Loading...
HomeMy WebLinkAboutRESCHECK - 20-00196 - 697 Tanglewood Dr - New SFRREScheck Software Version 4.6.5 Compliance Certificate Project Alpine heating and Air Energy Code:2015 IECC Location:Idaho Falls, Idaho Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:3,259 ft2 Glazing Area 16% Climate Zone:6 (7918 HDD) Permit Date: Construction Site:Owner/Agent: Alpine Heating And Air 208-523-5542 derik@alpineheatingair.com Designer/Contractor: Mechanical Compliance Solutions Mechanical Compliance Solutions 4181 Aschli lane Idaho Falls, ID 83406 208-881-3243 gene.mechcompliancesolutions@g mail.com Permit Number: Compliance: Passes using UA trade-off 1.4% Better Than Code Maximum UA:291 Your UA:287 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Wall 1: Wood Frame, 16" o.c.374 21.0 0.0 0.057 18 Door 1: Solid 23 0.140 3 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 29 0.320 9 Wall 2: Wood Frame, 16" o.c.450 21.0 0.0 0.057 22 Door 1: Solid 21 0.140 3 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 40 0.320 13 Wall 3: Wood Frame, 16" o.c.374 21.0 0.0 0.057 20 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 30 0.320 10 Wall 4: Wood Frame, 16" o.c.450 21.0 0.0 0.057 18 Door 1: Solid 21 0.140 3 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 118 0.320 38 Basement Wall 1: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' 351 19.0 0.0 0.045 15 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.320 5 Project Title: Alpine heating and Air Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\4-2-51 Stonebridge.rck Page 1 of 2 03/27/20Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Basement Wall 2: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' 450 19.0 0.0 0.045 20 Basement Wall 3: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' 351 19.0 0.0 0.045 15 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.320 5 Basement Wall 4: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 7.5' Insulation depth: 9.0' 450 19.0 0.0 0.045 20 Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.320 5 Ceiling 1: Flat Ceiling or Scissor Truss 1,714 50.0 0.0 0.026 45 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Notes: Job Number: 4-2-51 Stonebridge INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Project Title: Alpine heating and Air Data filename: C:\Users\1sgmi\AppData\Local\Check\REScheck\4-2-51 Stonebridge.rck Page 2 of 2 03/27/20Report date: