : 1 7 . 9 % W i r e R e s . P e r F t . 0 . 0 0 3 0 7 0 @ 7 5 ° C e l s i u s R e t u r n W i r e G a u g e : 1 4 g a M i n . D e v i c e V o l t a g e : 1 6 . v d c L e n g t h S t a r t i n g V o l t a g e : 1 9 . 5 v d c % V o l t a g e D r o p 1 . 5 1 % 1 3 5 C i r c u i t C a p a c i t y 3 . A N o r m a l O p e r a t i o n C l a s s A R e t u r n D i s t a n c e D e v i c e V o l t a g e V o l t a g e A t V o l t a g e A t D e v i c e # P I D S e t t i n g ( F e e t ) C u r r e n t D r o p D e v i c e D r o p D e v i c e V 1 - 1 M T - 2 4 M C W - F R 7 5 1 0 0 0 . 1 6 5 0 . 1 7 5 1 9 . 3 3 0 . 2 9 5 1 9 . 2 1 V 1 - 2 M T - 2 4 M C W - F R 1 5 3 3 0 . 0 6 0 0 . 1 9 9 1 9 . 3 0 0 . 2 6 1 1 9 . 2 4 V 1 - 3 M T - 2 4 M C W - F R 1 5 1 8 0 . 0 6 0 0 . 2 0 6 1 9 . 2 9 0 . 2 3 6 1 9 . 2 6