HomeMy WebLinkAboutTRUSS SPECS - 20-00196 - 697 Tanglewood Dr - New SFR- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; M5 2x4 DF-L #1&Bet.;
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
L* 222 /- /- /63 /25 /18
Wind reactions based on MWFRS
L Brg Width = 264 Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 140 0
B - C 174 -232
C - D 147 -154
D - E 141 -125
E - F 219 -116
F - G 336 -141
Chords Tens. Comp.
G - H 336 -141
H - I 219 -116
I - J 129 -125
J - K 134 -142
K - L 161 -219
L - M 140 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - W 284 -212
W - V 290 -217
V - U 293 -220
U - T 296 -222
T - S 298 -223
S - R 297 -213
Chords Tens. Comp.
R - Q 297 -213
Q - P 295 -211
P - O 293 -209
O - N 289 -206
N - L 283 -202
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - W 171 -392
D - V 152 -366
E - U 154 -375
F - T 167 -445
G - R 0 -335
Gables Tens. Comp.
Q - H 167 -445
P - I 154 -375
O - J 152 -366
N - K 171 -392
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.003 H 999 240
VERT(CL): 0.004 H 999 180
HORZ(LL): 0.003 H - -
HORZ(TL): 0.004 H - -
Creep Factor: 2.0
Max TC CSI: 0.357
Max BC CSI: 0.046
Max Web CSI: 0.148
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:A1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126531 / T12 / GABL
FROM: BF DRW:
... / ... 03/19/2020
M5
22'
3'2'(TYP)
11'
11'
22'
11'
22'
22'1'4"1'4"
4"7
7'8
"
7
8'6
"
1
4
A
B
C
D
E
F
G
H
I
J
K
L
M
NOPQRSTUVW
8
12
2X4(A1T)
3X6
4X6
2X4(A1T)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; M5 2x4 DF-L #1&Bet.;
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
L* 222 /- /- /63 /25 /18
Wind reactions based on MWFRS
L Brg Width = 264 Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 140 0
B - C 174 -232
C - D 147 -154
D - E 141 -125
E - F 219 -116
F - G 336 -141
Chords Tens. Comp.
G - H 336 -141
H - I 219 -116
I - J 129 -125
J - K 134 -142
K - L 161 -219
L - M 140 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - W 284 -212
W - V 290 -217
V - U 293 -220
U - T 296 -222
T - S 298 -223
S - R 297 -213
Chords Tens. Comp.
R - Q 297 -213
Q - P 295 -211
P - O 293 -209
O - N 289 -206
N - L 283 -202
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - W 171 -392
D - V 152 -366
E - U 154 -375
F - T 167 -445
G - R 0 -335
Gables Tens. Comp.
Q - H 167 -445
P - I 154 -375
O - J 152 -366
N - K 171 -392
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.003 H 999 240
VERT(CL): 0.004 H 999 180
HORZ(LL): 0.003 H - -
HORZ(TL): 0.004 H - -
Creep Factor: 2.0
Max TC CSI: 0.357
Max BC CSI: 0.046
Max Web CSI: 0.148
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:A1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126531 / T12 / GABL
FROM: BF DRW:
... / ... 03/19/2020
M5
22'
3'2'(TYP)
11'
11'
22'
11'
22'
22'1'4"1'4"
4"7
7'8
"
7
8'6
"
1
4
A
B
C
D
E
F
G
H
I
J
K
L
M
NOPQRSTUVW
8
12
2X4(A1T)
3X6
4X6
2X4(A1T)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; W2 2x4 DF-L #1&Bet.;
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1289 /- /- /504 /88 /185
F 1158 /- /- /434 /69 /-
Wind reactions based on MWFRS
B Brg Width = 3.5 Min Req = 1.5
F Brg Width = 3.5 Min Req = 1.5
Bearings B & F Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 232 -1665
C - D 290 -1460
Chords Tens. Comp.
D - E 296 -1460
E - F 237 -1665
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - I 1285 -114
I - H 860 0
Chords Tens. Comp.
H - G 860 0
G - F 1285 -121
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - I 178 -424
I - D 556 -98
Webs Tens. Comp.
D - G 558 -110
G - E 184 -424
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.045 I 999 240
VERT(CL): 0.067 I 999 180
HORZ(LL): 0.020 G - -
HORZ(TL): 0.030 G - -
Creep Factor: 2.0
Max TC CSI: 0.332
Max BC CSI: 0.330
Max Web CSI: 0.150
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:A2
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126534 / T11 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W2
W2
22'
5'8"7
5'8"7
11'
5'3"9
16'3"9
5'3"9
22'
5'8"7
7'5"10
7'5"10
14'6"6
7'0"12
22'
7'5"101'4"
4"7
7'8
"
7
8'6
"
1
4
A
B
C
D
E
F
GHI
8
12
3X6(B1T)
2X4
3X6 3X6
4X6
3X6
2X4
3X6(B1)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; W2 2x4 DF-L #1&Bet.;
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1289 /- /- /504 /88 /185
F 1158 /- /- /434 /69 /-
Wind reactions based on MWFRS
B Brg Width = 3.5 Min Req = 1.5
F Brg Width = 3.5 Min Req = 1.5
Bearings B & F Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 232 -1665
C - D 290 -1460
Chords Tens. Comp.
D - E 296 -1460
E - F 237 -1665
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - I 1285 -114
I - H 860 0
Chords Tens. Comp.
H - G 860 0
G - F 1285 -121
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - I 178 -424
I - D 556 -98
Webs Tens. Comp.
D - G 558 -110
G - E 184 -424
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.045 I 999 240
VERT(CL): 0.067 I 999 180
HORZ(LL): 0.020 G - -
HORZ(TL): 0.030 G - -
Creep Factor: 2.0
Max TC CSI: 0.332
Max BC CSI: 0.330
Max Web CSI: 0.150
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:A2
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126534 / T11 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W2
W2
22'
5'8"7
5'8"7
11'
5'3"9
16'3"9
5'3"9
22'
5'8"7
7'5"10
7'5"10
14'6"6
7'0"12
22'
7'5"101'4"
4"7
7'8
"
7
8'6
"
1
4
A
B
C
D
E
F
GHI
8
12
3X6(B1T)
2X4
3X6 3X6
4X6
3X6
2X4
3X6(B1)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; W2 2x4 DF-L #1&Bet.;
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1290 /- /- /504 /88 /185
F 1156 /- /- /433 /69 /-
Wind reactions based on MWFRS
B Brg Width = 3.5 Min Req = 1.5
F Brg Width = - Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 232 -1666
C - D 290 -1462
Chords Tens. Comp.
D - E 297 -1465
E - F 238 -1670
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - I 1287 -114
I - H 862 0
Chords Tens. Comp.
H - G 862 0
G - F 1291 -122
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - I 178 -424
I - D 556 -98
Webs Tens. Comp.
D - G 564 -111
G - E 184 -427
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.045 I 999 240
VERT(CL): 0.067 I 999 180
HORZ(LL): 0.020 G - -
HORZ(TL): 0.030 G - -
Creep Factor: 2.0
Max TC CSI: 0.337
Max BC CSI: 0.332
Max Web CSI: 0.151
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:A3
Ply: 1
Qty: 4
Wgt: 0.0 lbs
SEQN: 126537 / T13 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W2
W2
22'
(J)Supporting Member: (2)
5'8"7
5'8"7
11'
5'3"9
16'3"9
5'3"9
22'
5'8"7
7'5"10
7'5"10
14'6"6
7'0"12
22'
7'5"101'4"
4"7
7'8
"
7
8'6
"
1
4
A
B
C
D
E
F
GHI
8
12
3X6(B1T)
2X4
3X6 3X6
4X6
3X6
2X4
3X6(B1)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; W2 2x4 DF-L #1&Bet.;
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1290 /- /- /504 /88 /185
F 1156 /- /- /433 /69 /-
Wind reactions based on MWFRS
B Brg Width = 3.5 Min Req = 1.5
F Brg Width = - Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 232 -1666
C - D 290 -1462
Chords Tens. Comp.
D - E 297 -1465
E - F 238 -1670
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - I 1287 -114
I - H 862 0
Chords Tens. Comp.
H - G 862 0
G - F 1291 -122
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - I 178 -424
I - D 556 -98
Webs Tens. Comp.
D - G 564 -111
G - E 184 -427
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.045 I 999 240
VERT(CL): 0.067 I 999 180
HORZ(LL): 0.020 G - -
HORZ(TL): 0.030 G - -
Creep Factor: 2.0
Max TC CSI: 0.337
Max BC CSI: 0.332
Max Web CSI: 0.151
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:A3
Ply: 1
Qty: 4
Wgt: 0.0 lbs
SEQN: 126537 / T13 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W2
W2
22'
(J)Supporting Member: (2)
5'8"7
5'8"7
11'
5'3"9
16'3"9
5'3"9
22'
5'8"7
7'5"10
7'5"10
14'6"6
7'0"12
22'
7'5"101'4"
4"7
7'8
"
7
8'6
"
1
4
A
B
C
D
E
F
GHI
8
12
3X6(B1T)
2X4
3X6 3X6
4X6
3X6
2X4
3X6(B1)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L 2400f-2.0E;
T2 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
B2 2x4 DF-L 2400f-2.0E;
Webs: 2x4 DF-L Stud; W4,M10 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Plating Notes
All plates are 2X4 except as noted.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Left cantilever is exposed to wind
Bearing Block(s)
Brg blocks:0.131"x3", min. nails
brg x-loc #blocks length/blk #nails/blk wall plate
1 6.500' 1 12" 4 DF-L Standard
Brg block to be same size and species as chord.
Refer to drawing CNNAILSP1014 for more information.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
AG 4104 /- /- /1464 /425 /465
S 1900 /- /- /673 /214 /-
Wind reactions based on MWFRS
AG Brg Width = 3.5 Min Req = -
S Brg Width = - Min Req = -
Bearing AG Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 141 0
B - C 1383 -559
C - D 1512 -509
D - E 1633 -447
E - F 1643 -422
F - G 1013 -211
G - H 382 -411
H - I 362 -459
I - J 372 -475
Chords Tens. Comp.
J - K 452 -414
K - L 743 -1735
L - M 669 -1848
M - N 556 -1831
N - O 567 -2043
O - P 499 -2008
P - Q 514 -2327
Q - R 425 -2386
R - S 353 -2479
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B -AI 651 -1142
AI-AH 653 -1152
AH-AG 655 -1157
AG-AF 655 -1158
AF-AE 557 -1079
AE-AD 557 -1079
AD-AC 758 -30
AC-AB 758 -30
AB-AA 758 -30
Chords Tens. Comp.
AA- Z 758 -30
Z - Y 758 -30
Y - X 758 -30
X - W 1895 -200
W - V 1895 -200
V - U 1891 -199
U - T 1899 -202
T - S 1909 -207
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
F -AF 508 -1350
AF- G 270 -2132
G -AJ 2415 -426
AK-AD 2424 -435
AD-AL 255 -1735
AM-AN 232 -1673
Webs Tens. Comp.
AO- K 232 -1665
K -AP 1520 -503
AQ-AR 1511 -503
AS- X 1442 -478
X -AT 390 -1070
AU- O 404 -1102
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.Gables Tens. Comp.
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.256 U 999 240
VERT(CL): 0.367 U 706 180
HORZ(LL): -0.151 Q - -
HORZ(TL): 0.216 Q - -
Creep Factor: 2.0
Max TC CSI: 0.944
Max BC CSI: 0.769
Max Web CSI: 0.936
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:B1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126540 / T15 / GABL
FROM: BF
Page 1 of 2
DRW:
... / ... 03/19/2020
T2
B2
W4
W4
M10
BL1
6'6"22'
(J)Supporting Member: (2)
2'3"
2'(TYP)
6'7"12
6'7"12
7'2"8
6"12
14'3"
7'0"8
21'2"1
6'11"1
28'6"
7'3"15
6'7"12
6'7"12
9'7"10
2'11"14
18'10"6
9'2"12
28'6"
9'7"101'4"
4"7
9'1
0
"
7
10
'
8
"
1
4
(a)
A
B
C
D
E F G
H
I
J
K
L
M
N
O
P
Q
R
S
TUVWXYZAAABACADAEAFAGAHAI
AJ
AK
AL
AM
ANAO AP
AQ
AR
AS
AT
AU
8
12
3X6(B1T)
8X8
6X6(R)
5X6(R)
6X10(R)
5X6 4X6(R)
4X6(B1)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L 2400f-2.0E;
T2 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
B2 2x4 DF-L 2400f-2.0E;
Webs: 2x4 DF-L Stud; W4,M10 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Plating Notes
All plates are 2X4 except as noted.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Left cantilever is exposed to wind
Bearing Block(s)
Brg blocks:0.131"x3", min. nails
brg x-loc #blocks length/blk #nails/blk wall plate
1 6.500' 1 12" 4 DF-L Standard
Brg block to be same size and species as chord.
Refer to drawing CNNAILSP1014 for more information.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
AG 4104 /- /- /1464 /425 /465
S 1900 /- /- /673 /214 /-
Wind reactions based on MWFRS
AG Brg Width = 3.5 Min Req = -
S Brg Width = - Min Req = -
Bearing AG Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 141 0
B - C 1383 -559
C - D 1512 -509
D - E 1633 -447
E - F 1643 -422
F - G 1013 -211
G - H 382 -411
H - I 362 -459
I - J 372 -475
Chords Tens. Comp.
J - K 452 -414
K - L 743 -1735
L - M 669 -1848
M - N 556 -1831
N - O 567 -2043
O - P 499 -2008
P - Q 514 -2327
Q - R 425 -2386
R - S 353 -2479
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B -AI 651 -1142
AI-AH 653 -1152
AH-AG 655 -1157
AG-AF 655 -1158
AF-AE 557 -1079
AE-AD 557 -1079
AD-AC 758 -30
AC-AB 758 -30
AB-AA 758 -30
Chords Tens. Comp.
AA- Z 758 -30
Z - Y 758 -30
Y - X 758 -30
X - W 1895 -200
W - V 1895 -200
V - U 1891 -199
U - T 1899 -202
T - S 1909 -207
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
F -AF 508 -1350
AF- G 270 -2132
G -AJ 2415 -426
AK-AD 2424 -435
AD-AL 255 -1735
AM-AN 232 -1673
Webs Tens. Comp.
AO- K 232 -1665
K -AP 1520 -503
AQ-AR 1511 -503
AS- X 1442 -478
X -AT 390 -1070
AU- O 404 -1102
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.Gables Tens. Comp.
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.256 U 999 240
VERT(CL): 0.367 U 706 180
HORZ(LL): -0.151 Q - -
HORZ(TL): 0.216 Q - -
Creep Factor: 2.0
Max TC CSI: 0.944
Max BC CSI: 0.769
Max Web CSI: 0.936
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:B1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126540 / T15 / GABL
FROM: BF
Page 1 of 2
DRW:
... / ... 03/19/2020
T2
B2
W4
W4
M10
BL1
6'6"22'
(J)Supporting Member: (2)
2'3"
2'(TYP)
6'7"12
6'7"12
7'2"8
6"12
14'3"
7'0"8
21'2"1
6'11"1
28'6"
7'3"15
6'7"12
6'7"12
9'7"10
2'11"14
18'10"6
9'2"12
28'6"
9'7"101'4"
4"7
9'1
0
"
7
10
'
8
"
1
4
(a)
A
B
C
D
E F G
H
I
J
K
L
M
N
O
P
Q
R
S
TUVWXYZAAABACADAEAFAGAHAI
AJ
AK
AL
AM
ANAO AP
AQ
AR
AS
AT
AU
8
12
3X6(B1T)
8X8
6X6(R)
5X6(R)
6X10(R)
5X6 4X6(R)
4X6(B1)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
C -AI 83 -153
D -AH 93 -169
E -AG 40 -59
AJ- H 152 -456
AE-AK 164 -473
AL-AC 135 -358
I -AM 162 -430
AN-AB 87 -187
J -AO 88 -199
K -AA 366 -100
AP- L 90 -209
Z -AQ 89 -196
AR- M 160 -437
Y -AS 132 -357
AT- W 180 -54
N -AU 213 -70
V - P 202 -55
U - Q 121 -278
T - R 91 -182
Job Number:J209456
-FALL CREEK HOMES
Truss Label:B1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126540 / T15 / GABL
FROM: BF
Page 2 of 2
DRW:
... / ... 03/19/2020
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; W4 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Left cantilever is exposed to wind
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
K 2133 /- /- /936 /103 /232
G 1111 /- /- /418 /62 /-
Wind reactions based on MWFRS
K Brg Width = 3.5 Min Req = 1.9
G Brg Width = - Min Req = -
Bearing K Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 71 0
B - C 926 -289
C - D 712 -201
Chords Tens. Comp.
D - E 396 -539
E - F 276 -1246
F - G 199 -1513
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - K 344 -621
K - J 281 -626
J - I 553 -37
Chords Tens. Comp.
I - H 553 -37
H - G 1135 -68
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - K 195 -803
K - D 262 -1565
D - J 1046 -89
Webs Tens. Comp.
J - E 198 -954
E - H 773 -144
H - F 241 -570
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.036 K 999 240
VERT(CL): 0.054 K 999 180
HORZ(LL): 0.012 H - -
HORZ(TL): 0.020 H - -
Creep Factor: 2.0
Max TC CSI: 0.794
Max BC CSI: 0.550
Max Web CSI: 0.686
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:B2
Ply: 1
Qty: 2
Wgt: 0.0 lbs
SEQN: 126543 / T17 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W4
W4
6'6"22'
(J)Supporting Member: (2)
6'7"12
6'7"12
7'2"8
6"12
14'3"
7'0"8
21'2"1
6'11"1
28'6"
7'3"15
6'7"12
6'7"12
9'7"10
2'11"14
18'10"6
9'2"12
28'6"
9'7"101'4"
4"7
9'1
0
"
7
10
'
8
"
1
4
(a)
A
B
C D
E
F
G
HIJK
8
12
2X4(A1T)
2X4
3X6
4X6
4X6 3X6
6X6(R1)
3X6
2X4
3X6(B1)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; W4 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Left cantilever is exposed to wind
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
K 2133 /- /- /936 /103 /232
G 1111 /- /- /418 /62 /-
Wind reactions based on MWFRS
K Brg Width = 3.5 Min Req = 1.9
G Brg Width = - Min Req = -
Bearing K Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 71 0
B - C 926 -289
C - D 712 -201
Chords Tens. Comp.
D - E 396 -539
E - F 276 -1246
F - G 199 -1513
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - K 344 -621
K - J 281 -626
J - I 553 -37
Chords Tens. Comp.
I - H 553 -37
H - G 1135 -68
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - K 195 -803
K - D 262 -1565
D - J 1046 -89
Webs Tens. Comp.
J - E 198 -954
E - H 773 -144
H - F 241 -570
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.036 K 999 240
VERT(CL): 0.054 K 999 180
HORZ(LL): 0.012 H - -
HORZ(TL): 0.020 H - -
Creep Factor: 2.0
Max TC CSI: 0.794
Max BC CSI: 0.550
Max Web CSI: 0.686
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:B2
Ply: 1
Qty: 2
Wgt: 0.0 lbs
SEQN: 126543 / T17 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W4
W4
6'6"22'
(J)Supporting Member: (2)
6'7"12
6'7"12
7'2"8
6"12
14'3"
7'0"8
21'2"1
6'11"1
28'6"
7'3"15
6'7"12
6'7"12
9'7"10
2'11"14
18'10"6
9'2"12
28'6"
9'7"101'4"
4"7
9'1
0
"
7
10
'
8
"
1
4
(a)
A
B
C D
E
F
G
HIJK
8
12
2X4(A1T)
2X4
3X6
4X6
4X6 3X6
6X6(R1)
3X6
2X4
3X6(B1)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1,W6 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Left end vertical not exposed to wind pressure.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
I 1151 /- /- /421 /82 /199
E 1164 /- /- /452 /58 /-
Wind reactions based on MWFRS
I Brg Width = 5.5 Min Req = 1.5
E Brg Width = - Min Req = -
Bearing I Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 109 -78
B - C 219 -845
Chords Tens. Comp.
C - D 202 -950
D - E 205 -1630
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
I - H 526 -42
H - G 1226 -72
Chords Tens. Comp.
G - F 1226 -72
F - E 1228 -72
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
A - I 56 -141
I - B 152 -1093
B - H 217 -34
Webs Tens. Comp.
C - H 370 -93
H - D 219 -732
D - F 256 0
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.034 F 999 240
VERT(CL): 0.052 F 999 180
HORZ(LL): 0.018 F - -
HORZ(TL): 0.027 F - -
Creep Factor: 2.0
Max TC CSI: 0.613
Max BC CSI: 0.393
Max Web CSI: 0.919
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:B3
Ply: 1
Qty: 2
Wgt: 0.0 lbs
SEQN: 126546 / T14 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W6
22'
(J)Supporting Member: (2)
3'10"8
3'10"8
7'9"
3'10"8
14'8"1
6'11"1
22'
7'3"15
7'9"
7'9"
14'8"1
6'11"1
22'
7'3"15
4'8
"
7
4"7
9'1
0
"
7
(a)
A
B
C
D
E
FGHI
8
12
2X4
3X6(R)
3X6
4X6(R)
4X8 3X6
3X6
2X4
3X6(B1)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1,W6 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Left end vertical not exposed to wind pressure.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
I 1151 /- /- /421 /82 /199
E 1164 /- /- /452 /58 /-
Wind reactions based on MWFRS
I Brg Width = 5.5 Min Req = 1.5
E Brg Width = - Min Req = -
Bearing I Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 109 -78
B - C 219 -845
Chords Tens. Comp.
C - D 202 -950
D - E 205 -1630
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
I - H 526 -42
H - G 1226 -72
Chords Tens. Comp.
G - F 1226 -72
F - E 1228 -72
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
A - I 56 -141
I - B 152 -1093
B - H 217 -34
Webs Tens. Comp.
C - H 370 -93
H - D 219 -732
D - F 256 0
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.034 F 999 240
VERT(CL): 0.052 F 999 180
HORZ(LL): 0.018 F - -
HORZ(TL): 0.027 F - -
Creep Factor: 2.0
Max TC CSI: 0.613
Max BC CSI: 0.393
Max Web CSI: 0.919
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:B3
Ply: 1
Qty: 2
Wgt: 0.0 lbs
SEQN: 126546 / T14 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W6
22'
(J)Supporting Member: (2)
3'10"8
3'10"8
7'9"
3'10"8
14'8"1
6'11"1
22'
7'3"15
7'9"
7'9"
14'8"1
6'11"1
22'
7'3"15
4'8
"
7
4"7
9'1
0
"
7
(a)
A
B
C
D
E
FGHI
8
12
2X4
3X6(R)
3X6
4X6(R)
4X8 3X6
3X6
2X4
3X6(B1)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x6 DF-L SS;
Webs: 2x4 DF-L #1&Bet.; W1,W6 2x4 DF-L Stud;
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 1 Row @ 4.75" o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15)
TC: From 89 plf at 0.00 to 89 plf at 22.00
BC: From 16 plf at 0.00 to 16 plf at 6.06
BC: From 8 plf at 6.06 to 8 plf at 22.00
BC: 1486 lb Conc. Load at 6.06, 8.06,10.06
BC: 293 lb Conc. Load at 12.06,14.06,16.06,18.06
20.06
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Wind loads and reactions based on MWFRS.
Left end vertical not exposed to wind pressure.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
I 4308 /- /- /- /417 /-
E 3800 /- /- /- /600 /-
Wind reactions based on MWFRS
I Brg Width = 5.5 Min Req = 2.3
E Brg Width = - Min Req = -
Bearing I Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 52 -42
B - C 197 -1937
Chords Tens. Comp.
C - D 207 -1991
D - E 420 -2946
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
I - H 1118 -116
H - G 2378 -337
Chords Tens. Comp.
G - F 2378 -337
F - E 2389 -339
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
A - I 13 -76
I - B 239 -2303
B - H 923 -84
Webs Tens. Comp.
C - H 1857 -167
H - D 220 -980
D - F 774 -185
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.075 F 999 240
VERT(CL): 0.108 F 999 180
HORZ(LL): 0.036 B - -
HORZ(TL): 0.052 B - -
Creep Factor: 2.0
Max TC CSI: 0.481
Max BC CSI: 0.890
Max Web CSI: 0.863
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:B4
Ply: 2
Qty: 1
Wgt: 0.0 lbs
SEQN: 126582 / T32 / SPEC
FROM: BF DRW:
... / ... 03/19/2020
2 Complete Trusses Required
W1
W6
22'
(J)Supporting Member: (2)
3'10"8
3'10"8
7'9"
3'10"8
14'8"1
6'11"1
22'
7'3"15
7'9"
7'9"
14'8"1
6'11"1
22'
7'3"15
4'8
"
7
4"7
9'1
0
"
7
A
B
C
D
E
FGHI
8
12
2X4
4X6(R)
5X6
4X6(R)
8X8 H0514
3X6
3X6
5X6(A9R)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x6 DF-L SS;
Webs: 2x4 DF-L #1&Bet.; W1,W6 2x4 DF-L Stud;
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 1 Row @ 4.75" o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15)
TC: From 89 plf at 0.00 to 89 plf at 22.00
BC: From 16 plf at 0.00 to 16 plf at 6.06
BC: From 8 plf at 6.06 to 8 plf at 22.00
BC: 1486 lb Conc. Load at 6.06, 8.06,10.06
BC: 293 lb Conc. Load at 12.06,14.06,16.06,18.06
20.06
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Wind loads and reactions based on MWFRS.
Left end vertical not exposed to wind pressure.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
I 4308 /- /- /- /417 /-
E 3800 /- /- /- /600 /-
Wind reactions based on MWFRS
I Brg Width = 5.5 Min Req = 2.3
E Brg Width = - Min Req = -
Bearing I Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 52 -42
B - C 197 -1937
Chords Tens. Comp.
C - D 207 -1991
D - E 420 -2946
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
I - H 1118 -116
H - G 2378 -337
Chords Tens. Comp.
G - F 2378 -337
F - E 2389 -339
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
A - I 13 -76
I - B 239 -2303
B - H 923 -84
Webs Tens. Comp.
C - H 1857 -167
H - D 220 -980
D - F 774 -185
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.075 F 999 240
VERT(CL): 0.108 F 999 180
HORZ(LL): 0.036 B - -
HORZ(TL): 0.052 B - -
Creep Factor: 2.0
Max TC CSI: 0.481
Max BC CSI: 0.890
Max Web CSI: 0.863
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:B4
Ply: 2
Qty: 1
Wgt: 0.0 lbs
SEQN: 126582 / T32 / SPEC
FROM: BF DRW:
... / ... 03/19/2020
2 Complete Trusses Required
W1
W6
22'
(J)Supporting Member: (2)
3'10"8
3'10"8
7'9"
3'10"8
14'8"1
6'11"1
22'
7'3"15
7'9"
7'9"
14'8"1
6'11"1
22'
7'3"15
4'8
"
7
4"7
9'1
0
"
7
A
B
C
D
E
FGHI
8
12
2X4
4X6(R)
5X6
4X6(R)
8X8 H0514
3X6
3X6
5X6(A9R)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; M6,M7 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
P* 220 /- /- /62 /25 /17
Wind reactions based on MWFRS
P Brg Width = 330 Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 140 0
B - C 201 -306
C - D 208 -253
D - E 170 -191
E - F 157 -148
F - G 196 -122
G - H 305 -111
H - I 422 -141
Chords Tens. Comp.
I - J 422 -141
J - K 305 -111
K - L 196 -122
L - M 157 -148
M - N 170 -191
N - O 208 -253
O - P 201 -306
P - Q 140 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B -AD 334 -246
AD-AC 338 -249
AC-AB 344 -253
AB-AA 347 -256
AA- Z 349 -257
Z - Y 351 -259
Y - X 353 -260
Chords Tens. Comp.
X - W 353 -260
W - V 351 -259
V - U 349 -257
U - T 347 -256
T - S 344 -253
S - R 338 -249
R - P 334 -246
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C -AD 101 -200
D -AC 161 -387
E -AB 150 -373
F -AA 152 -389
G - Z 154 -382
H - Y 165 -463
I - X 0 -372
Gables Tens. Comp.
W - J 165 -463
V - K 154 -382
U - L 152 -389
T - M 150 -373
S - N 161 -387
R - O 101 -200
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.003 J 999 240
VERT(CL): 0.005 J 999 180
HORZ(LL): -0.004 G - -
HORZ(TL): 0.006 G - -
Creep Factor: 2.0
Max TC CSI: 0.357
Max BC CSI: 0.081
Max Web CSI: 0.176
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:C1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126525 / T8 / GABL
FROM: BF DRW:
... / ... 03/19/2020
M6
M7
M6
27'6"
1'9"
2'(TYP)
13'9"
13'9"
27'6"
13'9"
27'6"
27'6"1'4"1'4"
4"7
9'6
"
7
10
'
4
"
1
4
(a)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
RSTUVWXYZAAABACAD
8
12
3X6(B1T)
4X6
5X6
3X6(B1T)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; M6,M7 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
P* 220 /- /- /62 /25 /17
Wind reactions based on MWFRS
P Brg Width = 330 Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 140 0
B - C 201 -306
C - D 208 -253
D - E 170 -191
E - F 157 -148
F - G 196 -122
G - H 305 -111
H - I 422 -141
Chords Tens. Comp.
I - J 422 -141
J - K 305 -111
K - L 196 -122
L - M 157 -148
M - N 170 -191
N - O 208 -253
O - P 201 -306
P - Q 140 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B -AD 334 -246
AD-AC 338 -249
AC-AB 344 -253
AB-AA 347 -256
AA- Z 349 -257
Z - Y 351 -259
Y - X 353 -260
Chords Tens. Comp.
X - W 353 -260
W - V 351 -259
V - U 349 -257
U - T 347 -256
T - S 344 -253
S - R 338 -249
R - P 334 -246
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C -AD 101 -200
D -AC 161 -387
E -AB 150 -373
F -AA 152 -389
G - Z 154 -382
H - Y 165 -463
I - X 0 -372
Gables Tens. Comp.
W - J 165 -463
V - K 154 -382
U - L 152 -389
T - M 150 -373
S - N 161 -387
R - O 101 -200
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.003 J 999 240
VERT(CL): 0.005 J 999 180
HORZ(LL): -0.004 G - -
HORZ(TL): 0.006 G - -
Creep Factor: 2.0
Max TC CSI: 0.357
Max BC CSI: 0.081
Max Web CSI: 0.176
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:C1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126525 / T8 / GABL
FROM: BF DRW:
... / ... 03/19/2020
M6
M7
M6
27'6"
1'9"
2'(TYP)
13'9"
13'9"
27'6"
13'9"
27'6"
27'6"1'4"1'4"
4"7
9'6
"
7
10
'
4
"
1
4
(a)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
RSTUVWXYZAAABACAD
8
12
3X6(B1T)
4X6
5X6
3X6(B1T)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; W2 2x4 DF-L #1&Bet.;
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1577 /- /- /612 /105 /240
F 1577 /- /- /612 /105 /-
Wind reactions based on MWFRS
B Brg Width = 3.5 Min Req = 1.7
F Brg Width = 3.5 Min Req = 1.7
Bearings B & F Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 292 -2106
C - D 365 -1847
Chords Tens. Comp.
D - E 365 -1847
E - F 292 -2106
F - G 70 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - J 1629 -107
J - I 1083 0
Chords Tens. Comp.
I - H 1083 0
H - F 1629 -111
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - J 226 -539
J - D 712 -130
Webs Tens. Comp.
D - H 712 -130
H - E 226 -539
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.070 H 999 240
VERT(CL): 0.104 H 999 180
HORZ(LL): 0.032 H - -
HORZ(TL): 0.047 H - -
Creep Factor: 2.0
Max TC CSI: 0.554
Max BC CSI: 0.497
Max Web CSI: 0.276
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:C2
Ply: 1
Qty: 6
Wgt: 0.0 lbs
SEQN: 126528 / T7 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W2
W2
27'6"
7'0"15
7'0"15
13'9"
6'8"1
20'5"1
6'8"1
27'6"
7'0"15
9'3"10
9'3"10
18'2"6
8'10"12
27'6"
9'3"101'4"1'4"
4"7
9'6
"
7
10
'
4
"
1
4
A
B
C
D
E
F
GHIJ
8
12
3X6(B1T)
2X4
3X6
4X6(R)
3X6 3X6
2X4
3X6(B1T)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; W2 2x4 DF-L #1&Bet.;
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1577 /- /- /612 /105 /240
F 1577 /- /- /612 /105 /-
Wind reactions based on MWFRS
B Brg Width = 3.5 Min Req = 1.7
F Brg Width = 3.5 Min Req = 1.7
Bearings B & F Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 292 -2106
C - D 365 -1847
Chords Tens. Comp.
D - E 365 -1847
E - F 292 -2106
F - G 70 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - J 1629 -107
J - I 1083 0
Chords Tens. Comp.
I - H 1083 0
H - F 1629 -111
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - J 226 -539
J - D 712 -130
Webs Tens. Comp.
D - H 712 -130
H - E 226 -539
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.070 H 999 240
VERT(CL): 0.104 H 999 180
HORZ(LL): 0.032 H - -
HORZ(TL): 0.047 H - -
Creep Factor: 2.0
Max TC CSI: 0.554
Max BC CSI: 0.497
Max Web CSI: 0.276
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:C2
Ply: 1
Qty: 6
Wgt: 0.0 lbs
SEQN: 126528 / T7 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W2
W2
27'6"
7'0"15
7'0"15
13'9"
6'8"1
20'5"1
6'8"1
27'6"
7'0"15
9'3"10
9'3"10
18'2"6
8'10"12
27'6"
9'3"101'4"1'4"
4"7
9'6
"
7
10
'
4
"
1
4
A
B
C
D
E
F
GHIJ
8
12
3X6(B1T)
2X4
3X6
4X6(R)
3X6 3X6
2X4
3X6(B1T)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L 2400f-2.0E;
Bot chord: 2x6 DF-L 2400f-1.8E;
Webs: 2x4 DF-L Stud; W4,W5 2x4 DF-L #1&Bet.;
Lt Wedge: 2x8 DF-L SS;Rt Wedge: 2x8 DF-L SS;
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 2 Rows @ 5.00" o.c. (Each Row)
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15)
TC: From 89 plf at -1.50 to 89 plf at 27.50
BC: From 16 plf at 0.00 to 16 plf at 7.88
BC: From 8 plf at 7.88 to 8 plf at 27.50
BC: 3800 lb Conc. Load at 7.88
BC: 1164 lb Conc. Load at 9.94,11.94
BC: 1111 lb Conc. Load at 13.94,15.94
BC: 1900 lb Conc. Load at 17.94
BC: 1156 lb Conc. Load at 19.44,21.44,23.44,25.44
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Wind loads and reactions based on MWFRS.
Bearing Block(s)
Brg blocks:0.131"x3", min. nails
brg x-loc #blocks length/blk #nails/blk wall plate
1 0.000' 1 12" 7 DF-L Standard
2 27.208' 1 16" 20 DF-L Standard
Brg block to be same size and species as chord.
Refer to drawing CNNAILSP1014 for more information.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 8154 /- /- /- /827 /-
H 9589 /- /- /- /800 /-
Wind reactions based on MWFRS
B Brg Width = 3.5 Min Req = -
H Brg Width = 3.5 Min Req = -
Bearings B & H Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 -6
B - C 685 -6765
C - D 701 -6896
D - E 444 -4866
Chords Tens. Comp.
E - F 444 -4866
F - G 606 -6905
G - H 650 -7700
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - N 5576 -561
N - M 5583 -562
M - L 5614 -566
L - K 5621 -492
Chords Tens. Comp.
K - J 5621 -492
J - I 6343 -533
I - H 6362 -534
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
N - C 45 -307
C - M 177 -20
M - D 2413 -296
D - L 282 -2201
E - L 5043 -429
Webs Tens. Comp.
L - F 181 -2210
F - J 2425 -175
J - G 43 -789
G - I 785 -24
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE, 18SS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.247 L 999 240
VERT(CL): 0.358 L 912 180
HORZ(LL): 0.087 I - -
HORZ(TL): 0.126 I - -
Creep Factor: 2.0
Max TC CSI: 0.789
Max BC CSI: 0.949
Max Web CSI: 0.831
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:C3
Ply: 2
Qty: 1
Wgt: 0.0 lbs
SEQN: 126586 / T26 / COMN
FROM: BF DRW:
... / ... 03/19/2020
2 Complete Trusses Required
W4
W5
W4
BL1 BL2
27'6"
4'1"8
4'1"8
7'11"4
3'9"12
13'9"
5'9"12
19'6"12
5'9"12
23'4"8
3'9"12
27'6"
4'1"8
4'1"8
4'1"8
7'11"4
3'9"12
13'9"
5'9"12
19'6"12
5'9"12
23'4"8
3'9"12
27'6"
4'1"81'4"
4"7
9'6
"
7
10
'
4
"
1
4
A
B
C
D
E
F
G
H
IJKLMN
8
12
7X14(B7RT)
2X4(BP)
2X4
3X6
6X10(R)
6X10
6X10
8X8(R)SS0514
6X10
6X10
3X6
3X6
7X14(B7R)
2X4(BP)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L 2400f-2.0E;
Bot chord: 2x6 DF-L 2400f-1.8E;
Webs: 2x4 DF-L Stud; W4,W5 2x4 DF-L #1&Bet.;
Lt Wedge: 2x8 DF-L SS;Rt Wedge: 2x8 DF-L SS;
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 2 Rows @ 5.00" o.c. (Each Row)
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15)
TC: From 89 plf at -1.50 to 89 plf at 27.50
BC: From 16 plf at 0.00 to 16 plf at 7.88
BC: From 8 plf at 7.88 to 8 plf at 27.50
BC: 3800 lb Conc. Load at 7.88
BC: 1164 lb Conc. Load at 9.94,11.94
BC: 1111 lb Conc. Load at 13.94,15.94
BC: 1900 lb Conc. Load at 17.94
BC: 1156 lb Conc. Load at 19.44,21.44,23.44,25.44
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Wind loads and reactions based on MWFRS.
Bearing Block(s)
Brg blocks:0.131"x3", min. nails
brg x-loc #blocks length/blk #nails/blk wall plate
1 0.000' 1 12" 7 DF-L Standard
2 27.208' 1 16" 20 DF-L Standard
Brg block to be same size and species as chord.
Refer to drawing CNNAILSP1014 for more information.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 8154 /- /- /- /827 /-
H 9589 /- /- /- /800 /-
Wind reactions based on MWFRS
B Brg Width = 3.5 Min Req = -
H Brg Width = 3.5 Min Req = -
Bearings B & H Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 35 -6
B - C 685 -6765
C - D 701 -6896
D - E 444 -4866
Chords Tens. Comp.
E - F 444 -4866
F - G 606 -6905
G - H 650 -7700
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - N 5576 -561
N - M 5583 -562
M - L 5614 -566
L - K 5621 -492
Chords Tens. Comp.
K - J 5621 -492
J - I 6343 -533
I - H 6362 -534
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
N - C 45 -307
C - M 177 -20
M - D 2413 -296
D - L 282 -2201
E - L 5043 -429
Webs Tens. Comp.
L - F 181 -2210
F - J 2425 -175
J - G 43 -789
G - I 785 -24
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE, 18SS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.247 L 999 240
VERT(CL): 0.358 L 912 180
HORZ(LL): 0.087 I - -
HORZ(TL): 0.126 I - -
Creep Factor: 2.0
Max TC CSI: 0.789
Max BC CSI: 0.949
Max Web CSI: 0.831
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:C3
Ply: 2
Qty: 1
Wgt: 0.0 lbs
SEQN: 126586 / T26 / COMN
FROM: BF DRW:
... / ... 03/19/2020
2 Complete Trusses Required
W4
W5
W4
BL1 BL2
27'6"
4'1"8
4'1"8
7'11"4
3'9"12
13'9"
5'9"12
19'6"12
5'9"12
23'4"8
3'9"12
27'6"
4'1"8
4'1"8
4'1"8
7'11"4
3'9"12
13'9"
5'9"12
19'6"12
5'9"12
23'4"8
3'9"12
27'6"
4'1"81'4"
4"7
9'6
"
7
10
'
4
"
1
4
A
B
C
D
E
F
G
H
IJKLMN
8
12
7X14(B7RT)
2X4(BP)
2X4
3X6
6X10(R)
6X10
6X10
8X8(R)SS0514
6X10
6X10
3X6
3X6
7X14(B7R)
2X4(BP)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud;
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
H* 236 /- /- /69 /54 /21
Wind reactions based on MWFRS
H Brg Width = 144 Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 140 0
B - C 38 -123
C - D 128 -86
D - E 169 -105
Chords Tens. Comp.
E - F 169 -105
F - G 142 -111
G - H 119 -148
H - I 140 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - N 213 -105
N - M 218 -109
M - L 224 -114
Chords Tens. Comp.
L - K 224 -114
K - J 218 -114
J - H 212 -113
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
E - L 4 -345
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - N 113 -230
D - M 194 -441
Gables Tens. Comp.
K - F 194 -441
J - G 113 -230
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.002 E 999 240
VERT(CL): 0.002 E 999 180
HORZ(LL): -0.002 D - -
HORZ(TL): 0.002 D - -
Creep Factor: 2.0
Max TC CSI: 0.324
Max BC CSI: 0.052
Max Web CSI: 0.113
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:D1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126559 / T6 / GABL
FROM: BF DRW:
... / ... 03/19/2020
12'
2'
(TYP)
6'
6'
12'
6'
12'
12'1'4"1'4"
4"7
4'4
"
7
5'2
"
1
4
A
B
C
D
E
F
G
H
I
JKLMN
8
12
2X4(A1T)
4X6
2X4(A1T)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud;
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
H* 236 /- /- /69 /54 /21
Wind reactions based on MWFRS
H Brg Width = 144 Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 140 0
B - C 38 -123
C - D 128 -86
D - E 169 -105
Chords Tens. Comp.
E - F 169 -105
F - G 142 -111
G - H 119 -148
H - I 140 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - N 213 -105
N - M 218 -109
M - L 224 -114
Chords Tens. Comp.
L - K 224 -114
K - J 218 -114
J - H 212 -113
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
E - L 4 -345
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - N 113 -230
D - M 194 -441
Gables Tens. Comp.
K - F 194 -441
J - G 113 -230
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.002 E 999 240
VERT(CL): 0.002 E 999 180
HORZ(LL): -0.002 D - -
HORZ(TL): 0.002 D - -
Creep Factor: 2.0
Max TC CSI: 0.324
Max BC CSI: 0.052
Max Web CSI: 0.113
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:D1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126559 / T6 / GABL
FROM: BF DRW:
... / ... 03/19/2020
12'
2'
(TYP)
6'
6'
12'
6'
12'
12'1'4"1'4"
4"7
4'4
"
7
5'2
"
1
4
A
B
C
D
E
F
G
H
I
JKLMN
8
12
2X4(A1T)
4X6
2X4(A1T)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x6 DF-L SS;
Webs: 2x4 DF-L Stud;
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 2 Rows @ 5.50" o.c. (Each Row)
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15)
TC: From 89 plf at 0.00 to 89 plf at 12.00
BC: From 8 plf at 0.00 to 8 plf at 12.00
BC: 1183 lb Conc. Load at 2.06, 4.06, 6.06, 8.06
10.06
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Wind loads and reactions based on MWFRS.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 3509 /- /- /- /226 /-
E 3572 /- /- /- /229 /-
Wind reactions based on MWFRS
A Brg Width = 5.5 Min Req = 1.9
E Brg Width = 5.5 Min Req = 1.9
Bearings A & E Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 167 -2586
B - C 121 -1863
Chords Tens. Comp.
C - D 121 -1863
D - E 167 -2598
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - H 2122 -134
H - G 2100 -133
Chords Tens. Comp.
G - F 2110 -133
F - E 2133 -134
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
H - B 779 -35
B - G 48 -747
C - G 1888 -106
Webs Tens. Comp.
G - D 49 -760
D - F 792 -35
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.043 G 999 240
VERT(CL): 0.062 G 999 180
HORZ(LL): 0.015 B - -
HORZ(TL): 0.021 B - -
Creep Factor: 2.0
Max TC CSI: 0.208
Max BC CSI: 0.411
Max Web CSI: 0.632
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:D2
Ply: 2
Qty: 1
Wgt: 0.0 lbs
SEQN: 126580 / T25 / COMN
FROM: BF DRW:
... / ... 03/19/2020
2 Complete Trusses Required
12'
3'3"15
3'3"15
6'
2'8"1
8'8"1
2'8"1
12'
3'3"15
3'3"15
3'3"15
6'
2'8"1
8'8"1
2'8"1
12'
3'3"15
4"7
4'4
"
7
A
B
C
D
E
FGH
8
12
4X6(A1)
3X6
3X6
4X6(R)
4X8
3X6
3X6
4X6(A1)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x6 DF-L SS;
Webs: 2x4 DF-L Stud;
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 2 Rows @ 5.50" o.c. (Each Row)
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15)
TC: From 89 plf at 0.00 to 89 plf at 12.00
BC: From 8 plf at 0.00 to 8 plf at 12.00
BC: 1183 lb Conc. Load at 2.06, 4.06, 6.06, 8.06
10.06
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Wind loads and reactions based on MWFRS.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 3509 /- /- /- /226 /-
E 3572 /- /- /- /229 /-
Wind reactions based on MWFRS
A Brg Width = 5.5 Min Req = 1.9
E Brg Width = 5.5 Min Req = 1.9
Bearings A & E Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 167 -2586
B - C 121 -1863
Chords Tens. Comp.
C - D 121 -1863
D - E 167 -2598
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - H 2122 -134
H - G 2100 -133
Chords Tens. Comp.
G - F 2110 -133
F - E 2133 -134
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
H - B 779 -35
B - G 48 -747
C - G 1888 -106
Webs Tens. Comp.
G - D 49 -760
D - F 792 -35
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.043 G 999 240
VERT(CL): 0.062 G 999 180
HORZ(LL): 0.015 B - -
HORZ(TL): 0.021 B - -
Creep Factor: 2.0
Max TC CSI: 0.208
Max BC CSI: 0.411
Max Web CSI: 0.632
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:D2
Ply: 2
Qty: 1
Wgt: 0.0 lbs
SEQN: 126580 / T25 / COMN
FROM: BF DRW:
... / ... 03/19/2020
2 Complete Trusses Required
12'
3'3"15
3'3"15
6'
2'8"1
8'8"1
2'8"1
12'
3'3"15
3'3"15
3'3"15
6'
2'8"1
8'8"1
2'8"1
12'
3'3"15
4"7
4'4
"
7
A
B
C
D
E
FGH
8
12
4X6(A1)
3X6
3X6
4X6(R)
4X8
3X6
3X6
4X6(A1)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud;
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
H* 231 /- /- /67 /37 /20
Wind reactions based on MWFRS
H Brg Width = 168 Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 140 0
B - C 81 -182
C - D 90 -118
D - E 207 -135
Chords Tens. Comp.
E - F 206 -135
F - G 153 -127
G - H 147 -182
H - I 140 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - N 222 -112
N - M 228 -116
M - L 233 -119
Chords Tens. Comp.
L - K 233 -119
K - J 229 -120
J - H 222 -120
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
E - L 15 -321
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - N 173 -382
D - M 178 -420
Gables Tens. Comp.
K - F 178 -420
J - G 173 -382
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.002 E 999 240
VERT(CL): 0.002 E 999 180
HORZ(LL): -0.002 D - -
HORZ(TL): 0.003 D - -
Creep Factor: 2.0
Max TC CSI: 0.324
Max BC CSI: 0.047
Max Web CSI: 0.134
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:E1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126555 / T2 / GABL
FROM: BF DRW:
... / ... 03/19/2020
14'
3'2'
(TYP)
7'
7'
14'
7'
14'
14'1'4"1'4"
4"7
5'0
"
7
5'1
0
"
1
4
A
B
C
D
E
F
G
H
I
JKLMN
8
12
2X4(A1T)
4X6
2X4(A1T)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud;
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
H* 231 /- /- /67 /37 /20
Wind reactions based on MWFRS
H Brg Width = 168 Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 140 0
B - C 81 -182
C - D 90 -118
D - E 207 -135
Chords Tens. Comp.
E - F 206 -135
F - G 153 -127
G - H 147 -182
H - I 140 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - N 222 -112
N - M 228 -116
M - L 233 -119
Chords Tens. Comp.
L - K 233 -119
K - J 229 -120
J - H 222 -120
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
E - L 15 -321
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - N 173 -382
D - M 178 -420
Gables Tens. Comp.
K - F 178 -420
J - G 173 -382
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.002 E 999 240
VERT(CL): 0.002 E 999 180
HORZ(LL): -0.002 D - -
HORZ(TL): 0.003 D - -
Creep Factor: 2.0
Max TC CSI: 0.324
Max BC CSI: 0.047
Max Web CSI: 0.134
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:E1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126555 / T2 / GABL
FROM: BF DRW:
... / ... 03/19/2020
14'
3'2'
(TYP)
7'
7'
14'
7'
14'
14'1'4"1'4"
4"7
5'0
"
7
5'1
0
"
1
4
A
B
C
D
E
F
G
H
I
JKLMN
8
12
2X4(A1T)
4X6
2X4(A1T)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x6 DF-L SS;
Webs: 2x4 DF-L Stud; W3 2x4 DF-L #1&Bet.;
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 2 Rows @ 3.50" o.c. (Each Row)
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15)
TC: From 89 plf at 0.00 to 89 plf at 4.06
TC: From 45 plf at 4.06 to 45 plf at 10.06
TC: From 89 plf at 10.06 to 89 plf at 14.00
BC: From 8 plf at 0.00 to 8 plf at 14.00
BC: 1789 lb Conc. Load at 2.06
BC: 1802 lb Conc. Load at 4.06, 6.06, 8.06,10.06
BC: 1788 lb Conc. Load at 12.06
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Wind loads and reactions based on MWFRS.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 5891 /- /- /- /317 /-
E 5986 /- /- /- /288 /-
Wind reactions based on MWFRS
A Brg Width = 5.5 Min Req = 3.1
E Brg Width = 5.5 Min Req = 3.2
Bearings A & E Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 224 -4369
B - C 148 -3039
Chords Tens. Comp.
C - D 147 -3037
D - E 213 -4384
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - H 3602 -181
H - G 3564 -179
Chords Tens. Comp.
G - F 3576 -170
F - E 3614 -171
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
H - B 1490 -69
B - G 78 -1354
C - G 3253 -148
Webs Tens. Comp.
G - D 65 -1370
D - F 1508 -55
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.080 G 999 240
VERT(CL): 0.116 G 999 180
HORZ(LL): 0.027 B - -
HORZ(TL): 0.040 B - -
Creep Factor: 2.0
Max TC CSI: 0.489
Max BC CSI: 0.716
Max Web CSI: 0.505
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:E2
Ply: 2
Qty: 1
Wgt: 0.0 lbs
SEQN: 126557 / T5 / COMN
FROM: BF DRW:
... / ... 03/19/2020
2 Complete Trusses Required
W3
14'
3'9"15
3'9"15
7'
3'2"1
10'2"1
3'2"1
14'
3'9"15
3'9"15
3'9"15
7'
3'2"1
10'2"1
3'2"1
14'
3'9"15
4"7
5'0
"
7
A
B
C
D
E
FGH
8
12
5X8(B7R)
4X8
5X6
4X6(R)
8X8
5X6
4X8
5X8(B7R)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x6 DF-L SS;
Webs: 2x4 DF-L Stud; W3 2x4 DF-L #1&Bet.;
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 2 Rows @ 3.50" o.c. (Each Row)
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15)
TC: From 89 plf at 0.00 to 89 plf at 4.06
TC: From 45 plf at 4.06 to 45 plf at 10.06
TC: From 89 plf at 10.06 to 89 plf at 14.00
BC: From 8 plf at 0.00 to 8 plf at 14.00
BC: 1789 lb Conc. Load at 2.06
BC: 1802 lb Conc. Load at 4.06, 6.06, 8.06,10.06
BC: 1788 lb Conc. Load at 12.06
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Wind loads and reactions based on MWFRS.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 5891 /- /- /- /317 /-
E 5986 /- /- /- /288 /-
Wind reactions based on MWFRS
A Brg Width = 5.5 Min Req = 3.1
E Brg Width = 5.5 Min Req = 3.2
Bearings A & E Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 224 -4369
B - C 148 -3039
Chords Tens. Comp.
C - D 147 -3037
D - E 213 -4384
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - H 3602 -181
H - G 3564 -179
Chords Tens. Comp.
G - F 3576 -170
F - E 3614 -171
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
H - B 1490 -69
B - G 78 -1354
C - G 3253 -148
Webs Tens. Comp.
G - D 65 -1370
D - F 1508 -55
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.080 G 999 240
VERT(CL): 0.116 G 999 180
HORZ(LL): 0.027 B - -
HORZ(TL): 0.040 B - -
Creep Factor: 2.0
Max TC CSI: 0.489
Max BC CSI: 0.716
Max Web CSI: 0.505
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:E2
Ply: 2
Qty: 1
Wgt: 0.0 lbs
SEQN: 126557 / T5 / COMN
FROM: BF DRW:
... / ... 03/19/2020
2 Complete Trusses Required
W3
14'
3'9"15
3'9"15
7'
3'2"1
10'2"1
3'2"1
14'
3'9"15
3'9"15
3'9"15
7'
3'2"1
10'2"1
3'2"1
14'
3'9"15
4"7
5'0
"
7
A
B
C
D
E
FGH
8
12
5X8(B7R)
4X8
5X6
4X6(R)
8X8
5X6
4X8
5X8(B7R)
-FALL CREEK HO MESMT TMPANO G AS -FALL CREEK HO MES
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud;
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
H* 239 /- /- /70 /63 /22
Wind reactions based on MWFRS
H Brg Width = 132 Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 140 0
B - C 33 -113
C - D 129 -78
D - E 155 -102
Chords Tens. Comp.
E - F 155 -102
F - G 132 -107
G - H 97 -138
H - I 140 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - N 205 -101
N - M 209 -104
M - L 215 -110
Chords Tens. Comp.
L - K 215 -110
K - J 209 -109
J - H 202 -108
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - N 81 -151
D - M 204 -439
E - L 0 -345
Gables Tens. Comp.
K - F 204 -439
J - G 81 -151
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.002 E 999 240
VERT(CL): 0.002 E 999 180
HORZ(LL): -0.002 D - -
HORZ(TL): 0.002 D - -
Creep Factor: 2.0
Max TC CSI: 0.324
Max BC CSI: 0.052
Max Web CSI: 0.049
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:F1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126551 / T4 / GABL
FROM: BF DRW:
... / ... 03/19/2020
11'
1'6"2'
(TYP)
5'6"
5'6"
11'
5'6"
11'
11'1'4"1'4"
4"7
4'
0
"
7
4'1
0
"
1
4
A
B
C
D
E
F
G
H
I
JKLMN
8
12
2X4(A1T)
4X6
2X4(A1T)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud;
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
H* 239 /- /- /70 /63 /22
Wind reactions based on MWFRS
H Brg Width = 132 Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 140 0
B - C 33 -113
C - D 129 -78
D - E 155 -102
Chords Tens. Comp.
E - F 155 -102
F - G 132 -107
G - H 97 -138
H - I 140 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - N 205 -101
N - M 209 -104
M - L 215 -110
Chords Tens. Comp.
L - K 215 -110
K - J 209 -109
J - H 202 -108
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
C - N 81 -151
D - M 204 -439
E - L 0 -345
Gables Tens. Comp.
K - F 204 -439
J - G 81 -151
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.002 E 999 240
VERT(CL): 0.002 E 999 180
HORZ(LL): -0.002 D - -
HORZ(TL): 0.002 D - -
Creep Factor: 2.0
Max TC CSI: 0.324
Max BC CSI: 0.052
Max Web CSI: 0.049
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:F1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126551 / T4 / GABL
FROM: BF DRW:
... / ... 03/19/2020
11'
1'6"2'
(TYP)
5'6"
5'6"
11'
5'6"
11'
11'1'4"1'4"
4"7
4'
0
"
7
4'1
0
"
1
4
A
B
C
D
E
F
G
H
I
JKLMN
8
12
2X4(A1T)
4X6
2X4(A1T)
-FALL CREEK HO MESMT TMPANO G AS -FALL CREEK HO MES
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x6 DF-L SS;
Webs: 2x4 DF-L Stud;
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 2 Rows @ 3.50" o.c. (Each Row)
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15)
TC: From 89 plf at 0.00 to 89 plf at 11.00
BC: From 8 plf at 0.00 to 8 plf at 11.00
BC: 1789 lb Conc. Load at 2.06
BC: 1787 lb Conc. Load at 4.06, 6.06, 8.06,10.06
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Wind loads and reactions based on MWFRS.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 4535 /- /- /- /245 /-
E 5472 /- /- /- /247 /-
Wind reactions based on MWFRS
A Brg Width = 5.5 Min Req = 2.4
E Brg Width = 5.5 Min Req = 2.9
Bearings A & E Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 173 -3360
B - C 118 -2434
Chords Tens. Comp.
C - D 118 -2436
D - E 161 -3435
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - H 2765 -140
H - G 2732 -138
Chords Tens. Comp.
G - F 2800 -128
F - E 2836 -129
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
H - B 1059 -49
B - G 59 -951
C - G 2519 -105
Webs Tens. Comp.
G - D 46 -1041
D - F 1143 -34
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.051 G 999 240
VERT(CL): 0.074 G 999 180
HORZ(LL): 0.017 B - -
HORZ(TL): 0.025 B - -
Creep Factor: 2.0
Max TC CSI: 0.347
Max BC CSI: 0.521
Max Web CSI: 0.843
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:F2
Ply: 2
Qty: 1
Wgt: 0.0 lbs
SEQN: 126553 / T28 / COMN
FROM: BF DRW:
... / ... 03/19/2020
2 Complete Trusses Required
11'
3'0"15
3'0"15
5'6"
2'5"1
7'11"1
2'5"1
11'
3'0"15
3'0"15
3'0"15
5'6"
2'5"1
7'11"1
2'5"1
11'
3'0"15
4"7
4'0
"
7
A
B
C
D
E
FGH
8
12
4X8(B3)
5X6
4X6
4X6(R)
6X10
4X6
5X6
4X8(B3)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x6 DF-L SS;
Webs: 2x4 DF-L Stud;
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 2 Rows @ 3.50" o.c. (Each Row)
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15)
TC: From 89 plf at 0.00 to 89 plf at 11.00
BC: From 8 plf at 0.00 to 8 plf at 11.00
BC: 1789 lb Conc. Load at 2.06
BC: 1787 lb Conc. Load at 4.06, 6.06, 8.06,10.06
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Wind loads and reactions based on MWFRS.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 4535 /- /- /- /245 /-
E 5472 /- /- /- /247 /-
Wind reactions based on MWFRS
A Brg Width = 5.5 Min Req = 2.4
E Brg Width = 5.5 Min Req = 2.9
Bearings A & E Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 173 -3360
B - C 118 -2434
Chords Tens. Comp.
C - D 118 -2436
D - E 161 -3435
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - H 2765 -140
H - G 2732 -138
Chords Tens. Comp.
G - F 2800 -128
F - E 2836 -129
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
H - B 1059 -49
B - G 59 -951
C - G 2519 -105
Webs Tens. Comp.
G - D 46 -1041
D - F 1143 -34
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.051 G 999 240
VERT(CL): 0.074 G 999 180
HORZ(LL): 0.017 B - -
HORZ(TL): 0.025 B - -
Creep Factor: 2.0
Max TC CSI: 0.347
Max BC CSI: 0.521
Max Web CSI: 0.843
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:F2
Ply: 2
Qty: 1
Wgt: 0.0 lbs
SEQN: 126553 / T28 / COMN
FROM: BF DRW:
... / ... 03/19/2020
2 Complete Trusses Required
11'
3'0"15
3'0"15
5'6"
2'5"1
7'11"1
2'5"1
11'
3'0"15
3'0"15
3'0"15
5'6"
2'5"1
7'11"1
2'5"1
11'
3'0"15
4"7
4'0
"
7
A
B
C
D
E
FGH
8
12
4X8(B3)
5X6
4X6
4X6(R)
6X10
4X6
5X6
4X8(B3)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; M5,M6,M7,
M8 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
S* 205 /- /- /57 /18 /14
Wind reactions based on MWFRS
S Brg Width = 408 Min Req = -
Bearing A Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 242 -363
B - C 183 -275
C - D 153 -239
D - E 132 -237
E - F 167 -230
F - G 275 -229
G - H 403 -227
H - I 357 -209
I - J 385 -91
Chords Tens. Comp.
J - K 385 -91
K - L 357 -209
L - M 403 -227
M - N 275 -229
N - O 167 -230
O - P 160 -237
P - Q 180 -243
Q - R 210 -302
R - S 270 -391
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A -AI 315 -205
AI-AH 317 -212
AH-AG 321 -214
AG-AF 323 -216
AF-AE 325 -218
AE-AD 327 -219
AD-AC 329 -220
AC-AB 328 -221
AB-AA 328 -221
Chords Tens. Comp.
AA- Z 329 -221
Z - Y 343 -243
Y - X 343 -242
X - W 342 -241
W - V 342 -239
V - U 341 -237
U - T 340 -235
T - S 338 -228
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
B -AI 209 -470
C -AH 134 -342
D -AG 155 -389
E -AF 151 -388
F -AE 151 -403
G -AD 188 -410
H -AC 4 -382
J -AB 0 -404
Gables Tens. Comp.
AA- L 16 -382
Y - M 188 -410
X - N 151 -403
W - O 151 -388
V - P 155 -389
U - Q 134 -342
T - R 209 -470
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.005 I 999 240
VERT(CL): 0.007 I 999 180
HORZ(LL): -0.007 E - -
HORZ(TL): 0.010 G - -
Creep Factor: 2.0
Max TC CSI: 0.159
Max BC CSI: 0.088
Max Web CSI: 0.135
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126489 / T18 / GABL
FROM: BF DRW:
... / ... 03/19/2020
M5
M6
M7
M8
M7
M6
M5
34'
3'2'(TYP)
15'6"
15'6"
18'6"
3'
34'
15'6"
34'
34'
4"7
10
'
8
"
7
(a)
(a)(a)
(a)
(a)
A
B
C
D
E
F
G
H I J K L
M
N
O
P
Q
R
S
TUVWXYZAAABACADAEAFAGAHAI
8
12
3X6(B1)
3X6
3X6
3X6
3X6(B1)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; M5,M6,M7,
M8 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
S* 205 /- /- /57 /18 /14
Wind reactions based on MWFRS
S Brg Width = 408 Min Req = -
Bearing A Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 242 -363
B - C 183 -275
C - D 153 -239
D - E 132 -237
E - F 167 -230
F - G 275 -229
G - H 403 -227
H - I 357 -209
I - J 385 -91
Chords Tens. Comp.
J - K 385 -91
K - L 357 -209
L - M 403 -227
M - N 275 -229
N - O 167 -230
O - P 160 -237
P - Q 180 -243
Q - R 210 -302
R - S 270 -391
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A -AI 315 -205
AI-AH 317 -212
AH-AG 321 -214
AG-AF 323 -216
AF-AE 325 -218
AE-AD 327 -219
AD-AC 329 -220
AC-AB 328 -221
AB-AA 328 -221
Chords Tens. Comp.
AA- Z 329 -221
Z - Y 343 -243
Y - X 343 -242
X - W 342 -241
W - V 342 -239
V - U 341 -237
U - T 340 -235
T - S 338 -228
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
B -AI 209 -470
C -AH 134 -342
D -AG 155 -389
E -AF 151 -388
F -AE 151 -403
G -AD 188 -410
H -AC 4 -382
J -AB 0 -404
Gables Tens. Comp.
AA- L 16 -382
Y - M 188 -410
X - N 151 -403
W - O 151 -388
V - P 155 -389
U - Q 134 -342
T - R 209 -470
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.005 I 999 240
VERT(CL): 0.007 I 999 180
HORZ(LL): -0.007 E - -
HORZ(TL): 0.010 G - -
Creep Factor: 2.0
Max TC CSI: 0.159
Max BC CSI: 0.088
Max Web CSI: 0.135
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G1
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126489 / T18 / GABL
FROM: BF DRW:
... / ... 03/19/2020
M5
M6
M7
M8
M7
M6
M5
34'
3'2'(TYP)
15'6"
15'6"
18'6"
3'
34'
15'6"
34'
34'
4"7
10
'
8
"
7
(a)
(a)(a)
(a)
(a)
A
B
C
D
E
F
G
H I J K L
M
N
O
P
Q
R
S
TUVWXYZAAABACADAEAFAGAHAI
8
12
3X6(B1)
3X6
3X6
3X6
3X6(B1)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1789 /- /- /677 /112 /230
H 1789 /- /- /677 /112 /-
Wind reactions based on MWFRS
A Brg Width = - Min Req = -
H Brg Width = - Min Req = -
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 397 -2772
B - C 423 -2511
C - D 401 -1876
D - E 375 -1447
Chords Tens. Comp.
E - F 399 -1867
F - G 423 -2511
G - H 397 -2772
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - M 2203 -255
M - L 1842 -141
L - K 1445 -19
Chords Tens. Comp.
K - J 1842 -141
J - I 1842 -141
I - H 2203 -255
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - M 163 -367
M - C 447 -57
C - L 206 -672
D - L 618 -120
D - K 136 -128
Webs Tens. Comp.
K - E 615 -117
K - F 206 -670
F - I 446 -56
I - G 163 -367
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.115 L 999 240
VERT(CL): 0.173 L 999 180
HORZ(LL): 0.055 I - -
HORZ(TL): 0.083 I - -
Creep Factor: 2.0
Max TC CSI: 0.354
Max BC CSI: 0.442
Max Web CSI: 0.200
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G2
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126492 / T16 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W1
34'
(J)Supporting Member: (2)(J)Supporting Member: (2)
5'5"4
5'5"4
10'5"10
5'0"6
15'6"
5'0"6
18'6"
3'
23'6"6
5'0"6
28'6"12
5'0"6
34'
5'5"4
7'11"7
7'11"7
15'6"
7'6"9
18'6"
3'
26'0"9
7'6"9
34'
7'11"7
4"7
10
'
8
"
7
(a)(a)
A
B
C
D E
F
G
H
IJKLM
8
12
4X6(B1)
2X4
3X6
3X6
5X6
3X6 4X8
5X6
3X6
3X6
3X6
2X4
4X6(B1)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1789 /- /- /677 /112 /230
H 1789 /- /- /677 /112 /-
Wind reactions based on MWFRS
A Brg Width = - Min Req = -
H Brg Width = - Min Req = -
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 397 -2772
B - C 423 -2511
C - D 401 -1876
D - E 375 -1447
Chords Tens. Comp.
E - F 399 -1867
F - G 423 -2511
G - H 397 -2772
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - M 2203 -255
M - L 1842 -141
L - K 1445 -19
Chords Tens. Comp.
K - J 1842 -141
J - I 1842 -141
I - H 2203 -255
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - M 163 -367
M - C 447 -57
C - L 206 -672
D - L 618 -120
D - K 136 -128
Webs Tens. Comp.
K - E 615 -117
K - F 206 -670
F - I 446 -56
I - G 163 -367
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.115 L 999 240
VERT(CL): 0.173 L 999 180
HORZ(LL): 0.055 I - -
HORZ(TL): 0.083 I - -
Creep Factor: 2.0
Max TC CSI: 0.354
Max BC CSI: 0.442
Max Web CSI: 0.200
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G2
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126492 / T16 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W1
34'
(J)Supporting Member: (2)(J)Supporting Member: (2)
5'5"4
5'5"4
10'5"10
5'0"6
15'6"
5'0"6
18'6"
3'
23'6"6
5'0"6
28'6"12
5'0"6
34'
5'5"4
7'11"7
7'11"7
15'6"
7'6"9
18'6"
3'
26'0"9
7'6"9
34'
7'11"7
4"7
10
'
8
"
7
(a)(a)
A
B
C
D E
F
G
H
IJKLM
8
12
4X6(B1)
2X4
3X6
3X6
5X6
3X6 4X8
5X6
3X6
3X6
3X6
2X4
4X6(B1)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1,W2,W3,W4,W5,W6,
W15 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Plating Notes
All plates are 3X6 except as noted.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Left end vertical not exposed to wind pressure.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
S 1802 /- /- /627 /79 /224
K 1787 /- /- /683 /63 /-
Wind reactions based on MWFRS
S Brg Width = - Min Req = -
K Brg Width = - Min Req = -
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 125 -1784
B - C 248 -3388
C - D 390 -4412
D - E 276 -2402
E - F 327 -1912
Chords Tens. Comp.
F - G 321 -1743
G - H 279 -1446
H - I 284 -1865
I - J 312 -2508
J - K 285 -2769
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
S - R 242 -289
R - Q 2080 -69
Q - P 2433 -106
P - O 2313 0
Chords Tens. Comp.
O - N 1530 0
N - M 1433 0
M - L 1839 -47
L - K 2201 -163
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
A - S 141 -1696
A - R 2482 -175
R - B 158 -1697
B - Q 1968 -143
Q - C 278 -2595
Q - D 1688 -109
D - P 181 -767
E - P 1922 -39
E - O 156 -1981
Webs Tens. Comp.
O - F 716 -170
F - N 189 -746
G - N 727 -191
G - M 152 -113
M - H 589 -99
M - I 209 -668
I - L 446 -60
L - J 165 -368
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.216 P 999 240
VERT(CL): 0.326 P 999 180
HORZ(LL): 0.131 L - -
HORZ(TL): 0.197 L - -
Creep Factor: 2.0
Max TC CSI: 0.595
Max BC CSI: 0.510
Max Web CSI: 0.830
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G3
Ply: 1
Qty: 4
Wgt: 0.0 lbs
SEQN: 126494 / T10 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W2W3 W4 W3
W5
W6 W15
34'
(J)Supporting Member: (2)(J)Supporting Member: (2)
1'11"8
1'11"8
3'10"8
1'11"
8'2"8
4'4"
12'6"8
4'4"
14'0"8
1'6"
15'6"
1'5"8
18'6"
3'
23'6"6
5'0"6
28'6"12
5'0"6
34'
5'5"4
5"8
5"8
1'11"8
1'6"
3'10"8
1'11"
12'6"8
8'8"
14'0"8
1'6"
15'6"
1'5"8
18'6"
3'
26'0"9
7'6"9
34'
7'11"7
2'1
1
"
7
4"71'
10
'
8
"
7
(a)
(a)
(a)
A B C
D
E
F
G H
I
J
K
LMNO
PQR
S
8
12
8
12
4X8
4X6 5X8(SRS)(R)
5X6
6X10
6X6(SRS)
4X6
5X8
6X10(SRS)
6X6
5X6
4X8
5X6
2X4
4X6(B1)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1,W2,W3,W4,W5,W6,
W15 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Plating Notes
All plates are 3X6 except as noted.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Left end vertical not exposed to wind pressure.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
S 1802 /- /- /627 /79 /224
K 1787 /- /- /683 /63 /-
Wind reactions based on MWFRS
S Brg Width = - Min Req = -
K Brg Width = - Min Req = -
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 125 -1784
B - C 248 -3388
C - D 390 -4412
D - E 276 -2402
E - F 327 -1912
Chords Tens. Comp.
F - G 321 -1743
G - H 279 -1446
H - I 284 -1865
I - J 312 -2508
J - K 285 -2769
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
S - R 242 -289
R - Q 2080 -69
Q - P 2433 -106
P - O 2313 0
Chords Tens. Comp.
O - N 1530 0
N - M 1433 0
M - L 1839 -47
L - K 2201 -163
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
A - S 141 -1696
A - R 2482 -175
R - B 158 -1697
B - Q 1968 -143
Q - C 278 -2595
Q - D 1688 -109
D - P 181 -767
E - P 1922 -39
E - O 156 -1981
Webs Tens. Comp.
O - F 716 -170
F - N 189 -746
G - N 727 -191
G - M 152 -113
M - H 589 -99
M - I 209 -668
I - L 446 -60
L - J 165 -368
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.216 P 999 240
VERT(CL): 0.326 P 999 180
HORZ(LL): 0.131 L - -
HORZ(TL): 0.197 L - -
Creep Factor: 2.0
Max TC CSI: 0.595
Max BC CSI: 0.510
Max Web CSI: 0.830
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G3
Ply: 1
Qty: 4
Wgt: 0.0 lbs
SEQN: 126494 / T10 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W2W3 W4 W3
W5
W6 W15
34'
(J)Supporting Member: (2)(J)Supporting Member: (2)
1'11"8
1'11"8
3'10"8
1'11"
8'2"8
4'4"
12'6"8
4'4"
14'0"8
1'6"
15'6"
1'5"8
18'6"
3'
23'6"6
5'0"6
28'6"12
5'0"6
34'
5'5"4
5"8
5"8
1'11"8
1'6"
3'10"8
1'11"
12'6"8
8'8"
14'0"8
1'6"
15'6"
1'5"8
18'6"
3'
26'0"9
7'6"9
34'
7'11"7
2'1
1
"
7
4"71'
10
'
8
"
7
(a)
(a)
(a)
A B C
D
E
F
G H
I
J
K
LMNO
PQR
S
8
12
8
12
4X8
4X6 5X8(SRS)(R)
5X6
6X10
6X6(SRS)
4X6
5X8
6X10(SRS)
6X6
5X6
4X8
5X6
2X4
4X6(B1)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1788 /- /- /680 /67 /257
I 1919 /- /- /751 /86 /-
Wind reactions based on MWFRS
A Brg Width = - Min Req = -
I Brg Width = 5.5 Min Req = 2.0
Bearing I Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 292 -2770
B - C 318 -2509
C - D 294 -1874
D - E 284 -1446
E - F 291 -1866
Chords Tens. Comp.
F - G 310 -2408
G - H 290 -2502
H - I 283 -2764
I - J 70 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - O 2202 -134
O - N 1841 -18
N - M 1443 0
Chords Tens. Comp.
M - L 1838 -16
L - K 1838 -16
K - I 2194 -124
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - O 165 -367
O - C 447 -60
C - N 210 -673
D - N 617 -122
D - M 134 -127
Webs Tens. Comp.
M - E 614 -119
M - F 205 -667
F - K 438 -49
K - H 157 -363
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.116 N 999 240
VERT(CL): 0.174 N 999 180
HORZ(LL): 0.057 K - -
HORZ(TL): 0.085 K - -
Creep Factor: 2.0
Max TC CSI: 0.442
Max BC CSI: 0.473
Max Web CSI: 0.200
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G4
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126497 / T1 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W1
34'
(J)Supporting Member: (2)
5'5"4
5'5"4
10'5"10
5'0"6
15'6"
5'0"6
18'6"
3'
23'6"6
5'0"6
28'6"12
5'0"6
34'
5'5"4
7'11"7
7'11"7
15'6"
7'6"9
18'6"
3'
26'0"9
7'6"9
34'
7'11"7 1'4"
4"7
10
'
8
"
7
11
'
6
"
1
4
(a)(a)
A
B
C
D E
F
G
H
I
JKLMNO
8
12
4X6(B1)
2X4
3X6
3X6
5X6
3X6 4X8
5X6
3X6
3X6
3X6
3X6
2X4
5X6(B9RT)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1788 /- /- /680 /67 /257
I 1919 /- /- /751 /86 /-
Wind reactions based on MWFRS
A Brg Width = - Min Req = -
I Brg Width = 5.5 Min Req = 2.0
Bearing I Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 292 -2770
B - C 318 -2509
C - D 294 -1874
D - E 284 -1446
E - F 291 -1866
Chords Tens. Comp.
F - G 310 -2408
G - H 290 -2502
H - I 283 -2764
I - J 70 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - O 2202 -134
O - N 1841 -18
N - M 1443 0
Chords Tens. Comp.
M - L 1838 -16
L - K 1838 -16
K - I 2194 -124
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - O 165 -367
O - C 447 -60
C - N 210 -673
D - N 617 -122
D - M 134 -127
Webs Tens. Comp.
M - E 614 -119
M - F 205 -667
F - K 438 -49
K - H 157 -363
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.116 N 999 240
VERT(CL): 0.174 N 999 180
HORZ(LL): 0.057 K - -
HORZ(TL): 0.085 K - -
Creep Factor: 2.0
Max TC CSI: 0.442
Max BC CSI: 0.473
Max Web CSI: 0.200
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G4
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126497 / T1 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W1
34'
(J)Supporting Member: (2)
5'5"4
5'5"4
10'5"10
5'0"6
15'6"
5'0"6
18'6"
3'
23'6"6
5'0"6
28'6"12
5'0"6
34'
5'5"4
7'11"7
7'11"7
15'6"
7'6"9
18'6"
3'
26'0"9
7'6"9
34'
7'11"7 1'4"
4"7
10
'
8
"
7
11
'
6
"
1
4
(a)(a)
A
B
C
D E
F
G
H
I
JKLMNO
8
12
4X6(B1)
2X4
3X6
3X6
5X6
3X6 4X8
5X6
3X6
3X6
3X6
3X6
2X4
5X6(B9RT)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1789 /- /- /677 /112 /257
I 1918 /- /- /747 /130 /-
Wind reactions based on MWFRS
A Brg Width = 5.5 Min Req = 1.6
I Brg Width = 5.5 Min Req = 2.0
Bearings A & I Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 394 -2762
B - C 420 -2500
C - D 399 -1872
D - E 372 -1444
E - F 396 -1864
Chords Tens. Comp.
F - G 412 -2406
G - H 392 -2500
H - I 386 -2762
I - J 70 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - O 2192 -218
O - N 1837 -104
N - M 1441 0
Chords Tens. Comp.
M - L 1837 -102
L - K 1837 -102
K - I 2193 -208
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - O 163 -362
O - C 439 -57
C - N 206 -669
D - N 616 -119
D - M 134 -127
Webs Tens. Comp.
M - E 613 -116
M - F 202 -667
F - K 438 -47
K - H 156 -363
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.116 N 999 240
VERT(CL): 0.174 N 999 180
HORZ(LL): 0.057 K - -
HORZ(TL): 0.085 K - -
Creep Factor: 2.0
Max TC CSI: 0.442
Max BC CSI: 0.473
Max Web CSI: 0.200
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G5
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126500 / T3 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W1
34'
5'5"4
5'5"4
10'5"10
5'0"6
15'6"
5'0"6
18'6"
3'
23'6"6
5'0"6
28'6"12
5'0"6
34'
5'5"4
7'11"7
7'11"7
15'6"
7'6"9
18'6"
3'
26'0"9
7'6"9
34'
7'11"7 1'4"
4"7
10
'
8
"
7
11
'
6
"
1
4
(a)(a)
A
B
C
D E
F
G
H
I
JKLMNO
8
12
4X6(B1)
2X4
3X6
3X6
5X6
3X6 4X8
5X6
3X6
3X6
3X6
3X6
2X4
5X6(B9RT)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1789 /- /- /677 /112 /257
I 1918 /- /- /747 /130 /-
Wind reactions based on MWFRS
A Brg Width = 5.5 Min Req = 1.6
I Brg Width = 5.5 Min Req = 2.0
Bearings A & I Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 394 -2762
B - C 420 -2500
C - D 399 -1872
D - E 372 -1444
E - F 396 -1864
Chords Tens. Comp.
F - G 412 -2406
G - H 392 -2500
H - I 386 -2762
I - J 70 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - O 2192 -218
O - N 1837 -104
N - M 1441 0
Chords Tens. Comp.
M - L 1837 -102
L - K 1837 -102
K - I 2193 -208
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
B - O 163 -362
O - C 439 -57
C - N 206 -669
D - N 616 -119
D - M 134 -127
Webs Tens. Comp.
M - E 613 -116
M - F 202 -667
F - K 438 -47
K - H 156 -363
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.116 N 999 240
VERT(CL): 0.174 N 999 180
HORZ(LL): 0.057 K - -
HORZ(TL): 0.085 K - -
Creep Factor: 2.0
Max TC CSI: 0.442
Max BC CSI: 0.473
Max Web CSI: 0.200
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G5
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126500 / T3 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W1
34'
5'5"4
5'5"4
10'5"10
5'0"6
15'6"
5'0"6
18'6"
3'
23'6"6
5'0"6
28'6"12
5'0"6
34'
5'5"4
7'11"7
7'11"7
15'6"
7'6"9
18'6"
3'
26'0"9
7'6"9
34'
7'11"7 1'4"
4"7
10
'
8
"
7
11
'
6
"
1
4
(a)(a)
A
B
C
D E
F
G
H
I
JKLMNO
8
12
4X6(B1)
2X4
3X6
3X6
5X6
3X6 4X8
5X6
3X6
3X6
3X6
3X6
2X4
5X6(B9RT)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1918 /- /- /747 /130 /272
K 1918 /- /- /747 /130 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req = 2.0
K Brg Width = 5.5 Min Req = 2.0
Bearings B & K Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 382 -2762
C - D 387 -2501
D - E 409 -2424
E - F 395 -1872
F - G 369 -1444
Chords Tens. Comp.
G - H 392 -1864
H - I 409 -2406
I - J 389 -2500
J - K 382 -2762
K - L 70 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - Q 2192 -199
Q - P 1837 -97
P - O 1441 0
Chords Tens. Comp.
O - N 1837 -99
N - M 1837 -99
M - K 2193 -205
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - Q 156 -362
Q - E 439 -48
E - P 203 -669
F - P 616 -117
F - O 134 -126
Webs Tens. Comp.
O - G 613 -114
O - H 202 -667
H - M 439 -47
M - J 156 -363
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.118 P 999 240
VERT(CL): 0.175 P 999 180
HORZ(LL): 0.057 M - -
HORZ(TL): 0.085 M - -
Creep Factor: 2.0
Max TC CSI: 0.443
Max BC CSI: 0.473
Max Web CSI: 0.198
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G6
Ply: 1
Qty: 3
Wgt: 0.0 lbs
SEQN: 126503 / T37 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W1
34'
5'5"4
5'5"4
10'5"10
5'0"6
15'6"
5'0"6
18'6"
3'
23'6"6
5'0"6
28'6"12
5'0"6
34'
5'5"4
7'11"7
7'11"7
15'6"
7'6"9
18'6"
3'
26'0"9
7'6"9
34'
7'11"71'4"1'4"
4"7
10
'
8
"
7
11
'
6
"
1
4
(a)(a)
A
B
C
D
E
F G
H
I
J
K
LMNOPQ
8
12
5X6(B9RT)
2X4
3X6
3X6
3X6
5X6
3X6 4X8
5X6
3X6
3X6
3X6
3X6
2X4
5X6(B9RT)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1918 /- /- /747 /130 /272
K 1918 /- /- /747 /130 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req = 2.0
K Brg Width = 5.5 Min Req = 2.0
Bearings B & K Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 382 -2762
C - D 387 -2501
D - E 409 -2424
E - F 395 -1872
F - G 369 -1444
Chords Tens. Comp.
G - H 392 -1864
H - I 409 -2406
I - J 389 -2500
J - K 382 -2762
K - L 70 0
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - Q 2192 -199
Q - P 1837 -97
P - O 1441 0
Chords Tens. Comp.
O - N 1837 -99
N - M 1837 -99
M - K 2193 -205
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - Q 156 -362
Q - E 439 -48
E - P 203 -669
F - P 616 -117
F - O 134 -126
Webs Tens. Comp.
O - G 613 -114
O - H 202 -667
H - M 439 -47
M - J 156 -363
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.118 P 999 240
VERT(CL): 0.175 P 999 180
HORZ(LL): 0.057 M - -
HORZ(TL): 0.085 M - -
Creep Factor: 2.0
Max TC CSI: 0.443
Max BC CSI: 0.473
Max Web CSI: 0.198
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G6
Ply: 1
Qty: 3
Wgt: 0.0 lbs
SEQN: 126503 / T37 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W1
34'
5'5"4
5'5"4
10'5"10
5'0"6
15'6"
5'0"6
18'6"
3'
23'6"6
5'0"6
28'6"12
5'0"6
34'
5'5"4
7'11"7
7'11"7
15'6"
7'6"9
18'6"
3'
26'0"9
7'6"9
34'
7'11"71'4"1'4"
4"7
10
'
8
"
7
11
'
6
"
1
4
(a)(a)
A
B
C
D
E
F G
H
I
J
K
LMNOPQ
8
12
5X6(B9RT)
2X4
3X6
3X6
3X6
5X6
3X6 4X8
5X6
3X6
3X6
3X6
3X6
2X4
5X6(B9RT)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1918 /- /- /747 /130 /257
J 1789 /- /- /677 /112 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req = 2.0
J Brg Width = 5.5 Min Req = 1.6
Bearings B & J Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 385 -2762
C - D 390 -2501
D - E 412 -2424
E - F 398 -1872
Chords Tens. Comp.
F - G 373 -1444
G - H 396 -1863
H - I 420 -2500
I - J 393 -2762
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - O 2192 -242
O - N 1837 -136
N - M 1441 -17
Chords Tens. Comp.
M - L 1837 -139
L - K 1837 -139
K - J 2192 -252
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - O 156 -362
O - E 439 -47
E - N 202 -669
F - N 616 -118
F - M 136 -126
Webs Tens. Comp.
M - G 613 -115
M - H 205 -667
H - K 438 -55
K - I 163 -363
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.117 N 999 240
VERT(CL): 0.174 N 999 180
HORZ(LL): 0.056 K - -
HORZ(TL): 0.083 K - -
Creep Factor: 2.0
Max TC CSI: 0.443
Max BC CSI: 0.472
Max Web CSI: 0.198
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G7
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126506 / T24 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W1
34'
5'5"4
5'5"4
10'5"10
5'0"6
15'6"
5'0"6
18'6"
3'
23'6"6
5'0"6
28'6"12
5'0"6
34'
5'5"4
7'11"7
7'11"7
15'6"
7'6"9
18'6"
3'
26'0"9
7'6"9
34'
7'11"71'4"
4"7
10
'
8
"
7
11
'
6
"
1
4
(a)(a)
A
B
C
D
E
F G
H
I
J
KLMNO
8
12
5X6(B9RT)
2X4
3X6
3X6
3X6
5X6
3X6 4X8
5X6
3X6
3X6
3X6
2X4
4X6(B1)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1918 /- /- /747 /130 /257
J 1789 /- /- /677 /112 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req = 2.0
J Brg Width = 5.5 Min Req = 1.6
Bearings B & J Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 385 -2762
C - D 390 -2501
D - E 412 -2424
E - F 398 -1872
Chords Tens. Comp.
F - G 373 -1444
G - H 396 -1863
H - I 420 -2500
I - J 393 -2762
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - O 2192 -242
O - N 1837 -136
N - M 1441 -17
Chords Tens. Comp.
M - L 1837 -139
L - K 1837 -139
K - J 2192 -252
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
C - O 156 -362
O - E 439 -47
E - N 202 -669
F - N 616 -118
F - M 136 -126
Webs Tens. Comp.
M - G 613 -115
M - H 205 -667
H - K 438 -55
K - I 163 -363
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.117 N 999 240
VERT(CL): 0.174 N 999 180
HORZ(LL): 0.056 K - -
HORZ(TL): 0.083 K - -
Creep Factor: 2.0
Max TC CSI: 0.443
Max BC CSI: 0.472
Max Web CSI: 0.198
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G7
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126506 / T24 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W1
34'
5'5"4
5'5"4
10'5"10
5'0"6
15'6"
5'0"6
18'6"
3'
23'6"6
5'0"6
28'6"12
5'0"6
34'
5'5"4
7'11"7
7'11"7
15'6"
7'6"9
18'6"
3'
26'0"9
7'6"9
34'
7'11"71'4"
4"7
10
'
8
"
7
11
'
6
"
1
4
(a)(a)
A
B
C
D
E
F G
H
I
J
KLMNO
8
12
5X6(B9RT)
2X4
3X6
3X6
3X6
5X6
3X6 4X8
5X6
3X6
3X6
3X6
2X4
4X6(B1)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
T1 2x4 DF-L 2400f-2.0E;
Bot chord: 2x4 DF-L #1&Bet.;
B1 2x4 DF-L 2400f-2.0E;
Webs: 2x4 DF-L Stud; W5,W6,W7,W8,
W9 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1931 /- /- /752 /127 /257
J 1795 /- /- /683 /108 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req = 1.8
J Brg Width = 5.5 Min Req = 1.6
Bearings B & J Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 569 -4878
C - D 475 -4268
D - E 501 -4212
E - F 405 -2288
Chords Tens. Comp.
F - G 368 -1607
G - H 418 -2015
H - I 384 -2190
I - J 374 -2752
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - P 4107 -415
P - O 4148 -421
O - N 3606 -227
N - M 1893 -19
Chords Tens. Comp.
M - L 1791 -94
L - K 2166 -223
K - J 2168 -223
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
P - C 134 -54
C - O 179 -461
O - E 2588 -168
E - N 305 -2545
N - F 1488 -131
F - M 88 -634
Webs Tens. Comp.
M - G 852 -172
M - H 179 -247
L - H 85 -140
L - I 175 -588
I - K 232 0
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.355 O 999 240
VERT(CL): 0.532 O 760 180
HORZ(LL): 0.248 K - -
HORZ(TL): 0.372 K - -
Creep Factor: 2.0
Max TC CSI: 0.746
Max BC CSI: 0.849
Max Web CSI: 0.866
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G8
Ply: 1
Qty: 2
Wgt: 0.0 lbs
SEQN: 126509 / T34 / COMN
FROM: BF DRW:
... / ... 03/19/2020
T1
B1
W5
W6
W7
W8
W9
34'
5'8"5
5'8"5
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
27'6"9
6'0"9
34'
6'5"7
5"8
5"8
5'8"5
5'2"13
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
27'6"9
6'0"9
34'
6'5"71'4"
4"7
3'6
"
1
10
'
8
"
7
11
'
6
"
1
4
(a)
(a)
(a)
A
B
C D
E
F G
H
I
J
KL
M
N
O
P
8
12
4
12
4X8(F2T)
2X4
3X6
3X6
8X8
6X10
5X6
5X6
4X8
5X6
5X8
3X6
3X6
2X4
4X6(B1)
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
T1 2x4 DF-L 2400f-2.0E;
Bot chord: 2x4 DF-L #1&Bet.;
B1 2x4 DF-L 2400f-2.0E;
Webs: 2x4 DF-L Stud; W5,W6,W7,W8,
W9 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1931 /- /- /752 /127 /257
J 1795 /- /- /683 /108 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req = 1.8
J Brg Width = 5.5 Min Req = 1.6
Bearings B & J Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 569 -4878
C - D 475 -4268
D - E 501 -4212
E - F 405 -2288
Chords Tens. Comp.
F - G 368 -1607
G - H 418 -2015
H - I 384 -2190
I - J 374 -2752
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - P 4107 -415
P - O 4148 -421
O - N 3606 -227
N - M 1893 -19
Chords Tens. Comp.
M - L 1791 -94
L - K 2166 -223
K - J 2168 -223
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
P - C 134 -54
C - O 179 -461
O - E 2588 -168
E - N 305 -2545
N - F 1488 -131
F - M 88 -634
Webs Tens. Comp.
M - G 852 -172
M - H 179 -247
L - H 85 -140
L - I 175 -588
I - K 232 0
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.40 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.355 O 999 240
VERT(CL): 0.532 O 760 180
HORZ(LL): 0.248 K - -
HORZ(TL): 0.372 K - -
Creep Factor: 2.0
Max TC CSI: 0.746
Max BC CSI: 0.849
Max Web CSI: 0.866
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G8
Ply: 1
Qty: 2
Wgt: 0.0 lbs
SEQN: 126509 / T34 / COMN
FROM: BF DRW:
... / ... 03/19/2020
T1
B1
W5
W6
W7
W8
W9
34'
5'8"5
5'8"5
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
27'6"9
6'0"9
34'
6'5"7
5"8
5"8
5'8"5
5'2"13
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
27'6"9
6'0"9
34'
6'5"71'4"
4"7
3'6
"
1
10
'
8
"
7
11
'
6
"
1
4
(a)
(a)
(a)
A
B
C D
E
F G
H
I
J
KL
M
N
O
P
8
12
4
12
4X8(F2T)
2X4
3X6
3X6
8X8
6X10
5X6
5X6
4X8
5X6
5X8
3X6
3X6
2X4
4X6(B1)
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1,W2,W3,W4,
W11 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Right end vertical not exposed to wind pressure.
Right cantilever is exposed to wind
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1610 /- /- /642 /100 /233
P 1511 /- /0 /527 /97 /0
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req = 1.6
P Brg Width = 5.5 Min Req = 1.6
Bearings B & P Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 537 -3887
C - D 447 -3188
D - E 473 -3131
Chords Tens. Comp.
E - F 330 -1576
F - G 283 -980
G - H 331 -1304
H - I 208 -1191
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - O 3257 -526
O - N 3287 -532
N - M 2667 -341
Chords Tens. Comp.
M - L 1268 -92
L - K 939 -103
K - J 4 -9
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
O - C 153 -19
C - N 175 -548
N - E 2021 -240
E - M 364 -2069
M - F 1203 -160
F - L 88 -765
Webs Tens. Comp.
L - G 515 -148
L - H 255 -65
K - H 168 -885
K - I 1012 -100
I - J 215 -1342
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.272 N 999 240
VERT(CL): 0.408 N 812 180
HORZ(LL): 0.185 J - -
HORZ(TL): 0.278 J - -
Creep Factor: 2.0
Max TC CSI: 0.806
Max BC CSI: 0.941
Max Web CSI: 0.676
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G9
Ply: 1
Qty: 3
Wgt: 0.0 lbs
SEQN: 126569 / T21 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W2
W3
W4
W11
28'2"15
5'8"5
5'8"5
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'2"15
6'8"15
5"8
5"8
5'8"5
5'2"13
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'2"15
6'8"151'4"
4"7
4'2
"
8
3'6
"
1
10
'
8
"
7
11
'
6
"
1
4
(a)
(a)
(a)
A
B
C D
E
F G
H
I
JK
L
M
N
O
P
8
12
4
12
4X6(F1T)
2X4
3X6
3X6
6X6
5X8
4X6
4X6
4X8
4X6
6X10
3X6
3X6(R)
3X6
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1,W2,W3,W4,
W11 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Right end vertical not exposed to wind pressure.
Right cantilever is exposed to wind
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1610 /- /- /642 /100 /233
P 1511 /- /0 /527 /97 /0
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req = 1.6
P Brg Width = 5.5 Min Req = 1.6
Bearings B & P Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 537 -3887
C - D 447 -3188
D - E 473 -3131
Chords Tens. Comp.
E - F 330 -1576
F - G 283 -980
G - H 331 -1304
H - I 208 -1191
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - O 3257 -526
O - N 3287 -532
N - M 2667 -341
Chords Tens. Comp.
M - L 1268 -92
L - K 939 -103
K - J 4 -9
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
O - C 153 -19
C - N 175 -548
N - E 2021 -240
E - M 364 -2069
M - F 1203 -160
F - L 88 -765
Webs Tens. Comp.
L - G 515 -148
L - H 255 -65
K - H 168 -885
K - I 1012 -100
I - J 215 -1342
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.272 N 999 240
VERT(CL): 0.408 N 812 180
HORZ(LL): 0.185 J - -
HORZ(TL): 0.278 J - -
Creep Factor: 2.0
Max TC CSI: 0.806
Max BC CSI: 0.941
Max Web CSI: 0.676
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G9
Ply: 1
Qty: 3
Wgt: 0.0 lbs
SEQN: 126569 / T21 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W2
W3
W4
W11
28'2"15
5'8"5
5'8"5
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'2"15
6'8"15
5"8
5"8
5'8"5
5'2"13
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'2"15
6'8"151'4"
4"7
4'2
"
8
3'6
"
1
10
'
8
"
7
11
'
6
"
1
4
(a)
(a)
(a)
A
B
C D
E
F G
H
I
JK
L
M
N
O
P
8
12
4
12
4X6(F1T)
2X4
3X6
3X6
6X6
5X8
4X6
4X6
4X8
4X6
6X10
3X6
3X6(R)
3X6
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1,W2,W3,W4,
W11 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Right end vertical not exposed to wind pressure.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1636 /- /- /651 /101 /233
J 1486 /- /- /515 /96 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req = 1.6
J Brg Width = - Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 548 -3966
C - D 458 -3274
D - E 485 -3217
Chords Tens. Comp.
E - F 338 -1634
F - G 289 -1026
G - H 339 -1358
H - I 222 -1296
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - O 3325 -535
O - N 3356 -542
N - M 2741 -351
Chords Tens. Comp.
M - L 1324 -100
L - K 1010 -113
K - J 20 -5
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
O - C 151 -22
C - N 174 -541
N - E 2064 -245
E - M 369 -2105
M - F 1243 -166
F - L 89 -772
Webs Tens. Comp.
L - G 543 -152
L - H 180 -87
K - H 151 -763
K - I 1085 -110
I - J 227 -1437
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.257 N 999 240
VERT(CL): 0.385 N 875 180
HORZ(LL): 0.190 J - -
HORZ(TL): 0.285 J - -
Creep Factor: 2.0
Max TC CSI: 0.824
Max BC CSI: 0.963
Max Web CSI: 0.691
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G10
Ply: 1
Qty: 2
Wgt: 0.0 lbs
SEQN: 126574 / T29 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W2
W3
W4
W11
28'3"
(J)Supporting Member: (2)
5'8"5
5'8"5
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'3"
6'9"
5"8
5"8
5'8"5
5'2"13
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'3"
6'9"1'4"
4"7
4'2
"
7
3'6
"
1
10
'
8
"
7
11
'
6
"
1
4
(a)
(a)
(a)
A
B
C
D
E
F G
H
I
JK
L
M
N
O
8
12
4
12
5X6(F1T)
2X4
3X6
3X6
6X6
5X8
4X6
4X6
4X8
4X6
4X8
3X6
3X6(R)
3X6
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1,W2,W3,W4,
W11 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Right end vertical not exposed to wind pressure.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1636 /- /- /651 /101 /233
J 1486 /- /- /515 /96 /-
Wind reactions based on MWFRS
B Brg Width = 5.5 Min Req = 1.6
J Brg Width = - Min Req = -
Bearing B Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 70 0
B - C 548 -3966
C - D 458 -3274
D - E 485 -3217
Chords Tens. Comp.
E - F 338 -1634
F - G 289 -1026
G - H 339 -1358
H - I 222 -1296
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - O 3325 -535
O - N 3356 -542
N - M 2741 -351
Chords Tens. Comp.
M - L 1324 -100
L - K 1010 -113
K - J 20 -5
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
O - C 151 -22
C - N 174 -541
N - E 2064 -245
E - M 369 -2105
M - F 1243 -166
F - L 89 -772
Webs Tens. Comp.
L - G 543 -152
L - H 180 -87
K - H 151 -763
K - I 1085 -110
I - J 227 -1437
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.257 N 999 240
VERT(CL): 0.385 N 875 180
HORZ(LL): 0.190 J - -
HORZ(TL): 0.285 J - -
Creep Factor: 2.0
Max TC CSI: 0.824
Max BC CSI: 0.963
Max Web CSI: 0.691
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G10
Ply: 1
Qty: 2
Wgt: 0.0 lbs
SEQN: 126574 / T29 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W2
W3
W4
W11
28'3"
(J)Supporting Member: (2)
5'8"5
5'8"5
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'3"
6'9"
5"8
5"8
5'8"5
5'2"13
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'3"
6'9"1'4"
4"7
4'2
"
7
3'6
"
1
10
'
8
"
7
11
'
6
"
1
4
(a)
(a)
(a)
A
B
C
D
E
F G
H
I
JK
L
M
N
O
8
12
4
12
5X6(F1T)
2X4
3X6
3X6
6X6
5X8
4X6
4X6
4X8
4X6
4X8
3X6
3X6(R)
3X6
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1,W2,W3,W4,
W11 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Right end vertical not exposed to wind pressure.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1506 /- /- /581 /83 /218
H 1486 /- /- /515 /97 /-
Wind reactions based on MWFRS
A Brg Width = 5.5 Min Req = 1.5
H Brg Width = - Min Req = -
Bearing A Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 570 -3965
B - C 493 -3274
C - D 340 -1634
Chords Tens. Comp.
D - E 291 -1026
E - F 340 -1358
F - G 223 -1296
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - M 3324 -558
M - L 3355 -563
L - K 2741 -357
Chords Tens. Comp.
K - J 1324 -102
J - I 1010 -114
I - H 20 -5
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
M - B 154 -9
B - L 189 -540
L - C 2064 -254
C - K 374 -2105
K - D 1243 -169
D - J 91 -772
Webs Tens. Comp.
J - E 543 -154
J - F 182 -87
I - F 152 -763
I - G 1085 -111
G - H 229 -1437
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.253 L 999 240
VERT(CL): 0.383 L 881 180
HORZ(LL): 0.187 H - -
HORZ(TL): 0.283 H - -
Creep Factor: 2.0
Max TC CSI: 0.761
Max BC CSI: 0.905
Max Web CSI: 0.690
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G11
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126576 / T33 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W2
W3
W4
W11
28'3"
(J)Supporting Member: (2)
5'8"5
5'8"5
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'3"
6'9"
5"8
5"8
5'8"5
5'2"13
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'3"
6'9"
4"7
4'2
"
7
3'6
"
1
10
'
8
"
7
(a)
(a)
(a)
A
B
C
D E
F
G
HI
J
K
L
M
8
12
4
12
4X6(F1)
2X4
3X6
6X6
5X8
4X6
4X6
4X8
4X6
4X8
3X6
3X6(R)
3X6
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L #1&Bet.; W1,W2,W3,W4,
W11 2x4 DF-L Stud;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Right end vertical not exposed to wind pressure.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1506 /- /- /581 /83 /218
H 1486 /- /- /515 /97 /-
Wind reactions based on MWFRS
A Brg Width = 5.5 Min Req = 1.5
H Brg Width = - Min Req = -
Bearing A Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 570 -3965
B - C 493 -3274
C - D 340 -1634
Chords Tens. Comp.
D - E 291 -1026
E - F 340 -1358
F - G 223 -1296
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - M 3324 -558
M - L 3355 -563
L - K 2741 -357
Chords Tens. Comp.
K - J 1324 -102
J - I 1010 -114
I - H 20 -5
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
M - B 154 -9
B - L 189 -540
L - C 2064 -254
C - K 374 -2105
K - D 1243 -169
D - J 91 -772
Webs Tens. Comp.
J - E 543 -154
J - F 182 -87
I - F 152 -763
I - G 1085 -111
G - H 229 -1437
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.253 L 999 240
VERT(CL): 0.383 L 881 180
HORZ(LL): 0.187 H - -
HORZ(TL): 0.283 H - -
Creep Factor: 2.0
Max TC CSI: 0.761
Max BC CSI: 0.905
Max Web CSI: 0.690
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G11
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126576 / T33 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W1
W2
W3
W4
W11
28'3"
(J)Supporting Member: (2)
5'8"5
5'8"5
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'3"
6'9"
5"8
5"8
5'8"5
5'2"13
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'3"
6'9"
4"7
4'2
"
7
3'6
"
1
10
'
8
"
7
(a)
(a)
(a)
A
B
C
D E
F
G
HI
J
K
L
M
8
12
4
12
4X6(F1)
2X4
3X6
6X6
5X8
4X6
4X6
4X8
4X6
4X8
3X6
3X6(R)
3X6
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; W5,W6,W7,W8,W9,
W10 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Right end vertical not exposed to wind pressure.
Additional Notes
Shim all supports to solid bearing.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1183 /- /- /437 /64 /218
I 1651 /- /- /739 /101 /-
H 293 /-117 /- /121 /101 /-
Wind reactions based on MWFRS
A Brg Width = - Min Req = -
I Brg Width = 5.5 Min Req = 1.5
H Brg Width = - Min Req = -
Bearing I Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 441 -2990
B - C 349 -2197
C - D 246 -924
Chords Tens. Comp.
D - E 207 -404
E - F 241 -621
F - G 107 -283
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - N 2491 -448
N - M 2509 -451
M - L 1803 -232
L - K 698 -20
Chords Tens. Comp.
K - J 138 -28
J - I 307 -1747
I - H 16 -5
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
N - B 177 0
B - M 203 -647
M - C 1500 -179
C - L 311 -1630
L - D 957 -134
D - K 110 -890
Webs Tens. Comp.
K - E 176 -99
K - F 830 -35
J - F 230 -1437
J - G 2150 -346
I - G 383 -2157
G - H 120 -270
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.181 M 999 240
VERT(CL): 0.264 M 999 180
HORZ(LL): 0.134 J - -
HORZ(TL): 0.202 J - -
Creep Factor: 2.0
Max TC CSI: 0.532
Max BC CSI: 0.614
Max Web CSI: 0.602
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G12
Ply: 1
Qty: 5
Wgt: 0.0 lbs
SEQN: 126578 / T35 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W5
W6
W7
W8
W9 W10
22'6"8 5'8"8
(J)Supporting Member: (2)(J)Supporting Member: (2)
5'8"5
5'8"5
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'3"
6'9"
5"8
5"8
5'8"5
5'2"13
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
22'9"4
1'3"4
28'3"
5'5"12
4"7
4'2
"
7
3'6
"
1
10
'
8
"
7
(a)
(a)
(a)
(a)
A
B
C
D E
F
G
HIJ
K
L
M
N
8
12
4
12
3X6(F2)
2X4
3X6
6X6
5X6
4X6
5X6
4X8
4X6
8X8
4X6
3X6
4X12(R)
2X4
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; W5,W6,W7,W8,W9,
W10 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Hangers / Ties
(J) Hanger Support Required, by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Right end vertical not exposed to wind pressure.
Additional Notes
Shim all supports to solid bearing.
Maximum Reactions (lbs)
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1183 /- /- /437 /64 /218
I 1651 /- /- /739 /101 /-
H 293 /-117 /- /121 /101 /-
Wind reactions based on MWFRS
A Brg Width = - Min Req = -
I Brg Width = 5.5 Min Req = 1.5
H Brg Width = - Min Req = -
Bearing I Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 441 -2990
B - C 349 -2197
C - D 246 -924
Chords Tens. Comp.
D - E 207 -404
E - F 241 -621
F - G 107 -283
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - N 2491 -448
N - M 2509 -451
M - L 1803 -232
L - K 698 -20
Chords Tens. Comp.
K - J 138 -28
J - I 307 -1747
I - H 16 -5
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
N - B 177 0
B - M 203 -647
M - C 1500 -179
C - L 311 -1630
L - D 957 -134
D - K 110 -890
Webs Tens. Comp.
K - E 176 -99
K - F 830 -35
J - F 230 -1437
J - G 2150 -346
I - G 383 -2157
G - H 120 -270
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.181 M 999 240
VERT(CL): 0.264 M 999 180
HORZ(LL): 0.134 J - -
HORZ(TL): 0.202 J - -
Creep Factor: 2.0
Max TC CSI: 0.532
Max BC CSI: 0.614
Max Web CSI: 0.602
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G12
Ply: 1
Qty: 5
Wgt: 0.0 lbs
SEQN: 126578 / T35 / COMN
FROM: BF DRW:
... / ... 03/19/2020
W5
W6
W7
W8
W9 W10
22'6"8 5'8"8
(J)Supporting Member: (2)(J)Supporting Member: (2)
5'8"5
5'8"5
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
28'3"
6'9"
5"8
5"8
5'8"5
5'2"13
10'11"12
5'3"7
15'6"
4'6"4
18'6"
3'
21'6"
3'
22'9"4
1'3"4
28'3"
5'5"12
4"7
4'2
"
7
3'6
"
1
10
'
8
"
7
(a)
(a)
(a)
(a)
A
B
C
D E
F
G
HIJ
K
L
M
N
8
12
4
12
3X6(F2)
2X4
3X6
6X6
5X6
4X6
5X6
4X8
4X6
8X8
4X6
3X6
4X12(R)
2X4
- F A L L C R E E K H O M E SM T T M P A N O G A S - F A L L C R E E K H O M E S
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; M6,M7,M8,M9,M10,
M11 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Right end vertical not exposed to wind pressure.
Right cantilever is exposed to wind
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A* 215 /- /- /73 /16 /21
AJ* 533 /- /- /253 /121 /-
Wind reactions based on MWFRS
A Brg Width = 249 Min Req = -
AJ Brg Width = 26.5 Min Req = -
Bearings A & AJ Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 449 -457
B - C 418 -364
C - D 385 -283
D - E 397 -220
E - F 406 -158
F - G 415 -127
G - H 425 -96
H - I 405 -65
Chords Tens. Comp.
I - J 352 -31
J - K 354 -31
K - L 365 -41
L - M 428 -14
M - N 435 0
N - O 460 -27
O - P 313 -64
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A -AE 394 -358
AE-AD 406 -369
AD-AC 411 -374
AC-AB 414 -377
AB-AA 416 -380
AA- Z 418 -382
Z - Y 420 -383
Y - X 421 -384
Chords Tens. Comp.
X - W 110 -260
W - V 109 -266
V - U 109 -266
U - T 109 -262
T - S 72 -36
S - R 27 -12
R - Q 6 -3
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
T -AG 175 -411
AF-AI 155 -370
Webs Tens. Comp.
AH- P 110 -269
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
B -AE 157 -327
C -AD 151 -372
D -AC 151 -375
E -AB 153 -387
F -AA 151 -392
G - Z 155 -398
Gables Tens. Comp.
J - V 23 -631
U - L 51 -473
M - T 189 -421
AF- N 175 -464
AG- S 156 -424
AH- O 92 -190
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.038 O 846 240
VERT(CL): 0.057 O 572 180
HORZ(LL): 0.021 M - -
HORZ(TL): 0.031 M - -
Creep Factor: 2.0
Max TC CSI: 0.292
Max BC CSI: 0.436
Max Web CSI: 0.302
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G13
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126522 / T20 / GABL
FROM: BF
Page 1 of 2
DRW:
... / ... 03/19/2020
M6
M7
M8
M9
M10
M11
23'4'3"
1'7"8
2'(TYP)
1'5"12
15'6"
15'6"
18'6"
3'
27'3"
8'9"
27'3"
27'3"
4"7
4'1
0
"
7
10
'
8
"
7
(a)(a)(a)(a)
(a)
A
B
C
D
E
F
G
H
I J K
L
M
N
O
P
QRSTUVWXYZAAABACADAE
AF AG
AH AI
AJ
8
12
2X4(A1)
3X6
4X6
3X6
3X6
3X6
3X6
3X6
3X6
3X6
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Webs: 2x4 DF-L Stud; M6,M7,M8,M9,M10,
M11 2x4 DF-L #1&Bet.;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Plating Notes
All plates are 2X4 except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Right end vertical not exposed to wind pressure.
Right cantilever is exposed to wind
Additional Notes
See DWGS A11515ENC101014, GBLLETIN0118, &
GABRST101014 for gable wind bracing and other
requirements.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A* 215 /- /- /73 /16 /21
AJ* 533 /- /- /253 /121 /-
Wind reactions based on MWFRS
A Brg Width = 249 Min Req = -
AJ Brg Width = 26.5 Min Req = -
Bearings A & AJ Fcperp = 625psi.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 449 -457
B - C 418 -364
C - D 385 -283
D - E 397 -220
E - F 406 -158
F - G 415 -127
G - H 425 -96
H - I 405 -65
Chords Tens. Comp.
I - J 352 -31
J - K 354 -31
K - L 365 -41
L - M 428 -14
M - N 435 0
N - O 460 -27
O - P 313 -64
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A -AE 394 -358
AE-AD 406 -369
AD-AC 411 -374
AC-AB 414 -377
AB-AA 416 -380
AA- Z 418 -382
Z - Y 420 -383
Y - X 421 -384
Chords Tens. Comp.
X - W 110 -260
W - V 109 -266
V - U 109 -266
U - T 109 -262
T - S 72 -36
S - R 27 -12
R - Q 6 -3
Maximum Web Forces Per Ply (lbs)
Webs Tens.Comp.
T -AG 175 -411
AF-AI 155 -370
Webs Tens. Comp.
AH- P 110 -269
Maximum Gable Forces Per Ply (lbs)
Gables Tens.Comp.
B -AE 157 -327
C -AD 151 -372
D -AC 151 -375
E -AB 153 -387
F -AA 151 -392
G - Z 155 -398
Gables Tens. Comp.
J - V 23 -631
U - L 51 -473
M - T 189 -421
AF- N 175 -464
AG- S 156 -424
AH- O 92 -190
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.038 O 846 240
VERT(CL): 0.057 O 572 180
HORZ(LL): 0.021 M - -
HORZ(TL): 0.031 M - -
Creep Factor: 2.0
Max TC CSI: 0.292
Max BC CSI: 0.436
Max Web CSI: 0.302
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G13
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126522 / T20 / GABL
FROM: BF
Page 1 of 2
DRW:
... / ... 03/19/2020
M6
M7
M8
M9
M10
M11
23'4'3"
1'7"8
2'(TYP)
1'5"12
15'6"
15'6"
18'6"
3'
27'3"
8'9"
27'3"
27'3"
4"7
4'1
0
"
7
10
'
8
"
7
(a)(a)(a)(a)
(a)
A
B
C
D
E
F
G
H
I J K
L
M
N
O
P
QRSTUVWXYZAAABACADAE
AF AG
AH AI
AJ
8
12
2X4(A1)
3X6
4X6
3X6
3X6
3X6
3X6
3X6
3X6
3X6
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
H - Y 164 -451
I - W 14 -497
AI- R 64 -101
P - Q 91 -44
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G13
Ply: 1
Qty: 1
Wgt: 0.0 lbs
SEQN: 126522 / T20 / GABL
FROM: BF
Page 2 of 2
DRW:
... / ... 03/19/2020
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Plating Notes
All plates are 2X4(A1T) except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 59 /- /- /30 /13 /37
B* 268 /- /- /87 /29 /-
E 59 /- /- /26 /13 /-
Wind reactions based on MWFRS
A Brg Width = 6.3 Min Req = 1.5
B Brg Width = 17.8 Min Req = -
E Brg Width = 6.3 Min Req = 1.5
Bearings A, B, & E are a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 48 -47
B - C 28 -99
Chords Tens. Comp.
C - D 28 -99
D - E 22 -33
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 61 -9
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.000 999 240
VERT(CL): 0.000 999 180
HORZ(LL): 0.000 - -
HORZ(TL): 0.000 - -
Creep Factor: 2.0
Max TC CSI: 0.013
Max BC CSI: 0.012
Max Web CSI: 0.000
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G-CAP1
Ply: 1
Qty: 2
Wgt: 0.0 lbs
SEQN: 126484 / T19 / GABL
FROM: BF DRW:
... / ... 03/19/2020
9"2 1'5"12 9"2
9"2
9"2
1'6"
8"14
2'2"14
8"14
3'
9"2
9"2
9"2
2'2"14
1'5"12
3'
9"26"5
6"5
10
"
6
1"10
1'
A
B
C
D
E
8
12
3X6
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Plating Notes
All plates are 2X4(A1T) except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 59 /- /- /30 /13 /37
B* 268 /- /- /87 /29 /-
E 59 /- /- /26 /13 /-
Wind reactions based on MWFRS
A Brg Width = 6.3 Min Req = 1.5
B Brg Width = 17.8 Min Req = -
E Brg Width = 6.3 Min Req = 1.5
Bearings A, B, & E are a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 48 -47
B - C 28 -99
Chords Tens. Comp.
C - D 28 -99
D - E 22 -33
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 61 -9
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.000 999 240
VERT(CL): 0.000 999 180
HORZ(LL): 0.000 - -
HORZ(TL): 0.000 - -
Creep Factor: 2.0
Max TC CSI: 0.013
Max BC CSI: 0.012
Max Web CSI: 0.000
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G-CAP1
Ply: 1
Qty: 2
Wgt: 0.0 lbs
SEQN: 126484 / T19 / GABL
FROM: BF DRW:
... / ... 03/19/2020
9"2 1'5"12 9"2
9"2
9"2
1'6"
8"14
2'2"14
8"14
3'
9"2
9"2
9"2
2'2"14
1'5"12
3'
9"26"5
6"5
10
"
6
1"10
1'
A
B
C
D
E
8
12
3X6
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Plating Notes
All plates are 2X4(A1T) except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 59 /- /- /30 /13 /37
B* 268 /- /- /87 /29 /-
E 59 /- /- /26 /13 /-
Wind reactions based on MWFRS
A Brg Width = 6.3 Min Req = 1.5
B Brg Width = 17.8 Min Req = -
E Brg Width = 6.3 Min Req = 1.5
Bearings A, B, & E are a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 48 -47
B - C 28 -99
Chords Tens. Comp.
C - D 28 -99
D - E 22 -33
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 61 -9
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.000 999 240
VERT(CL): 0.000 999 180
HORZ(LL): 0.000 - -
HORZ(TL): 0.000 - -
Creep Factor: 2.0
Max TC CSI: 0.013
Max BC CSI: 0.012
Max Web CSI: 0.000
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G-CAP2
Ply: 1
Qty: 24
Wgt: 0.0 lbs
SEQN: 126486 / T30 / GABL
FROM: BF DRW:
... / ... 03/19/2020
9"2 1'5"12 9"2
9"2
9"2
1'6"
8"14
2'2"14
8"14
3'
9"2
9"2
9"2
2'2"14
1'5"12
3'
9"26"5
6"5
10
"
6
1"10
1'
A
B
C
D
E
8
12
3X6
**WARNING**READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT**FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build thetruss in conformance with ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover pagelisting this drawing, indicates acceptance of professional engineering responsibility solely for the design shown. The suitabilityand use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see this job's general notes page and these web sites: ALPINE: www.alpineitw.com; TPI: www.tpinst.org; SBCA: www.sbcindustry.com; ICC: www.iccsafe.org
Lumber
Top chord: 2x4 DF-L #1&Bet.;
Bot chord: 2x4 DF-L #1&Bet.;
Plating Notes
All plates are 2X4(A1T) except as noted.
Loading
Truss designed to support 2-0-0 top chord outlookers
and cladding load not to exceed 3.00 PSF one face
and 24.0" span opposite face. Top chord must not be
cut or notched, unless specified otherwise.
Bottom chord checked for 10.00 psf non-concurrent
bottom chord live load applied per IRC-15 section
301.5.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to brace TC @ 24" oc, BC @ 24" oc.
Wind
Member design based on both MWFRS and C&C.
Additional Notes
Top Chord overhang(s) may be field trimmed.
Maximum Reactions (lbs), or *=PLF
Gravity Non-Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 59 /- /- /30 /13 /37
B* 268 /- /- /87 /29 /-
E 59 /- /- /26 /13 /-
Wind reactions based on MWFRS
A Brg Width = 6.3 Min Req = 1.5
B Brg Width = 17.8 Min Req = -
E Brg Width = 6.3 Min Req = 1.5
Bearings A, B, & E are a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)
Chords Tens.Comp.
A - B 48 -47
B - C 28 -99
Chords Tens. Comp.
C - D 28 -99
D - E 22 -33
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp.
B - D 61 -9
Loading Criteria (psf)
TCLL: 35.00
TCDL: 8.00
BCLL: 0.00
BCDL: 8.00
Des Ld: 51.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.15
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-10
Speed: 115 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.8 psf
BCDL: 4.8 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Snow Criteria (Pg,Pf in PSF)
Pg: 35.0 Ct: - CAT: -
Pf: 35.0 Ce: -
Lu: - Cs: -
Snow Duration: -
Code / Misc Criteria
Bldg Code: IRC 2015
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.000 999 240
VERT(CL): 0.000 999 180
HORZ(LL): 0.000 - -
HORZ(TL): 0.000 - -
Creep Factor: 2.0
Max TC CSI: 0.013
Max BC CSI: 0.012
Max Web CSI: 0.000
Mfg Specified Camber:
VIEW Ver: 19.02.02B.0122.16
Job Number:J209456
-FALL CREEK HOMES
Truss Label:G-CAP2
Ply: 1
Qty: 24
Wgt: 0.0 lbs
SEQN: 126486 / T30 / GABL
FROM: BF DRW:
... / ... 03/19/2020
9"2 1'5"12 9"2
9"2
9"2
1'6"
8"14
2'2"14
8"14
3'
9"2
9"2
9"2
2'2"14
1'5"12
3'
9"26"5
6"5
10
"
6
1"10
1'
A
B
C
D
E
8
12
3X6